Nonlinear Seismic Response Analysis for Hong Kong-Zhuhai-Macau Bridge

Similar documents
Effect of Curvature and Seismic Excitation Characteristics on the Seismic Response of Seismically Isolated Curved Continuous Bridge

STUDY ON SHAKING TABLE TESTS OF ISOLATED BRIDGE MODEL WITH LRB

SOIL STRUCTURE INTERACTION EFFECTS ON BASE ISOLATED BRIDGES

3-D finite element analysis on shear lag effect of curved box girder under multi-dimensional seismic excitation

MULTI-LEVEL FORTIFICATION INTENSITIES SEISMIC PERFORMANCE ASSESSMENT FOR REINFORCED CONCRETE FRAME- SHEAR WALL STRUCTURE WITH VISCOUS DAMPERS

Stiffness optimized research of high damping rubber bearing for beam bridges

Earthquake Response Analysis of Spherical Tanks with Seismic Isolation

Analysis of seismic mitigation elastic-plastic passive control for. continuous beam bridge *

Optimal allocation and seismic isolation effect analysis of high-damping rubber bearing for Beam Bridge

Seismic Response of Cooperative System Bridge under Pile-Soil-Structure Interaction

Dynamic Characteristics Analysis of Large Self-anchored Suspension Bridge

Study on Shear Lag Effect of Composite Box Girder Bridge with Corrugated Steel Webs

Anti-fatigue Performance Analysis on Steel Crane Beam

Case Study: Challenges of a Single-layer Reticulated Dome

COMPARATIVE ANALYSIS OF SEISMIC ISOLATED SYSTEMS IN BRIDGES

NONLINEAR DYNAMIC BEHAVIOR AND SEISMIC ISOLATION OF STEEL TOWERS OF CABLE-STAYED BRIDGES UNDER GREAT EARTHQUAKE GROUND MOTION

Influence of Passive Isolator Parameters on Seismic Response Control of Multi-Span Bridges

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume X, No X, 2010

The Effect of Seismic Isolation on the Dynamic Behavior of Cable-Stayed Bridges

SEISMIC DESIGN OF STRUCTURE

0306 SEISMIC LOADS GENERAL

Research on the Seismic Performance of an Externally Prestressed Rocking Reinforced Concrete Frame

ANALYSIS OF 3-D VIBRATIONS OF THE BASE ISOLATED SCHOOL BUILDING "PESTALOZZI" BY ANALYTICAL AND EXPERIMENTAL APPROACH

Nonlinear Finite Element Analysis of the Steel-concrete Composite Beam to Concrete-filled Steel Tubular Column Joints

SEISMIC RESPONSE OF A REINFORCED CONCRETE ARCH BRIDGE

Seismic Safety Evaluation of Bridge Structures Based on Inelastic Spectrum Method

Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting

Structural Design of Super High Rise Buildings in High Seismic Intensity Area

Application of Isolation Technology in High-voltage Electrical Equipments

Dual earthquake resistant frames

Vibration control of a building model with base isolation

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

Seismic behavior of concrete structures equipped with ADAS devices

Title. Author(s)BAI, DI; HAYASHIKAWA, T.; MATSUMOTO, TAKASHI; HE, XI. Issue Date Doc URL. Type. Note. File Information

Modeling and Design of Bridge Super Structure and Sub Structure

ICSS(4): A DESIGN APPLIED FOR A SUPER LONG MULTI-SPAN BRIDGE

INELASTIC SEISMIC PERFORMANCE OF RC TALL PIERS WITH HOLLOW SECTION

Seismic Response Analysis of a Concrete Filled Steel Tubular (CFST) Arch Bridge

ANALYSIS AND ASSESSMENT OF ARTICULATED SKEW HOLLOW SLAB BEAM BRIDGE

Seismic Fragility Based Optimum Design of LRB for Isolated Continuous Girder Bridge

Rong He School of Civil Engineering and Communication, North China University of Water Resources and Electric Power, Zhengzhou, , China

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

The Investigation of Earthquake Resistance for the PC continuous Rigid Frame Bridge considering Nonlinearity in Superstructure

STUDY ON THE DAMAGES OF STEEL GIRDERS BY HYOGO-KEN NANBU EARTHQUAKE USING NONLINEAR SEISMIC RESPONSE ANALYSIS

Kiran K. Shetty & Krishnamoorthy Department of Civil Engineering, Manipal Institute of Technology, Manipal , Karnataka, India

