Hydrogen Generators Flow Capacities up to 500 cc/min

Similar documents
Hydrogen Generators for Fuel Gas

Analytical Gas Systems Product Catalog

Ultra High Purity Hydrogen Generators

Gas Generators. Parker Balston

VWR ANALYTICAL GAS GENERATORS FOR CHROMATOGRAPHY APPLICATIONS

Analytical Gas Systems Products for Chromatography

FT-IR Purge Gas Generators

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Hydrogen Generators. Zero Air Generators

TRACE ANALYTICAL. ta7000 Series UHP Gas Purity Monitors At the critical link in your manufacturing process. Features /Benefits

ANALYTICAL GAS GENERATORS INNOVATIVE GAS SOLUTIONS FOR YOUR LAB

ANALYTICAL GAS GENERATORS

Gas Filtration Catalogue

Hydrogen Generators. for GC combustion detector applications. Product Features: Contact Information: ENGINEERING YOUR SUCCESS.

Super Clean Gas Filters Simply the best

Super Clean Gas Filters Simply the best

ON-SITE GAS SOLUTIONS FROM PROTON ONSITE

Dräger Gas Filtration SUPER CLEAN GAS FILTERS. Dräger: Technology for Life

Nitrogen N341M. Laboratory Nitrogen Gas Generator. Technical Features

Compressed Air Filters Sample Filters

APPLICATIONS BENEFITS INTELLIGENT

Super Clean TM Gas Filters

PURELAB Chorus 2 Innovation and Flexibility

OXYGEN TRAPS MOISTURE

Laboratory Gas Generators

MATERIALS OF CONSTRUCTION

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator

0.01 Micron Membrane Filters

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

Elix Gulfstream Clinical Water Purification System

Del-Monox Breathing Air Purifiers DM Series

Equipment. Description. Features. Ordering Information. indicating oxygen trap Series 6200

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

Heated FID OVF Portable THC/TVOC Analyzer

arium mini Ultrapure Water System

PROCESS ANALYZERS FOR PURIFIED BULK GAS QC/QA: ENTERING THE PPT RANGE

REVERSE OSMOSIS WATER TREATMENT

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Using the PPM2 Portable Trace Moisture Transmitter

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

VWR Zero Air Generator Models , Installation, Operation, and Maintenance Manual. Bulletin TI-ZAG3500-L1466

WATER SYSTEMS FOR AQUAPONICS MAXQUARIUM 000PPM. Ultra-Pure Reverse Osmosis/Deionization Water System Up to 500 L/D of Pure Water

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

Aeronex Gas Purification System HX Series

PURELAB Chorus. Solutions for Type I Ultrapure Water

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Technical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply.

Purite Water Purification Systems

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

PURELAB Chorus. Solutions for Type I Ultrapure Water

PURELAB CHORUS SYSTEMS

Expand your Nitrogen Production Flexibility and Decrease Cost of Ownership... Now and in the Future.

Compressed Air Filters 1/4 and 1/2 Line Size Filters

GROWMAX WATER Perfect Water for Plants and Gardens

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Atlas Copco. Quality Air Solutions Compressed Air Filters

Compressed Air Systems. Compressed Air Filters. Balston Microfiber Filter Assemblies. Product Features

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

PURELAB CHORUS SYSTEMS

ANALYZER WATER SYSTEMS MEDICA. Water purification systems for clinical analyzers. Pure Water, Pure Science, Pure Service

i-flow Scalable, high-flow, nitrogen generation solution for industry

i-flow Scalable, high-flow, nitrogen generation solution for industry

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001

PRIMARY GRADE WATER L A B W A T E R. PURELAB TM Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists


MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Installation. Basic Rack Power Distribution Units AP9560 AP9561

D DAVID PUBLISHING. Hydrogen Gas Purifiers for Fuel Cells. 1. Introduction. 2. Scientific Approach

Applications A Balston Nitrogen Generator Food Industries Purging and blanketing Packaging/mixed gas Preservation Color retention Processing/mixing Pr

Del-Monox Breathing Air Purifiers

Chloride/Sulfate Analyzer

AP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM

rios Water Purification system The standard for laboratory-grade water

The Culligan Hi-Flo 50 Series Industrial Water Filter System

RiOs 3, 5, 8 Water Purification Systems

RiOs 3, 5, 8 Water Purification Systems

ANALYZER WATER SYSTEMS MEDICA. Water purification systems for clinical analyzers. Pure Water, Pure Science, Pure Service

H-100 Fuel Cell Stack User Manual

H-300 Fuel Cell Stack User Manual

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

Pure and ultrapure laboratory water from a single system

Betapure CMP Series. CMP Filter Capsules. Superior Reduction Of Large Particle Counts For Improved Yields. Features & Benefits.

