ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING

Similar documents
ENGINEERING SPECIFICATION FIBERGRATE 1 INCH DEEP MICRO-MESH MOLDED GRATING SECTION 06610

ENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610

ENGINEERING SPECIFICATION FIBERGRATE 62% OPEN AREA/ADA COMPLIANT MOLDED GRATING. January 5,

ENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

ENGINEERING SPECIFICATION

ENGINEERING SPECIFICATION PULTRUDED FIBERGLASS GRATING SAFE-T-SPAN HIGH LOAD CAPACITY (47% OPEN AREA) VINYL ESTER. January 24,

ENGINEERING SPECIFICATION NON-MAGNETIC RAISED FLOOR SYSTEM FOR MRI ROOM APPLICATIONS

ENGINEERING SPECIFICATION PULTRUDED DYNADECK INTERLOCKING FLOORING

ENGINEERING SPECIFICATION PULTRUDED HIGH LOAD CAPACITY (HI) SAFE-T-SPAN FIBERGLASS GRATING. January 24,

SECTION FRP GRATING, HANDRAIL, AND SUPPORTS

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. March 16,

GLASSFIBER REINFORCED PLASTICS (GRP) MOULDED AND PULTRUDED GRATING

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS GUARDRAIL AND HANDRAIL. January 24,

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS GUARDRAIL AND HANDRAIL. January 24,

Re-Grate Pultruded Grating

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Molded Grating and Treads Products and Fabrications REVISED 11.

PRODUCT SPECIFICATIONS PULTRUDED GRATING AND TREADS SECTION PART 1 GENERAL

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Pultruded Grating/Treads and Fabrications REVISED

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Architectural Decking panels and Fabrications REVISED 11.

Molded Grating Selection & Details

Premium Fiberglass Products. QUALITY SPEED RELIABILITY Molded - Pultruded - Treads - Structurals - Ladders - Handrails

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

EXCLUSIVELY MOLDED FIBERGLASS GRATING

SECTION ARCHITECTURAL FIBERGLASS

SECTION ARCHITECTURAL FIBERGLASS

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Hollow Core Building Panels Products and Fabrications REVISED 11.

Pultruded Grating. ADDED SAFETY - durable grit surface, permanently bonded, and baked to the grating surface, for a safe, slip-resistant walkway.

FRP Classic TM Cast Stone Fiberglass Fabrications Architectural Specification

SECTION FIBERGLASS REINFORCED PLASTIC (FRP) DOORS AND FIBERGLASS RESIN TRANSFER MOLDED DOOR FRAMES

FRP Floor Panels Standard Specification

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

Decorative Fiberglass Reinforced Wall Panels

FIBERGLASS REINFORCED PLASTIC (FRP) LAUNDER COVERS

GRATING PRODUCTS. PROGrid and PROGrate

PROForms. Specifications SECTION FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS

FRP REBAR: MDOT APPROVED

UNIFIED FACILITIES GUIDE SPECIFICATIONS

FRP Baffle Wall Standard Specification-Section 11350

PULTRUDED FIBERGLASS GRATING

Dynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.

SECTION DETECTABLE GUIDE TACTILES

Powell. Sodium Hypochlorite Fiberglass Reinforced Plastic (FRP) Storage Tanks

First Class Building Products, Inc.

Thickness Mesh Size Panel Size Color Resin Type

Phenolic Exterior Wall Cladding

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Fiberglass Molded Products

SECTION SOUND-ABSORPTIVE PANELS

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

Pedestals for Molded Grating

MODEL CP 12 HURRICANE SINGLE FBC +/- 70 psf CERTIFIED DOOR (Not for HVHZ) MANUFACTURED IN THE UNITED STATES OF AMERICA

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

SECTION SECURITY PROTECTION PART 1 GENERAL

SECTION ALUMINUM HANDRAIL SYSTEMS


SECTION STAINLESS STEEL WALL PANELS

SECTION FIBERGLASS WEIRS AND BAFFLES

SECTION EXTERIOR GRILLS AND SCREENS

Guidelines for the Engineer & Designer

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Installation Instructions

PRODUCT SPECIFICATIONS

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION PRECAST CONCRETE COVER SYSTEM

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Skylight & Sidelight Panels

Fiberglass Molded Products

FIBERGLASS WET WELLS

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

Expansion Joint Covers (079513)

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

WALL & CEILING LINER PANELS

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

13340 FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE

Ultra Aluminum Fence, Rail & Gate Specifications

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION COLD-FORMED METAL TRUSSES

