IDEXX is an ISO certified facility. Gil Dichter World Wide Technical Support Manager

Similar documents
IDEXX Summary 15B Topic

Blue Flag Beaches and Recreational Water Testing for and Enterococci E.coli using Enterolert & E. coli

Lab Exercise: Examining Water Quality: Most Probable Number & Colilert Test Kit Lab

Sample for Use as a Guide Revised IDEXX ENTEROLERT TEST METHOD FOR THE DETECTION OF ENTEROCOCCI IN WATER

Sample for use a Guide Revised IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E.

Microbiology Methods for Drinking Water Laboratories. Erica Fox

ENV H 433 LABORATORY EXERCISE 1

SOP-C-124 Determination of Total Coliform, Escherichia coli, and Enterococci by IDEXX Colilert and Enterolert

INTRODUCTION water-soluble Figure 1.

Microbiology Method Variability and Sensitivity in the Detection of Total

Discussion Items. Microbial Indicators of Water Quality

Modified Colitag Test Method for the Simultaneous Detection of E. coli and other Total Coliforms in Water (ATP D ) August 28, 2009

Keys to Improved PT results on Waste Water Microbiology Samples Waters Corporation 1

3 8 COLIFORM BACTERIA AS INDICATOR ORGANISMS Laboratory tests for disease-producing bacteria, viruses, and protozoa are difficult to perform

Lab Activity #14 - Bacteriological Examination Of Water and Milk (Adapted from Lab manual by Dr. Diehl)

A Comparison of the Bacteriological Quality of Drinking Water for the City of Johannesburg in the Wet and Dry Season

Aquagenx Compartment Bag Test (CBT) Performance Evaluation Data

KARL F. ECKNER* KM Lab AB, Helsingborg, Sweden. Received 6 January 1998/Accepted 7 May 1998

Adapted from Biology 15 Laboratory Manual Supplement: Wrightsman, Ininns and Cannon-Moloznic, Saddleback College, CA 92692

Microbiological Standards for Reusable Plastic Containers within Produce Grower Facilities

ENUMERATION OF COLIFORMS AND ESCHERICHIA COLI BY IDEXX (COLILERT 18) QUANTI-TRAY TM

Result:COMPLETE Report Date: December 28 th, 2015

DAIRY WATERS. (Coliform Group and Escherichia coli) [E. coli verification required only on source water] IMS #24

Modified mtec Agar, Colilert, and M-FC Agar - Field Trial Comparison of Bacteria Enumeration Methods in Surface Waters of Eastern Wyoming

IDEXX Summary. IDEXX Laboratories. Date: April Report Highlights:

MICROBIOLOGICAL DETECTION OF E. COLI WITH UNPARALLELED SENSITIVITY. RUG A novel beta-glucuronidase substrate

Tips to Support Microbiological Proficiency Testing Waters Corporation 1

Most Probable Number (MPN) & Biological Oxygen Demand (BOD)

Lab Exercise 13: Growth Curve

QUANTIDISC AND YEA METHOD COMPARISON

IDEXX Summary. IDEXX Laboratories. Date: February Report Highlights:

Laboratory Procedure October 1999 HEALTH PROTECTION BRANCH OTTAWA ANALYSIS OF SPROUTS FOR COLIFORMS, ESCHERICHIA COLI, AND KLEBSIELLA PNEUMONIAE..

Microbiological Standards for Reusable Plastic Containers within Produce Grower Facilities within Ontario and Quebec

Proficiency Testing. Drinking Water Microbiology. September Tommy Šlapokas NFA PT

Microbiological Standards for Reusable Plastic Containers within Produce Grower Facilities within Ontario and Quebec

2009 Summary Report for Municipalities

Environmental Biotechnology. CE421/521 Tim Ellis October 25, 2007

Introduction to Bacteria Monitoring of Surface water for Volunteers. Is the water safe?