ANALYTICAL STUDY OF AN ISOLATED AND NON-ISOLATED BRIDGE

SEISMIC BEHAVIOR OF NEW VISCO PLASTIC DEVICE EQUIPPED WITH STEEL CORES AND VISCOELASTIC SOLID

VERTICAL COMPONENT EFFECT OF EARTHQUAKE IN SEISMIC PERFORMANCE OF REINFORCED CONCRETE BRIDGE PIERS

Modeling of Reinforced Concrete Folded Plate Structures for Seismic Evaluation Swatilekha Guha Bodh

Response Analysis of an RC Cooling Tower Under Seismic and Windstorm Effects D. Makovička

Proceedings of the 3rd International Conference on Environmental and Geological Science and Engineering

Basarab Cable Stayed Bridge in Bucharest

Seismic Control of Continuous Bridges Using Variable Radius Friction Pendulum Systems and Viscous Fluid Dampers

EFFICIENCY OF USING VISCOUS DAMPERS FOR MULTI-STOREY STEEL STRUCTURES SUBJECTED TO SEISMIC ACTIONS

RESILIENT INFRASTRUCTURE June 1 4, 2016

SEISMIC DAMAGE DUE TO CURVATURE EFFECT ON CURVED HIGHWAY VIADUCTS

Load capacity rating of an existing curved steel box girder bridge through field test

SHAKE TABLE TESTING OF BRIDGE REINFORCED CONCRETE COLUMNS UNDER COMBINED ACTIONS

Research on seismic performance of design detailing based segmental prestressed concrete bridge pier

Research on seismic safety, retrofit, and design of a steel cable-stayed bridge

STUDY ON MODELING OF STEEL RIGID FRAME BRIDGE FOR DYNAMIC ELASTO-PLASTIC ANALYSIS

SEISMIC DESIGN OF MULTI SPAN CONTINUOUS RIGID-FRAME BRIDGE WITH PRESTRESSED CONCRETE BOX GIRDER NEW-TOMEI GUNKAI-GAWA BRIDGE

Truss Analysis for Evaluating the Behavior of Reinforced Concrete Moment-Resisting Frames with Poorly Reinforcing Details

Design and construction of Hechang Bridge, Quanzhou, China

Seismic Assessment of Traditional Masonry-Wooden Building in Taiwan

Comparisons of Current Seismic Assessment Methods for Non-Seismic Designed Reinforced Concrete Bridges

Experimental and theoretical study on softening and pinching effects of bridge column

Nonlinear Dynamic Analysis of Base Isolated Reinforced Concrete Building

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Influence of arch bridge skewness

Behavior of Steel Beam to Concrete Filled Tubular Steel Joints after Exposure to Fire

Numerical Simulation on Dynamic Behavior of a Cold-Formed Steel Framing Building Test Model

Research on the Influence of Infill Walls on Seismic Performance of Masonry Buildings with Bottom Frame-Shear Walls

CALTRANS SDC PROCEDURE

Analysis of a Multi-Tower Frame Structure connected at different levels using ETABS

Effectiveness of Base Isolation Technique and Influence of Isolator Characteristics on Response of a Base Isolated Building

Free vibrations and seismic responses of Shin Saikai Bridge and Saikai Bridge

Research on Seismic Behavior of honeycomb composite beamcolumn

EXPERIMENTAL STUDY ON FLEXURAL BEHAVIOR OF RC BEAMS STRENGTHENED WITH SMPM

Nonlinear Shear Buckling Parametric Finite-Element Analysis of Corrugated Steel Webs

Seismic devices for bridges

Analysis and Research on Deformation Monitoring of Large Span Cable-stayed Bridge during Operating Period

Performance Improvement of Tall Reinforced Concrete Structures with Multiple Tuned Mass Dampers (MTMD)

Research on Bending Bearing Capacity of Simply Supported Reactive Powder Concrete Beams

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

Dynamic Stability of Elastomeric Bearings at Large Displacement

Fragility Curves for Seismically Retrofitted Concrete Bridges

Parametric Study of Horizontally Curved Box Girders for Torsional Behavior and Stability

