DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: STO CORPORATION

Similar documents
ESR-2771 Reissued December 1, 2013 This report is subject to renewal December 1, 2014.

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT APPLIED FINISH SYSTEMS REPORT HOLDER: BASF CORPORATION WALL SYSTEMS

ICC-ES Evaluation Report Reissued April 1, 2010 This report is subject to re-examination in two years.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: BASF CORPORATION WALL SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: MATERIAL DISTRIBUTOR COMPANY, INC.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: AMERICAN EAGLE MATERIALS, LLC

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: AVM INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

Code Compliance Research Report CCRR-0231

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC. EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: BONSAL AMERICAN, INC.

STRENGTH AND DURABILITY OF THE INSTALLED STONE

ESR-1064 Reissued August 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC.

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: WESTCOAT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: PLY GEM SIDING GROUP EVALUATION SUBJECT:

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

(800) (562) A Subsidiary of the International Code Council

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: SUPERFORM PRODUCTS LTD. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: INTEPLAST GROUP CORPORATION EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

Transcription:

0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1030 Reissued 12/2016 This report is subject to renewal 12/2017. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: STO CORPORATION 3800 CAMP CREEK PARKWAY BUILDING 1400, SUITE 120 ATLANTA, GEORGIA 30331 EVALUATION SUBJECT: STO RAINSCREEN AND STO RAINSCREEN II CLASS PB EXTERIOR INSULATION AND FINISH SYSTEMS WITH DRAINAGE Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1030 Reissued December 2016 This report is subject to renewal December 2017. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 24 00 Exterior Insulation and Finish Systems REPORT HOLDER: STO CORPORATION 3800 CAMP CREEK PARKWAY BUILDING 1400, SUITE 120 ATLANTA, GEORGIA 30331 (404) 346-3666 www.stocorp.com tviness@stocorp.com EVALUATION SUBJECT: STO RAINSCREEN AND STO RAINSCREEN II CLASS PB EXTERIOR INSULATION AND FINISH SYSTEMS WITH DRAINAGE 1.0 EVALUATION SCOPE Compliance with the following codes: 2006 International Building Code (IBC) 2006 International Residential Code (IRC) Properties evaluated: Fire-resistance-rated construction Noncombustible construction Structural transverse wind load resistance Surface-burning characteristics Weather resistance Ignition resistance 2.0 USES The Sto RainScreen and RainScreen II Class PB Exterior Insulation and Finish Systems with Drainage are used as insulation and exterior wall finishes on the types of construction noted in this report. 3.0 DESCRIPTION 3.1 Sto RainScreen Class PB Exterior Insulation and Finish Systems with Drainage: 3.1.1 General: The Sto RainScreen Class PB Exterior Insulation and Finish System with Drainage is an adhered composite drainage EIFS clad wall assembly applied to vertical wood-framed exterior walls covered with unpainted wood structural panels, water-resistant core gypsum sheathing, or Dens-Glass Gold sheathing; and to steelframed exterior walls covered with unpainted wood structural panels, water-resistant core gypsum sheathing, or Dens-Glass Gold sheathing. System components consist of a water-resistive barrier, grooved expanded polystyrene (EPS) drainage insulation boards, mechanical fasteners, a base coat, woven fiberglass fabric, a synthetic plaster finish coat, accessories and sealants. See Figure 1 for an illustration of product components. The Sto RainScreen Class PB Exterior Insulation and Finish System with Drainage may be used on (1) buildings of any type of construction under the IBC, including but not limited to, buildings classified as having a Group R-1, R-2, or R-4 Occupancy Group; (2) buildings constructed under the IRC; and (3) in noncombustible construction as described in Section 4.4. 3.1.2 Materials: 3.1.2.1 Substrates: 3.1.2.1.1 Wood Structural Panel Sheathing: Exterior or Exposure 1 grade plywood complying with U.S. DOC PS-1 or PS-2 (UBC Standard 23-2 or 23-3); or Exposure 1 grade oriented strand board (OSB) complying with U.S. DOC PS-2 (UBC Standard 23-3); and with a minimum thickness of 7 / 16 inch (11.1 mm). 3.1.2.1.2 Gypsum Sheathing: Minimum 5 / 8 -inch-thick (15.9 mm), water-resistant core gypsum sheathing complying with ASTM C 79, or 1 / 2 - or 5 / 8 -inch-thick (12.7 or 15.9 mm) Dens-Glass Gold, a proprietary water-resistant core gypsum sheathing manufactured by GP Gypsum Corporation and recognized in ICC-ES evaluation report ESR-3087. 3.1.2.1.3 Water-resistive Barrier: A water-resistive barrier in accordance with IBC Section 1404.2 or IRC Section R703.2 must be placed over all substrates and behind the insulation board. Application of the barrier must comply with the applicable code. When applied over any wood-based sheathing, the barrier must be a minimum of two layers of Grade D building paper, or one layer of 60-minute Grade D building paper, as required by IBC Section 2510.6 or IRC Section R703.6.3. 3.1.2.1.4 Drainage Insulation Boards: The drainage insulation boards must be EPS rigid insulation boards with grooves on the back side for drainage. The grooves must run the full width of the board, and be 1 inch wide (25.4 mm) by 1 / 4 inch deep (6.4 mm), spaced 1 3 / 4 inches ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2015 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 12 1000