Type I. Features and Benefits 18+ Megohm-cm Type I reagent grade water. AQUA SOLUTIONS Type I. Reagent Grade DI Systems

NITROGEN SERIES COMPRESSOR SYSTEMS

DELIVER EXTREMELY CLEAN WATER TO YOUR ULTRASONIC HUMIDIFICATION EQUIPMENT

Measuring moisture in ultra-high-purity gases

Your local gas generation partner. i-flowlab. Scalable, high-flow, high-purity nitrogen gas solution for laboratories.

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Filters & Elements. People. Passion. Performance

AFS 8D / 16D Degassed Water Purification Systems

EC5B. PEM Fuel Cell Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console. Engineering and Technical Teaching Equipment

L A B W A T E R ULTRA-PURE WATER. PURELAB Ultra. Ultra-Pure Water Polishing System. The Laboratory Water Specialists

Degassed Cation Conductivity

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Atlas Copco Quality Air Solutions. Compressed Air Filters

Transcription:

up to 500 cc/min Eliminates dangerous hydrogen gas cylinders from the laboratory Safe - produces only as much gas as you need Produces a continuous supply of 99 9999% pure hydrogen gas at 6.9 barg Designed to run continuously 24 hours/day Simple maintenance Certified for laboratory use by CSA, UL, IEC 1010, and CE Marked Hydrogen On Demand, Up to 500 cc/minute Ultra high purity (UHP) hydrogen generators from Parker are designed as hazard-free alternatives to high-pressure gas cylinders. They can be used with any instrumentation requiring high purity hydrogen anywhere a standard electrical supply is available. Deionized water is all that is required to generate hydrogen for weeks of continuous operation. With an output capacity of up to 500 cc/minute, one generator can now supply 99.9999% pure carrier gas to several GC s, and fuel gas to 12 FID s. Based on cylinder gas savings alone, a Parker Balston hydrogen generator can pay for itself in less than a year. Certified Safety Parker s hydrogen generators use an exclusive Proton Exchange Membrane to produce hydrogen on demand. Only 100 ml is stored in the system at any time and at low pressure. A built-in sensing circuit shuts the generator down if a hydrogen leak is detected. That s why Parker hydrogen generators meet the strict, safety guidelines of the National Fire Protection Agency (NFPA) and the regulations of the Occupational Safety and Health Association (OSHA - 1910.103). Most importantly, they are the only hydrogen generators certified for laboratory use by CSA, UL and IEC 1010. Compliance with European regulations means generators are CE marked. Proven Technology Parker s exclusive Proton Exchange electrolyte Electrolyzer eliminates the use of liquid electrolytes with hydrogen generators. Proven in over 20,000 GC installations worldwide, Parker s generators are the most reliable hydrogen generators on the market. Maintenance requires only a few moments per year no inconvenient, extended downtime. Simply change the deionizer bag every six months and the desiccant cartridge whenever it turns beige. And if contaminated water or low water level is detected, the system activates a warning light and shuts off the generator avoiding damage to the electrolytic cell.

up to 500 cc/min Hydrogen Generator 9000 Series Model 9090 9150 9200 9400 Purity 99.9999% 1 99.9999% 1 99.9999% 1 99.9999% 1 Flow Rates 90 cc/minute 160 cc/minute 250 cc/minute 500 cc/minute Outlet Port 1/8 compression 1/8 compression 1/8 compression 1/8 compression Electrical 234 Vac 234 Vac 234 Vac 234 Vac Delivery Pressure 0 to 2 barg ±3% 0 to 2 barg ±3% 0 to 2 barg ±3% 0 to 2 barg ±3% 2 to 6.9 barg ±2% 2 to 6.9 barg ±2% 2 to 6.9 barg ±2% 2 to 6.9 barg ±2% Pressure Control 0.3 to 1.3 barg ±0.5% 0.3 to 1.3 barg ±0.5% 0.3 to 1.3 barg ±0.5% 0.3 to 1.3 barg ±0.5% 1.3 to 6.9 barg ±0.2% 1.3 to 6.9 barg ±0.2% 1.3 to 6.9 barg ±0.2% 1.3 to 6.9 barg ±0.2% Shipping Weight 18 kg dry 18 kg dry 18 kg dry 18 kg dry Dimensions 378x333x359 mm 378x333x359 mm 378x333x359 mm 378x333x359 mm 1 With respect to Oxygen Model Number 90 cc/minute A909000-220 160 cc/minute A915000-220 250 cc/minute B920000-220 500 cc/minute B940000-220 Dessicant cartridge (1 each) 1647727 Deionizer bags (2 each) 7601132 * For 110 Vac versions contact Parker reserves the right to make product changes without notice. No liability is accepted for any consequential losses, injury or damage resulting from the use of this document or from any omissions or errors herein. The data is given for guidance only. It does not constitute a specification or an offer for sale. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics quoted. As the products may be used by the client in circumstances beyond the knowledge and control of, we cannot give any warranty as to the relevance of these particulars to an application. It is the client s responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their safety of operation in a particular application. HY-GEN500 1.0 JULY 03

