Low Temperature Testers

Similar documents
ADVANCED. Relaxation tests are becoming more and more popular for determination of rubber properties. From the beginning stress relaxation tests

Stress Relaxation and Creep System for testing of stress relaxation and creep

Low Temperature Check. Automatic instrument for the determination for both TR TEST and BRITTLENESS POINT

Automatic hardness testing devices

Stress Relaxation and Creep Systems

Rubber Low Temperature Brittleness Tester TRBT-A10

Ultra Low Temperature Freezer Chest -86 C, -60 C, -45 C

PRODUCT VT C LOW TEMP. FREEZERS SPECIFICATIONS FEATURES DIMENSIONS LOADING QUANTITIES BIOMEDICAL SOLUTIONS

Review of Test Methods for Determination of Low-Temperature Properties of Elastomers

ECO INSTRUMENT (NS M)

Model KB 720 Cooling incubators with compressor technology

Model KT 115 Cooling incubators with thermoelectric cooling

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

SECURE.GUARD Ultra low temperature freezer

Servo-hydraulic Universal Testing Machine HUT Type B

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

Corrosiveness to copper from Petroleum Products ASTM D130 - EN/ISO216 - IP154 - DIN ASTM D IP112 - ASTM D7095

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Product Information. Aflow extrusion plastometer. Optimum test sequence - time-saving and operator-friendly

Model KB 23 Cooling incubators with compressor technology

Model FD 23 Drying and heating chambers Classic.Line with forced convection

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

HSM58 Universal Material Tester 20kN

Corrosiveness to Copper from Petroleum Products ASTM D130 - EN/ISO IP DIN ASTM D IP ASTM D7095.

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

SERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES A

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Environmental simulation chamber for cyclical temperature

Drop Weight Impact Testing Machine DIT183E 1800J

Corrosiveness to Copper from Petroleum Products ASTM D130 - EN/ISO IP DIN ASTM D IP ASTM D7095.

CONTENTS CONTENTS

Transport Boxes. Active & Passive. Biomedical Refrigeration I MT. Technology for life

Innovation in distillation. Pam v2. Automatic Distillation

PF-DETERMINATION (SANDBOX METHOD)

WDW-100 Computerized Electronic Universal Testing Machine

FITOCLIMA 600 & 1200 BIO

BMS-300 / BMS-300E Computerized Electronic Universal Testing Machine

BMS-500 / BMS-500E Computerized Electronic Universal Testing Machine

16CS. Double acting Compressed air to 60 M LED (ON lighting) 980m/s 2

EC medium pressure axial fans. The efficient system solution.

CHL Laboratory refrigerators

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

Automatic Foam Hardness Tester. PC computer controlled. High specification

SPECIFICATION SHEET. Measurement method. Measurement range switching. cell. 1 /2 inch dia ppm. cylinder cell. 1 /4 inch dia.

Anyvib Vibration Test Chambers

Computer Servo Control Tensile Tester

AS950 REFRIGERATED SAMPLER

Rubber Hardness: Gibitre developments and technical market tendencies

Model BF 56 Standard-Incubators with forced convection

TB-AB AQUA. The most thermally efficient, robust and reliable marine incinerators on the market. Simply Built Better! TB-AB Aqua.

FITOCLIMA 600 & 1200 BIO

EXPRESSION OF INTREST

FITOCLIMA WALK-IN STABILITY

FITOCLIMA WALK-IN STABILITY

Model BF 720 Incubators Avantgarde.Line with forced convection

EC medium pressure axial fans.

Degassed Cation Conductivity

Automatic Isokinetic Sampler ST5

THS 21 SERIES. Quality Control at its finest CONVEYOR INSPECTION SYSTEMS FEATURES. Supermarket specifications compliant

HLAG/HLBG Series. Specifications. Switch specifications. Thin parallel hand with rubber cover (bush type/bearing type) Double acting

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

CYTOPERM 2 CO 2 - AND CO 2

Model FDL 115 Safety drying chambers for limited quantities of solvent

Rockwell Hardness Meter TRHM-A10 Rockwell Hardness Meter TRHM-A11 Rockwell Hardness Meter (motorized type) TRHM-B10

Model BF 260 Incubators Avantgarde.Line with forced convection

High Speed... Rapid Temperature Change Rates with VTS & VCS Stress Screening Systems

testo 175-T1 testo 175-T2 1 channel temperature logger with internal sensor 2 channel temperature logger with internal sensor/external probe socket

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

ADVANCED. Rubber Process Analyzer RPA9000.

