ctbuh.org/papers Optimal Combination between Concrete Strength and Sets of Forms in High-rise Building Title:

Similar documents
ctbuh.org/papers Prediction and Compensation of Column Shortening for Bitexco Financial Tower Title:

ctbuh.org/papers Reform Measures of Korea s High-rise Buildings Construction Period Title: Ki-In Kim, Senior Manager, HanmiParsons Co., Ltd.

A Study on the Effective Lateral Drift Control of Super-tall Buildings in Korea

ctbuh.org/papers A Study of Flat Plate Slab Column Connections with Shear Plate in Tall Concrete Building using Experimental and Numerical Analysis

Original Publication: International Journal of High-Rise Buildings Volume 6 Number 3

Case Study of the Core Structure Succeeding Method for Tall Building Construction

State of Practice of Performance-Based Seismic Design in Korea

Shaking Table Model Test of a HWS Tall Building

SunYoung Choi, Masters Degree Candidate, Hanyang University JaeJun Kim, Professor, Hanyang University

ANALYSIS OF CO 2 EMISSIONS DEPENDING ON THE USE OF HIGH-STRENGTH RE-BAR IN BUILDINGS

Effective Beam Width for Flat Plate Systems with Edge Beams

ctbuh.org/papers Experimental Assessment of Floor Vibration Using itech Composite Beam Title:

DEVELOPMENT OF SCHEMATIC ESTIMATION SYS- TEM THROUGH LINKING QTO WITH COST DB

midas Gen Advanced Webinar Column Shortening for High-rise Building

Structural System of North-East Asia Trade Tower in Korea

Deflection Analysis with Shoring Load Transfer Coefficient for Post-Tensioned Slab

Compression Test for Precast Encased Composite Columns with Corrugated Steel Tube

CTBUH Technical Paper

COMPOSITE BEAM COMPOSED OF STEEL AND PRECAST CONCRETE (MODULARIZED HYBRID SYSTEM). PART III: APPLICATION FOR A 19-STOREY BUILDING

Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

ctbuh.org/papers Effects of Vertical Meteorological Changes on Heating and Cooling Loads of Super Tall Buildings Title:

HanSoo Kim, Department of Architectural Engineering, Konkuk University

Structural Design for Concert Hall in IFEZ Arts Center

APPLICATION OF ULTRA-HIGH PERFORMANCE CONCRETE TO PEDESTRIAN CABLE-STAYED BRIDGES

Efficient seismic analysis of high-rise buildings considering the basements

WooHyun Kim, Masters Degree Candidate, Hanyang University Jae-bok Lim, PhD Candidate, Hanyang University JaeJun Kim, Professor, Hanyang University

ctbuh.org/papers Evaluation of Progressive Collapse Resisting Capacity of Tall Buildings Title:

SELECTION MODEL OF CONSTRUCTION METHOD USING PAIRWISE COMPARISON MATRIX

Analytical Study on a Longitudinal Joints of the Slab-Type Modular Bridges Sang-Yoon Lee, Jung-Mi Lee, Hyeong-Yeol Kim, Jae-Joon Song

Lap Splices in Tension Between Headed Reinforcing Bars And Hooked Reinforcing Bars of Reinforced Concrete Beam

VARIOUS TYPES OF SLABS

Park, Jin Seon EDUCATION RESEARCH INTEREST / PROFESSIONAL PROFILE

Field Load Testing of the First Vehicular Timber Bridge in Korea

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

OPTIMAL SEISMIC DESIGN METHOD TO INDUCE THE BEAM-HINGING MECHANISM IN REINFORCED CONCRETE FRAMES

Original Publication: International Journal of High-Rise Buildings Volume 2 Number 1

Design of Double Composite Bridges using High Strength Steel

Improvements of FE Models for Predicting Natural Frequencies of Building Structures Based Upon Field Measurement Data

Properties of Tensile Strength of Non-Cement Concrete using GGBS binder activated by Sodium Silicate

42#Story)Dewi.#Chestnut) Apartments)Re#imagined:) The)SOM)Timber)Tower) Research)Project)

Should be a Corporate Member of the Institution in the field of Civil Engineering and should register as a structural engineer of the IESL.

