JUNE 2003 REVISION. Submitted to: The American Iron and Steel Institute (AISI) Principal Investigator: Ben Schafer Assistant Professor

Similar documents
Effective Width Method Based Design for Distortional Buckling

JHU Experiments on Braced Thin-Walled Cold- Formed Steel C and Z Beams in Flexure

Distortional Buckling Tests on Cold-Formed Steel Beams

DISTORTIONAL BUCKLING OF C AND Z MEMBERS IN BENDING

S T R U C T U R. magazine. Direct Strength Method for Cold-Formed Steel. Copyright. What are the Advantages in Using Direct Strength Method?

BENJAMIN WILLIAM SCHAFER

THIN-WALLED COLUMN DESIGN CONSIDERING LOCAL, DISTORTIONAL AND EULER BUCKLING


Acknowledgments. Specification complication. Cold-Formed Steel Design by the Direct Strength Method

New approach to improving distortional strength of intermediate length thin-walled open section columns

Analysis of Sheathed Cold-Formed Steel Wall Studs

Analysis of Sheathed Cold-Formed Steel Wall Studs

Investigation of Slenderness Ratio for Cold-Formed C-Section

TABULATED LOCAL AND DISTORTIONAL ELASTIC BUCKLING SOLUTIONS FOR STANDARD SHAPES

Torsion in thin-walled cold-formed steel beams

Design of Perforated Industrial Storage Rack Columns for Distortional Buckling

Direct Strength Design of Cold-formed C-sections in Combined Bending and Shear

Section Moment Capacity Tests of Rivet-Fastened Rectangular Hollow Flange Channel Beams

Local and Distortional Buckling of Cold-Formed Steel Members

Direct Strength Design of Cold-formed C-sections for Shear

BEAMS, PURLINS AND BRACING. 5.1 General The design of beams for strength is usually governed by one of the following limit states:

Distortional elastic buckling for aluminium: Available prediction models versus design specifications

Longwave Buckling of Cold-formed Steel Studs Using Direct Strength

AISI S E1 AISI STANDARD. Errata to North American Specification. for the Design of Cold-Formed. Steel Structural Members.

Computational modeling of cold-formed steel: characterizing geometric imperfections and residual stresses

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

ROTATIONAL RESTRAINT OF DISTORTIONAL BUCKLING IN COLD-FORMED STEEL FRAMING SYSTEMS

Shear tests of hollow flange channel beams with stiffened web openings

EXPERIMENTAL AND ANALYTICAL STUDIES OF THE BEHAVIOR OF COLD-FORMED STEEL ROOF TRUSS ELEMENTS

Lightweight Steel Framing. DeltaStud Load Tables

Draft - March 26, 2007

Advanced Ideas and Examples

The Behaviour of Cold-Formed C-Sections with Square Holes in Shear

STUDY ON THE EFFECT OF SPACERS ON THE ULTIMATE CAPACITY OF INTERMEDIATE LENGTH THIN WALLED SECTION UNDER COMPRESSION *

Interactive Analysis and Design of Cold-formed Steel Cladding System

Numerical Modeling and Finite Element Analysis of Steel Sheathed Cold-Formed Steel Shear Walls

The 2008 AISI Cold-formed Steel Design Manual

Sheathing Braced Design of Wall Studs

Testing and Evaluation of CFS L-headers

Development of a Cold Formed Steel Housing System

Simple Complex Simple Complex

Experiment on Precast Solid Concrete Floor Slabs resting on Cold- Formed Steel Framing Stud Walls

FLEXURAL BEHAVIOUR OF STIFFENED MODIFIED COLD-FORMED STEEL SECTIONS EXPERIMENTAL STUDY

Load-carrying Capacity Estimation on Coldformed Thin-walled Steel Columns with Built-up Box Section

Local and Distortional Buckling of Cold-formed Steel Studs

Structural Performance of Bolted Moment Connections among Single Cold-Formed Channel Sections

