Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

Similar documents
Your Partner for Gas Monitoring Solutions OPSIS Gas Monitoring Systems

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

CANADA UNISEARCH founded in 1980

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

FTIR Analyser BROCHURE

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

PRODUCT CONFORMITY CERTIFICATE

Continuous Emissions Monitoring in Support of the Cement MACT

New Requirements for the Measurement of Ammonia Emissions

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

Fully Extractive Vs. Dilution Extractive CEMS

EN14181 Stationary Source Emissions Quality Assurance of Automated Measuring Systems

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems

Comparison Continuous Emission Monitoring Techniques

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

PRODUCT CONFORMITY CERTIFICATE

A Higher Standard of Monitoring Systems & Customer Service

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

The development of instrumentation for application to carbon capture and storage measurements

PRODUCT CONFORMITY CERTIFICATE

CERTIFICATE of Product Conformity (QAL1 )

PRODUCT CONFORMITY CERTIFICATE

Fpollutant-free zero air for analytical

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

PRODUCT CONFORMITY CERTIFICATE

Author: Donald Pretty, Project Manager, Presenter: John Downs, Environmental Manager, B&W PGG, KVB-Enertec Products January 29, 2015

Guido Baum Dr. Peter Wilbring

Online data sheet MCS300P HW PROCESS SOLUTIONS

PRODUCT CONFORMITY CERTIFICATE

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Standard Continuous Emissions Monitoring System (CEMS)

Online Gas Analyzer / Monitor

Introduction and Agenda

Advanced Spectroscopic Solutions for Fuel Cell Hydrogen Analysis

HILASE - QUALITY CONTROL INSTRUMENT

Process Analytics Using Quantum Cascade Laser

Monitoring cement plant stack emissions using FTIR

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

PRODUCT CONFORMITY CERTIFICATE

Regulatory position paper on sulphur dioxide monitoring, comparing portable-instrumental techniques with manual methods

EPA vs. EN standards

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

PRODUCT CONFORMITY CERTIFICATE

CEM Istanbul, 14 th May 2014

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

A COMPARISON OF GAS ANALYSIS TECHNOLOGIES AVAILABLE FOR EFFICIENT AND SAFE COMBUSTION IN CONTROL FIRED HEATERS

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes. a technical solution to meet every need

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

QAL3 methods for different measurement principles from the point of view of AMS manufacturers, test houses and plant operators

INDUSTRIAL EMISSION MONITORING: METHODS AND EMERGING TECHNIQUES

Online data sheet MCS100E HW-C CEMS SOLUTIONS

PRODUCT CONFORMITY CERTIFICATE

CONFIRMATION of Product Conformity (QAL1)

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW

Maintaining Continuous Emissions Monitoring Systems To Achieve High Reliability. a technical solution to meet every need

Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC

PRELIMINARY BROCHURE

ACF5000 The new benchmark in FTIR CEMS Key features pocket guide

Monitoring Quick Guide 3

Process Analytics. Reliability and efficiency in continuous gas analysis. A strong family for your success. usa.siemens.com/cga

Application Note. Hydrogen Purity Analysis by FTIR PROBLEM BACKGROUND

An Overview of Mercury Monitoring Options

Continuous Mercury Monitoring at Cement Plant

: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation

Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

ONLINE FLUE GAS ANALYZERS

Advances in NOx Compliance Testing with Portable Electrochemical Analyzers

Sampling Technology for Extractive CEMS & Maintenance Issues of CEMS Sanjeev Rai Perma Pure Aug 9, 2016

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators

Single-Use Sensors. TruFluor and TruTorr Excellence in bio-processing measurement

ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

MLT 2 Multi-Component Gas Analyzer

Ambient Air Quality Monitoring

Air Quality (VOC) Transmitters for Duct Mounting. Features. Ordering QDT QDT S QDT D

Internet Publication Plan. For the proposed public website for Metro Vancouver s Waste-to- Energy Facility

Precision Is Always A Question Of Technology. Proven and Innovative Solutions for Modern Process Analytics. siemens.com/cga

CEM400. Online Gas Analyser. Specialist Of UV Spectroscopy

DR1000 Flying Laboratory, Drone Environmental Monitoring

Process Optimization & Plant Safety

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

A TRULY INTEGRATED CONTINUOUS EMISSION MONITORING SYSTEM (CEMS) OPTIMIZED FOR THE WASTE-TO-ENERGY (WTE) APPLICATIONS

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

Transcription:

Continous Emission Monitoring: Methods, Regulations and QA/QC Anders Arvidsson, Opsis AB, Sweden

OPSIS? OPSIS is a Swedish company which develops, manufactures and supplies total solutions for Ambient Air Quality Monitoring, Stack Emission Monitoring and software tools for Air Quality Management. Founded 1985 OPSIS is represented world-wide, with internationally accepted and approved products. ISO 17025 Accredited Calibration laboratory

AIR QUALITY MONITORING Street Mobile City Background Industries Airports

CONTINUOUS EMISSION MONITORING Power Waste Incineration Cement Steel plants Chemical Industries Ship Emissions Sulfuric Acid plants

CEM PRODUCTS Methods In Situ Dilution extractive Wet-hot extractive Dry extractive Techniques DOAS FTIR IR absorption UV absorption Chemiluminescence UV-fluorescence Gas cell and more.

