Data Quality Worth Sharing

Similar documents
AmpF STR NGM PCR Amplification Kit - Overview

AmpFlSTR Identifiler PCR Amplification Kit

First Look: Applied Biosystems NGM Detect PCR Amplification Kit

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Development and Validation of the 3500 Series Genetic Analyzer for Human Identification

Upgrading the Workflow: Enhancing Information Recovery from Forensic Evidence. The world leader in serving science

HID Validation: The 3500 Series Genetic Analyzers

Product Catalog 2012 AmplGen Ltd.

Artifacts Identified Post-Developmental Validation: AmpFLSTR Identifiler Plus PCR Amplification Kit

PowerPlex ESX & ESI Fast Systems

User Bulletin. Veriti 96-Well Thermal Cycler AmpFlSTR Kit Validation. Overview

Forensic News. FAS Corner April The Maximizing Data Quality Series Part 2: DNA Quantitation

GlobalFiler Kit Casework Test Site Results and Other Development Updates

GlobalFiler TM Extra Cycle Evaluation Report

Maximizing the Performance of Capillary Electrophoresis Systems The Maximizing Data Quality Series Part 4

Development of a Global STR Multiplex for Human Identification Analysis

Direct PCR Amplification of Blood Samples on Copan NUCLEIC-CARD TM Systems Using the AmpFlSTR Identifiler Direct PCR Amplification Kit

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

What is DNA? Deoxyribonucleic Acid The inherited genetic material that makes us what we are

DNA Typing for the Identification of Korean War Victims

The Evolution of Direct Amplification: From Sample to Result in 2 Hours*

AmpFlSTR NGM PCR Amplification Kit

The injection of the 28 and 29 PCR cycle data was performed at 3kV for 10 and 5 seconds.

AutoMate Express Forensic DNA Extraction System

Introducing: The AmpF STR NGM SElect Express Kit From Sample to Result in 2 Hours*

Genetic Identity. Steve Harris SPASH - Biotechnology

AmpFlSTR Identifiler Plus

DNA Typing Strategy for the Identification of Old Skeletal Remains

Uniparental disomy (UPD) analysis of chromosome 15

AmpFlSTR NGM SElect PCR Amplification Kit. User Guide

AmpFlSTR NGM PCR Amplification Kit. User s Guide

Development of a Global STR Multiplex for Human Identification Analysis

Developmental Validation of Amplicon Rx, a post-pcr Purification System

HID Real-Time PCR Analysis Software v1.1

Applied Biosystems 3130/3130xl Genetic Analyzers Using Data Collection Software v3.0

QIAGEN Validation Report

!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"!"

PowerSeq 46GY System Eases the transition to MPS for forensic laboratories

Introducing the Applied Biosystems TM Precision ID NGS System for Human Identification

Generating Forensic DNA Profiles

QIAGEN Validation Report

AmpFlSTR COfiler. PCR Amplification Kit. User Bulletin

FORENSIC GENETICS. DNA in the cell FORENSIC GENETICS PERSONAL IDENTIFICATION KINSHIP ANALYSIS FORENSIC GENETICS. Sources of biological evidence

Investigator Quantiplex HYres Kit

HID Real-Time PCR Analysis Software v1.3

PRODUCT BROCHURE PCR Systems. Veriti Thermal Cycler The Power of MORE

resdnaseq Quantitative DNA Kits

Thermo Scientific Equine Genotypes Panel 1.1

Thermo Scientific Bovine Genotypes Panel 2.2

Development of a Global STR Multiplex for Human Identification Analysis. Julio Mulero, Ph. D. R&D Group Human Identification, Life Technologies

Latest Tools for Human Identification

Internal Validation of the Promega PowerPlex Fusion System with the Applied Biosystems 3130xl Genetic Analyzer

Training on STR Typing Using Commercial Kits and ABI 310/3100

Same TaqMan Assay quality, new format

THUNDERBIRD SYBR qpcr Mix

PowerPlex ESX 17 Fast System for Use on the Applied Biosystems Genetic Analyzers

AmpFlSTR COfiler PCR Amplification Kit

PowerPlex ESI 17 Pro System

GenPlex HID Training Class I

Relative Fluorescent Quantitation on Capillary Electrophoresis Systems:

Applied Biosystems 7500 Fast Real-Time PCR System

Procedure for GeneMapper ID-X for Casework

PowerPlex. Y System Validation

PowerPlex ESI 16 Fast System for Use on the Applied Biosystems Genetic Analyzers


PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

PowerPlex ESX 16 System

Evaluation of the Autogen FlexSTAR automated DNA extractor, for suitability in routine diagnostic use

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Validation of a Multiplexed System for Quantification of Human DNA and Human Male DNA and Detection of PCR Inhibitors in Biological Samples

PowerPlex Fusion 6C System

Procedure for GeneMapper ID-X for Casework

PowerPlex ESI 16 System

QIAGEN Validation Report

Simplify your pathogen testing. Amplify your confidence.

Developmental validation of the Investigator Argus X-12 QS Kit

MightyAmp Genotyping Kit

PowerPlex ESI 16 System

RapidFinder TM Goat ID Kit

Report of Analyzing Short Tandem Repeats for Parentage Testing

TaqPath ProAmp Master Mixes

PowerPlex ESX 16 System

Protocol. Path-ID Multiplex One-Step RT-PCR Kit Protocol TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets

PowerPlex ESX 17 System

SYBR Green Realtime PCR Master Mix -Plus-

AmpliTaq 360 DNA Polymerase

Technical Focus. Direct PCR Amplification of Buccal Samples on the NUCLEIC-CARD COLOR With the AmpFlSTR Identifiler Direct PCR Amplification Kit

Simple, Complete Workflows for Gene Expression Analysis without RNA Purification

HID EVOlution Extraction System and HID EVOlution Combination System

STR DNA Data Analysis. Genetic Analysis

mirna QPCR Master Mix

Capillary Electrophoresis in DNA Analysis

Biology/DNA DNA Interpretation SOP. Biology/DNA Division

A comparative performance evaluation of illustra Ready-To-Go GenomiPhi V3 and illustra GenomiPhi V2 DNA amplification kits

Male/female DNA mixtures: a challenge for Y-STR analysis

STR Interpretation Guidelines

Thermo Scientific Extensor Long Range PCR Enzyme Mix

TaqMan Protein Assays

Y chromosomal STRs in forensics

Procedure for Casework DNA Interpretation

Transcription:

Product Bulletin Human Identification AmpFlSTR NGM and NGM SElect PCR Amplification Kits Next generation amplification chemistries including the 5 new loci from the expanded European Standard Set Enhanced sensitivity Unprecedented performance in the presence of inhibitors Increased ability to recover information from degraded samples Exceptional profile quality and clean baselines Maximized concordance with existing AmpFlSTR kit data Single amplification solutions for high quality results from both database and casework samples Streamlined workflow with reduced amplification time and pre-formulated reaction mix Utility for complex kinship investigations, disaster victim identification and missing person cases Data Quality Worth Sharing The AmpFlSTR NGM and NGM SElect PCR Amplification Kits represent a breakthrough in forensic DNA analysis technology. Leveraging recent advances in Applied Biosystems amplification chemistry development, these kits have been designed specifically to address the twin requirements stipulated by the European Network of Forensic Science Institutes (ENFSI) and European DNA Profiling Group (EDNAP) for chemistries that can deliver a powerful level of discrimination and unparalleled data quality to support cross-border data sharing initiatives. The NGM kit amplifies simultaneously the 11 SGM Plus kit loci (D3S1358, vwa, D16S539, D2S1338, D8S1179, D21S11, D18S51, D19S433, TH01, FGA and Amelogenin), together with the 5 additional loci approved by the European Union Council for the expansion of the European Standard Set (D10S1248, D22S1045, D2S441, D1S1656 and D12S391). The NGM SElect kit provides a parallel option that amplifies the same expanded set of loci together with the highly discriminating SE33 locus.