ESR-1030 Most Widely Accepted and Trusted Page 2 of 12 (44 mm) on center. The boards must have a nominal density of 1 pound per cubic foot (16 kg/m 3 ), and a maximum flame-spread index not greater than 25 and a smoke-developed index not greater than 450 when tested in accordance with ASTM E 84 (UBC Standard 8-1). The boards must comply with ASTM C 578 as Type I and have a maximum width of 24 inches (610 mm), a maximum length of 48 inches (1219 mm), and thicknesses ranging from 1 1 / 2 to 4 inches (38 to 102 mm). 3.1.2.1.5 Mechanical fasteners: The following Windlock fastening systems must be used for the insulation boards: 1. Wind-Devil, consisting of a 1 3 / 4 -inch-diameter (44 mm) W-WDP plastic plate and a minimum UWLM- 2 fastener [No. 7 by 2-inch-long (51 mm) corrosionresistant buglehead screw], must be used to attach insulation boards through wood-based or gypsum sheathing into wood studs. See Figure 2 for fastener selection based on insulation board thickness. 2. Wind-Devil 2, consisting of a 2-inch-diameter (51 mm) WD-2W plastic plate and a minimum UST-3 fastener [2 5 / 8 -inch-long (67 mm) corrosion-resistant buglehead screw], must be used to attach insulation boards through wood-based or gypsum sheathing into steel studs. See Figure 2 for fastener selection based on insulation board thickness. 3.1.2.1.6 Base Coat: Sto BTS-Plus is a one-component, polymer-modified, cement-based material and is packaged in 60-pound (27.3 kg) bags. The material is field-mixed with 7 to 9 quarts (6.6 to 8.5 L) of potable water per bag. Sto BTS-Plus has a one-year shelf life when stored at temperatures between 38 F and 90 F (3.3 C and 32.2 C) and off the ground, in a dry area, protected from moisture. 3.1.2.1.7 Reinforcing Fabric: Sto Mesh is a reinforcing fabric having interlaced glass fiber made from twisted multi-end strands, which has been treated for alkali resistance and compatibility with the other Sto components. The fabric is available in 36-inch-wide (965 mm), 475-square-foot (44 m 2 ) rolls, and weighs approximately 4.5 ounces per square yard (153 g/m 2 ) with a 6-by-5 thread count per inch-width (per 25.4 millimeterwidth). Minimum tensile strength in the weft and warp directions is 165 and 150 pounds per lineal inch (28.9 and 26.2 N/mm), respectively. When protected from moisture, Sto Mesh has a one-year shelf life. 3.1.2.1.8 Finish Coat: StoLit finish coat is a premixed, acrylic-based, textured wall finish coating of hardened air-cured material made with marble particles of a graded size. StoSilco Lit is a premixed, silicone-enhanced textured wall finish coating with graded marble aggregates. Both coatings are packaged in 70-pound (31.5 kg) pails and have a one-year shelf life when stored at temperatures between 38 F and 90 F (3.3 C and 32.2 C). 3.1.2.1.9 Accessories: Starter tracks, corner beads, drip edges, trim accessories and weep screeds used with the system are polyvinyl chloride (PVC) materials conforming to ASTM D 1784, and approved by Sto Corporation. The weep screed is Starter Track, Part No. STDE, manufactured by Plastic Components, Inc. 3.1.2.1.10 Sealants: The sealants must be compatible with the EIFS components and recommended by Sto Corporation. Evidence must be submitted to the code official showing that the manufacturer-recommended sealant complies with ASTM C 920, Type M, Grade NS, Class 25. The sealants must have a movement capability of ±25 per cent or greater, and must be tested in accordance with ASTM C 1382. Use of sealants must be qualified for each material to which the sealants will be applied. The details for sealant installation, including the width and thickness of the sealant, must be specified by a registered design professional, designer, or builder, or by Sto Corporation, in that order, to the satisfaction of the code official. 