Use of levitating liquid micro-droplets as tracers to study the evaporation in the vicinity of the contact line

Similar documents
STUDYING THE DYNAMICS OF BREAKDOWN OF THIN HORIZONTAL LIQUID LAYERS WITH LOCAL HEATING

Breakdown dynamics of a horizontal evaporating liquid layer when heated locally

STUDYING OF THE CONTACT ANGLE HYSTERESIS ON VARIOUS SURFACES

DEPOSITION AND INVESTIGATION OF HYDROPHOBIC COATINGS

Investigation of the properties of different surfaces used in evaporation systems

Texture and Wettability of Metallic Lotus Leaves

An XPS and Atomic Force Microscopy Study of the Micro-Wetting Behavior of Water on Pure Chromium* 1

Evaluation of unusual change in contact angle between MgO and molten magnesium

The influence of insulation of walls of industrial objects on thermal regime at the heating system of gas infrared radiators

Experimental and Numerical Studies of Liquid Dispersal from a Soft Projectile Impacting a Wall

Splat formation in plasma-spray coating process*

In situ, Non-contact monitoring of Powder Compacts during Polymer Removal

Performance Improvement on Water-cooled Cold-Plate

Catherine G. Reyes, Anshul Sharma and Jan P.F. Lagerwall. July 18, Complete description of experimental details

Visualization and Control of Particulate Contamination Phenomena in a Plasma Enhanced CVD Reactor

Mater. Res. Soc. Symp. Proc. Vol Materials Research Society

Hydrodynamics of Drop Impact and Spray Cooling through Nanofiber Mats

Influence of Warm Oxide Layer on Wettability and Contact Angle for Heat Transport Devices

Chem 355 Jasperse DISTILLATION

Enhancement of heat transfer rate in pool boiling on Nichrome wire by addition of surfactants in pure water

Unusual Wetting of Liquid Bismuth on a Surface-Porous Copper Substrate Fabricated by Oxidation-Reduction Process

Influence of temperature and glass composition on aluminum nitride contact angle

Discharge Characteristics of DC Arc Water Plasma for Environmental Applications

Investigation of Anode Attachment Area in Water/Argon Stabilized Plasma Arc

Observation and numerical simulation of melt pool dynamic and beam powder interaction during selective electron beam melting

Analysis of Surface Properties of Al 2 O 3 Coating over Mild Steel Using Plasma Spray Process

Visualization of pool boiling on plain micro-fins and micro- fins with sintered perforated foil

Supporting Information

Supplementary Figure 1 Optical properties of the DLS. (a) The transmittance of water and

A Study of the Formation Modes of Nanosized Oxide Structures of Gallium Arsenide by Local Anodic Oxidation

THE EFFECT OF LEAF ORIENTATION ON SPRAY RETENTION ON BLACKGRASS. M. Massinon, H.H. Boukhalfa, P.-Y. Maréchal, F. Lebeau ABSTRACT

Welding and post weld heat treatment of 2.25%Cr-1%Mo steel

ELECTRONIC SUPPLEMENTARY INFORMATION. On-Skin Liquid Metal Inertial Sensor

Silicon Microparticle Ejection Using Mist-jet Technology

A Study of the Formation Modes of Nanosized Oxide Structures of Gallium Arsenide by Local Anodic Oxidation

HEAT TRANSFER IN POROUS SURFACES OF EVAPORATORS OF HEAT MACHINES AND DEVICES

Modification of Glass Surface by Atmospheric Pressure Plasma

Recent Progress in Droplet-Based Manufacturing Research

INVESTIGATION OF WATER DROP AT FREE-FALL ON A HEATED SUBSTRATE K. A. Batishcheva, E. G. Orlova, D. V. Feoktistov Tomsk Polytechnic University

Liquid droplets on hot surfaces

Progress Report. Development of a High Heat Flux Supercooler Using Carbon Foam. Walter Yuen. February, 12, 2008