Configured for Success The NGM and NGM SElect kits take advantage of Applied Biosystems demonstrated expertise in utilizing 5-dye chemistry and mobility-modifier technology to maximize the number of loci contained within a multiplex, while minimizing the size of the amplicons. This addresses simultaneously the requirements for overall discrimination power on database samples and performance on challenging casework samples. Three of the new loci (D10S1248, D22S1045 and D2S441) occupy the shortest position in each of three dye colors, maximizing the potential for data recovery from even the most degraded and compromised samples. The two remaining new loci are located in the middle range of the multiplex, and add significantly to the discriminating power of the system as a whole. Figure 1. An example of an NGM Select kit profile generated from 1 ng of Control DNA 007. The NGM and NGM SElect kits have been optimized for a 1 ng input DNA concentration at 29 cycles of amplification to maximize signal and locus and profile balance. The NGM and NGM SElect kits share identical locus configurations with the exception of the inclusion of the SE33 locus in the NGM SElect kit. Using primer sequences redesigned from the SEfiler Plus kit but optimized to maximize concordance, the new SE33 amplicon occupies the largest position in the PET dye channel in the NGM SElect kit (Figure 2). Powerful Discrimination The combination of loci contained within the NGM and NGM SElect kits is designed to deliver the highest levels of discrimination compared to any previous AmpFlSTR kit (Table 1). By concentrating the majority of the loci below 200 base pairs, a greater number of alleles can be recovered from challenging samples. This means that even partial profiles from highly degraded samples can generate a level of discrimination very similar to a full SGM Plus kit profile. Additional discrimination power can also be achieved by using the MiniFiler kit as an adjunct to recover the longer loci that may fail to amplify in highly degraded samples. The powerful combination of the NGM or NGM SElect and MiniFiler kits enables maximum recovery of data from even the most degraded of samples. Figure 2. Configuration of the NGM SElect kit. Amplicon size ranges depicted indicate the run length on an Applied Biosystems capillary electrophoresis platform, including the effect of the mobility modifiers used to optimize the spacing between loci, and prevent overlap of alleles between adjacent markers. The SE33 locus is included in the largest position in the red dye channel, and the majority of the most discriminating loci have been concentrated in the low molecular weight region (less than 200 base pairs). The NGM kit shares the same configuration except for the absence of the SE33 locus.

Enhanced Sensitivity The proven utility of DNA in forensic investigations has driven laboratories to attempt the amplification of low amounts of DNA. The NGM and NGM SElect kits have been optimized for 29 cycles of PCR, which, when combined with the highly optimized reaction mix, maximizes the balance of the profile while enabling enhanced allele recovery at low input levels. The option of a 30 cycle amplification is also available for both kits. This provides laboratories with the flexibility to achieve optimum sensitivity and data quality depending on DNA input, while maintaining consistency for laboratories switching from a previous chemistry that uses up to 30 amplification cycles (e.g. the SEfiler Plus kit) (Figure 3). Kit Configuration African American US Caucasian Profiler Plus Kit 1.48 x 10-11 1.04 x 10-8 SGM Plus Kit 7.9 x 10-14 2.99 x 10-13 SEfiler Plus Kit 6.47 x 10-15 7.46 x 10-14 Identifiler Kit 1.31 x 10-18 5.01 x 10-18 MiniFiler Kit 6.52 x 10-11 8.21 x 10-11 NGM Kit 4.61 x 10-20 2.21 x 10-19 NGM SElect Kit 1.75 x 10-21 4.01 x 10-21 NGM /NGM SElect Kits < 200bp (+D21S11) 8.75 x 10-13 2.64 x 10-12 Table 1. Comparison of Pi values of different AmpFl STR kit and locus configurations. The combination of loci in the NGM and NGM SElect kits deliver the highest levels of discrimination (shown in yellow and green respectively). Highly degraded samples that yield results only for loci <200bp in length provide a level of discrimination (shown in blue) close to that possible from a full SGM Plus kit profile. Figure 3. An illustration of the difference in peak height generated for 125 pg of control DNA 007 amplified by the NGM SElect kit using 29 and 30 cycles. Data is shown broken out by dye label. Increases in peak height of 30-50% may be expected when using 30 cycles therefore offscale data may be visible if using input amounts of 1 ng or greater. Laboratories wishing to implement a 30 cycle protocol should determine the optimum input DNA concentration appropriate for their anticipated sample types.