Title. Author(s)KIM, D. W.; SHIM, C. S. Issue Date Doc URL. Type. Note. File Information

Outrigger Systems for Structural Design of Complex-Shaped Tall Buildings

Development of an Exportable Modular Building System by Integrating Quality Function Deployment and TRIZ Method

Seismic Assessment of Non-Seismically Designed Reinforced Concrete Frames with Core Walls

Applying Screenings in Lean Concrete Base & Cement Treated Base Pavement

Algorithms for Reducing the Waste Rate of Reinforcement Bars

Shear Behavior of R/C Beams with Web Openings Reinforced by Prestress Force

THE DESIGN OF LONG CANTILEVER BEAM USING POST-TENSIONED TENDONS IN KUMJUNG STADIUM

midas Gen Advanced Webinar on Construction Stage Analysis with Special Emphasis on Column Shortening

Global Village Rochester Institute of Technology Rochester, New York

TIME REDUCTION EFFECT OF THE ENHANCED TACT METHOD FOR HIGH-RISE RESIDENTIAL BUILDINGS

Construction Management Study

Predicting Axial Shortening of Vertical Elements in High Rise Buildings by Using PCA Method

RESEARCH ON THE IMPROVEMENT OF EARLY STRENGTH DEVELOPMENT FOR ORDINARY PORTLAND CEMENT

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Seismic Model Test of a Hybrid High-rise Building in Shanghai

Management Processes for Tower Crane Selection and Support Design

Effect of Loading and Beam Sizes on the Structural Behaviors of Reinforced Concrete Beams Under and After Fire

Development of Composite Beam for Productivity

E/V Shaft Cooling Method as a Stack Effect Countermeasure in Tall Buildings

UNIFIED GEOMETRY BREAKDOWN STRUCTURE (GBS) FOR BIM: VARIABLES FOR THEORY AND IMPLEMENTATION

NONDESTRUCTIVE EVALUATION BY ANALYSIS FOR DENSITY OF CRACK IN TUNNEL & UNDERGROUND STRUCTURES WITH TUNNEL SCANNER

ctbuh.org/papers The Evaluation of Performance for the Application of a Heat Recovery Ventilator to High-rise Apartments Title:

Council on Tall Buildings. and Urban Habitat CAYAN TOWER CTBUH BEST TALL BUILDING MIDDLE EAST & AFRICA

Damping Coefficients for Weak and Moderate Earthquake Ground Motions

Effects of opening in shear walls of 30- storey building

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

ENHANCING IMPACT RESISTANCE OF CONCRETE SLABS STRENGTHENED WITH FRPS AND STEEL FIBERS

Effects of Neighboring Building on Wind Loads

Automatic Rebar Estimation Algorithms for Integrated Project Delivery

PRODUCTIVITY ANALYSIS OF THE TABLE FORMWORK METHOD FOR MAKING A COST-EFFICIENT EQUIPMENT INPUT PLAN

SIMULATION METHOD OF CONSTRUCTION HOIST OPERATING PLAN FOR HIGH RISE BUILDINGS CONSIDERING LIFTING HEIGHTS AND LOADS

The Influence of the Shape of Slab on Heavyweight Impact Sound Reduction for an Apartment Building

DEFLECTION OF STRAIGHT AND CAMBERED BEAMS MEASURED DURING FOURTEEN HOURS PER DAY

DESIGN OF PC BEAM-COLUMN JOINT APPLIED X-BRACED BARS IN THE SEGMENTED STRUCTURAL SYSTEM

New Eco-friendly Two-way Void Slab

CTBUH Technical Paper

Performance of Multi-story RCC structure with Floating Column

Seismic Performance of Residential Buildings with Staggered Walls

Residual strength of Y-type perfobond rib shear connectors to cyclic load on highway bridge

Post-Earthquake Damage Evaluation for R/C Buildings

DEVELOPMENT OF BIM STANDARD DATABASE SYSTEM FOR THE REMODELING OF DETERIORATED APARTMENT

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

Development of an Efficient Tapered Slip-Form System Applying BIM Technology

Lecture 13 CONCRETE WORKS

Experimental Study on the Behavior of Bolted Joints for UHPC Panels

DEVELOPMENT OF AUTOMATED CURING SYSTEM FOR MASS CONCRETE. *Ju-hyung Ha, Youn-su Jung and Yun-gu Cho

Installing DELTABEAM. Installation of DELTABEAM. Deliveries. Storage on-site

Structural Performance Assessment and Control of Super Tall Buildings During Construction

Comparison of Shear Values of Concrete Beams by Different Codes and Equations for Various Shear Span to Depth Ratios