Thermo Scientific ARL EQUINOX 100. X-ray Diffractometers

Influence of Water Temperature on Cooling Intensity of Mist Nozzles in Continuous Casting

Cu/synthetic and impact-diamond composite heatconducting

Mechanism of Building-Up Deposited Layer during Electro-Spark Deposition

Supplementary Materials for

FORMING THE COMPOSITION OF UNDERGROUND COAL GASIFICATION PRODUCTS IN THE SIMULATION OF VARIOUS HEAT AND MASS TRANSFER CONDITIONS IN THE COAL SEAM

Thermo Scientific ARL EQUINOX X-ray Diffractometers

Light-driven micro-tool equipped with a syringe function

3. EXPERIMENTAL PROCEDURE

The Study of Solid-Liquid Phase Equilibria With Phase Technology Analyzers

INVESTIGATION OF THE WETTING CHARACTERISTICS OF LIQUID Fe-19%Cr-10%Ni ALLOYS ON THE ALUMINA AND DOLOMITE SUBSTRATES AT 1873 K

acta physica slovaca vol. 55 No. 4, August 2005 THERMIONIV VACUUM ARC NEW TECHNIQUE FOR HIGH PURITY CARBON THIN FILM DEPOSITION

Title. Author(s)Shimozuma, M.; Date, H.; Iwasaki, T.; Tagashira, H.; Issue Date Doc URL. Type. Note. Additional There Information

Effects of side walls on facade flame entrainment and flame height from opening in compartment fires

VISUALIZATION OF TRANSIENT INTERACTION PHENOMENA BETWEEN DROPLETS AND HOT WALLS AROUND LEIDENFROST TEMPERATURE FOR SUS304

Microstructural characterisation of interfaces in magnetic pulse welded aluminum/aluminum joints

Title Using Neutron Radiography and Liqui. Author(s) Ito, Daisuke; Saito, Yasushi; Kawab. Citation Physics Procedia (2015), 69:

SUPPLEMENTARY INFORMATION

Heat Transfer Simulation to Determine the Impact of Al-5Mg Arc Sprayed Coating onto 7075 T6 Al Alloy Fatigue Performance

Performance of an Air-Assist Nozzle Using Heated Air

Application of the interference method of studying the surface for quality control and internal structure of the luminescent crystals and

COOLING TECHNOLOGY INSTITUTE

Interfacial state and characteristics of cold-sprayed copper coatings on aluminum substrate

Behavior of a Jet Issuing Diagonally Upward into Two-Layer Density-Stratified Fluid in a Cylindrical Tank

ANALYSIS FOR NATURAL CIRCULATION LOOP

Two-Phase Distribution of R-134a in a Header of a Parallel Flow Heat Exchanger

Studies on Atmospheric Non-Thermal Plasma Jet Device

Formation of Droplets on Thin Film Surface in Pulsed Laser Deposition Using Metal Targets*

SUPPLEMENTARY INFORMATION

Chapter 3: Powders Production and Characterization

Aqueous-Based Extrusion Fabrication of Ceramics on Demand

Morphology of Thin Aluminum Film Grown by DC Magnetron Sputtering onto SiO 2 on Si(100) Substrate

Experimental investigation of the heat transfer process between a tube bundle and an upward aqueous foam flow

Dr. J. Wolters. FZJ-ZAT-379 January Forschungszentrum Jülich GmbH, FZJ

Frictional Coefficients of the Passive Titanium Surfaces Evaluated with In-situ and Ex-situ Nano-scratching Tests

INVESTIGATION INTO THE POOL-BOILING CHARACTERISTICS OF GOLD NANOFLUIDS. University of Missouri-Columbia. In Partial Fulfillment

Department of Mechanical Engineering, University of Washington, Seattle, WA, 98195