Maximum Performance on Inhibited Samples Building on recent AmpFlSTR kit developments such as the MiniFiler kit, the NGM and NGM SElect kits represent further major advances in amplification chemistry formulation. Containing our most powerful reaction mix to date, these kits are capable of recovering data from samples containing unprecedented levels of inhibitors (Figure 4). This increases the number of samples yielding a full profile at the first attempt. Easy to Implement, Easy to Use The NGM and NGM SElect kits offer laboratories a single kit solution that delivers high quality results for both database and casework samples. The workflow is very similar to other AmpFlSTR kits, enabling forensic laboratories to streamline validation and implementation. The enzyme is now contained within the master mix, simplifying reaction set-up, and cycling times have been shortened by approximately one hour, allowing laboratories to achieve higher quality results more quickly. In addition, to help ensure compatibility with both manual and automated systems, the NGM and NGM SElect kits are available in two package sizes, the standard 200 reaction kit and a larger 1000 reaction kit. The larger package includes larger bottles to facilitate use on liquid handling platforms. Figure 4. An illustration of the increased capability of the NGM and NGM SElect kits to amplify samples in the presence of very high levels of PCR inhibitors. In this example, the NGM SElect kit is compared to the SGM Plus and SEfiler Plus kits. The SGM Plus kit was amplified for 28 cycles and the SEfiler Plus and NGM SElect kits were amplified for 30 cycles. When challenged with significant amounts of humic acid, the next generation kits are able to obtain full profiles at levels of inhibition impossible to amplify successfully with any previous AmpFlSTR kit (NGM kit data not shown). Exceptional Data Quality The NGM and NGM SElect kits have been developed according to Applied Biosystems stringent performance standards to provide gold standard data quality. Optimized as part of an integrated reagent, instrumentation, and software system, both kits offer maximum performance and efficiency on industrystandard capillary electrophoresis systems. A 1 ng input DNA recommendation maximizes heterozygote peak height balance within each profile, which allows laboratories to take full advantage of expert system analysis of database samples while increasing the level of confidence with which casework data can be interpreted. Analysis of casework samples has been further enhanced through improvements in Applied Biosystems primer manufacturing techniques, which minimize the presence of dye-related artifacts that can interfere with data interpretation (Figure 5). Compatibility with Existing Databases Any new multiplex development must take into consideration the volume of data already stored on national databases with which any new data will be compared. Within Europe alone, over 6 million DNA profiles from both suspects and convicted offenders are stored on national databases, and much of this data has been generated using existing AmpFlSTR kits such as the SGM Plus, Identifiler and SEfiler Plus kits. To facilitate comparisons with this valuable data repository, the NGM and NGM SElect kits maintain identical primer sequences for STR loci common to other AmpFlSTR kits, facilitating maximum concordance and simplifying data comparison. For the SE33 locus, even though the primers have been re-engineered to relocate the amplicon within the multiplex, the new primer sequences have been tested thoroughly to help ensure maximized concordance with existing data generated using the SEfiler Plus kit.

Figure 5. A comparison of negative control reactions for four different AmpFlSTR kits. The improved primer manufacturing process introduced for the NGM and NGM SElect kits results in significantly cleaner baselines than for previous AmpFlSTR kits. Utility for Specialized Applications The outstanding discrimination and robustness delivered by the NGM and NGM SElect kits provide additional utility for specialized human identification applications including: Complex paternity/kinship cases Missing persons cases Disaster victim identification The Power of Collaboration The capabilities of the new AmpFlSTR NGM and NGM SElect kits are a powerful testament to the benefits of collaboration. Since the initial publication of the recommendations on new loci in 2005, Applied Biosystems has worked closely with laboratories within ENSFI and EDNAP to ensure delivery of chemistries with the capability to meet the requirements of the 21st century forensic laboratory. Since the establishment of an initial prototype system in 2007, Applied Biosystems has partnered with the European forensic community to test and solicit feedback on the performance of the chemistry. This close relationship with operational forensic laboratories has enabled a more comprehensive assessment of the chemistry on a much wider range of samples than would have been possible without their assistance. Complete Validated Solution Life Technologies offers a complete solution to help meet the needs of the Human Identification community. Our integrated Applied Biosystems HID workflow includes DNA extraction and quantification kits, a range of AmpFlSTR STR kits, instrumentation, software, and. consumables. The NGM and NGM SElect kits are part of the most comprehensively validated system available for Human Identification. Experience Matters Life Technologies is the only company in the world that designs and validates reagents, instruments, and data analysis software together as an integrated system for forensic DNA testing. Technical Service Scientists and Field Application Specialists are available to answer your technical questions, review data, and make recommendations on how to perform assays and troubleshoot results. Our team of forensic experts is also available to provide in-depth training and can support the planning and efficient execution of internal validation projects in your laboratory. All of these resources help ensure success when using Applied Biosystems Human Identification solutions in your laboratory.