Experimental study on shear lag of curved box girder under earthquake excitation

Wire-rope Bracing System with Central Cylinder,

Non-linear Time History Response Analysis of Low Masonry Structure with tie-columns

PSEUDO-DYNAMIC TEST AND NON-LINEAR ANALYSIS OF A 1:10 SCALE PRE-STRESSED CONCRETE CONTAIN VESSEL MODEL FOR CNP1000 NUCLEAR POWER PLANT

5th International Conference on Advanced Design and Manufacturing Engineering (ICADME 2015)

Conventional Design Approach Structures : To resist earthquake through strength, ductility & energy absorption Excitations : Inelastic deformation of

Seismic Design and Retrofit. Reginald DesRoches Professor and Associate Chair Georgia Institute of Technology

SEISMIC BEHAVIOR ANALYSIS OF STEEL-CONCRETE COMPOSITE FRAME STRUCTURE SYSTEMS

ON SEISMIC RETROFIT STRATEGIES OF HIGHWAY BRIDGES - EXPERIENCES LEARNED FROM CHI-CHI EARTHQUAKE

Osamu Takahashi, Hiromasa Aida 1 Junji Suhara, Ryoichiro Matsumoto 2 Yasuo Tsuyuki 3 Takafumi Fujita 4. Kozo Keikaku Engineering 2

STUDY ON LAMINATED RUBBER BEARING BASE ISOLATORS FOR SEISMIC PROTECTION OF STRUCTURES

THE EFFECT OF AXIAL COMPRESSION RATIO ON SEISMIC BEHAVIOR OF INFILLED REINFORCED CONCRETE FRAMES WITH PROFILED STEEL SHEET BRACING

Transcription:

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 Sensors & Transducers 214 by IFSA ublishing, S. L. http://www.sensorsportal.com Nonlinear Seismic Response Analysis for Hong Kong-Zhuhai-Macau Bridge * Tao Wang, Yu Li, Jing Ning 1 Key Laboratory for Bridge and Tunnel of Shanxi rovince, Chang an University, Xi an, 7164, China * Tel.: +86-18691897665, fax: +86-29-82336336 * E-mail: 4845664@qq.com Received: 1 May 27 /Accepted: 3 June 214 /ublished: 31 July 214 Abstract: According to the behavior of seismically isolated continuous bridges, the bidirectional nonlinear characteristics of lead rubber bearing are taken into account by using two orthogonal nonlinear level spring elements. Based on the FEA software, the analysis models of seismically isolated and non-isolated continuous bridges are established. And the nonlinear seismic response for these analysis models is carried out under the function of the reasonably chosen seismic motion. The analytic results indicate that the natural period of seismically isolated bridge can be prolonged to avoid the principal period of ground and the seismic energy of structure can be efficiently consumed by the hysteretic energy dissipation of lead rubber bearing. So the response of bridge structure can be reduced to make sure most of the component works in the elastic phase and the structure can be well protected. Copyright 214 IFSA ublishing, S. L. Keywords: Lead rubber bearing, Seismic response, Continuous bridge, Nonlinear analysis. 1. Introduction In recent years, scholars around the world have had extensive studies on the seismic isolation technology [1-9], and many of the bridge structures have been built using this technology. Compared to the traditional non-isolated bridge, the seismic response of seismically isolated bridge and the analysis become more complex [1]: non-isolated bridges are generally used to resist earthquake by enhancing its bearing capacity and deformation, namely, to absorb the earthquake energy relying on the crack and damage of main structural components, which makes sure that the bridge structure can be avoid of collapse, but it will cause serious damage to the bridge. While, in the seismically isolated bridge system, the traditional idea of resisting is changed, by the new approach of softening structure, that is to say, by setting isolation bearing on the top of pier, the purpose of reducing seismic response can be achieved [11, 12]. According to the design characteristics of seismically isolated continuous girder bridge, this article makes use of two orthogonal nonlinear level spring elements to simulate the bidirectional nonlinear feature of the lead-rubber bearings. Based on the FEA software, the analysis models of the seismically isolated continuous bridge and the nonisolated continuous bridge are established. And the nonlinear seismic response for these analysis models is carried out under the function of the reasonably 12 http://www.sensorsportal.com/html/digest/_2232.htm

