Permanent Buried Reference Electrodes: Technical Note on Significant Inaccuracies and Medium Term Trials

Similar documents
Brian S. Wyatt Eur Ing, BSc, C Eng, MIM, FICorr, FIHT, FCS. Corrosion Control

Estimation of Corrosion Protection Condition on Buried Steel Pipeline under Cathodic Protection with IR-free Probe

Rawabi Corrosion Technology

COMPANY PROFILE 2010

Corrosion is defined in different ways, but the usual interpretation of the term is an attack on a metallic material by reaction with its

Pipeline Integrity: Combining Coating Integrity and Cathodic Protection Surveys

Corrosion Control and Cathodic Protection Data Sheet

CATHODIC PROTECTION FOR SOIL STEEL BRIDGES 1

Veriforce TG CCT 407OP. Training Guide

Part 1: On-land pipelines

Delay for steel coupons potential measurement after OFF disconnection Introduction

DESIGN OF IMPRESSED CURRENT CATHODIC PROTECTION SYSTEMS

TEST CORROSION AND CATHODIC PROTECTION

APPLICATION NOTE 6. Use of Decouplers for AC Voltage Mitigation. PART 2: DESIGN CONSIDERATIONS

MODELING OF IMPRESSED CURRENT CATHODIC PROTECTION ANODE ARRANGEMENTS FOR STORAGE TANK BOTTOMS

Dates of Innovation Development: January, 2014 to July 2015 Web site: Summary Description: Cathodic Protection

CATHODIC PROTECTION ON SINTAJOINT PIPELINES

CORROSION ENGINEERING AND CATHODIC PROTECTION

Cathodic Protection Influencing Factors and Monitoring

Influence of resistivity on current and potential distribution of cathodic protection systems for steel framed masonry structures

Standard Recommended Practice. The Use of Coupons for Cathodic Protection Monitoring Applications

Corrosion Protection

AC Corrosion - The Unanticipated Problem

Mears Group, Inc. Integrity Assessment for Non-Piggable Pipelines By Jim Walton

oday s operators continue to face challenges in gathering quality cathodic protection (CP) data. Most operators employ indirect methods such as

What s Next Establishing Reassessment Intervals

Dynamic Stray Current Interference Testing And Mitigation Design For A 90-Inch Water Main

Evaluation of Key Performance Indicators (KPI s) in Crude Oil Transmission Pipeline

ABSTRACT EXECUTIVE SUMMARY

Cathodic Protection Regulatory Requirements

Refining Corrosion Technologist NACE-RCT-001

The Advancement of Direct Assessment Methodologies for Difficult-to-Assess Piping

Review of Cathodic Protection Systems for Concrete Structures in Australia Lessons Learnt and Future Directions

Reference Electrode for Monitoring Cathodic Protection Potential

Refining Corrosion Technologist NACE-RCT-001

a: potential difference before direct current is applied b: potential difference after the application of current

CATHODIC PROTECTION SYSTEM

ILNAS-EN 13509:2003. Cathodic protection measurement techniques. Messverfahren für den kathodischen Korrosionsschutz

Y.B. Cho. K.W. Park, K.S. Jeon, H.S. Song, D.S. Won, S.M. Lee and Y.T. Kho

Refining Corrosion Technologist NACE-RCT-001

Corrosion Resistance of Aluminum

CATHODIC PROTECTION SPECIFICATION

Application of Computational Modeling to Predict the Effectiveness of CP on a PCCP Transmission Pipeline

Corrosion Protection

SPL -ANODE SERIES. Impressed Current Linear Anodes PRODUCT DATA SHEET. Contact a MATCOR corrosion expert

Refining Corrosion Technologist NACE-RCT-001

Introduction to Cathodic Protection

DEVELOPMENT OF A SUCCESSFUL UNTETHERED LEAK DETECTION AND PIPE WALL CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPELINES

TABLE OF CONTENT

CATHODIC PROTECTION OF STAINLESS STEEL 316L ROTATING SCREENS ON SEAWATER INTAKE STRUCTURES

INSTITUTE OF INTEGRATED ELECTRICAL ENGINEERS OF THE PHILIPPINES, INC. (IIEE-ERCSA) First IIEE Accredited Foreign Chapter (Charter

Galvanic Anodes Period 3 Intermediate Corrosion Course 2017

2) Galvanic or Two-Metal corrosion

Standard Test Method. Measurement Techniques Related to Criteria for Cathodic Protection on Underground or Submerged Metallic Piping Systems

The DuoGuard Hybrid Anode Range Installation Guidelines

SERVICES. NDT Inspection Non Destructive Testing. Installation of Cathodic Protection System