QUENCH SEVERITY AND KINETICS OF WETTING OF VEGETABLE OIL BLENDS AND NANOFLUIDS FOR HEAT TREATMENT

Flow visualization at suction of a twin screw compressor

A plasma cloud charge sensor for pulse keyhole process control

AND TESTING OF A CARBON FOAM BASED SUPERCOOLER FOR HIGH HEAT FLUX COOLING IN OPTOELECTRONIC PACKAGES

Dynamic Plasma-Liquid System with Discharge in Reverse Vortex Flow of Tornado Type

Visualization of the tip vortices in a wind turbine wake

doi: /s z

Applicability of Minichannel Cooling Fins to the Next Generation Power Devices as a Single-Phase-Flow Heat Transfer Device

In-Process Monitoring and Adaptive Control in Micro Welding with a Single-Mode Fiber Laser.

SiC crystal growth from vapor

Large scale fire test on tunnel segment: Real boundary conditions in order to evaluate spalling sensitivity and fire resistance

IJREAT International Journal of Research in Engineering & Advanced Technology, Volume 2, Issue 2, Apr-May, 2014 ISSN:

ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE

Size-velocity pdfs for Drop Fragments Formed via Multi-mode Breakup

MEASURING MICROPARTICLE IMPACT CHARACTERISTICS UNDER REALISTIC GAS TURBINE CONDITIONS. A.G. Friedman, W.F. Ng Virginia Tech

E APPENDIX. The following problems are intended for solution using finite element. Problems for Computer Solution E.1 CHAPTER 3

High Sensitive NDE of Subsurface Local Damages in Thermal Barrier Coating Systems by the Laser Speckle Method

Advance on non-equilibrium plasma jets

High-Speed Infrared Imaging for Characterization of the Additive Manufacturing Process

A NANO-MICRO-COMPOSITE SENSOR FOR THE MEASUREMENT OF FLOW SHEAR STRESS

Comparison between micrometer and millimetre sized metal and ceramic lamellas, for a better understanding of the spray process.

Computer simulation of processes in the dead end furnace

Transcription:

Use of levitating liquid micro-droplets as tracers to study the evaporation in the vicinity of the contact line Dmitry Zaitsev 1,2*, Dmitry Kirichenko 1,3, and Oleg Kabov 1,2 1 Institute of Thermophysics, 630090 Novosibirsk, Russia 2 National Research Tomsk Polytechnic University, 634050 Tomsk, Russia 3 Novosibirsk State University, 630090 Novosibirsk, Russia Abstract. Self-organization of a cloud of liquid micro-droplets into an ordered two-dimensional array, levitating over a heated layer of liquid due to upward vapor flow, has been observed in several recent experimental works. In the present paper, the levitating micro-droplet array is studied under the condition when the liquid layer ruptures and a dry spot form on the heater. It has been found, that when the levitating micro-droplets are moving from wetted heater area to dry heater area and passing over the contact line, the micro-droplets levitation height is drastically increased, which is indicative of the intensive evaporation occurring in the region of the contact line. 1 Introduction A spatially ordered structure of micro-droplets levitating above the free surface of a liquid layer spot-heated from below was discovered in [1]. The array consists of several of hundreds of drops packed into one layer, forming a hexagonal structure. The drop diameter is on the order of 10 μm; the distance between the drops is of several drop diameters, while the drops levitation height above the liquid surface is comparable to the drop size. The possible mechanism of micro-drops levitation is the Stokes force acting onto a drop from the vapor flow arising from the heated liquid surface [2, 3]. Figure 1 shows a typical image of levitating micro-droplet array over a heated layer of liquid, obtained in the present study. Among the effective solutions for removal of high heat fluxes, there are systems of spray cooling [4, 5] as well as systems using stratified two-phase flows in micro-/minichannels [6, 7]. Intensive evaporation from the contact line region can be a key factor for the efficiency of these systems. In spray cooling, the impact and subsequent spreading of droplets on the surface results in formation of multiple contact lines. Strong correlation between the heat transfer rate and the contact line length per unit area is observed [5, 8]. In stratified two-phase flows, the highest heat transfer rate is reached in the regime when local dry areas on the heater quickly appear and disappear [9], thus forming multiple contact lines. * Corresponding author: zaitsev@itp.nsc.ru The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