Cupping and. Deep Drawing Cup Test. Test Machine, Model 242-Basic. testing equipment for quality management. Square Cup Test

TECHNICAL SPECIFICATION SDI C. Automated Ultrasonic Heavy Duty Cylinder Inspection System

Largo & Allegro. Air Compressors. Largo & Allegro

Schleibinger Geräte Teubert u. Greim GmbH

EQJW 126: Heating controller with digital user interface, equitherm

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

LIQUID METER TYPE FMO

Kinematic Viscosity Viscometer

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

SM-220-MP SHOCK TEST MACHINE. Halfsine. Sawtooth. Squarewave

Combustion Laboratory Unit C492

PORTABLE HARDNESS TESTER

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

The World s First Servo Ultrasonic Spot Welder. Dynamic Force and Amplitude Control with Multi-Step Welding

3 Coating thickness. Quick-Finder Coating thickness. Do you have questions about SAUTER coating thickness? SAUTER Model

Automated Mercury/Non-mercury Intrusion Porosimeter AMP-60K-A-1

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable with pressure gauge ATEX certified

6810/15.02 RIVTAC. The innovative high-speed joining process

OPSIS LiquidLINE KjelROC Analyzer

CCR3 Controller - return temperature controller & temperature registration

The Stress Limit for your products. Temperature Shock Test Chamber Model TS 130. Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

Pendulum Impact Testing Machine PIT752H 750J

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

OPSIS LiquidLINE KjelROC Analyzer

OPSIS LiquidLINE KjelROC Analyzer

FREE FORM precision tools

Bringing good things ahead

USTER CLASSIMAT 5. Instrument for classification and analysis of yarn faults in staple yarns. Technical Data

Transcription:

Low Temperature Testers For rubber materials there are four important standardised test methods for Low Temperatures. 1. TR test according to ISO 2921. This method determines the low temperature characteristics by thetemperature retraction procedure. The values TR 10 and TR 30 are often used in material specifications. The software can present a curve with the elastic retraction up to 70%. 2. Gehman test according to ISO 1432. This method measures the relative stiffness as a function of the temperature. The result is presented as the relative stiffness where the stiffness in RT is 1. If the test piece dimension are put into the software it can also calculate the modulus as a function of temperature. 3. Brittleness test according to ISO 812. This method determines the lowest temperature at which rubber materials do not exhibit brittle failure when impacted under specified conditions. 4. Low Temperature Compression Set according to ISO 815-2. This test measures the elastic recovery after a test piece has been held compressed at low temperature for some time. TR and Gehman combined DB.Low.temp_05_1305 Combinations The TR-Tester, Gehman Tester and Brittleness Tester can be combined using the same base unit and a rig changing system. The combined instrument consists of a base unit with a cooling bath and the electronics. The three different test rigs are then mounted on a carousel. No lifting is necessary when switching from one method to another. An automatic computerised Low Temperature Tester increases the precision up to 5 times. The capacity will also increase with about 50 % and not least the labour time will decrease about 75 %. Brittleness and TR combined Elastocon AB. Tvinnargatan 25. SE-507 30 BRÄMHULT. Sweden. Phone +4633-22 56 30. Fax +4633-13 88 71 E-mail: info@elastocon.se. www.elastocon.se

TR Tester, ET 01 for determination of low temperature retraction Combined instrument TR Tester, ET 01, for determination of low temperature characteristics by the temperature retraction procedure according to ISO 2921 and ASTM D-1329. The Elastocon TR Tester, has 6 test stations, is computerized and performs the test automatically after the cooling media has been cooled down, and the samples have been mounted. An automatic release of the samples, after the precooling period, is included. The computer controls both the temperature rise and measures the length change of the samples. The results are displayed in a graph and TR 10, TR 30, TR 50 and TR 70 values are calculated. The result can also be presented as a table with length change versus temperature. The TR-values and the table values can be exported to other software such as spreadsheets. As an option, an automatic cooling system with liquid Nitrogen can be supplied.