3.2 Sto RainScreen II Class PB Exterior Insulation and Finish Systems with Drainage: 3.2.1 General: The Sto RainScreen II Class PB Exterior Insulation and Finish System with Drainage is an adhered composite drainage EIFS clad wall assembly applied to vertical wood-framed exterior walls covered with unpainted wood structural panels, water-resistant core gypsum sheathing, or Dens-Glass Gold sheathing; and to steelframed exterior walls covered with unpainted wood structural panels, water-resistant core gypsum sheathing, or Dens-Glass Gold sheathing. System components consist of a water-resistive barrier, a drainage mat, mechanical fasteners, an adhesive, EPS insulation boards, a base coat, woven fiberglass fabric, a synthetic plaster finish coat, accessories and sealants. See Figure 3 for an illustration of product components. The Sto RainScreen II Class PB Exterior Insulation and Finish System with Drainage may be used on (1) buildings of any type of construction under the IBC, including, but not limited to, buildings classified as having a Group R-1, R-2, or R-4 Occupancy Group; (2) buildings constructed under the IRC; and (3) in noncombustible construction as described in Section 4.4. 3.2.2 Materials: 3.2.2.1 Substrates: 3.2.2.1.1 Wood Structural Panel Sheathing: As described in Section 3.1.2.1.1. 3.2.2.1.2 Gypsum Sheathing: As described in Section 3.1.2.1.2. 3.2.2.1.3 Water-resistive Barrier: As described in Section 3.1.2.1.3. 3.2.2.1.4 Drainage Mat: The drainage mat used for Sto Insulation Boards must be either Ultra-Lath or galvanized, expanded metal lath. Ultra-Lath, manufactured by Plastic Components, Inc., is a UV-stabilized, heavy-duty extended polyolefin (polyethylene or polypropylene), self-furred lath. Ultra-Lath has 1 / 4 -inch-by- 1 / 4 -inch (6.4 mm by 6.4mm) square holes oriented 45 degrees to the length of the lath, and is available either as a mat measuring 27 inches wide by 96 inches long (686 mm by 2438 mm) or as a roll measuring 27 inches wide by 100 feet long (686 mm by 30 480 mm). The galvanized, expanded metal lath is a selffurred diamond mesh, weighing a minimum of 2.5 pounds per square yard (0.95 kg/m 2 ), and must comply with the applicable code. 3.2.2.1.5 Mechanical Fasteners: The following Windlock fastening systems must be used for attachment of the drainage mat: 1. The Wind-lock ULP-3W2 system is used in EIFS systems where the drainage mat is fastened to woodbased sheathing, and, where applicable, through gypsum sheathing into wood studs. The ULP-3W2 system consists of a ULP-302 plate; a 1 3 / 4 -inchdiameter (44 mm), rigid polypropylene washer; and a corrosion-resistant UW-1 or UW-2 screw. The Windlock UW-1 is a No. 6 by 1 5 / 8 -inch-long (41 mm), Type S buglehead screw. The Wind-lock UW-2 is a No. 7 by 2-inch-long (51 mm), Type S buglehead screw. See Figure 4 for fastener selection based on insulation board thickness.