A COST BASED APPROACH TO DESIGN OF RESIDENTIAL STEEL ROOF SYSTEMS

Buckling Analysis of Cold Formed Steel for Beams

research report The Strength of Stiffened CFS Floor Joist Assemblies with Offset Loading RESEARCH REPORT RP REVISION 2006

I. INTRODUCTION. International Journal of Engineering Innovation & Research Volume 4, Issue 4, ISSN:

Web Crippling Tests of Cold-formed Steel Channels under Two Flange Load Cases

On the Stability and Strength of Steel Columns Affected by Distortional Buckling

The 2013 AISI Cold-Formed Steel Design Manual

Behavior of Continuous Span Purlin Systems

Behaviour of Cold-Formed Steel Built-up I Section Under Bending

The University of Sydney School of Civil Engineering Centre for Advanced Structural Engineering NSW 2006 Australia. SupaPurlin

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

DISTORTIONAL BUCKLING BEHAVIOUR OF FIRE EXPOSED COLD-FORMED STEEL COLUMNS

Local and Distortional Buckling of Thin-walled Beams

Direct Strength Design for Cold-Formed Steel Members with Perforations. We look forward to your comments regarding this ongoing research.

BRACING STIFFNESS AND STRENGTH IN SHEATHED COLD-FORMED STEEL STUD WALLS

research report Strength of CFS Floor Assemblies with Clip Angle Bearing Stiffeners RESEARCH REPORT RP REVISION 2006

Research Article Numerical Analysis of Eccentrically Loaded Cold-Formed Plain Channel Columns

FE modeling of elastic buckling of stud walls

Materials and Joints in Timber Structures: Recent Advancement of Technology, Proceedings of the RILEM 2014 Conference

Buckling Experiments on Hollow Flange Beams with Web Stiffeners

Experimental Study on Distortional-Global Interaction Buckling of Stainless Steel C-beams

E-Beam HD. Cold-Formed Insulated Composite Structural Elements. Engineering/Analysis Report

PARAMETRIC STUDY OF HIGH THIN-WALLED Z-PURLINS STRUCTURAL CONNECTION WITH ADDITIONAL CLIP

TECHNICAL NOTE HEADER DESIGN. On Cold-Formed Steel Construction INTRODUCTION BOX HEADERS $5.00

Web Crippling of Cold-formed Steel Members

MECHANICAL BRIDGING AND BRIDGING ANCHORAGE OF LOAD BEARING COLD-FORMED STEEL STUDS. Paul E. Lackey, EIT Nabil A. Rahman, Ph.D.

Local Buckling Tests on Cold-formed Steel Beams

Experimental Investigation of the Distortional-Global Interaction Buckling of Stainless Steel C-beams

Design of Cold-formed Steel Stiffened Elements with Multiple Longitudinal Intermediate Stiffeners

Shift of the Effective Centroid of Channel Columns

Web Crippling Tests of Cold-formed Steel Channels under Two Flange Load Cases

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

Experimental Study on Load Carrying Capacity of Cold Formed Steel Built-up Column

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

Composite Beams of Cold Formed Steel Section and Concrete Slab

Testing of Bolted Cold- Formed Steel Connections in Bearing (With and Without Washers) RESEARCH REPORT RP01-4

Geometric Imperfections and Residual Stresses for Use in the Analytical Modeling of Cold-formed Steel Members

HSS section calculations are based on the AISC Steel Construction Manual, 13 th edition (ASD only).

TESTS OF THE LOCAL RESISTANCE OF THIN-WALLED Z-PURLINS CLIP CONNECTION TO THE SUPPORTING STRUCTURE

Keywords: steel structures, cold-formed steel angles, structural stability, numerical analysis, non-linear analysis.