Gehman Tester, ET 02 for determination of the relative stiffness characteristics Gehman Tester, ET 02 for determination of the relative stiffness characteristics of vulcanized or thermoplastic rubbers, also called the Gehman procedure. The test is done according to ISO 1432, ASTM D1053, or technical equivalent standards. The Elastocon Gehman Tester, has 6 test stations, is computerised and performs the test automatically. The computer controls both the temperature rise and measures the torsion angle of the samples. The results are displayed in a graph and RM 2, RM 5, RM 10 and RM 100 values are calculated. The result can also be presented as a table. As an option, an automatic cooling system with liquid Nitrogen can be supplied. The photos shows a combined instrument

Brittleness Tester, ET 05 Combined instrument Elastocon Brittleness Tester, ET 05, for automatic determination of Brittleness point according to ISO 812, ISO 974, ASTM D746 and ASTM D2137. The price includes the instrument and software, but not the computer. The test rig is raised by pneumatic cylinders, which require an air supply of 6 Bar. The brittleness tester is designed as a falling weight tester, where the speed is set by the height and the energy by the attached weights. The computer controls the temperature rise and measures the temperature at impact. The result from each stroke is entered by typing the result in the software. The speed is measured after the impact, to verify the speed loss during impact.

Low Temperature Compression Set Rig, EV 09 Low Temperatures Compression Set (LTCS), EC 10 The test rig in the Freezer ET 03 adapted for Low Temperature compression set. Performing compression set at low temperatures without having to open the deepfreezer and influence the compression set result has always been a problem. By using our EV 09 compression rig in combination with a deep-freezer with a special lid the test can be performed without touching the test piece. All adjustments of height and releasing the compression are made outside the freezer thus improving the accuracy of the test results. The EV 09 rig has a digital gauge (0,001 mm), the piston is made of titanium and the test weight is simply mounted on to the titanium piston. The sample can remain in the test rig for the whole test period and during the recovery time. The system is a complete system with rigs, a special adapted deep-freezer and logging software. The values can also be recorded manually. This software can monitor the temperature during the test time and records the recovery when the test piece is released. By setting evaluation points, the results at 30 s, 30 min etc can be presented as well as a graph of the compression set as a function of time. Lab Freezer ET 03 with ET03.01 Conversion kit

Technical Specifications, TR Tester, ET 01 and Gehman Tester, ET 02 Temperature control ET 01 ET 02 Temperature range, C: -80 to + 30-80 to + 30 Accuracy, C: ± 0,5 ± 0,5 Resolution, C: ± 0,1 ± 0,1 Sensor: Pt 100, 1/3 DIN Pt 100 1/3 DIN Length measurement Angle measurement Indicators, no: 6 pc digital encoders 6 pc digital encoders Resolution, mm (ET 01) (ET 02): 0,04 0,2 Measuring range, mm (ET 01) (ET 02): 0-150 0-182 (1) Test rig Rig material: stainless steel and aluminium stainless steel and aluminium Specimen sizes, mm: 25 to 100 Max extension %: 250 (with 50 mm test piece) Min/max test samples, mm: - l x w x t, 40 ±2,5 x 3 ±0,2 x 2 ±0,2 Test stations: 6 6 Other specifictions Dimensions, external, w x h x d, mm: 630 x 1 100 (1 420) (2) x 710 630 x 1 010 (1 260) (2) x 710 Weight, kg: approx 40 46 Cooling liquid volume, l: about 8 about 8 Voltage, V: 220-240 VAC 50/60 Hz (alt 110-120 VAC) 220-240 VAC 50/60Hz (alt. 110-120 VAC) Power, W: 600 600 Air supply, Bar: 4-6 4-6 Computer connection: USB USB Standards: ISO 2921, ASTM D 1329 ISO 1432, ASTM D 1053 1) Testing range adjustable from 0-182. Adjusted at 0-180. 2) Test rig in raised position Common specifications: The casing consists of steel, painted with epoxy paint. The rig is raised with the help of a pneumatic cylinder. Temperature controller with 0,1 C setpoint and RS232 interface. Solid state relay for safe control. Temperature sensor close to the samples. Run-time meter. ET 01.01 Windows software for the TR-tester is included. Windows XP, Win 7 or Win 8 is required. Computer included Options ET 01.02 Automatic cooling by liquid Nitrogen ET 02.03 Grips for O-rings (both whole and cut) Options ET 01.02 Automatic cooling by liquid Nitrogen ET 02.02 Grips for ASTM D1053 method B Result from three materials with double test pieces Result from three materials with double test pieces ELASTOCON reserve the right to modify these specifications in part or in whole.