ESR-1030 Most Widely Accepted and Trusted Page 3 of 12 2. The Wind-lok ULP-3S2 system is used in EIFS where the drainage mat is fastened through the gypsum sheathing to steel studs. The fastening system consists of a ULP-302 plate; a 1 3 / 4 -inch-diameter (44 mm), rigid polypropylene washer; and a corrosionresistant US-2 screw. The US-2 is a No. 6, 2-inchlong (51 mm), Type S-12 buglehead screw. See Figure 4 for fastener selection based on insulation board thickness. 3.2.2.1.6 Adhesive: Sto BTS-Plus adhesive is the same material as the base coat described in Section 3.1.2.1.6 and is used to adhere Sto Insulation Boards to the drainage mat described in Section 3.2.2.1.4. 3.2.2.1.7 Insulation Boards: The insulation boards must be expanded polystyrene (EPS) rigid insulation boards with a nominal density of 1 pound per cubic foot (16.0 kg/m 3 ), and a maximum flame-spread index not greater than 25 and a smoke-developed index not greater than 450 when tested in accordance with ASTM E 84 (UBC Standard 8-1). The boards comply with ASTM C 578 as Type I and have a maximum width of 24 inches (610 mm) and a maximum length of 48 inches (1219 mm). Thicknesses range from 1 1 / 2 to 4 inches (38 to 102 mm). 3.2.2.1.8 Base Coat: As described in Section 3.1.2.1.6. 3.2.2.1.9 Reinforcing Fabric: As described in Section 3.1.2.1.7. 3.2.2.1.10 Finish Coat: As described in Section 3.1.2.1.8. 3.2.2.1.11 Accessories: As described in Section 3.1.2.1.9. 3.2.2.1.12 Sealants: As described in Section 3.1.2.1.10. 4.0 INSTALLATION 4.1 General: Installation of the Sto RainScreen and Sto RainScreen II Class PB Exterior Insulation and Finish Systems with Drainage must comply with this report, the applicable code and the manufacturer s published installation instructions. The manufacturer s published installation instructions must be available at the jobsite at all times during installation. The system must be applied over unpainted wood-based structural panels, water-resistant core gypsum sheathing, or Dens-Glass Gold sheathing attached to minimum 2-by- 4 wood studs having a minimum specific gravity of 0.50, such as Douglas fir larch, spaced at a maximum of 16 inches (406 mm) on center, or to minimum 43-mil [0.0478-inch (1.2 mm) base-metal thickness] galvanized steel studs spaced at a maximum of 16 inches (406 mm) on center. The substrates must be limited to those having planar irregularities not exceeding 1 / 4 inch (6.4 mm), and must be structurally sound, clean, dry and smooth, with all dust and deleterious materials removed. All materials must be installed by applicators approved by Sto Corporation. During application of any water-based materials, the wall surface and the surrounding air temperature must be 40 F (4.4 C) or higher. The EIFS materials must be protected from wind, rain, dust and freezing until fully cured. If water is added to mixtures for workability, the minimum amount of water must be used. Typical installation details are shown in Figure 5. The sheathing must be installed with all edges blocked and attached to the framing members in accordance with Table 1. Expansion joints are required at locations where the substrate changes, at floor lines in wood-framed construction in which lumber shrinkage will occur, where the EIFS abuts another material, and where structural movement is anticipated. Joints must be installed as specified by the registered design professional, builder or exterior