Tall Building Design Innovations in Australia

NATIONAL HARBOR BUILDING M

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

CTBUH Technical Paper

Erie on the Park. Timothy Moore Penn State University Architectural Engineering Structural Emphasis Advisor: Prof. Ali Memari

Crossroads at Westfields Building II

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Axial shortening in an 80-storey concrete building

Transcription:

ctbuh.org/papers Title: Authors: Subjects: Keywords: Optimal Combination between Concrete Strength and Sets of Forms in High-rise Building Sung-Hoon An, Ph. D Candidate, Korea University Kyung-In Kang, Professor, Korea University Gwang-Hee Kim, Ph. D Candidate, Korea University U-Yeol Park, Assistant Professor, Young-San University Economics/Financial Structural Engineering Concrete Construction Cost Durability Form Publication Date: 2004 Original Publication: Paper Type: CTBUH 2004 Seoul Conference 1. Book chapter/part chapter 2. Journal paper 3. Conference proceeding 4. Unpublished conference paper 5. Magazine article 6. Unpublished Council on Tall Buildings and Urban Habitat / Sung-Hoon An; Kyung-In Kang; Gwang-Hee Kim; U-Yeol Park

Optimal Combination between Concrete Strength and Sets of Forms in High-rise Building Sung-Hoon An 1, Kyung-In Kang 2, Gwang-Hee Kim 3, U-Yeol Park 4 1 Candidate of Ph.D, Architectural Engineering, Korea University 2 Professor, Architectural Engineering, Korea University 3 Ph.D, Architectural Engineering, Korea University 4 Assistant Professor, Architectural Engineering, Young-San University Abstract Recently, construction of high-rise buildings is increasing in cities to maximize land usage in Seoul Korea. Since the structural framework in high-rise buildings requires the longest duration and the greatest cost among all component work, accelerating the schedule and reducing construction cost are important factors in structural framework. In addition, improving the durability of buildings is also an important factor because their durability influences their longevity. In Korea, for schedule acceleration, the cycle time of the structure work may be shortened by the following two methods: (1) forms are stripped early without damage, such as cracking the concrete or increasing the deflection of slabs or girders, by using higher strength concrete than the designed one and (2) the number of form sets is increased. Although using higher strength concrete and increasing the number of form sets increase direct construction costs, overall cost decreases because the cycle time of structural framework is shortened. Therefore, this study presented an optimal combination between concrete strength and slab form sets to reduce the cycle time of the structural framework, to minimize overall construction costs, and to improve the durability of high-rise building. The results of these case studies were that using 2 form sets and 35MPa concrete strength is efficient considering the duration, cost, and durability. Keywords: high-rise building, formwork, cost, duration, durability 1. Introduction Recently, high-rise building construction is booming in Korea and Korean clients increase interest in such buildings because high-rise buildings make it possible to maximize land usage (Shin, 2001). Since structural framework in high-rise buildings constitutes the longest duration and incurs the greatest cost among all other component work, accelerating the schedule and reducing construction cost are important factors in structural framework (Shin, 2002). In addition, improving the durability of buildings is also an important factor because their durability influences their longevity. However, satisfying all three factors is difficult in structural framework because they often conflict. Therefore, the tradeoff between duration and construction cost is necessary to complete a structural frame economically. Accelerating the schedule is more important than reducing construction cost in Korea because construction duration of high-rise buildings has to be limited by the needs of the housing market. For accelerating the schedule, the cycle time of the Contact Author: Sung-Hoon An, Candidate of Ph.D, Dept. of Architectural Engineering, Korea University, 5Ga, Anam-Dong, Sungbuk-Gu, Seoul, 136-701 Korea Tel: 82-2-921-5920 Fax: 82-2-923-4229 e-mail: shan72@korea.ac.kr structure framework is shortened by the following two methods in Korea: (1) forms are stripped early without damage such as cracking the concrete or increasing the deflection of slabs or girders by using higher strength concrete than the designed one and (2) the number of form sets is increased. These reasons are as follows: (1) the method using higher strength concrete than the designed one to slab make it possible to reduce the curing time to allow for a 28-day design strength; and (2) the method increasing the number of slab form sets allows an earlier starting time of the upper floor's formwork in a typical floor. Although using higher strength concrete and increasing the number of slab form sets increase direct construction costs, the overall cost decreases because the shortened cycle time of the structural framework decreases the indirect costs. In addition, the durability of buildings is improved. The object of this paper is to present an optimal combination between concrete strength and sets of slab forms to reduce the cycle time of structural framework and minimize overall construction cost in high-rise building structural frame construction and improve the durability of high-rise building. The next section briefly describes the factors, which influence the cycle time of structural frameworks. In section 3, durability, which influences the longevity of high-rise 354 CTBUH 2004 October 10~13, Seoul, Korea