KIT COMPONENTS AmpFlSTR NGM PCR Amplification Kit AmpFlSTR NGM Master Mix (contains enzyme) AmpFlSTR NGM Primer Set AmpFlSTR Control DNA 007 AmpFlSTR NGM Allelic Ladder AmpFlSTR NGM SElect PCR Amplification Kit AmpFlSTR NGM SElect Master Mix (contains enzyme) AmpFlSTR NGM SElect Primer Set AmpFlSTR Control DNA 007 AmpFlSTR NGM SElect Allelic Ladder ORDERING INFORMATION Description Quantity P/N AmpFlSTR NGM PCR Amplification Kit 200 tests, 25 μl/test 4415020 AmpFlSTR NGM PCR Amplification Kit 1000 tests, 25 μl/test 4415021 AmpFlSTR NGM PCR Amplification Kit User Guide 1 manual 4425511 GeneScan 500 LIZ Size Standard 800 reactions 4322682 AmpFlSTR NGM SElect PCR Amplification Kit 200 tests 4457889 AmpFlSTR NGM SElect PCR Amplification Kit 1000 tests 4457890 AmpFlSTR NGM SElect PCR Amplification Kit User Guide 1 manual 4458841 GeneScan 600 LIZ Size Standard v2.0 800 reactions 4408399 Matrix Standard Set DS-33 (6-FAM, VIC, NED, 1 tube with 5 dyes 4345833 PET, LIZ dyes) for use with 3100, 3100-Avant, 3130, 3130xl and 3500 systems Matrix Standard Set DS-33 (6-FAM, VIC, NED, 1 tube with 5 dyes 4318159 PET, LIZ dyes), for use with 310 systems Validation Support and Training for AmpFlSTR Kit Implementation Contact Sales Representative For Research, Forensic or Paternity Use Only. Not intended for any animal or human therapeutic or diagnostic use. NOTICE TO PURCHASER: LIMITED LICENSE Use of this product is covered by one or more US patent claims and patent claims outside the US. The purchase of this product includes a limited, non-transferable immunity from suit under the foregoing patent claims for using only this amount of product solely in forensic and paternity testing, including reporting results of purchaser s activities for a fee or other commercial consideration, and also for the purchaser s own internal research. No right under any other patent claim is conveyed expressly, by implication, or by estoppel. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Life Technologies, 850 Lincoln Centre Drive, Foster City, California 94404, USA. Not for re-sale. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners 2010, 2011 Life Technologies Corporation. All rights reserved. Printed in the USA. 04/2011 Publication CO15724 During the development of products for forensic DNA analysis, Life Technologies performs developmental validation studies. However, it is the responsibility of customer to perform its own analysis and appropriate internal validation studies to ensure that the products and services it obtains from Life Technologies satisfy or will satisfy the applicable guidelines used by the forensic community and are fit for the customer s human identification applications. Headquarters 5791 Van Allen Way Carlsbad, CA 92008 USA Phone 760.123.4567 Toll Free 800.123.4567 www.lifetechnologies.com International Sales For our office locations please call the division headquarters or refer to our Web site at http://www.lifetechnologies.com/about-life-technologies/contact-us.html