coating manufacturer, in that order. The weep screed must be attached, at the bottom of the wall system, to wood-based sheathing with galvanized or zinc-coated 6d common nails at 12 inches (305 mm) on center, or through gypsum sheathing into steel studs with minimum No. 6 by 1 1 / 4 -inch-long (32 mm), Type S-12, corrosion-resistant buglehead screws along each stud. The water-resistive barrier described in Section 3.1.2.1.3 must be installed over the sheathing and weep screed prior to installation of the insulation board. 4.2 Sto RainScreen Class PB Exterior Insulation and Finish Systems with Drainage: 4.2.1 Drainage Insulation Boards: The drainage insulation boards must be oriented with the grooves running vertically and fastened in accordance with the fastening pattern shown in Figure 2, using the designated Windlock fastening system described in Section 3.1.2.1.5. All joints are tightly butted, and vertical joints must be staggered. 4.2.2 Base Coat: Before any coatings are applied, the entire surface of the installed insulation board must be leveled with a rasping board or power rasper. A base coat of Sto BTS-Plus is applied to the entire board surface with a stainless steel trowel, to a uniform thickness of approximately 1 / 16 inch (1.6 mm). 4.2.3 Reinforcing Fabric: After the base coat is installed, Sto Mesh is immediately placed against the wet base coat and troweled from center to edge. The Sto Mesh must be continuous around corners and lapped at least 2 1 / 2 inches (64 mm) along edges. Wrinkles must be avoided and the mesh must be fully embedded and covered. The base coat must be allowed to dry for 12 hours prior to application of the finish coat. 4.2.4 Finish Coat: A sealant, as described in Section 3.1.2.1.10, must be applied, prior to application of the finish coat at system terminations, exposed joints, floor lines of wood-framed construction, changes in building shape or roof line, substrate changes, expansion joints, and wall penetrations. After the base coat has dried, the factoryprepared StoLit or StoSilco Lit plaster finish material is thoroughly mixed, using a high-speed mixer, until a uniform workable consistency is achieved. Small amounts of water are permitted to be added for workability. The StoLit or StoSilco Lit plaster finish is then applied directly to the base coat, using a clean, stainless steel trowel. The final texture is achieved with a plastic or stainless steel trowel. The finish coat thickness must not be greater than the diameter of the largest aggregate, approximately 1 / 16 inch thick (1.6 mm). 4.3 Sto RainScreen II Class PB Exterior Insulation and Finish Systems with Drainage: 4.3.1 Drainage Mat: The drainage mat described in Section 3.2.2.1.4 is installed with mechanical fasteners in accordance with Table 1 and Figure 4 over the waterresistant barrier. 4.3.2 Insulation Boards: Before the insulation boards are placed over the drainage mat, Sto BTS-Plus adhesive described in Section 3.2.2.1.5 is applied to the back of the boards, using a stainless steel or plastic trowel having 1 / 2 -inch-by- 1 / 2 -inch (12.7 mm by 12.7 mm) notches, spaced at 2 1 / 2 inches (64 mm) on center. The adhesive ribbons are applied parallel to the short dimension of the insulation boards. The insulation boards are adhered to the drainage mat and substrate, with adhesive ribbons vertically to provide a drainage cavity, and with uniform pressure over