buildings, is considered by a study of previous research. Section 4 describes the variation of combination between concrete strength and sets of slab forms. In section 5, a case study is performed to verify the validity of the optimal combination, comparing the duration and cost with those of the initial combination and other alternative combinations. 2. Investigating durability of the slab concrete by using high strength concrete Many researchers in Korea have concluded that the structural integrity derived from using upper level strength of concrete and shortening the stripping time is not significantly different from using the original design strength and maintaining the stripping time. Oh et al. (2002) investigated the durability and allowede time of upper floor work when using the upper strength of concrete (35MPa) instead of using the design strength of concrete (24MPa) when shortening the stripping time of form. As a result, although deflection is higher than established cases, structural safety is satisfied because this deflection is lower than the allowed deflection. The resulting shortened time of upper floor work is satisfactory as well. Kim et al. (2004) investigated the durability of concrete slabs from analytical modeling and mock-up test based on Oh's research. As a result, maximum deflection of the middle of the slab and moment are smaller than the allowed deflection and moment, leading to the conclusion that there are no problems about structural integrity. This study aims to maintain high-rise building structural integrity and durability while reducing the duration of high-rise building construction by increasing the number of forms and applying upper strength concrete beyond the design strength of the slab in the framework. 3. Element concerned with Framework's duration The framework of high-rise buildings has more typical floors than other low/middle-rise buildings because the numbers of floors are numerous (Ferguson, 1999). Therefore, the cycle time circulating all frameworks through one floor could be an absolute factor to control the total duration of the project (Kim and Kang, 2003). The cycle time concerned the schedule for constructing the column/wall and slab formwork, placing the column/wall and slab reinforcing bar, installing electrical and plumbing components, pouring of concrete, and the stripping time of form etc. Of these components, this study focuses on the stripping time of form. The others are assumed to be fixed. (1) Form stripping time The stripping time of form affects the schedule and cost of the structural framework because the stripping time influences the cycle time for a typical floor of a high-rise building. Therefore, considering the number of slab form sets, which are determined previously, the cycle time of a typical floor is determined according to the stripping time. The standard for stripping form and support is regulated by the Concrete Standard Specification in Korea (Table 1) (Korea Concrete Institute, 2003). Table 1. Allowed concrete strength for stripping form (MPa) Type Side wall of expanded base, side of beam, column, wall etc. Underside of slab, beam, and arch Concrete strength (f cu) over 5Mpa design strength 2/3 (f cu 2/3f ck), over 14MPa In a case in the United States, the structural frame of a typical floor of a 70-story building was constructed in two days by using a pre-shoring support system (Yoon and Hong, 2000), and the total duration of this building was 24 months. This study does not consider the pre-shoring and re-shoring support system because there are no clear rules for these systems in Korea. (2) Increasing the number of slab form sets Increasing the number of slab form sets that shortens the cycle time for typical floor without decreasing the stripping time is considered. When one set of slab form is used, the upper slab form could be fabricated only after stripping the slab form. However, using several slab form sets makes it possible to work simultaneously on the upper floors without stripping the slab form of lower floors. (3) Predicting the early strength of concrete This study supposes that design strength of slab concrete is 24MPa and 27MPa because most of the high-rise buildings in Korea have adopted 24MPa and 27MPa as the design strength of slab concrete. Many methods of predicting the early strength of concrete exist depending on the condition. This study proposed that equation (1), which was suggested by ACI 209 committee (Kumar, 1993), predicts the strength of concrete, which pouring the slab, based on 28 days strength. f t 4 + 0.85t cm = fc 28 (1) In equation (1), f cm is the compressed strength of concrete over t days, f c28 is the strength of concrete over 28 days, and t is the curing period. In addition, equation (1) assumes that concrete curing temperature is 23 ±1.5 and a standard Portland cement is used. CTBUH 2004 October 10~13, Seoul, Korea 355