Technical Specification, Low Temperature Brittleness Tester, ET 05 Temperature control Temperature range, C: -80 to + 30 Accuracy, C: ± 0,5 Resolution, C: ± 0,1 Sensor: Pt 100, 1/3 DIN Speed measurement Indicators: digital encoder Resolution, m/s: 0,01 Test rig Rig material: stainless steel and aluminium Specimen types: A and B (ISO 812) Test pieces, no: 6 Other specifictions Dimensions, external, w x h x d, mm: 630 x 1 100 (1 420) (1) x 710 Weight, kg: approx 40 Cooling liquid volume, l: about 8 Voltage, V: 220-240 VAC 50/60 Hz (alt 110-120 VAC) Power, W: 600 Air supply, Bar: 4-6 Computer connection: USB Standards: ISO 812, ISO 974, ASTM D 746, ASTM D 2137 1) Test rig in raised position Common specifications: The casing consists of steel, painted with epoxy paint. The rig is raised with the help of a pneumatic cylinder. Temperature controller with 0,1 C setpoint and RS232 interface. Solid state relay for safe control. Temperature sensor close to the samples. Run-time meter. ET 05.01 Windows software for the Brittlenes-tester is included. Windows XP, Win 7 or Win 8 is required. Computer included. Brittleness test report File name Date Sample ID. Remarks Test series 1 Test series 2 Test series 3 Test series 4 Test series 5 Test series 6 Test_run01.frz mer. 4 févr. Test_run01 Method B Method C Tb50 C P/F -47,7 - - 100,0 Failure in % 90,0 80,0 70,0 60,0 50,0 REGTb = -48,24 C @ 50 % 40,0 30,0 20,0 10,0 0,0-80,0-60,0-40,0-20,0 Elastocon AB 0,0 Temperature C Elastocon Freezing ELASTOCON reserve the right to modify this specification in part or in whole.

Technical specification Low Temperature Compression Set Rig, EV 09 Range, mm: 12,7 Accuracy, mm: ± 0,003 Resolution, mm: 0,001 Dimensions, dia x h, mm: 120 x 450 Weight, kg: approx 6 Material: stainless steel Temperature sensor: Pt 100, 1/3 DIN Standard: ISO 812-2 The test rig is equipped with a digital gauge connected to a PC for recording of the creep. Lab Freezer ET 03 with ET03.01 Conversion kit ET 03 Low temperature freezer -45 C Model ET 03 Net volume, l: 130 Insulation thickness, mm: 100 Outer dimensions: Height, mm: 850 Width, mm: 725 Depth, mm: 655 Inside dimensions: Height, mm: 650 Width, mm: 520 Depth, mm: 450 Weight, kg: 43 Temperature, C: -10 to - 45 Ambient temperature, C: +10 to +30 Time to reach minimum temp, h: 3 Noise level, dba: < 48 Energy consumption, W: 500 Common specifications: Acoustic alarm. Large temperature display. Digital temperature controller 0,1 C. Handle with key lock. Defrost water drain hole. One stage compressor ensures high level of reliability. Environmental friendly HC refrigerant. 100 mm high performance insulation. CE -marked. ELASTOCON reserve the right to modify these specifications in part or in whole. Elastocon AB. Tvinnargatan 25. SE-507 30 BRÄMHULT. Sweden. Phone +4633-22 56 30. Fax +4633-13 88 71 E-mail: info@elastocon.se. www.elastocon.se