ESR-1030 Most Widely Accepted and Trusted Page 4 of 12 the entire surface to ensure uniform contact. All joints are tightly butted, and vertical joints must be staggered. 4.3.3 Base Coat: As described in Section 4.2.2. 4.3.4 Reinforcing Fabric: As described in Section 4.2.3. 4.3.5 Finish Coat: As described in Section 4.2.4. 4.4 Types I, II, III and IV (Noncombustible) Construction: The Sto RainScreen and RainScreen II Class PB Exterior Insulation and Finish Systems with Drainage may be applied where noncombustible construction [Type I, II, III, or IV (IBC)] is required, provided the construction is as described in this section. 4.4.1 Framing: The framing is minimum 43-mil [0.0478 inch (1.2 mm)] by 3 5 / 8 -inch (92 mm) steel studs spaced a maximum of 16 inches (406 mm) on center. 4.4.2 Interior Finish: One layer of 5 / 8 -inch-thick (15.9 mm), Type X gypsum board complying with ASTM C 36, applied horizontally to the steel studs using corrosionresistant, No. 6 by 1 1 / 4 -inch-long (32 mm), Type S, buglehead drywall screws spaced 8 inches (203 mm) on center along the perimeter studs and 12 inches (305 mm) on center within the field. All horizontal gypsum board joints are to be backed. All joints must be taped and, including screw heads, must be treated with joint compound in accordance with the applicable code. At floor levels, stud cavities must be blocked with Thermafiber insulation (ICC-ES report ER-2331) having a 4 lb/ft 3 (64 kg/m 3 ) density, and being 4 inches (102 mm) thick and 2 feet (610 mm) wide. 4.4.3 Exterior Finish: One layer of 5 / 8 -inch-thick (15.9 mm), Type X, water- resistant core gypsum sheathing complying with ASTM C 79, applied horizontally to the steel studs using corrosion-resistant, No. 6 by 1 1 / 4 -inchlong (32 mm), Type S, buglehead drywall screws spaced 8 inches (203 mm) on center along the perimeter studs and 12 inches (305 mm) on center within the field. A waterresistive barrier, as described in Section 3.1.2.1.3, must be installed over the sheathing, prior to installation of the Sto RainScreen or RainScreen II system. The maximum foam plastic insulation thickness is 4 inches (102 mm). 4.5 Repair: Damaged portions of the exterior face must be cut out, and the affected area patched using the same techniques and types of materials used in the original application as described in this report. 4.6 Openings: Wall openings must be framed with minimum 43-mil, 0.0478-inch-base-metal-thickness (1.2 mm), corrosionresistant steel. 4.7 Wind Design: Allowable transverse wind pressures for the RainScreen and RainScreen II systems installed in accordance with this report are as noted in Table 1. The framing members must be designed to resist all positive and negative design loads with a maximum allowable deflection of 1 / 240 of the span. 5.0 CONDITIONS OF USE The Sto RainScreen and Sto RainScreen II Class PB Exterior Insulation and Finish Systems with Drainage described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The system must be manufactured, identified and installed in accordance with this report, the manufacturer s published installation instructions and the applicable code. In the event of a conflict between the manufacturer s published installation instructions and this report, this report governs. 5.2 The insulation board must be separated from the building interior by a thermal barrier complying with the applicable code. 5.3 Installation must be done by applicators approved by Sto Corporation. An installation card, as shown in Figure 6, must be completed at the end of each project and filed with the code official. In addition, a sealant application card, as shown in Figure 7, must be filed with the code official after sealant application. 5.4 The systems are permitted to be installed on exterior walls of any type of construction, provided that the installation is in accordance with Section 4.4. 5.5 The design wind load pressures must not exceed the capacities indicated in Table 1 for the applicable system. 5.6 The finish system must not be used as exterior stud wall bracing. Wall bracing must be provided in accordance with IBC Section 2308.9.3 and IRC Section R602.10. 5.7 In jurisdictions adopting the IBC or IRC, where the possibility of termite infestation is very heavy, the system must terminate not less than 6 inches (152 mm) above the finish ground level, in accordance with IBC Section 2603.8 or IRC Section R320.5. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for EIFS Clad Drainage Wall Assemblies (AC235), dated October 2004 (editorially revised December 2007 and April 2008). 7.0 IDENTIFICATION Containers of base coat, reinforcing mesh, and finish coat of the Sto RainScreen and Sto RainScreen II Class PB Exterior Insulation and Finish Systems with Drainage described in this report must bear a label noting the manufacturer s name (Sto Corp.) and address; product name; evaluation report number (ESR-1030); production date; batch number; quantity of material; storage, mixing and curing instructions; and expiration date. The Windlock fasteners are packaged in cartons bearing the Windlock name; the designation Wind-Devil, Wind- Devil 2, ULP-3W2 or ULP-3S2; the quantity; and the installation instructions. The weep screeds are packaged in cartons bearing the Plastic Components name and the part number (STDE). Foam plastic insulation boards must be identified in accordance with their respective evaluation reports. When used on walls required to be of noncombustible construction, the EPS foam plastic boards must be identified along the edge of each board, and on both board faces of at least one board from each packaged bundle, with the following information: The Sto Corp. name and the evaluation report number (ESR-1030). The name and evaluation report number of the insulation board molder. The name of the inspection agency, as indicated in the evaluation report for the foam plastic.