WHAT ABOUT STRAY CURRENTS WITH STEEL FIBRE REINFORCED CONCRETE

CORROSION ENVIRONMENT PROBE INTERNAL CHECK F E B B C = MEASURE C D = REFERENCE D E = CHECK AC DRIVE CARBON STEEL DUCTILE IRON

The Next Generation Of Network Management And Leakage Detection Systems

Singapore s Experience of Water Loss Reduction. Lai Kah Cheong Chief Engineer 7 Sep 17

Measuring the Effect of Cathodic Protection on the Performance of Thermally Sprayed Aluminium Coatings at Elevated Temperature

DESIGNING FOR A LOW RESISTANCE EARTH INTERFACE (GROUNDING)

Senior Vice. President. CTO and. Category: Cathodic. Protection. Dates of. Web site: SOFCs are. site. gas can be. SOFCs have

Catasrophic Failure of Aging Underground Pipelines Is Inevitable Under Certain Corrosion Conditions

STANDARDIZED PIPELINE RISK COMPARISON AND PREDICTION

District Heating Network Best Practices. International District Cooling & Heating Conference

TESTING ON CATHODIC PROTECTION COUPONS FOR THE 100 MV CRITERION

Non-irrigated Irrigated Difference. Early 27.1 bushels per acre 33.8 bushels per acre 6.7 bushels per acre

Condensed Study Guide

AC induced corrosion on onshore pipelines, a case history.

CORROSION CONTROL OF ABOVE GROUND STORAGE TANK BOTTOM STEEL PLATES USING ALUMINUM MESH ANODE WITH NEWLY DEVELOPED BACKFILL

DEVELOPMENT OF A SUCCESSFUL INTERNAL LEAK DETECTION AND PIPELINE CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPES.

CATHODIC PROTECTION OF A MULTI-STOREY BUILDING, METHOD OF PROJECT DELIVERY AND LONG-TERM MAINTENANCE

Process Electrodes and Probes

CONDUCTING CLOSE INTERVAL POTENTIAL SURVEYS

Electrochemical Die-Sinking (ECM) in Practice

IOM3 Underground Seminar. Health and Safety Laboratory Buxton. 27 May 2010

SERVICE LIFE EVALUATION OF CORRUGATED STEEL PIPE

5. How to Select and Use the Right Temperature Sensor

IonX Portable Electrodes

FELIX JARIA Soil Moisture measurement

Technical Information Memosens CPS31D and Ceratex CPS31

Standard Test Method. Measurement Techniques Related to Criteria for Cathodic Protection on Underground or Submerged Metallic Piping Systems

What is ph? ph is the measurement of the Hydrogen Ion concentration in a particular solution. Indicates the Acidity or Alkalinity of a solution.

Risk Mitigation Plans Budgeting, Planning and Forecasting

Title of Innovation: Corrosion Protection for Pipeline Microtunneling. Brief Summary: Category: Design

Ground Related Risk to Transportation Infrastructure

NEW TRENCHING TECHNOLOGIES & SERVICES FOR PIPELINES Experience in Chile

F U C H S L U B R I C A N T S C O.

INTRODUCTION. *Product specifications are subject to change without notice.

中国石油集团石油管工程技术研究院 C N P C T U B U L A R G O O D S R E S E A R C H I N S T I T U T E

MANAGEMENT OF CATHODIC PROTECTION SYSTEMS IN MARINE ENVIRONMENTS

Corrosion Basics. About this article

Corrosion Control using Cathodic Protection for Prefabricated Buried Steel Pump Stations1

CATHODIC PROTECTION AN OVERVIEW

Part 192 Corrosion Enforcement Guidance

Corrosion Investigation for Contra Costa Community College District - Brentwood Campus

Corrosion in Reinforced Concrete

sites under the deposit become anode and the lead to pitting. Hence, a good design should not allow the built up of impurities on surface

OFFSHORE CATHODIC PROTECTION 101: WHAT IS IT AND HOW DOES IT WORK? Dick Baxter & Jim Britton

Transcription:

Permanent Buried Reference Electrodes: Technical Note on Significant Inaccuracies and Medium Term Trials Brian S Wyatt Eur Ing, BSc (Hons), CEng, MIMMM, FICorr, FCS Corrosion Control, 3 Ivy Court, Acton Trussell, Staffordshire ST17 0SN, UK Introduction In 2012, as part of an extensive upgrading of a cathodic protection system for an approximately 90km buried oil pipeline in the UK, some 50 No. permanent Cu/CuSO 4 sat permanent reference electrodes were installed by limited dig, primarily jetting, techniques along the pipeline. The pipeline is subject to stray dc current interaction from a mainline electrified railway system. The pipeline also has some threats of ac corrosion from high voltage overhead transmission systems which parallel and cross the pipeline. Coupons (1cm 2 ) were installed adjacent to each of these permanent reference electrodes for both instant OFF dc potential measurements and ac measurements. Both electrodes and coupons were installed adjacent to and at pipe invert level. In order to provide more rigour and flexibility in the testing regime, upvc pipes were also installed at each location to enable portable electrodes or coupons to be introduced to pipe invert level between the fixed electrodes and coupons. Thus, approximately 1.5m to one side of the pipeline, were installed in a line with approximately 500mm between each item, a reference electrode, an open ended upvc pipe and a coupon. Page 1 of 6