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 chosen seismic motion. Some useful results are obtained. 2. Basic Mechanics Theory of the Isolated Bridge The seismic isolation technology belongs to the category of structural passive control, which is one important method to reduce the effect from earthquake damage. The basic approach is that: setting the isolation bearing on the top of pier, to make the natural vibration period of the structure prolonged, thus achieve the purpose of reducing the seismic response [12]. Under the action of ground motion, the dynamic equation for the seismic isolation system on a single-particle is mx + cx + kx = cx + kx, (1) s s s g g Both sides of the formula are divided by m, the inherent frequency of seismic isolation system is defined as ω n = k / m, the damping ratio is ξ = c (2 mω ), then equation (1) can be expressed as: n x + 2ξω x + ω x = 2ξω x + ω x, (2) 2 2 s n s n s n g n g In the equation, xs, x s, xs are the structural level absolute acceleration, relative velocity and relative displacement; x g, xg are the ground level earthquake velocity and displacement. The dynamic equation for the seismic isolation system on multi-particles is [ M ] X + [ C] X + [ K] X = ( X + X )[ M], (3) s s s g b Suppose the characteristic frequency matrix is 2 2 2 [ ω] = diag{ ω1, ω2,, ω n }, its corresponding vibration mode eigenvector matrix is [ Φ ], introduce the generalized coordinates {} q, and then the structural displacement response is: { x } = [ Φ ]{ q}, (4) s Substitute Equation (4) into Equation (3), and multiply the both sides by[ Φ ] T, then, T T [ Φ] [ M ][ Φ ]{ q } + [ Φ] [ C][ Φ]{ q } T = ( X + X )[ Φ] [ M], The equation can be formulated as: g * * * T [ M ]{} q + [ C ]{} q + [ K ]{} q = ( Xg + Xb)[ Φ][ M] b (5), (6) In the equation: * T [ M ] =Φ [ ] [ M][ Φ ] * T [ C ] [ ] [ C][ ]{ q} =Φ Φ * [ K ] =Φ [ ] T [ K][ Φ ]{ q} For a vibration mode j, the equation is: q + 2ξωq + ωq 2 j j j j j j n = ( ϕijmi )( X g + X b ), (7) i= 1 In the equation, ξ j is the damping ratio [13] of the vibration mode j. In this paper, the direct integration scheme is used in the study, which needs to input the earthquake waves corresponding to the field where the bridge lies, as the earthquake action, and the step by step integration begins from the original state until the end of the earthquake, thereby we get the dynamic response of the isolated continuous bridge under the earthquake action. 3. Analysis Model of the Isolated Bridge 3.1. roject Situation In the deep water area of Hong Kong-Zhuhai- Macau Bridge, The transition link bridge structure between Qingzhou shipping channel bridges and nonnavigable span bridges has a very big difference with the typical high pier bridge structure and the typical low pier bridge structure. So, although the designer does not make special statement on this in their design report, we think it is necessary to build an independent model for special analysis. It is recommended to adopt the scheme of continuous steel box girder bridge with the span arrangement of (6 11) m, as the transition link bridge between Qingzhou shipping channel bridges and nonnavigable span bridges in deep water area, and make use of the entire hollow thin-walled pier and the foundation form of steel pipe composite pile. The precasting and installation scheme is applied for the construction of the pile cap and the pier body. The pile cap and the first section of pier body are overall precast and installed, and the joint of pier body lies in the splash zone above. For the piers with the height less than or equal to 26 m, it is the low piers zone, while for the piers with the height larger than 26 m, it is the high piers zone. This link bridge unit lies in the transition zone from the nonnavigation span to the Qingzhou Bridge, and the size of pier body varies from the high piers zone to Qingzhou bridge transition pier. In the scheme of steel pipe composite pile part, the variable section pile is adopted. And the wall thickness of the steel pipe is 22 mm. 6 piles are adopted for the foundation of No., 1, 2 piers, the diameter of section with steel pipe is 22 cm, the diameter of section without steel pipe is 2 cm, and 13

()uyubsensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 the pile cap size is 1.6 15.6 4. m. 8 piles are adopted for the foundation of No. 3, 4, 5 piers, and the foundation of No. 6 pier is the pile groups foundation for the Qingzhou bridge transition pier. For steel pipes and concrete of the steel pipe composite pile assume the force together, the anticorrosion measure should be taken on the steel pipes, and the bond behavior of steel pipes and concrete should be ensured. The isolation bearing is adopted. The calculation parameters as follow: the initial stiffness at the place of No. 3 pier is 139,67 kn, the yield force is 279.3 kn, the longitudinal and horizontal yield stiffness ratio is.358; the initial stiffness at the place of No. 2, 4 piers is 17,34 kn, the yield force is 34.7 kn, the longitudinal and horizontal yield stiffness ratio is.294; the initial stiffness at the place of No. 1, 5 piers is 58,89 kn, the yield force is 117.8 kn, the longitudinal and horizontal yield stiffness ratio is.34. Fig. 1 shows the lead rubber bearing bilinear hysteretic model. bfukbq2ykk1bois set up in the pier top, 1/2, 1/4 and 3/4 span positions, I crossbeam is set in 1/8, 3/8, 5/8,7/8 span positions. Box crossbeam has the same height with the main beam, with the beam width 2.56 m, and in the box, the longitudinal flat steel stiffeners and diaphragm are set. I beam has the same height with the box beam, and the width of top and bottom margin plates is.42 m. 3.2. Establishment of the Finite Element Model In the structure analysis, a complete and detailed structure analysis calculation is made on the recommended scheme of variable cross-section steel box girder, variable cross-section pier body and steel pipe composite pile. SA2 3D model that based on spatial pole cells and girder cells is adopted as the calculation model for the dynamic analysis, as shown in Fig. 2 and Fig. 3. Spatial beam element is adopted on the main beam, transversal crossbeam and bridge pier, the elastic linkage pole and rubber isolation element are used to simulate the ordinary bearing and isolation bearing. Suppose that the structure has no obvious support displacement under the action of operating loads, and in the fundamental analysis structure model, the support initial stiffness is used to simulate the support effect. Fig. 1. Lead-rubber bearings bilinear hysteretic model. The span connected the navigation hole linking, Because the total width of navigable span bridge surface is larger than 33.1 m, when connecting it to the non-navigation bridge, the median strip of the span between them should be widened gradually, the box girder is divided into two single box beams along longitudinal symmetric centerline, and the transversal crossbeams are set between two single box beams, to resist the bending moment produced by dead load, live loads and lateral wind load at this. Single box beam has asymmetric box section, and dead load produces the torsion moment on it, to mutually offset by the transversal crossbeams. Under the action of live loads and lateral wind loads, the imbalance torsion moment of single box beam is converted to the bending moment and shear force of the transversal crossbeams. Under the action of the wind loads, the wind pressure is balanced by the space between two box beams, which is helpful for the wind-resistant stability of steel box girder. The transversal crossbeams are two kinds of crosssection, box type and I type, and the box crossbeam Fig. 2. Finite element model. Fig. 3. 3D views local model. 3.3. Earthquake Motion Input According to the exceedance probability of 5 % (3 level) in 12 years, six groups of the time history 14

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 curves of the longitudinal, lateral and vertical seismic ground accelerations of non-navigation bridges in deep water area are input as seismic loads, and one group is shown in the Fig. 4. 3 2 1 3 2 1-1 1 2 3 4 5-1 1 2 3 4 5-2 -2-3 -3 (a) (b) 3 2 1-1 1 2 3 4 5-2 -3 (c) Fig. 4. The time history curves of the longitudinal (a), lateral (b) and vertical(c) seismic ground accelerations under exceedance probability of 5 % in 12 years. 4. Analysis of Calculation Results 4.1. Natural Vibration eriod and Frequency Because different bearings are adopted in the pier tops of the seismically isolated continuous bridge or the non-isolated continuous bridge, they have different natural vibration periods and frequencies under the bidirectional earthquake waves. The calculation results of natural vibration periods and frequencies are shown in the Table 1 and Table 2, and it can be seen that: the natural vibration period of the seismically isolated continuous bridge is much larger than the non-isolated continuous bridge. Table 1. Natural vibration periods and frequencies of non-isolated continuous bridge. Mode eriod/s UX UY Longitudinal Horizontal Features of vibration modes 1 3.58 27 % % First longitudinal bending of pier 2 1.52 1 % % Second longitudinal bending of pier 3 1.42 1 % % Third longitudinal bending of pier 4 1.36 6 % % Fourth longitudinal bending of pier 5 1.36 % 4 % Bending of the main beam Table 2. Natural vibration period and frequency of seismically-isolated continuous bridge. Mode eriod/s UX UY Longitudinal Horizontal Features of vibration modes 1 3.93 28 % % Longitudinal bending of pier 2 3.1 % 21 % Horizontal bending of main beam 3 1.81 % % Antisymmetry bending of main beam 4 1.39 7 % % Longitudinal bending of pier 5 1.36 6 % % Longitudinal bending of pier 15