ESR-1030 Most Widely Accepted and Trusted Page 5 of 12 TABLE 1 STO RAINSCREEN AND STO RAINSCREEN II ASSEMBLIES AND DESIGN WIND PRESSURES ASSEMBLY/ DESIGN WIND PRESSURE 1 (RainScreen II)/ Positive: 35 psf Negative: 30 psf 2 (RainScreen II)/ Positive: 35 psf Negative: 30 psf 3 (RainScreen II)/ Positive: 65 psf Negative: 55 psf 4 (RainScreen II)/ Positive: 35 psf Negative: 30 psf 5 (RainScreen)/ Positive: 35 psf Negative: 30 psf 6 (RainScreen)/ Positive: 65 psf Negative: 55 psf FRAMING SHEATHING SHEATHING ATTACHMENT Min. 2-by-4 wood studs at max. 16 inches o.c. Min. 18 gage steel studs at max. 16 inches o.c. Min. 18 gage steel studs at max. 16 inches o.c. Min. 2-by-4 wood studs at max. 16 inches o.c. Min. 2-by-4 wood studs at max. 16 inches o.c. Min. 18 gage steel studs at max. 16 inches o.c. Min. 7 / 16 -inch-thick OSB or plywood Min. 7 / 16 -inch-thick OSB or plywood Min. 5 / 8 - inch-thick gypsum sheathing Min. 5 / 8 - inch-thick gypsum sheathing Min. 7 / 16 -inch-thick OSB or plywood Min. 5 / 8 - inch-thick gypsum sheathing or 1 / 2 - or 5 / 8 -inchthick Dens-Glass Gold gypsum sheathing For SI: 1 inch = 25 mm, 1 psf = 47.88 Pa, 1 pound = 0.454 kg. Min. 6d common nails at 6 inches o.c. along perimeter and 12 inches o.c. within the field Wind-lock US-2 screws at 6 inches o.c. along perimeter, 12 inches o.c. within the field Min. No. 6 by 1 1 / 4 - inch-long Type S-12 buglehead screws spaced 8 inches o.c. along studs Wind-lock UW-1 screws spaced 8 inches o.c. along studs Min. 6d common nails at 6 inches o.c. along perimeter and 12 inches o.c. within the field Min. No. 6 by 1 1 / 4 - inch-long Type S-12 buglehead screws spaced 8 inches o.c. along studs DRAINAGE MAT Ultra Lath or min. 2.5-pound-persquare-yard selffurred diamond mesh metal lath Ultra Lath or min. 2.5-pound-persquare-yard selffurred diamond mesh metal lath Min. 2.5-pound-persquare-yard self furred diamond mesh metal lath Min. 2.5-pound-persquare-yard selffurred diamond mesh metal lath DRAINAGE MAT ATTACHMENT Wind-lock ULP-3W2- UW-2 screws spaced a max. of 8 inches o.c. in both directions into sheathing Wind-lock ULP-3W2- UW-2 screws spaced a max. of 8 inches o.c. in both directions into sheathing Wind-lock ULP-3S2- US-2 screws spaced a max. of 8 inches o.c. along studs Wind-lock ULP-3W2- UW-2 screws spaced a max. of 8 inches o.c. along studs DRAINAGE INSULATION BOARD ATTACHMENT Wind-Devil UWLM-2 screws spaced per Figure 2 Wind-Devil-2 UST-3 screws spaced a max. of 8 inches o. c. along studs