curing period (day) 30 25 20 15 10 5 curing time for 100% allowed 28-days strength of the 24MPa curing time for 100% allowed 28-days strength of the 27MPa Table 2. Cycle time of typical floor according to using the upper concrete strength and the number of form sets Number of form sets Concrete strength 1set 2set 3set 4set Design Application 24MPa 24MPa 8.0 4.0 3.0 2.0 27MPa 7.0 4.0 2.0 2.0 30MPa 6.0 3.0 2.0 2.0 35MPa 5.0 3.0 2.0 2.0 40MPa 4.0 2.0 2.0 2.0 27MPa 8.0 4.0 3.0 2.0 0 24 27 30 35 40 strength of concrete (MPa) Fig. 1. Reducing the time for 100% allowed strength according to concrete strength When using the 27MPa, 30MPa, 35MPa, and 40MPa concrete strength on the slab instead of the 24MPa and 27MPa design strength, the curing time for 100% allowed 28days' strength of the 24MPa and 27MPa is presented in Fig.1. by using equation (1). 4. Variations according to the strength of concrete and the number of form sets (1) Combination of upper concrete strength and the number of form sets Using the upper strength of concrete and increasing the number of form set are useful methods to shorten the cycle time of a typical floor, so that combining the two methods simultaneously in typical floor construction is possible for shortening the duration. Table 2 shows variations in the cycle time of a typical floor when using upper concrete strength and more form sets than designed. In these variations, the cycle time is calculated by focusing on the form stripping time; other elements related to the duration of the structural framework are consistent. (2) Costs related to using upper concrete strength and increasing the number of form sets Increasing the number of slab form sets means the increasing the quantity of slab forms and supporters. In addition, using upper concrete strength causes on increase in the material cost of slab concrete work, which directly relates to the structural framework cost. Nevertheless, it could shorten the duration of the structural framework, leading to a reduction in equipment cost such as tower crane, concrete placing boom and concrete pump, and indirect cost. For these reasons, comparisons between the increasing direct costs and decreasing indirect costs are considered. 27MPa 30MPa 7.0 4.0 2.0 2.0 35MPa 6.0 3.0 2.0 2.0 40MPa 5.0 3.0 2.0 2.0 5. Case study (1) Case-1 The first case study building of this study is located in Yeongdeungpo-gu, a part of Seoul in Korea, and this building has 34 above-ground floors and 6 basement floors (Table 3). All slab concrete, from the 7 th to the 34 th floors, is designed with 27MPa concrete strength. The building's structural framework was processed with 5-day cycling and two sets of slab form. As mentioned in the previous section, though the cycle time of the structural framework is 4-day with two sets of slab form and 27MPa strength concrete when focused on the stripping time of slab forms, this case-1 processed 5-day for the cycle time of the structural frame considering the project's condition. Table 3. Major features of case-1 Classification Project name Location Usage Duration Structure Design Parameter Major subject building project Yeongdeungpo-Gu, Seoul, Korea Commercial and Residential building 2000.07~2003.07. (37 months) Area of site Gross floor area Number of floors Reinforcing concrete structure 4,602 m2 68,143 m2 34 above ground 6 below ground Table 4 hypothesizes construction cost, duration and typical floor cycle after considering the increased number of form sets, increased high strength concrete costs, decreased equipment cost, and reduced indirect cost. 356 CTBUH 2004 October 10~13, Seoul, Korea