COMPASS Ecc Agar. Microorganisms Typical phenotype Colony color. GUD + / -gal + GUD - / -gal + GUD - / -gal - 1/5

Lecture 7 Water Quality Monitoring: Estimation of fecal indicator bacteria

THE COLISCAN MEMBRANE FILTER METHOD of Micrology Laboratories LLC for ESCHERICHIA COLI AND TOTAL COLIFORMS

Water Quality Program Plan

Safe Drinking Water: Public Health Laboratory Surveillance

PROJECT TITLE (DNR PROJECT #226): Evaluation of Quantitative Real-Time PCR (qpcr) for the Measurement of E.coli in Well Water Samples

Escherichia coli and. Equivalence of the Colilert -18/Quanti-Tray water potability test for the detection and enumeration of

The Most Probable Number Method and Its Use in QC Microbiology

ANALYTICAL PROCEDURE. Bacteria: Hydrogen Sulfide Producing

ISO/FDIS INTERNATIONAL STANDARD FINAL DRAFT

NLA Conference 2009: Ingrid Flemming IFM Quality Services Pty Ltd, Australia

Aseptic Techniques. A. Objectives. B. Before coming to lab

Applied Environmental Microbiology. Copyright McGraw-Hill Global Education Holdings, LLC. Permission required for reproduction or display.

Northern Michigan Operators Spring Seminar. Lab Issues

M. Dalbey/Bio 105M Isolation of E. coli - Isolation of E. coli from an Environmental Sample

MICROPLATE MUG/EC 1/6

Validation of Hot Water and Lactic Acid Sprays for the Reduction of Enteric Pathogens on the Surface of Beef Carcasses

Analysis of Bottled Waters from the Water Refilling Stations in Ozamiz City. Wiliva Andoy Maritess Tapitan School of Hospitality Management.

Exercise 13 DETERMINATION OF MICROBIAL NUMBERS

RAPID Salmonella/Agar

Figure 1. Map of cloning vector pgem T-Easy (bacterial plasmid DNA)

Project to Address Water Quality Assessment Of Owl Creek Hot Springs County, Wyoming 2005

INTRODUCTION Contaminated serial dilution countable plates

Authors R. E. Danielson 1, J.R. Truscott BioVir Laboratories, Inc.; Benicia CA 2. Wastewater Management Div., City of Fresno, CA

Introduction. Michael J. Miller, Ph.D. RMM»

Dardenne Creek St. Charles County. May 2017 September Prepared for:

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018

Abalone Coast Analytical Laboratory Quality Assurance Manual

Bacterial inactivation claims in the context of sterility. Adonis Stassinopoulos, Ph.D V.P. Global Scientific Affairs and Research Cerus Corporation

Shehab. Yousef... Omar. Yousef Omar. Anas

Bacterial Abundance. Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here.

FILTRATION OF BACTERIAL COLIFORMS INCLUDING Escherichia coli IN WATER TREATED BY SLOW SAND FILTRATION. Anthony Chapetta

COUNT METHOD 5.0 OBJECTIVES 5.1 INTRODUCTION 5.2 PRINCIPLE. Structure

COMPARITIVE STUDY OF THE EFFECT OF SINGLE WALLED CARBON NANOTUBES ON Escherichia coli IN CULTURES AND BIOFILMS. A write-up on the proposed Study

Understanding and Teaching the Most Probable Number Technique 1

SAMPLING AND ANALYSIS PLAN. Crow Creek in Cheyenne

Some Industrially Important Microbes and Their Products

COMPARATIVE STUDY ON THE MICROBIOLOGICAL QUALITY OF WATER COOLER DISPENSERS AND TAP WATER

RAPID Salmonella. RAPID Salmonella. Ref# Description Pre-poured mm x 20 dishes mm x 120 dishes

01/08/2018. Counting Microorganisms. Counting microorganisms. Turbidity Measurements. Relative abundance. Direct counts.

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Salmonella Antigen Detection (In Food)

Standing Committee of Analysts

MICROBIAL PLATE COUNT USING IMAGE PROCESSING

Bacterial Abundance. Objective Measure bacterial numbers and mass per unit volume. Note, we are not concerned with identification here.

