SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

Similar documents
A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

ARCH 478 OFFICE BUILDING SECTION GLAZING

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION SERIES ALL GLASS ENTRANCES

B. Mirror glass for toilet rooms is specified in Section "Toilet Accessories."

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Repair Maintenance Hangar Phase II August 2010

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Alabama A&M University Laundry Building at Normal Hill Apartments Project No ADDENDUM NUMBER 4

SECTION GLAZING ADDENDUM 10 APRIL 20, 2011

JE Berkowitz, L.P. (updated ) B. The basis of design is the JEB Invisiwall Wall (Point Supported) by JE Berkowitz, LP. C.

SECTION GLAZING

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Section A2 Table of Contents ALL GLASS ENTRANCES

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

JONES AIRWAYS, LLC CLEVELAND REGIONAL JETPORT SECTION GLAZING

OPACI-COAT Water-base Silicone Glass Coating

SECTION DEMOUNTABLE WALLS SKY WALLS - STRATUS SYSTEM

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

SECTION GLASS AND GLAZING. A. Flat Glass Marketing Association (FGMA): Glazing Manual, 1986 Edition.

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION / METAL FRAMED SKYLIGHTS

SECTION GLAZING. A. Section Includes: 1. Glass for other sections referencing this Section.

.2 Section Waste Management and Disposal.

OPACI-COAT Water-base Silicone Glass Coating

JE Berkowitz, L.P. Architectural Glazing Guide Specification for Enviroscreen Silk-Screened Glass

Michigan State University Construction Standards PAGE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION LED LAMINATED GLASS

SECTION GLAZING

Note: Any verbiage written in red needs to be specified. All other options should be deleted

SECTION GLAZING

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

A. Section includes glazing for the following products and applications and of the following types:

ADDENDUM NUMBER TWO. for SWIM TEAM LOCKER ROOM RENOVATIONS REBID UNIVERSITY OF SOUTH CAROLINA COLUMBIA, SOUTH CAROLINA. DATE OF ISSUE: June 19, 2014

FUZION by Andrew Pearson. Glass Stairs

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

A. Glass Manufacturers: Firms that produce primary glass, fabricated glass, or both, as defined in referenced glazing publications.

A. Access doors and frames are part of an access door and frame allowance.

SECTION GLASS AND GLAZING (WINDOWS)

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass

2004 MASTER FORMAT SECTION Façade Panels

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

SECTION METAL FRAMED SKYLIGHTS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

SECTION FOLDING ALUMINUM FRAMED WALL SYSTEM

SECTION STILE AND RAIL WOOD DOORS

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

ADDENDUM #1. INVITATION FOR BIDS: NT North Macon Park Renovation of the Building

North Hanover Township School District North Hanover Township, New Jersey

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

SECTION (08800) - GLAZING

SECTION PREHUNG WOOD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION WALL AND DOOR PROTECTION

SECTION [ ] [08450] GLASS FACADES

SECTION GLAZING

4600 Series Specifications (Section 08520)

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Architectural Series Framing

Bovard Studio Inc. Section July 22, 2003 Page 1

This specification section is organized by placing information in three standard parts:

SECTION NEW WOOD WINDOWS. 1. Section Wood Window Restoration. 2. Section Painting.

Series B450 Guide Specification

SECTION DIRECTORIES

SECTION ALUMINUM WINDOWS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY

SECTION SPECIAL FUNCTION GLAZING

DIVISION VIII - DOORS AND WINDOWS

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

SECTION EXTERIOR SUN SHADES

SPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT

SUNY Cortland Renovations To Moffett Center Phase 2 Cortland, NY 13045

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION ALUMINUM WINDOWS

Section Aluminum Windows (2700 Model Specifications)

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION GLAZING PART 1 GENERAL 1.1 SUMMARY. A. Section includes: 1. Glass Types. 2. Glazing.

SECTION RESIDENTIAL CASEWORK

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Guide Specifications- Section

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system.

NOTE TO SPECIFIER: This section is based on the products of Solar Innovations, Inc., which is located at:

Omaha Public School Kellom Elementary School Renovations

Transcription:

SECTION 08 81 00 - DECORATIVE GLASS GLAZING PART 1 - GENERAL 1.1 SECTION INCLUDES A. Decorative specialty glass glazing for interior applications, including: GlasPro-BP as Manufactured by GlasPro www.glas-pro.com B. Glazing accessories. Specifier: If retaining this optional article, edit paragraphs to correspond to project scope. We recommend you retain references to sections specifying work that might otherwise be incorporated in work of this section. 1.2 RELATED SECTIONS A. Division 08 Section "Aluminum Frames" for interior glazed framing to receive glass and decorative glass. B. Division 08 Section "Aluminum-Framed Entries and Storefronts" for interior glazed framing to receive glass and decorative glass. C. Division 08 Section "All-Glass Entrances and Storefronts" for interior glazed framing to receive glass and decorative glass D. Division 08 Section "Glass Glazing" for glass and decorative glass incorporated in insulating glass units and for non-decorative monolithic glass. E. Division 08 Section "Mirrors" for silvered flat glass mirrors. F. Division 08 Section "Plastic Glazing" for acrylic and polycarbonate glazing. Specifier: If retaining this optional article, edit list of references after editing section; retain those references cited in the edited section. 1.3 REFERENCES A. American National Standards Institute (ANSI): 1. ANSI Z97.1 American National Standard for Safety Glazing Materials Used in Buildings, Safety Performance Specifications, and Methods of Test. B. ASTM International (ASTM): 1. ASTM C 1036 - Specification for Flat Glass. 2. ASTM C 1048 - Specification for Heat-Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated Glass. Page 1 of 6

3. ASTM C 1172 - Specification for Laminated Architectural Flat Glass. C. Code of Federal Regulations: 1. 16 CFR 1201 - Safety Standard for Architectural Glazing Materials. D. Glass Association of North America (GANA): 1. GANA Glazing Manual. 2. Laminated Glazing Reference Manual. 1.4 DEFINITIONS A. Manufacturers of Primary Glass: Firms that produce primary glass, as defined in referenced industry publications. B. Manufacturers/Fabricators of Glass Products: Firms that utilize primary glass in the production of glass products that may include heat treated glass, coated glass, and laminated glass. 1.5 SUBMITTALS A. Product Data: Manufacturer s data sheets for each glass product and glazing material. B. Samples: Minimum 6x6-inch square, for each type of glass product. C. Glazing Schedule: Prepare schedule using designations used on Drawings. D. Qualification Information: For Installer firm and Installer s manufacturer/fabricator-trained field supervisor. E. Warranties: Submit sample meeting warranties requirements of this Section. 1.6 QUALITY ASSURANCE A. Manufacturer/Source: Obtain each type of glass product from a single primary glass manufacturer and a single manufacturer/fabricator for each glass product type. B. Installer Qualifications: Experienced Installer with minimum of 5 successful completed projects of similar materials and scope, approved by glass product manufacturer/fabricator. C. Safety Glazing Products: Comply with size, glazing type, location, and testing requirements of 16 CFR 1201 for Category I and II glazing products, and requirements of authorities having jurisdiction. D. Glazing Industry Publications: Comply with glass product manufacturers recommendations and the following: 1. GANA Publications: GANA Laminated Division's "Laminated Glass Design Guide" and GANA's "Glazing Manual." Insert Editors Note Here E. Mockups: Mockup required Yes No Size Quantity Page 2 of 6

Other information F. Preinstallation Conference: Conduct conference at Project site in compliance with Division 01 requirements. 1.7 DELIVERY, STORAGE, AND HANDLING A. Protect glazing materials during shipping, handling, and storage to prevent breakage, scratching, damage to seals, or other visible damage. Deliver, unload, store, and erect glazing materials without exposing panels to damage from construction operations. 1.8 WARRANTY Insert Editors Note Here A. Provide a 5 year limited Warranty on Manufacturer's standard form, signed by manufacturer, agreeing to provide replacement glass for units that display delamination exceeding those allowed by ASTM C 1172 B. Warranty for Laminated Glass: Manufacturer/fabricator's standard form, signed by manufacturer/fabricator, agreeing to replace laminated-glass units that display edge separation, delamination, and blemishes exceeding those allowed by ASTM C 1172, within [five] years of date of manufacture. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Basis of Design: GlasPro-BP [, ENTER SPECIFIC DETAILS HERE ie SAMPLE#]: GlasPro BP is a high performance two component low VOC solvent borne two component Acrylic coating system designed specifically for painting glass. This is a hard and durable coating and is suitable for laminating. Bright clean exterior grade pigments with excellent weathering properties, Chemical resistance, scratch and abrasion resistance. The coating also offers low VOC (1 pound per gallon) and is environmentally friendly. A full range including Pantone and, most major manufacturers of industrial and retail paint. Custom colors & metallic are also available with no minimum quantity required. B. 1. GlasPro Inc. 562-946-7722 ph 562-946-2764 fax www.glas-pro.com 9401 Ann Street, Santa Fe Springs, CA 90670. Contact: McNeill Bishop 562-946-7722 2.2 GLASS PRODUCTS Specifier: Retain the applicable general glass product requirements cited below after editing the content of Part 2 of this section. Page 3 of 6