The permanent Cu/CuSO 4 reference electrodes were from a reputable manufacturer and stated as having been developed for direct burial with a micro porous tubular body and a solid matrix electrolyte preventing leaching of sulphates from the electrode; they had a claimed life of 25 years and stability of +/-5mV. Within only a few months after installation, these electrodes were producing unexpected pipe/soil/electrode potential data. A full survey was undertaken to compare their electrode potentials with those of clean, calibrated, portable Cu/CuSO 4 sat reference electrodes introduced down the upvc tube (within 500mm of the permanent electrodes at the same distance from the pipe and at the same depth as the permanent electrode). Many electrodes were presenting potentials >30mV from their theoretical potential and some >100mV. Within months the greatest error was >200mV. At the last full assessment in week 11 of 2013 the following errors were determined by measurement between the permanent electrodes and a clean calibrated Cu/CuSO 4 portable electrode placed proximately (within 500mm at the same depth) to the permanent electrode: Table 1: Errors of Permanent Electrodes installed in 2012 Measurements in Week 11 of 2013 All electrodes of common type Cu/CuSO 4 solid electrolyte Location Electrode Error mv Location Electrode Error mv TP1-29 TP50-49 TP2-67 TP53-60 TP4-63 TP56A +29 TP6-1 TP61-61 TP7-14 TP62-52 TP9-187 TP64-53 TP10-47 TP67-39 TP12-199 TP68-41 TP12A -153 TP70-39 TP15-6 TP72-55 TP17-66 TP73 +129 TP18-224 TP74-102 TP20-84 TP76-110 TP22-78 TP78-113 TP26-67 TP 81A -46 TP28-53 TP83-57 TP30-66 TP85B -62 TP31-20 TP89-38 TP33-66 TP92-39 TP34-195 TP94-59 TP36 MISSED TP97-164 TP38-51 TP101-187 TP40-126 TP102-171 TP41-51 TP104-69 TP43-22 TP106-76 TP45-111 TP109-97 TP45A -13 TP111-202 TP48-191 TP113-47 TP115-17 Page 2 of 6

It is clear that these permanent electrodes can not be classed as reference electrodes. It would be reasonable to expect competent reference electrodes to be accurate to +/- 5mV before installation and say +/- 10mV after installation. The ground conditions along the pipeline were not prone to known contaminants, such as chlorides, that are known to contaminate Cu/CuSO 4 reference electrodes. Most electrodes were located below the water table in clay or silty clay; some were in drier chalk and marl soils. There was a suspicion that at some locations the sub surface water flows might be sufficient to encourage accelerated electrolyte loss from within the porous tube electrodes; it has not been possible within the present program of activity to retrieve any electrodes and examine them in detail. It is hoped that this will be done in the next few months. The priorities were to progress with the extensive improvement works for the CP systems and to pragmatically select accurate and reliable electrodes for the balance of the works. The Trials A program was instigated to procure what, by reputation, were anticipated to be high quality reference electrodes from reputable manufacturers from the UK and USA, to assess their build quality and to install them at a single location on the same pipeline in a test site that replicated the previous installations. Reference electrodes were procured from: In the UK: Anglia Cathodic Protection Services Ltd (ACAPS) Cathodic Protection Company Ltd Corrpro Companies Europe Ltd Silvion Ltd In North America (USA & Canada): Corrpro Inc. Electrochemical Devices Inc. GMC Electrical Inc. M C Miller Co. Inc. In total 12 No. permanent reference electrodes of different manufacturers and types were tested. This included old fashioned ceramic porous pot electrodes with a high volume of Cu/CuSO 4 electrolyte and quite large copper electrode area, to claimed high technology Cu/CuSO 4 electrodes with ion exchange membranes, some claiming suitability for use in high chloride soils, and the full range of simple to complex in between. One Ag/AgCl/0.5M KCl electrode claimed to be designed for soil usage was also trialed. We did not include in the testing regime well known manufacturers with whom we had previous experience of poor performance. All electrodes were installed at a single site, in the same manner to that which had been employed in the original enhancement programme, using a water jetting technique to produce a hole of the required dimensions to inset the electrode. The optimum hole size for installation at all the sites intended was only 80mm diameter Page 3 of 6