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 According to the new Code for Seismic Design of Buildings (GB511-21 of China) and related parameters of the calculation analysis model above, the earthquake effect coefficient curve of the second class field is obtained, as shown in Fig. 5. Correspond the natural vibration periods of seismically isolated and non-isolated continuous bridges to the earthquake effect coefficient curve, you can find that: the natural vibration period of seismically isolated continuous bridge keeps away from the principal period of the second class field, so the earthquake action it assumes is much smaller than that of non-isolated continuous bridge. That is to say, the natural vibration period of the bridge structure can be prolonged by the isolation bearings, to achieve the purpose of reducing the seismic response of the structure itself. 4.2. Seismic Response and Isolation Effect Analysis (3 level) The lead core diameter D of the lead-rubber bearings determines the initial shear stiffness and the yield strength of bearings, and also determines the isolation effect. In this paper, it is assumed that the damping ratio of lead rubber bearings is ξ = 5%, the stiffness ratio is η =.15, and the design values of the yield strength and initial shear stiffness corresponding to the lead-rubber bearing with the lead core diameter D = 7mm is adopted, the seismic isolation effectiveness of lead-rubber bearing is researched as shown in Fig. 6, and the seismic response of the seismically-isolated continuous bridge is calculated as shown in Fig. 7 Fig. 11..12 Tg=.4s.1 α.8.6.4.2...5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. T/s Fig. 5. The earthquake effect coefficient curve (II class field). Fig. 6 (a). The hysteresis curve of bearings along the longitudinal and lateral bridge: ier 1 bearing 1-1. Fig. 6 (b). The hysteresis curve of bearings along the longitudinal and lateral bridge: ier 2 bearing 2-1. 16

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 Fig. 6 (c). The hysteresis curve of bearings along the longitudinal and lateral bridge: ier 3 bearing 3-1. Fig. 6 (d). The hysteresis curve of bearings along the longitudinal and lateral bridge: ier 4 bearing 4-1. Fig. 6 (e). The hysteresis curve of bearings along the longitudinal and lateral bridge: ier 5 bearing 5-1. 5 4 3 2 1-1 1 2 3 4 5 6-2 5 4 3 2 1-1 2 4 6 8 1 12 14-2 Fig. 7. The -M relationship chart and -Curvature diagram of pier 1 along the longitudinal and lateral bridge. 17

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 5 4 3 2 1-1 1 2 3 4 5 6-2 5 4 3 2 1-2 -1 2 4 6 8 1 12 14 Fig. 8. The -M relationship chart and -Curvature diagram of pier 2 along the longitudinal and lateral bridge. 6 5 4 3 2 1-1 1 2 3 4 5 6-2 6 5 4 3 2 1-1 5 1 15 2-2 Fig. 9. The -M relationship chart and -Curvature diagram of pier 3 along the longitudinal and lateral bridge. 8 6 4 2-2 1 2 3 4 5 6 7-4 8 6 4 2-4 -2 5 1 15 2 25 Fig. 1. The -M relationship chart and -Curvature diagram of pier 4 along the longitudinal and lateral bridge. 18

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 8 6 4 2-2 1 2 3 4 5 6 7 8 9-4 8 6 4 2-2 5 1 15 2 25 3 35-4 Fig. 11. The -M relationship chart and -Curvature diagram of pier 5 along the longitudinal and lateral bridge. 4.3. Bending Time Histories The bending time-histories of pier bottom under the longitudinal seismic action in 3 level are shown in Fig. 12 respectively. It can be seen from the figures that, the pier bottom shear, pier bottom bending moment and the pier axial force of the seismically-isolated continuous bridge are much lighter than the non-isolated continuous bridge. But the former beam displacement is larger than the later, which indicates that the seismically-isolated continuous bridge prolongs the structure natural vibration period, but then sacrifices the beam displacement, thereby reduces the influence of the seismic motion on the bridge. Thus, in the designing of the bridge seismic isolation, the beam displacement should be attracted attention and controlled in a safe range. (a) ier 1 (b) ier 2 (c) ier 3 (d) ier 4 (e) ier 5 (f) ier 6 Fig. 12. The bending time-histories of each pier. 19