SECTION ENTRANCE FLOOR GRILLES SPECIFICATIONS

MODEL CP 10 MOLDED LITE HURRICANE DOOR MANUFACTURED IN THE UNITED STATES OF AMERICA

DORTEK INC. SPECIFICATION MOLDED FIBERGLASS DOORS AND FRAMES

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

EDON CORPORATION 1160 Easton Rd. Horsham, PA tel. (215) or fax. (215) edon.com

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

Product Specifications

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

A. American Society for Testing and Materials (ASTM):

Transcription:

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING 1

PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING A. The CONTRACTOR shall furnish, fabricate (where necessary), and install all fiberglass reinforced plastic (FRP) items, with all appurtenances, accessories and incidentals necessary to produce a complete, operable and serviceable installation as shown on the Contract Drawings and as specified herein, and in accordance with the requirements of the Contract Documents. 1.2 REFERENCES A. The publications listed below (latest revision applicable) form a part of this specification to the extent referenced herein. The publications are referred to within the text by the designation only. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) Test Methods: ASTM D 635 Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position ASTM E 84 Surface Burning Characteristics of Building Materials 1.3 CONTRACTOR SUBMITTALS A. The CONTRACTOR shall furnish shop drawings of all fabricated gratings and accessories in accordance with the provisions of this Section. B. The CONTRACTOR shall furnish manufacturer's shop drawings clearly showing material sizes, types, styles, part or catalog numbers, complete details for the fabrication and erection of components including, but not limited to, location, lengths, type and sizes of fasteners, clip angles, member sizes, and connection details. C. The CONTRACTOR shall submit the manufacturer s published literature including structural design data, structural properties data, grating load/deflection tables, corrosion resistance tables, certificates of compliance, test reports as applicable,

concrete anchor systems and their allowable load tables, and design calculations for systems not sized or designed in the contract documents. D. The CONTRACTOR may be requested to submit sample pieces of each item specified herein for acceptance by the ENGINEER as to quality and color. Sample pieces shall be manufactured by the method to be used in the WORK. 1.4 QUALITY ASSURANCE A. All items to be provided under this Section shall be furnished only by manufacturers having a minimum of ten (10) years experience in the design and manufacture of similar products and systems. Additionally, if requested, a record of at least five (5) previous, separate, similar successful installations in the last five (5) years shall be provided. B. Manufacturer shall offer a 3 year limited warranty on all FRP products against defects in materials and workmanship. C. Manufacturer shall be certified to the ISO 9001-2000 standard. D. Manufacturer shall provide proof of certification from at least two other quality assurance programs for its facilities or products (UL, DNV, ABS, USCG, AARR). 1.5 PRODUCT DELIVERY AND STORAGE A. Delivery of Materials: Manufactured materials shall be delivered in original, unbroken pallets, packages, containers, or bundles bearing the label of the manufacturer. Adhesives, resins and their catalysts and hardeners shall be crated or boxed separately and noted as such to facilitate their movement to a dry indoor storage facility. B. Storage of Products: All materials shall be carefully handled to prevent them from abrasion, cracking, chipping, twisting, other deformations, and other types of damage. Adhesives, resins and their catalysts are to be stored in dry indoor storage facilities between 70 and 85 degrees Fahrenheit (21 to 29 degrees Celsius) until they are required. PART 2 - PRODUCTS 2.1 MANUFACTURER A. Molded gratings shall be Fibergrate as manufactured by

Fibergrate Composite Structures Inc. 5151 Belt Line Road, Suite 700 Dallas, Texas 75254-7028 USA (800) 527-4043 (972) 250-1530 Fax 2.2 GENERAL A. All FRP items furnished under this Section shall be composed of fiberglass reinforcement and resin in qualities, quantities, properties, arrangements and dimensions as necessary to meet the design requirements and dimensions as specified in the Contract Documents. B. Fiberglass reinforcement shall be continuous roving in sufficient quantities as needed by the application and/or physical properties required. C. Resin shall be {Vinyl Ester, Isophthalic Polyester, Polyester or Modified Acrylic - choose one}, with chemical formulations as necessary to provide the corrosion resistance, strength and other physical properties as required. D. All finished surfaces of FRP items and fabrications shall be smooth, resin-rich, free of voids and without dry spots, cracks, crazes or unreinforced areas. All glass fibers shall be well covered with resin to protect against their exposure due to wear or weathering. E. All grating products shall have a tested flame spread rating of 25 or less per ASTM E-84 Tunnel Test. Gratings shall also have tested burn time of less than 30 seconds and an extent of burn rate of less than or equal to 10 millimeters per ASTM D635. F. All mechanical grating clips shall be manufactured of Type 316SS (stainless steel). 2.3 MOLDED FRP GRATING A. Manufacture: Grating shall be of a one piece molded construction with tops and bottoms of bearing bars and cross bars in the same plane. Grating shall have (a square mesh pattern providing bidirectional strength or a rectangular mesh pattern providing unidirectional strength - choose one). Grating shall be reinforced with continuous rovings of equal number of layers in each direction. The top layer of reinforcement shall be no more than 1/8" below the top surface of the grating so as to provide maximum stiffness and prevent resin chipping of unreinforced surfaces. Percentage of glass (by weight) shall not exceed 35% so as to achieve maximum corrosion resistance, and as required to maintain the structural requirements of the