but at the test site there was a good local water supply and larger holes were produced for the lager diameter electrode assemblies. Electrodes were backfilled initially in a gypsum/bentonite backfill intended to keep them securely moist and in good contact with the soils; this approach had been taken during the initial deployment in 2012. It is known that some claim that such backfilling can cause small errors in junction potential; it was our assessment that any such errors are small compared with risks of electrodes drying out or having poor contact with the soil. The holes were then hand tamped full with compacted soil removed from the hole. Later this test site was supplemented to allow field gradient measurements to be made proximate to the electrodes, to ensure that the apparent changes in electrode potential that were being measured were not influenced by the sometimes fluctuating field gradients. This was confirmed; the field gradient across a 1m distance, in the same direction as the 500mm spacing between the permanent and portable electrodes, was typically less than 5mv and the peak value measured was 10.4mV. 12 No. electrodes were tested, and continue to be tested, with data currently at 28 weeks after installation showing, of the 12 No. electrodes tested from the 8 No. manufacturers, one was in error by >130mV. The least accurate electrode was not from the originally selected manufacturer whose electrodes showed errors of approximately -200mv to +130mV as in Table 1 above. The electrode of the same type as deployed along the pipeline in 2012 was in error by >60mV at the test site. The 2 No. simple old fashioned porous pot electrodes were amongst the best performing electrodes with one showing a maximum error of +25mV and the other +21mV. Both of these would have presented dimensional problems for the optimum method of installation. Only 5 No. of the 12 No. electrodes were accurate to +/- 20mV of their theoretical potential (which was assessed to include a maximum of 10mV soil potential gradient "error"). The Ag/AgCl/0.5M KCl electrode which was included in the testing (converted to Cu/CuSO 4 by a debateable 40mV conversion factor) was accurate throughout the trials to within 14mV (which was assessed to include a maximum of 10mV soil potential gradient "error"). In parallel to the field testing, all of the electrodes which could not be viewed during construction were sectioned in order to visually assess the construction quality. The intention of this visual assessment was to attempt to make subjective assessments of the cable to electrode connection and its insulation from the electrolyte, of the assembly quality and to determine from visual appearance of the electrolyte how it had been either gelled (with a gelling agent such as gelatine) or made solid typically with Plaster of Paris or gypsum. The simple porous pots were both assessed as reasonably well constructed and both performed relatively well. Page 4 of 6

The claimed high technology units from two manufacturers were assessed as reasonably well constructed; of these one performed particularly poorly and two performed reasonably well. One performed extremely well, better than its more expensive, claimed superior, sibling from the same manufacturer. Three units of claimed high technology were assessed as particularly poorly constructed but all performed reasonably well; this may indicate that the subjective quality assessments from the sectioning of the cells were not as rigorous or appropriate as they were thought to be when the assessment was undertaken. The full data sets, anonymised, are presented in Figure 1. Conclusions The accuracy, or lack of accuracy, of permanent reference electrodes from a reputable manufacturer was only detected by the field provisions of unusually rigorous (at least in UK practice) testing provisions which allowed calibration of these with portable calibrated electrodes, at the same depth, within 500mm of the permanent electrodes. The errors were very significant and continue after some 12 months of deployment. Many of high quality premium producer electrodes performed poorly in the subsequent field tests intended to select accurate and stable electrodes for future works. The errors were very significant in electrodes from several manufacturers. We selected to use the only Ag/AgCl/0.5M KCl electrode in the trial for the ongoing installations on the basis of the good performance, small diameter which suits the preferred limited dig water jetting installation procedure and would also be suitable for the small proportion of test sites where chlorides are high. We do plan to recover some of the failed electrodes and to attempt to determine the cause of the inaccuracy. We will report this publicly if this is possible. Acknowledgement Thanks are expressed to my Client for permission to publish this work, with the intention of bringing to the attention of others in the pipeline cathodic protection community what we consider are important errors arising from the use of poorly selected reference electrodes. I thank them also for them being prepared to undertake trials, at their cost, in order to quickly determine what electrodes would be best for future works. I thank my colleagues who have assisted and provided technical support and guidance throughout all aspects of this complex project and undertaken much of the data collection for this small element of the overall work to improve the cathodic protection performance of these assets. Page 5 of 6

Figure 1: Permanent Reference Electrode Potential vs Calibrated Portable Electrode (500mm spacing at same depth) at same site. Weeks are not linear: Week 16 is actually after 28 weeks of trial. The Ag/AgCl/0.5M KCl electrode is corrected to Cu/CuSO 4 equivalent by 40mV. It is series 10 Page 6 of 6