Sensors & Transducers, Vol. 175, Issue 7, July 214, pp. 12-11 It can be seen from the figures that, the pier bottom shear, pier bottom bending moment and the pier axial force of the seismically-isolated continuous bridge are much lighter than the non-isolated continuous bridge. But the former beam displacement is larger than the later, which indicates that the seismically-isolated continuous bridge prolongs the structure natural vibration period, but then sacrifices the beam displacement, thereby reduces the influence of the seismic motion on the bridge. Thus, in the designing of the bridge seismic isolation, the beam displacement should be attracted attention and controlled in a safe range. To sum up, when the lead-rubber bearing is added on the continuous girder bridge, it becomes a part of the bridge, and then participates in the balance of total energy, that is a relatively economic and effective method of seismic isolation. 5. Conclusions This article, in the natural vibration period and frequency, seismic response on bridge structure and other aspects, indicates that the lead-rubber bearing can effectively prolong the natural vibration period of Hong Kong-Zhuhai-Macau bridge, reduce the seismic response of Hong Kong-Zhuhai-Macau bridge, and consume the energy input by earthquake, to ensure most of the structure in the stage of elasticity, so as to achieve the purpose of protecting the bridge. Acknowledgements The work described in this paper was supported by grants from the Fundamental Research Funds for the Central Universities of China (CHD211JC12), and the National Natural Sciences Foundation of China (No. 517838). References [1]. H. C. Tsai, J. M. Kelly, Dynamic parameter identification for nonlinear isolation systems in response spectrum analysis, Earthquake Engineering and Structural Dynamics, Vol. 18, 1989, pp. 1119-1132. [2]. J. S. Hwang, L. H. Sheng, Equivalent elastic seismic analysis of base-isolated bridges with lead-rubber bearings, Engineering Structures, Vol. 16, Issue 3, 1994, pp. 21-29. [3]. J. S. Hwang, J. M. Chiou, An equivalent linear model of lead-rubber seismic isolation bearings, Engineering Structures, Vol. 18, Issue 7, 1996, pp. 528-536. [4]. J. S. Hwang, K. C. Chang, M. H. Tsai, Composite damping ratio of seismically isolated regular bridges, Engineering Structures, Vol. 19, Issue 1, 1997, pp. 55-62. [5]. D. H. Turkington, A. J. Carr, N. Cooke,. J. Moss, Design method for bridges on lead rubber bearings, ASCE Journal of Structural Engineering, Vol. 115, Issue SE12, 1989, pp. 31-333. [6]. J. C. Ramallo, E. A. Johnson, B. F. Spencer, Smart base isolation systems, Journal of Engineering Mechanics, Vol. 128, Issue 1, 22, pp. 188-199. [7]. J. S. Hwang, L. H. Sheng, Effective stiffness and equivalent damping of base-isolated bridges, ASCE Journal of Structural Engineering, Vol. 119, Issue 1, 1993, pp. 394-311. [8]. M. T. A. Chaudhary, A. Masato, Y. Fujino, erformance evaluation of base-isolated Yama-age bridge with high damping rubber bearings using recorded seismic data, Engineering Structures, Vol. 23, 21, pp. 92-91. [9]. R. S. Jangid, Seismic Response of Isolated Bridges, Journal of Bride Engineering, Vol. 9, Issue 2, 24, pp. 156-166. [1]. L. C. Fan, Z. Q. Wang, Resist earthquake isolated design of large-span bridges, eople s Communications ress, Beijing, 21. [11]. F. L. Zhou, Q. L. Xian, X. Y. Gao, Research on the design and experiment of the first building with rubber blanket in China, in roceedings of the Third Meeting on Structural Anti-Seismic Control, Xiamen, China, December 1995. [12]. F. L. Zhou, Engineering structural anti-seismic control, Seismological ress, Beijing, 1997. [13]. B. D. Liu, Engineering vibration and stability, Tsinghua University ress, Beijing, 25. 214 Copyright, International Frequency Sensor Association (IFSA) ublishing, S. L. All rights reserved. (http://www.sensorsportal.com) 11