Bacteria Monitoring in Surface Waters - Methods

GROWTH AND SURVIVAL OF PATHOGENIC E. COLI DURING CURDLING OF MILK

The Biotechnology Education Company. Water Quality Testing I: Chromogenic Analysis of Water Contaminants. See Page 3 for storage instructions.

Public Health England (PHE) Certified Reference Materials for Microbiology. Certificate of Analysis Clostridium perfringens CRM13170L

Method 1680: Fecal Coliforms in Biosolids by Multiple-Tube Fermentation Procedures. October 2002 Draft

GeNei TM Transformation Teaching Kit Manual

Detection of Escherichia coli in Drinking Water Sources of Filter Units and Supply Water

TESTING SERVICES by Analyte

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

Rapid Microbiological Methods: Why and what!

Validation of Alternative Methods for the Analysis of Drinking Water and Their Application to Escherichia coli

TRADE-OFFS AND CHALLENGES FOR PRODUCT DEVELOPMENT

Transformation: Theory. Day 2: Transformation Relevant Book Sections

UBC Social Ecological Economic Development Studies (SEEDS) Student Report

LAB 1: Eau that smell

Technique for Testing Drinking Water

z.' lnitials: t"'tt14 s /r lrt sop-c-1 14 Determination of Fecal Coliform and Escherichia coli Revision 10 Approval: Effective date:

Transcription:

USEPA ATP Process for Approval of Colilert-18 and Quanti-Tray for the Detection of Fecal Coliforms in Waste Water; What is a Number: Comparison of MPN and CFU Gil Dichter World Wide Technical Support Manager gil-dichter@idexx.com IDEXX is an ISO 9001-2009 certified facility 1 2009 IDEXX Laboratories, Inc. All rights reserved. 1

Objectives Review of Water Microbiology DST Technology fecal coliforms Theory behind the method Procedure for testing Review of fecal coliform ATP for Colilert-18 Requirements to use this method for fecal coliforms QA/QC What is a Number- MPN vs. CFU 2 2009 IDEXX Laboratories, Inc. All rights reserved. 2

Bacteria Hierarchy Family Genus (type of bacteria) Species Enterobacteriaceae Escherichia, Klebsiella, Citrobacter E.coli, E. hermanii, K. pneumoniae, C. freundii 3 2009 IDEXX Laboratories, Inc. All rights reserved. 3

Coliform Genera Escherichia- human and animal feces Enterobacter- environment, feces Klebsiella- environment, feces Citrobacter- environment Serratia- environment 4 2009 IDEXX Laboratories, Inc. All rights reserved. 4

Thermotolerant Coliforms [aka Fecal Coliforms] It is a subset of total coliforms Defined as coliform bacteria that can grow at 44.5 C Consists of the following coliforms: E. coli K. pnuemoniae Enterobacter spp. possessing the enzyme β-d galactosidase cleaving the chromogenic substrate resulting in the release of the chromogen at 44.5ºC 5 2009 IDEXX Laboratories, Inc. All rights reserved. 5

Coliform Bacteria Group Total Coliforms (35 C) Klebsiella Fecal Coliforms / thermotolerant (44.5 C) Total coliforms (35 E.coli Citrobacter Enterobacter 6 2009 IDEXX Laboratories, Inc. All rights reserved. 6

Standard Bacterial Growth Curve Stationary Phase Death Phase Lag phase 7 2009 IDEXX Laboratories, Inc. All rights reserved. 7

Requirements for an Indicator Organism Present when pathogens are present Absent in uncontaminated waters Present in higher numbers than pathogens in contaminated water Better survival in water than pathogens Easy and Safe to analyze Rapid results Inexpensive Accurate 8 2009 IDEXX Laboratories, Inc. All rights reserved. 8

Defined Substrate Technology- Colilert-18 for Fecal Coliforms (Thermotolerant) 9 2009 IDEXX Laboratories, Inc. All rights reserved. 9

ONPG Positive Reaction Colilert-18 10 2009 IDEXX Laboratories, Inc. All rights reserved. 10