A. Glass Products, General: 1. Annealed Float Glass, General: ASTM C 1036, Type II, Class I (clear), Quality-[Q5]. 2. Starphire Float Glass: ASTM C 1036, Type I, Quality-[Q3], Class I, low-iron 3. Heat-Treated Float Glass, Heat-Strengthened: ASTM C 1048; Type I (transparent flat glass); Quality-Q3; Kind HS, of class and condition indicated. 4. Heat-Treated Float Glass, Fully Tempered: ASTM C 1048; Type I (transparent flat glass); Quality-Q3; Kind FT, of class and condition indicated, CPSC 16CFR-1201; ANSI Z 97.1, where safety glass is indicated. 5. Mirror Float Glass: Mirror Glazing Quality, ASTM C 1048. 6. Starphire Mirror Float Glass: Mirror Select Quality, ASTM C 1048, low-iron 7. Laminated Glass: ASTM C 1172, meeting Category II material testing requirements per 16 CFR 1201, with manufacturer s standard polyvinyl butyral or cured resin interlayer. 8. Coating Color: Clear. 2.3 GLAZING ACCESSORIES Specifier: Retain accessories below required for types of glazing installations required for project. GlasPro recommends the specifier consult experienced local glazing installers for recommended practices. A. Cleaners, Primers, and Sealers: Types recommended by sealant or gasket manufacturer. B. Glazing Gaskets, Wedges, Setting Blocks, Shims, and Tapes: Manufacturer's standard, as recommended for decorative glass type and application. C. Glazing Sealants: ASTM C 920, type recommended by glazing product manufacturer for application indicated. Specifier: Modify and complete "Hardware" article below for fittings for installation of decorative glass glazing that are not specified in related sections. We recommend specifying by identifying manufacturer's basis of design products. Sources include C. R. Laurence Co., Inc. www.crlaurence.com and CHMI Custom Hardware Manufacturing, Inc. www.chmi.com. 2.4 HARDWARE FOR INTERIOR GLASS INSTALLATION A. Hardware: 1. Clamps: Glass panel to ceiling; glass panel to wall; glass panel to floor; and glass panel to glass panel: <insert manufacturer and model>. 2. Panel Support Bars: <insert manufacturer and model>. 3. Shower Door Hinges: <insert manufacturer and model>. 4. Shower Door Pulls: <insert manufacturer and model>. 5. Shower Door Thresholds: <insert manufacturer and model>. 6. Shower Sliding Door Headers and Channel: <insert manufacturer and model>. 7. Stand-off Display System: <insert manufacturer and model>. 8. Continuous Top and Floor Track: <insert manufacturer and model>. B. Material and Finish: <Insert manufacturer's material and finish name and designation>. C. Fasteners: Match hardware base metal and finish. Page 4 of 6

2.5 FABRICATION OF GLAZING UNITS, GENERAL A. Fabricate decorative glass in dimensions required, with edge and face clearances, edge and surface conditions, and bite in accordance with decorative glazing manufacturer/fabricator s instructions and referenced glazing publications. B. Edge Finishing: Fabricate decorative glazing finished edges to produce smooth edges without chips or scratches, polished, and warp-free. Provide finished edges of type(s) shown on Drawings. C. Machining: Drill, notch, and cutout decorative glazing as indicated. Make cutouts smooth and uniform. PART 3 - EXECUTION 3.1 EXAMINATION A. Verify that glazing channels are clean and ready to accept glazing installation. Confirm that minimum required face and edge clearances will be maintained. Proceed with glazing once unsatisfactory conditions have been corrected. B. Examine glazing units prior to setting. Reject units that display edge or face damage that may impede performance of unit or that will be visible when installed. 3.2 GLAZING INSTALLATION A. General: Install glass and glazing materials in accordance with instructions of manufacturer/fabricator and requirements of GANA Glazing Manual. 1. Install setting blocks of size and in location required by glass manufacturer. Set blocks in bed of approved sealant. 2. Provide spacers for glass lites as recommended, based upon size of glass unit. 3. Comply with glass manufacturer s limits on edge pressures. 4. Provide edge blocking where recommended. 5. Install sealants in accordance with requirements of Division 07 Section "Joint Sealants." Specifier: Select glazing method or methods below that are applicable to project. Coordinate with Glazing Accessories selections in Part 2. B. Tape Glazing: Place tapes on fixed stops positioned to be flush or protrude slightly when compressed by glass. Install tapes continuously. Form butt joints at corners and where required, and seal tape joints with approved sealant. C. Gasket Glazing: Fabricate gaskets to fit openings exactly. Allow for stretching of gaskets during installation. 3.3 CLEANING AND PROTECTION A. Protect installed glass from damage. Attach streamers or warning tape to framing members, away from contact with glass. Remove nonpermanent labels. B. Protect glass from contact with contaminating substances during construction. Immediately clean glass exposed to contamination using methods recommended by glass manufacturer. Page 5 of 6

C. Clean all exposed glass surfaces using methods recommended by manufacturer. Remove glazing compounds from framing surfaces. D. Remove and replace broken or damaged glass. END OF SECTION 088100 Page 6 of 6