CONTRACT. After molding, no dry glass fibers shall be visible on any surface of bearing bars or cross bars. All bars shall be smooth and uniform with no evidence of fiber orientation irregularities, interlaminar voids, porosity, resin rich or resin starved areas. B. Non slip surfacing: Grating shall be manufactured with a concave, meniscus profile on the top of each bar providing maximum slip resistance. C. Grating bar intersections are to be filleted to a minimum radius of 1/16 to eliminate local stress concentrations and the possibility of resin cracking at these locations. D. Fire rating: Grating shall be fire retardant with a tested flame spread rating of 25 or less when tested in accordance with ASTM E 84. Data performed only on the resin shall not be acceptable. E. Resin system: The resin system used in the manufacture of the grating shall be {Vi- Corr, IFR, FGI, Corvex, ELS, XFR or Super Vi-Corr - choose one}. Manufacturer may be required to submit corrosion data from tests performed on actual grating products in standard chemical environments. Corrosion resistance data of the base resin from the manufacturer is not a true indicator of grating product corrosion resistance and shall not be accepted. Vi-Corr and IFR products shall be U.L. listed if available for the grid configuration specified. F. Color:{varies by resin - consult your catalog} G. G. Depth: " with a tolerance of plus or minus 1/16". H. H. Mesh Configuration: " x " with a tolerance of plus or minus 1/16" mesh centerline to centerline I. Load/Deflection: Grating design loads shall be less than manufacturers published maximum recommended loads. Maximum recommended loads shall be determined by acoustic emission testing. Grating shall be designed for a uniform load of 100 psf or concentrated load of 300 lb. Deflection is not to exceed 0.375 or L/D = 120, whichever is less. J. The manufacturer shall certify that the stiffness of all panels manufactured are never more than 2.5% below the published load-deflection values. K. Substitutions: Other products of equal strength, stiffness, corrosion resistance and overall quality may be submitted with the proper supporting data to the engineer for

approval. 2.4 GRATING FABRICATION A. Measurements: Grating supplied shall meet the dimensional requirements and tolerances as shown or specified. The Contractor shall provide and/or verify measurements in field for work fabricated to fit field conditions as required by grating manufacturer to complete the work. When field dimensions are not required, contractor shall determine correct size and locations of required holes or cutouts from field dimensions before grating fabrication. B. Layout: Each grating section shall be readily removable, except where indicated on drawings. Manufacturer to provide openings and holes where located on the contract drawings. Grating openings which fit around protrusions (pipes, cables, machinery, etc.) shall be discontinuous at approximately the centerline of opening so each section of grating is readily removable. C. Sealing: All shop fabricated grating cuts shall be coated with vinyl ester resin to provide maximum corrosion resistance. All field fabricated grating cuts shall be coated similarly by the contractor in accordance with the manufacturer's instructions. D. Hardware: Type 316 stainless steel hold-down clips shall be provided and spaced at maximum of four feet apart with a minimum of four per piece of grating, or as recommended by the manufacturer. PART 3 - EXECUTION 3.1 INSPECTION A. Shop inspection is authorized as required by the Owner and shall be at Owner's expense. The fabricator shall give ample notice to Contractor prior to the beginning of any fabrication work so that inspection may be provided. The grating shall be as free, as commercially possible, from visual defects such as foreign inclusions, delamination, blisters, resin burns, air bubbles and pits. The surface shall have a smooth finish (except for grit top surfaces). 3.2 INSTALLATION A. Contractor shall install gratings in accordance with manufacturer s assembly drawings. Fasten grating panels securely in place with hold-down fasteners as specified herein. Field cut and drill fiberglass reinforced plastic products with carbide or diamond tipped bits and blades. Seal cut or drilled surfaces in accordance

with manufacturer's instructions. Follow manufacturer's instructions when cutting or drilling fiberglass products or using resin products; provide adequate ventilation.