A TYPICAL EXTRACTIVE CEMS

EXTRACTIVE METHODS Dilution extractive Wet-hot extractive + Ambient type analysers can be used + Sample is dry and clean + Low initial cost - Requires correct dilution - Not suitable for monitoring low concentrations + Multigas analysers can be used - Expensive - Hot sample requires advanced heating systems - Sensitive for power failures and high dust loads Dry extractive + Low cost NDIR analysers can be used - Not suitable with high dust loads - Water removal changes the sample condition

IN-SITU CEMS Cross Stack Probe Type +Non-contact measurements +No sample system +Cross stack = representative measurements +Analyser can be installed in cool and dry environment -Requires extended platforms +No sample system +Partly non-contact measurements -Probe exposed for flue gas -Analyser exposed for rain,humidity, sun radiation etc

IN-SITU EXTRACTIVE? Fast Loop Solution, a combination of In-Situ and Extractive 120 mm Inlet (after fan) 2" Insulated Pipe (or tube) +Non-contact measurements +No Sample filters, No heated sample lines + Easy access to CEM system sample lines -Some additional installation costs Fan Option: Calibration Zero Air Insulated Measure Loop (Opsis part) AC see drw. D302792 Outlet (before fan) Option: External fan Drainage

FASTLOOP INSTALLATION

WHY CONTINOUS EMISSION MONITORING? Regulations (Examples) o E.U 2001/80/EC (LCPD) ( NOx, SO2, CO ) o US 40 CFR Part 60 / 75 o Emissions trading programs, for example: o European emission trading scheme (greenhouse gases) o Acid rain program (U.S) o Emission Fees and Taxes o Local Regulations in Thailand? Cost saving, process applications ( DeSOx,DeNOx, Scrubbers, combustion control)

APPLICATIONS Emission Monitoring(NOx,SO2,CO, CO2,HCL,HF,Hg ) To comply with Environmental Regulations Raw gas measurements ( CO, NOx, NH3, HCl, H2O ) For combustion control and feedback Process control ( NO,NH3,SO2, HCL,H2O) For cost effective flue gas treatment EP/FF DeNOx Scrubber

EUROPEAN REGULATION 2001-80-EC ( and others) -Which Industries, Which pollutants and Limit Values EN14181- Quality Assurance of CEM systems EN15267- type approval /eqvivalent methods

EN 14181 QAL1 - Each CEM system must have certificate from accredited body (TÜV etc) showing if the CEM system meets the required performance specifications QAL2 Field comparison with accredited testing laboratory/reference methods ( at installation and then every 5 years) QAL3- The maintenance requirements and frequency AST same as QAL2, but at a smaller scale and every 12 months

HOW TO BUY A CEM SYSTEM THAT MEETS YOUR REQUIREMENTS (CAN YOU TRUST THE SALES PERSON? )

TÜV CERTIFICATIONS WEBPAGE www.qal1.de/en Excellent Tool for comparing analyser performance!

LIST OF CERTIFIED MANUFACTURERS

LIST OF GASES

COMPARISON BASED ON TÜV QAL1 Based on Total Uncertainty Parameter Measurement Level OPSIS SICK Gasmet ABB Limit SO 2 50 mg/m 3 4.9% 10.5% 9.4% 10.0% 15% NO 2 20 mg/m 3 4.7% 37.1% 57.0% 15% NO 131 mg/m 3 2.8% 9.5% 6.5% 8.2% 15% NH 3 10 mg/m 3 5.0% 6.4% 9.6% 30% CO 50 mg/m 3 5.4% 8.7% 6.0% 9.8% 7.5% H 2 O 30% Vol. 4.0% 5.7% 6.2% 4.2% 7.5% HCl 10 mg/m 3 6.2% 12.2% 12.0% 11.8% 30% HF 1 mg/m 3 18.4% 30.3% 18.4% 63.0% 30% O 2 25% Vol. 4.8% 2.8% 2.4% 2.4% 7.5% Hg tot 30 mg/m 3 7.8% 2.3% 30% CH 4 20 mg/m 3 5.4% 15.6% 22.5% CO 2 30% Vol. 2.3% 6.7% 5.0% 7.5%

THE IMPORTANCE OF GOOD PERFORMANCE Good performance is important when money is involved. CO 2 measurements for tax reasons. NO and NO 2 measurements for NO x limits and NO x tax. SO 2 measurements for ship regulation. Good performance is important in order to pass QAL2/AST or RATA New regulation going towards lower emissions, requires analysers with better performance

QAL 1 CERTIFICATES

CALIBRATION INTERVAL CONFIRMED BY TÜV Opsis is the only Manufacturer in the world that has got 12 months calibration interval verified by German TÜV!