In this paper the levitating micro-droplet array is used as natural tracers to study the evaporation in the vicinity of the contact line at the boundary of a dry spot formed in a horizontal water layer heated from below. A relatively large heater of size 10 10 mm 2 is used (in papers [1-3] the size of the heater was around 1 mm). With the help of high-speed imaging technique, we study the behaviour of the droplet array as it approaches and passes over the contact line region. Fig. 1. Top view of an array of levitating micro-droplets, formed over a heated layer of water (heater of size 10 10 mm 2, heat flux of 27 W/cm 2, water layer thickness of 0.4 mm). 2 Experimental setup Schematic and photograph of the experimental setup are presented in Fig. 2. The test section is a stainless steel plate 40 40 5 mm 3 in size with a flush-embedded 10 10 mm 2 copper rod, electrically heated by a nichrome wire. A layer of insulation material (mineral wool) is superimposed over the wire (nichrome wire with insulation material are not shown in Fig.2). The heater surface temperature is measured at several points by thermocouples with the accuracy of 0.1 K and frequency of 1 Hz. According to the measurements, the condition T w =const is always met along the copper surface. In the experiments, T w was varied from 75 to 100 C. The heat flux is determined by the electric power released at the nichrome wire. Ultra-pure degassed distilled water (Merck Millipore) with the initial temperature of 25 C is used as the working liquid. The test section is installed horizontally and open to the atmosphere; the temperature of ambient air is 25±2 С. The working surface of the test section was mechanically polished. The morphology of the surface was analysed using scanning electron microscope (JEOL JSM6700F) and atomic force microscope (Solver Pro NT MDT), Fig.3. The root mean square (RMS) surface roughness, measured on a 22 μm 2 area of the heater surface, was found to be 500 nm, with the average roughness of 0.394 nm. Thus, the roughness of the working surface is negligible compared to typical micro-droplet size (10-30 μm) and typical micro-droplet levitation height above the dry substrate (5-15 μm, see below). The equilibrium contact angle on the copper surface was measured at different points by the method of a sessile liquid drop at the room temperature of 25±2 C. To obtain the profile of the drop surface, the shadow method was used with a collimated light source and digital camera Nikon D800 having resolution of 6 micron/pixel. The resulting images were processed using the software by KRUSS. The advanced static contact angle measured at different points over the surface of the copper heater was 74±9, whereas the receding contact angle was close to zero (<10 ). 2

MATEC Web of Conferences 92, 01026 (2017) DOI: 10.1051/ matecconf/20179201026 (a) (b) Fig. 2. Schematic (a) and photograph (b) of the experimental setup. (a) (b) Fig. 3. Image of the heater surface obtained using scanning electron microscope (a), and height histogram obtained using atomic force microscope (b). Optical recording was made with a high-speed camera FASTCAM SA1.1 (5600 fps with resolution of 1024x1024 pixel) coupled with a microscope objective through a set of 3