Separation of Snap Packs 11 2009 IDEXX Laboratories, Inc. All rights reserved. 11

Quanti-Tray Demonstration Add Colilert-18 to sample and shake to dissolve Pour mixture into a Quanti-Tray 12 2009 IDEXX Laboratories, Inc. All rights reserved. 12

Quanti-Tray Demonstration cont. Seal tray with the Sealer 13 2009 IDEXX Laboratories, Inc. All rights reserved. 13

Incubate Samples for 18-22 hours at 44.5 ºC± 0.2ºC for Colilert-18 (FC) 14 2009 IDEXX Laboratories, Inc. All rights reserved. 14

Or A Water Bath at 44.5±0.2ºC 15 2009 IDEXX Laboratories, Inc. All rights reserved. 15

Quanti-Tray Demonstration cont. Count positive wells and refer to MPN table 16 2009 IDEXX Laboratories, Inc. All rights reserved. 16

17 2009 IDEXX Laboratories, Inc. All rights reserved. 17

51-Well Quanti-Tray MPN Table No of Wells MPN per 95% Lower 95% Upper giving 100 ml Confidence Confidence positive Limits Limits reaction 0 <1 0 3.7 5 5.3 2.3 12.3 15 17.8 10.8 29.4 25 34.4 23.3 51.2 45 109.1 78.6 158.7 18 2009 IDEXX Laboratories, Inc. All rights reserved. 18

19 2009 IDEXX Laboratories, Inc. All rights reserved. 19

Quanti-Tray 2000 MPN Table No of large No of small MPN per 95% Lower 95% Upper wells giving wells giving 100ml Confidence Confidence positive positive sample Limit Limit reaction reaction 10 2 13.2 7.1 22.0 30 12 64 46.8 85.1 47 40 509.9 393.4 652.5 20 2009 IDEXX Laboratories, Inc. All rights reserved. 20

QA/QC Read results at18 hours and up to 22 hours Be consistent with time to read results Use Comparator as indicated in the package insert for Colilert-18 Proficiency Testing 21 2009 IDEXX Laboratories, Inc. All rights reserved. 21

Colilert-18 Fecal Coliform ATP Study The study was based on USEPA ATP protocol (40CFR136) Colilert-18/Quanti-Tray compared against m-fc (SM 9222D) to determine fecals in waste water Based on the ATP Study, the EPA determined that Colilert- 18 is a suitable method for the detection of fecal coliforms in wastewater. Protocol Summary Primary wastewater effluent samples from 10 different locations within the New England area were approved for use as sources of fecal coliform bacteria for this study. Effluent samples were collected, processed and tested at a certified laboratory within six hours. 22 2009 IDEXX Laboratories, Inc. All rights reserved. 22

Colilert-18 -Fecal Coliform ATP Study If necessary, effluent samples were diluted to approximately 20-50 organisms per 100 ml of sample. Each sample was analyzed by Colilert-18 and SM9222D in replicates of 20 after incubation at 44.5 ±0.2 C. Sensitivity of fecal coliform detection was determined by comparing the number of presumptive positive responses for the Colilert-18 against the number of presumptive positive responses from m-fc Specificity was determined by confirming the identity of at least 200 presumptive positive and 200 presumptive negative determinations from each test method. 23 2009 IDEXX Laboratories, Inc. All rights reserved. 23

Colilert-18 Fecal Coliform ATP Study Mean values for the 10 sites Colilert-18 51.4/100mL 37.8/100mL Test of variance equality for each method across the 10 sites based on Bartlett's test & Levene's test p-values Method M-FC p-value (Bartletts's Test) p > 0.05 False Positive and False Negative Rates p-value (Leven's test) p > 0.05 Colilert-18 0.308 0.619 SM9222D 0.006 0.042 Method Colilert-18 SM9222D False Positive Rate False Negative Rate 0% 0.5% 7.0% 21.5% 24 2009 IDEXX Laboratories, Inc. All rights reserved. 24