up to 300 cc/min Eliminates expensive and potentially dangerous hydrogen gas cylinders from the laboratory Automatic water feed standard Exceeds OSHA 1910.103 safety requirements Safe - produces only as much gas as you need Produces a continuous supply of 99 99999+% pure hydrogen gas, ideal for carrier and fuel gas applications Compact and reliable minimal bench space required and designed to run continuously 24 hours/day Simple annual maintenance, no desiccants Certified for laboratory use by CSA, UL, IEC 1010 and CE Marked Parker Balston eliminate the need for expensive, potentially dangerous, high-pressure cylinders of hydrogen in the laboratory. It is no longer necessary to interrupt important analysis to change cylinders. Generator flow capacities of up to 300 cc/min of ultra high purity hydrogen are available. The Parker Balston are compact benchtop units designed for use in the laboratory or in the field. Hydrogen gas is produced by electrolytic dissociation of water. The resultant hydrogen stream then passes through a palladium membrane to assure carrier grade purity. Only hydrogen and its isotopes can penetrate the palladium membrane; therefore, the purity of the output gas is 99 99999+% consistently. This technology produces hydrogen at a purity two orders of magnitude greater than desiccant or silica gel technologies. Parker Balston offer many special features to ensure safe and convenient operation. These features include low-water audible alarms to indicate when the water reservoir needs filling and automatic shutdown to protect expensive laboratory equipment. The Parker Balston Hydrogen Generator is an excellent source of ultra pure, dry hydrogen for a wide range of laboratory uses. The generator is used extensively with Gas Chromatographs, as a fuel gas for Flame Ionization Detectors (FID), as a reaction gas for Hall Detectors, and as a carrier gas to ensure absolute repeatability of retention times. In high sensitivity Trace Hydrocarbon Analyzers and air pollution monitors, the hydrogen produced ensures the lowest possible background noise. Other applications include using hydrogen for hydrogenation reactions and for FID s used in the analysis of engine gas emissions in the automobile industry. In all applications the Parker Balston Hydrogen Generator sets the standard for safety, operational performance, and dependability.

up to 300 cc/min Hydrogen Purity 99.99999+% <0 01 ppm Oxygen Content <1 0 ppm Moisture Content Max Hydrogen Flow Rate H2-150 150 cc/min H2-300 300 cc/min Electrical Requirements (1) 240 VAC/60 Hz Hydrogen Outlet Pressure Adjustable, 0 to 4 1 barg (0 to 60 psig) Certifications IEC 1010-1; CSA 1010; UL 3101; CE Mark Dimensions 300 x 330 x 580 mm (12 x 12 x 22 ) Outlet Port 1/8 Compression Shipping Weight 26 kg (58 lbs) Notes: 1 Generator models for operation with other global electrical supplies available. Please contact your local representative Model Number Hydrogen Gas Generator H2-150 H2-300 Electrolyte Solution REAG-920071 Installation Kit IK7532 reserves the right to make product changes without notice. No liability is accepted for any consequential losses, injury or damage resulting from the use of this document or from any omissions or errors herein. The data is given for guidance only. It does not constitute a specification or an offer for sale. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics quoted. As the products may be used by the client in circumstances beyond the knowledge and control of, we cannot give any warranty as to the relevance of these particulars to an application. It is the client s responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their safety of operation in a particular application. HY-GEN 1.0 JULY 03

R HydroGen Mate DI Water System Economical means of providing deionized water to hydrogen generators Minimal maintenance Visual indication for cartridge changes Easy fill dispensing gun Removal of organics, phosphates, chlorine and essentially all ionizable constituents from your water supply Quick and easy installation No electrical requirements Parker Balston Deionized Water Systems The Parker HydroGen Mate DI Water System is specifically designed to provide high purity deionized water to all types of Parker hydrogen generators. The system is ready to install and is shipped complete with prefiltration, two DI resin exchange cartridges, dispensing gun and a final filter. The only required maintenance on the system is to change the resin non-exchange cartridges and to replace the filter cartridges as needed. Parker Balston Type 72-230 HydroGen Mate DI Water System 72-230 Type 72-230 DI Water System Maximum Flow Rate: 1 lpm Water Inlet: 1/4" "Push to connect" Maximum Water Supply Pressure: 3.4 barg Maximum Water Supply Temperature: 27 C Physical Dimensions: 310mm x 460mm x 70mm Shipping Weight: 5.5kg Type Number Complete DI Water System ready to install 72-230 Maintenance Kit 72236 reserves the right to make product changes without notice. No liability is accepted for any consequential losses, injury or damage resulting from the use of this document or from any omissions or errors herein. The data is given for guidance only. It does not constitute a specification or an offer for sale. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics quoted. As the products may be used by the client in circumstances beyond the knowledge and control of, we cannot give any warranty as to the relevance of these particulars to an application. It is the client s responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their safety of operation in a particular application. P-72230 ISSUE 4.0 OCT 02 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balston/ags