OPSIS DOAS TECHNIQUE Differential Optical Absorption Spectroscopy

OPSIS CEM SOLUTIONS Cross-Stack In-Situ (~85%) Fast Loop In-Situ (~15%) Hot/Wet and Dilution Extractive (~5%)

UV DOAS DOAS= Differential Optical Absorption Spectroscopy) For gas compounds such as : Nitrogen Oxides (NO, NO 2 ) Ammonia Sulfur Dioxide Naphtalene Benzene Toluene Xylenes Mercury Chlorine and more

IR DOAS DOAS= Differential Optical Absorption Spectroscopy) For gas compounds such as : Hydrogen Chloride Carbon Monoxide Carbon Dioxide Hydrogen Fluoride Moisture Bromine Iodine Methane Propane Ethane Hydrogen Sulfide Total Hydrocarbons and more

TDL TDL = Tuneable Diode Laser) For gas compounds such as : Hydrogen Chloride Carbon Monoxide Carbon Dioxide Hydrogen Fluoride Moisture Ammonia Oxygen Methane Hydrogen Sulfide and more

EMITTER AND RECEIVER Purge air Purge air Light source/ Emitter Flue gas Receiever Fibre optic cable to analyser

MULTI PATH APPLICATIONS Reduced cost Reduced maintenance Reduced calibrations Suitable for DeSOx,DeNox

INSTALLATION OVERVIEW DOAS Emitter DOAS Receiver

INSTALLATION OVERVIEW DOAS Analysers Analyser shelter

SIGNAL/COMMUNICATION Plant DSC/PLC RS232, Alternative 4 ( Cactus, ABDH, ModBus, Siemens 3964R, Comli) Enviman ComVisioner/Reporter AR600/650 RS232 or LAN LAN RS232 RS232, Alternative 1 RS232, Alternative 2 +3 +/- 15VDC CM IM001 OM001 DM016 110/220-240 VAC 0-10VDC 0/4-20 ma 0/4-20mA Status I/O Ioman Signal Handling System ( Optional)

CALIBRATIONS The DOAS system has very low zero/span drift and is recently approved/certified by German TÜV for a calibration interval of 12 months DOAS calibration kit does not require gas calibrators or dilutors, instead, calibration cells with various length are used together with standard gas

AUTOMATIC INTERNAL QA/QC A number of internal system checks and self calibrations are done automatically, checking wavelength precison, spectral errors, etc, and will provide status /alarms if out of range. A number of automatic data validation functions/filters are available in the analyser for light levels, standard deviations and signal/noise ratio

DOAS SYSTEM MAINTENANCE Check light levels on daily basis ( automatically with status signals/alarms) Replace lamp every 6 months Calibration yearly (or according to local requirements) Replace HeNe laser in IR DOAS every 24-36 months Replace sweep wheel bearing in UV-DOAs Every 5 years

HIGHLY QUALIFIED SUPPORT TEAMS

LOCAL SUPPORT IN THAILAND Sithiphorn Associates, Thailand, has been Opsis Distributor for more than 25 years! Sithiphorn has many experienced engineers that has been trained in Sweden Sithiphorn can provide best possible support, maintenance contracts, calibration services etc

ENVIMAN SOFTWARE Includes about 30 software modules to be used for... Data acquisition Data presentation and reports Emission inventory setup Dispersion modelling

ENVIMAN DATA MANAGEMENT SOLUTION CEMS Pollution Data from industries Input from any type of station/sourc e Server for the data processing & distribution DENR /EMB Users Output/Reports Presentation, reports and statistical analysis of monitoring data Monitored Air Quality Data Emission simulations Met. Data Digital Map Data /(GIS) LAN/WAN or Internet Dispersion calculations

CREATE A DATABASE OF POLLUTION SOURCES

DISPERSION MODELLING

NOWCASTING Real time dispersion model Requires real time CEM data, met data and a dispersion model. Validation by installed AQM station

WORK FROM ANYWHERE Work remotely over internet / LAN using remote desktop connection Work on private or global projects Using Microsoft Terminal Server solution

www.opsis.se