Colilert-18 Fecal Coliform ATP Study Comments on study findings: The EPA determined that Colilert-18 is a suitable method for the detection of fecal coliforms in wastewater when incubated at 44.5 C. The high false negative rate for SM9222D is hypothesized to be a result from SM9222D detecting fecal coliform bacteria via active lactose fermentation, which was found to be absent in 16.5% of the strains encountered in this study. These strains of anaerogenic fecal coliforms primarily belonged to the Escherichia and Klebsiella genus, and represent true fecal coliform bacterial and should have been detected. Read subjectivity: Analysts performing the study noted that m-fc can be highly subjective due to the varying morphological characteristics of the colonies. Other fecal coliform colonies on m-fc plates may lack the blue color, due to non-target organisms competing for nutrients and interfere with the growth of fecal coliforms. 25 2009 IDEXX Laboratories, Inc. All rights reserved. 25

Requirements to use Colilert-18 & Quanti-Tray from USEPA region 5. Lab contact Ken Gunther at 312-353-9076 or email gunther.kenneth@epamail.epa.gov and request to use Colilert-18 under current NPDES permit Ken will let state know it is okay with Region 5 to use Colilert-18 for fecals Will require parallel testing running 7-20 samples Lab should have new package insert for method 26 2009 IDEXX Laboratories, Inc. All rights reserved. 26

Certificates of Quality Obtain a C of Q for all our products from our website http://www.idexx.com/water/certificates/ Indicates all the testing performed for the specific product and lot Signed by QC for completion date of testing along with QA approval > All products are under quarantined until the batch records are reviewed and approved by QA > Once approved by QA, the specific product and lot is released for distribution 27 2009 IDEXX Laboratories, Inc. All rights reserved. 27

28 2009 IDEXX Laboratories, Inc. All rights reserved. 28

29 2009 IDEXX Laboratories, Inc. All rights reserved. 29

30 2009 IDEXX Laboratories, Inc. All rights reserved. 30

Estimation of Bacterial Densities by MPN Dates back to 1915 when the concept was introduced by M.H. McCrady (J of Infectious Disease Vol 17, 1915*) Prior to this novel concept; no means of direct counting Only had presence-absence of fermentation tubes The method is a means for estimating without any direct count, the density of organisms in a liquid. Multiple samples of the liquid are taken and incubated in suitable media Record presence or absence of growth in each sample tube Ingenious application of probability theory Estimate the number of organisms from the number of negative tubes *The Numerical Interpretation of Fermentation Tube Results 31 2009 IDEXX Laboratories, Inc. All rights reserved. 31

MPN Theory a short math lesson Basic assumptions: The organisms are distributed randomly throughout the liquid > Sample is well shaken (important and often neglected) A sample will exhibit growth (in the culture media) whenever one or more of the target organisms is present > Media should be selective and sensitive Requires that at least 1 tube shows no growth (sterile) If n samples, each of volume v ml are taken from a liquid, and s of these are sterile, then an estimate of the organism density d per ml in the original sample is: d = -2.303/v log(s/n) [Poisson distribution] d can be shown statistically to have the highest probability of estimating the actual organism density the Most Probable Number - MPN 32 2009 IDEXX Laboratories, Inc. All rights reserved. 32

Single dilution Maximum counting range Number of Tubes Maximum MPN/100mL Number of Tubes Maximum MPN/100mL 5 8 35 125 10 23 40 148 15 40 45 171 20 60 50 196 25 80 75 324 30 102 100 461 n = 50, v = 2 ml, s = 1 d = -2.303/v log(s/n) d = -2.303/2 log (1/50) = 1.956 MPN/mL = 195.6 MPN/100 ml 33 2009 IDEXX Laboratories, Inc. All rights reserved. 33