extension tubes and bellows. Field of view of the camera was 800x800 μm 2 (resolution of 0.78 μm per pixel). The optical axis of the camera was aligned at an angle of 5 with respect to the horizon. The experimental procedure is as follows: 1) A predetermined volume of the working liquid is deposited with a syringe onto the working surface to form a liquid layer with the initial thickness of 400 μm. 2) With the help of an air jet a dry spot (about 1 mm in size) is formed on the copper surface. 3) The optical system is focused onto the contact line at the edge of the dry spot. 4) The heater is switched on, which induces formation of micro-drops levitating over the heated layer of liquid. 5) When the levitating micro-drops move to the dry spot, the recording is started. 3 Experimental results Increase of the heat flux induces formation of the array of micro-drops levitating over the heated liquid layer (typical top view is shown in Fig. 1). Usually, the array was of an elliptical shape with the size varying approximately from 500 to 4000 μm. In most of previous studies [1-3] the micro-droplet array was localized due to the use of localized heating (the size of the heater was around 1 mm), and as such the size of the array roughly coincided with the size of the heater. In contrast, we use a heater having size much larger than typical size of the cluster, which allows us to obtain larger arrays of droplets. Upon the formation of a dry spot in the liquid layer, the micro-droplets move down the slope of the interface under the action of gravity toward the dry area. As they get close to the contact line, the height of their levitation increases several times and eventually the micro-droplets turn out to be levitating over the heater surface, Fig. 4. After that, they disappear by evaporation within a second or so while continuing to levitate over the dry substrate. Fig. 4. Side view of micro-droplets flying over the contact line (substrate temperature of 95 C). We revealed three common scenarios of micro-droplets transition from the wetted area to the dry area. First, a droplet can simply fly over the contact line with substantial increase of its levitation height, as depicted in Fig. 5a. The result shown in Fig. 5a was obtained for a droplet of diameter of 16 μm and substrate temperature of 79 C. The second common scenario is when the droplet is following a circular-like trajectory in the vicinity of the contact line, with one or more full rotations, before eventually getting out of this cycle and flying to the dry area, Fig. 5b (droplet size is 20 μm, substrate temperature is 81 C). This scenario can be connected with the vortex flow of the gas-vapor mixture formed near the contact line. Finally, some droplets can be levitating at a fixed location above the contact line, as shown in Fig. 5c (droplet diameter is 26 μm, substrate temperature is 97 C). In this 4

case, the dynamic force of the air-vapor flow from the contact line is balanced with the gravity force acting on the droplet. We would like to emphasize that while actual snapshots, shown in Fig. 5, were made at slightly different conditions, all three scenarios were observed under a wide variety of substrate temperatures (from 75 to 100 C). (a) (b) (c) Fig. 5. Three common scenarios of micro-droplets transition from wetted area to dry area: simple flyover above the contact line (a), fly-over with circular trajectory (b), and levitating at a fixed location (c). Positions of micro-droplets are shown at equal time intervals of 0.02 s. Micro-droplets are drawn in the scale. 4 Conclusions Levitating micro-droplets, formed in the upward vapor flow above the heated liquid surface, are used as tracers to study the evaporation in the vicinity of the contact line. It has been found, that while the levitating micro-droplets are passing from the wetted substrate area over the contact line to the dry substrate area, the droplets levitation height is increased several times. From this we conclude that the specific evaporation rate in the vicinity of the contact line must be several times higher than that at a distance from the contact line. Three common micro-droplet trajectories are identified: 1) simple fly-over, 2) fly-over with circular motion, and 3) nearly steady-state levitation. This work was supported by the Russian Science Foundation, project No. 1419-01755. References 1. A.A. Fedorets, JETP Lett. 79, 372 (2004) 2. A.A. Fedorets, I.V. Marchuk and O.A. Kabov, Tech. Phys. Lett. 37, 116 (2011) 3. A.A. Fedorets, I.V. Marchuk and O.A. Kabov, JETP Lett. 99, 266 (2014) 4. B. Horacek, K.T.Kiger, J. Kim, Int. J. Heat Mass Tran. 48, 1425 (2005) 5. J. Kim, Int. Journal Heat Fluid Flow 28, 753 (2006) 6. O.A. Kabov, Yu.V. Lyulin, I.V. Marchuk, D.V. Zaitsev, Int. J. Heat Fluid Fl. 28, 103 (2007) 7. Zaitsev D.V., Rodionov D.A. and Kabov O.A. Tech. Phys. Lett. 35, 680 (2009) 8. A.A. Semenov, D.V. Feoktistov, D.V. Zaitsev, G.V. Kuznetsov, O.A. Kabov Thermophys. Aeromech. 22, 771 (2015) 9. O.A. Kabov, D.V. Zaitsev, V.V. Cheverda, A. Bar-Cohen, Exp. Therm Fluid Sci. 35, 825 (2011) 5