Table 4. Construction cost when using upper concrete strength and number of form sets in the case -1 Concrete Number of form set 1set 2set 3set strength Items 27MPa 30MPa 35MPa 40MPa Cost (million won) 2428 2309 2636 10 6 5 Cycle time of a typical floor (day) 8 5 4 Cost (million won) 2452 2185 2512 10 5 4 Cycle time of a typical floor (day) 8 4 3 Cost (million won) 2305 2187 2513 9 5 5 Cycle time of a typical floor (day) 7 4 3 Cost (million won) 2417 2249 2624 9 4 4 Cycle time of a typical floor (day) 7 3 3 (2) Case-2 The second case study building of this study is located in Mapo-gu, a part of Seoul in Korea, and this building has 37 above-ground floors and 6 basement floors (Table 5). All slab concrete, from the 7 th to the 37 th floors, is designed with 27MPa concrete strength. The building's structural framework was processed with 4-day cycling and two sets of slab form as mentioned in the previous section. Table 5. Major features of case-2 Classification Project name Location Usage Duration Structure Design Parameter Major subject building project Mapo-Gu, Seoul, Korea Commercial and Residential building 2001.12~2004.10. (35 months) Area of site Gross floor area Number of floors Reinforcing concrete structure 9,526 m2 120,544 m2 37 above ground 6 below ground Table 6 hypothesizes construction cost, duration and typical floor cycle after considering the increased number of form sets, increased high strength concrete costs, decreased equipment cost, and reduced indirect cost. Table 6. Construction cost when using upper concrete strength and number of form sets in the case -2 Concrete Number of form set 1set 2set 3set strength Items 27MPa 30MPa 35MPa 40MPa Cost (million won) 2815 2415 2677 10 5 4 Cycle time of a typical floor (day) 8 4 3 Cost (million won) 2692 2460 2554 9 5 3 Cycle time of a typical floor (day) 7 4 2 Cost (million won) 2368 2299 2556 7 4 3 Cycle time of a typical floor (day) 6 3 2 Cost (million won) 2386 2317 2737 6 4 3 Cycle time of a typical floor (day) 5 3 2 6. Discussion All of these case studies actually applied 2 form sets and design concrete strength (27MPa). However, in these case studies, the lowest cost was acquired when using 2 form sets and 30MPa, 35MPa concrete strength, respectively. We are convinced that using 2 form sets is better than using 1 or over 3 form sets in Korea. When using 1 form set, the cycle time is too long to increase the duration of framework because of the stripping time of form. When using over 3 form sets, overall construction costs are increased because the increasing the material cost of forms. In addition, we are convinced that using 35MPa strength is efficient with 2 form sets. Although a minimum overall cost of case-1 is when using 2 form sets and 30MPa concrete strength, the difference between overall cost using 2 form sets and 30MPa concrete strength and 2 form sets and 35MPa concrete strength is inconsiderable. This reason is the advantage of increasing durability when using the 35MPa concrete strength. 7. Conclusion This study presented an optimal combination between concrete strength and slab form sets to reduce the cycle time of the structural framework, to minimize overall construction costs, and to improve the durability of high-rise building. Case studies were performed to verify the validity of the optimal combination, comparing duration and cost with those of the initial combination and other alternative combinations. The results of these case studies were that using 2 form sets and 35MPa concrete strength is efficient considering the duration, cost, and durability. CTBUH 2004 October 10~13, Seoul, Korea 357

Acknowledgement This research (03R&D C04-01) was financially supported by the Ministry of Construction & Transportation of South Korea and Korea Institute of Construction and Transportation Technology Evaluation and Planning, and the authors are grateful to the authorities for their support. References 1) Ferguson, S.A. (1999) High-rise formwork for the 21st century, International Formwork System Seminar for High Rise Construction, AIK. 2) Hegazy, T. (2001) Computer-Based Construction Project Management, Prentice Hall 3) Hutchinson, N. (1999) CM consideration in high rise form -work selection, International Formwork System Seminar for High Rise Construction, AIK. 4) Kim, C. Oh, S.J. Yoo, S.H. Lee, K.S. and Shin, S.W. (2004) An study on the economic evaluation of reinforced concrete structure according to reduction of form setting period, Proceeding of Journal of the AIK, 24(1) 5) Kim, G.H. and Kang, K.I. (2003) A study on development and application of th e unit table form for concrete structural frame work of high-rise buildings. Journal of the AIK structure & construction section, 19(8) 6) Korea Concrete Institute (2003) Concrete Standard Specification in Korea, Seoul: Kimoondang 7) Kumar, P.M. and Paulo, J.M.M. (1993) Concrete-structure, properties and Materials, Prentice 8) Oh, S.J. Yoo, S.H. Shin, S.W. Lee, B.H. and Jee, S.W. (2003) A study of the Setting Period of Forms according to Concrete Strength, Proceedings of Academic Conference of the AIK structure & construction section, 22(2) 9) Shim, G.B. (2001) Schemes for Attracting and Training the Construction Craft Workers, Construction and Economy Research Institute of Korea 10) Shin, S.W. (2001) High Strength-high Performance Concrete Usage for Super tall Residential Building, Review of Architecture and Building Science, Architectural Institute of Korea, 45(10) 11) Shin, S.W. (2002) It's time to building for Korean style super tall building, Review of Architecture and Building Science, Architectural Institute of Korea, 46(8) 12) Yoon, K.S. and Hong, W.K. (2000) New Construction Cycle for Highrise Buildings by Standardization of Design of Slab-Formwork, Journal of the AIK structure & construction section, 16(6) 358 CTBUH 2004 October 10~13, Seoul, Korea