Uncertainty of MPN Skewed distribution & Uncertainty of Results For microbiological tests, because of the complications of the skewed distribution, the estimate of uncertainty from a welldesigned precision experiment will be regarded as a reasonable estimate of the uncertainty of results When MPN tables are used to obtain results, the 95% CL in the table will be regarded as a reasonable estimate of the uncertainty of the results Labs are encourage to identify and question unusual combinations of positive tubes in the tables. 15 tube MPN combination of + tubes»1-2-3»3-5-4 34 2009 IDEXX Laboratories, Inc. All rights reserved. 34

Standard Methods MPN Table 15 Tube 35 2009 IDEXX Laboratories, Inc. All rights reserved. 35

Overcoming the tube numbers problem To increase counting range need more tubes For 100mL sample could use 50 tubes x 2mL Would give counting range of ~200MPN/100mL Big headache for lab lots of tubes lots of pipettes -lots of washing! Not really practical. Microtitre plate (96 wells) MPN range 438/100mL 36 2009 IDEXX Laboratories, Inc. All rights reserved. 36

Quanti-Tray Use multiple well concept but automate the sealing 51 well Quanti-Tray Total sample volume 100mL d = -2.303/v log(s/n) n = 51, v = 1.96 ml, s = 1 d = -2.303/1.96 log (1/51) = 2.006 MPN/mL = 200.6 MPN/100 ml 37 2009 IDEXX Laboratories, Inc. All rights reserved. 37

Multiple Dilutions Not practical to extend the counting range by increasing the number of wells beyond a certain point. Sample serially diluted and each dilution is inoculated into a similar number of tubes. Commonly used configurations: 3 tubes x 3 decimal dilutions food industry 5 tubes x 3 decimal dilutions food, water wastewater (Max MPN = 1600/100mL) With multiple dilutions the statistical calculation of the MPN value becomes more complex. Thomas provided an approximation that could be used for any combination of tubes MPN/100mL = # of positive tubes x 100 (# of ml in negative tubes) x (# of ml in all tubes) 38 2009 IDEXX Laboratories, Inc. All rights reserved. 38

Quanti-Tray 2000 Innovative approach to provide a multiple dilution system without adding dilution water Small wells are 1/10 th the volume of the large wells Effectively a 49 x 48 tube serial dilution Using the Thomas formula: (MPN is an approximate, deviates from the MPN table and is not significant) Number of +ve tubes = 96 Volume of ve tubes = 0.186mL Volume in all tubes = 100mL MPN max = 96 x100 (0.186) x (100) = 2232/100mL vs 2419 39 2009 IDEXX Laboratories, Inc. All rights reserved. 39

Confidence Limits Distribution of MPN estimates is approximately log normal (distribution). Confidence limits can be calculated (95% limits = +/- 1.96s) Precision is low when the number of tubes is small. For 10 x 10mL tubes with 9 positive: MPN = 28/100mL the 95% confidence limits are: 11.5 68.1 MPN/100mL Confidence limits for 51 well Quanti-tray When increased to 51 x 1.96mL with 22 positive: MPN = 28.8/100mL The 95% confidence limits are: 19.0 44.3 MPN/100mL Interesting fact: If had 100 x 1mL with 25 positive: MPN = 29/100mL The 95% confidence limits are: 19.6 43.0 MPN/100mL Not much improvement 50 tubes is about optimum 40 2009 IDEXX Laboratories, Inc. All rights reserved. 40

41 2009 IDEXX Laboratories, Inc. All rights reserved. 41

95% Confidence Limit Comparison Quanti-Tray Quanti-Tray MTF MF MPN/100mL 2000 MPN/100mL CFU/100mL MPN/100mL Value CL Value CL Value CL Value CL 5.3 2.3-12.3 5.2 1.8-10.8 4.5 0.79-15 5 1.6-7.2 17.8 10.8-29.4 17.9 10.7-28.2 17 6.0-40 17 9.9-27.2 20.7 13-33.3 20.6 12.7-31.8 20 6.8-40 20 12.2-30.8 50.4 35.4-72.5 50.4 35.0-69.1 49 15-150 78.2 56.4-111.2 78.0 55.6-103.8 79 22-220 42 2009 IDEXX Laboratories, Inc. All rights reserved. 42