ESR-1030 Most Widely Accepted and Trusted Page 6 of 12 FIGURE 1 CUTAWAY VIEW OF THE STO RAINSCREEN SYSTEM COMPONENTS INSTALLATION DETAIL

ESR-1030 Most Widely Accepted and Trusted Page 7 of 12 FASTENER SELECTION FASTENER SELECTION EPS BOARD THICKNESS (inches) WIND DEVIL 2 FASTENER LENGTH (inches) EPS BOARD THICKNESS (inches) WIND DEVIL FASTENER LENGTH (inches) 1 1 / 2 UST-3 2 5 / 8 1 1 / 2 UWLM-2 2 2 UST-4 3 2 UWLM-3 2 1 / 2 2 1 / 2 UST-5 4 2 1 / 2 UWLM-4 3 3 UST-6 4 3 / 8 3 UWLM-5 3 3 / 4 3 1 / 2 UST-7 5 3 1 / 2 UWLM-7 5 4 UST-8 6 4 UWLM-7 5 For SI: 1 inch = 25.4 mm. FIGURE 2 STO DRAINAGE INSULATION BOARD FASTENING DETAILS (RAINSCREEN)

ESR-1030 Most Widely Accepted and Trusted Page 8 of 12 FIGURE 3 CUTAWAY VIEW OF STO RAINSCREEN II SYSTEM COMPONENTS INSTALLATION DETAILS Fastener Attachment Pattern for Direct Attachment of Drainage Mat into Solid Substrates Fastener Attachment Pattern for Direct Attachment of Drainage Mat into Studs FIGURE 4 STO RAINSCREEN II INSULATION BOARD FASTENING DETAILS

ESR-1030 Most Widely Accepted and Trusted Page 9 of 12 FIGURE 5 TYPICAL INSTALLATION DETAILS

ESR-1030 Most Widely Accepted and Trusted Page 10 of 12 FIGURE 5 TYPICAL INSTALLATION DETAILS (Continued)

ESR-1030 Most Widely Accepted and Trusted Page 11 of 12 Completion Date: (EIFS CONTRACTOR NAME) THE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) INSTALLED ON THE STRUCTURE LOCATED AT THE ADDRESS INDICATED BELOW: CONFORMS TO (EIFS MANUFACTURER NAME) RECOMMENDED INSTALLATION PRACTICES AND SECTION (S) OF ICC-ES EVALUATION REPORT ESR-1030. Address of Structure: INSTALLATION Product Component Names: Adhesive(s) Fasteners (mech) Base Coat Reinforcing Fabric Finish Coat(s) CONFORMS A. Substrate Type and Tolerance B. Weather-resistive Barrier C. EIFS 1. Adhesive and/or Fasteners 2. Insulation 3. Reinforcing Fabric 4. Base Coat 5. Finish D. The information entered above is offered in testimony that the EIFS installation conforms with the EIFS manufacturer's installation methods and procedures, and the EIFS manufacturer's ICC-ES evaluation report. NOTE: An installation card shall be received from the Sealant Installer indicating that the sealant installation conforms with the ICC-ES evaluation report and sealant manufacturer's installation methods and procedures must accompany this declaration. EIFS Contractor Company Name and Address: Signature of responsible Officer: Type Name and Title of Officer: Telephone Number: ( ) cc: Original: Building Department (Must be submitted with sealant Copy: EIFS Manufacturer installer declaration.) FIGURE 6

ESR-1030 Most Widely Accepted and Trusted Page 12 of 12 Completion Date: (SEALANT INSTALLER NAME) THE SEALANT INSTALLED IN CONJUNCTION WITH AN EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) INSTALLED ON THE STRUCTURE LOCATED AT THE ADDRESS INDICATED BELOW: CONFORMS TO (EIFS MANUFACTURER NAME) AND (SEALANT MANUFACTURER'S NAME) RECOMMENDED INSTALLATION PRACTICES AND SECTION(S) OF ICC-ES EVALUATION REPORT ESR-1030. Address of Structure: Product Component Names: Primer(s) Sealers Bond Breakers Sealant Materials INSTALLATION CONFORMS A. Designer's requirements, details and instructions B. Sealant manufacturer's details and requirements C. Exterior insulation manufacturer's requirements D. The information entered above is offered in testimony that the Sealant installation conforms with the sealant manufacturer's installation methods and procedures, and the EIFS manufacturer's ICC-ES evaluation report. Sealant Installer Company Name and Address: Signature of responsible Officer: Type Name and Title of Officer: Telephone Number: ( ) cc: Original: Building Department (Must be submitted with EIFS Copies: EIFS Manufacturer contractor declaration.) EIFS Contractor Sealant Manufacturer FIGURE 7