CHAPTER 2 LITERATURE REVIEW

Experimental Investigation of Cold-formed Steel Beam-column Sub-frames: Pilot Study

Behavior and Strength of Cold-formed Steel Framed Shear Walls Sheather with Composite Panels

research report Reinforcement Schemes for CFS Joists Having Web Openings RESEARCH REPORT RP08-6 American Iron and Steel Institute

SEISMIC BEHAVIOR OF STEEL RIGID FRAME WITH IMPERFECT BRACE MEMBERS

Pull-Through Failure Tests of Thin Steel Roof Battens under Wind Uplift Loads

James Hauck 1 and Christine Moe 2

Buckling Analysis of Cold Formed Steel Compression Members at Elevated Temperatures

LITERATURE REVIEW OF WEB CRIPPLING BEHAVIOUR

Introductory Questions

Analysis-based 2D design of steel storage racks. Author. Published. Journal Title DOI. Copyright Statement. Downloaded from. Griffith Research Online

Cold Formed Steel Flat Width Ratio Limits, D/t and Dáµ /w

Marian A. GIZEJOWSKI Leslaw KWASNIEWSKI Wael SALAH

under Buckling Behavior

Transcription:

JUNE 2003 REVISION DISTORTIONAL BUCKLING OF C AND Z MEMBERS IN BENDING Project Plan for PHASE 2 of TEST VERIFICATION OF THE EFFECT OF STRESS GRADIENT ON WEBS OF CEE AND ZEE SECTIONS Submitted to: The American Iron and Steel Institute (AISI) Principal Investigator: Ben Schafer Assistant Professor Department of Civil Engineering The Johns Hopkins University Baltimore, Maryland June 2003 Abstract Distortional buckling of cold-formed steel C and Z members in bending remains an unaddressed problem in the current North American Specification (AISI 2002). When the compression flange is not stabilized by fastening to panels or sheathing, such as in negative bending of continuous members (joists, purlins, etc.) and wind suction on walls and panels (without interior sheathing) members are prone to distortional failures. Adequate experimental data on unrestricted distortional buckling in bending is unavailable. It is proposed to extend a recently completed experimental project on local buckling of C and Z members in bending, to a second phase on distortional buckling. Further, it is proposed to begin work on understanding the role of restraint in distortional buckling both experimentally and numerically. The experimental work may be completed by using geometry similar to that of the Phase 1 testing, but removing the throughfastened panel attached to the compression flange. Subsequently, exploratory work on fastener details and panel stiffness may be pursued. The experimental data will help develop and validate an efficient and reliable design procedure for C and Z members in bending with and without panels attached to the compression flange failing in local or distortional buckling and form the basis for more advanced design methods that account for situations of partial restraint. Distortional Buckling of C and Z Members in Bending 2

1. Background Existing experimental and analytical work indicates current provisions, North American Specification (AISI 2002), are inadequate for predicting bending capacity of C and Z members when distortional buckling occurs (e.g., Hancock et al. 1996, Rogers and Schuster 1995, Schafer and Peköz 1999, Yu and Schafer 2002). While recent work on the effective width of webs to combine the best of the AISI (1999) and S136 (1994) methods has been completed and adopted (AISI 2002) a great deal of work remains on local buckling interaction (Figure 1a) between the flange and the web, and distortional buckling (Figure 1b). (a) local buckling ½ wavelength ~ 5 in. (127 mm) (b) distortional buckling ½ wavelength 27 in. (686 mm) Figure 1 Local and distortional buckling of a typical 8.5 in. (216 mm) deep Z in bending A joint MBMA-AISI project recently completed at Johns Hopkins University: Test Verification of Effect of Stress Gradient on Webs of Cee and Zee Sections, provided necessary experimental support to address local buckling and shed light on local web/flange interaction. However, the testing was focused exclusively on local failure modes, and distortional buckling was restricted by the use of a panel through-fastened to the compression flange at a close fastener spacing. This Phase 1 testing provides the upper-bound capacity for a bending member failing in the local mode. This proposal details Phase 2 work on distortional buckling of the same C and Z members examined in Phase 1. There is a significant need for the Phase 2 work. Although most C and Z members in bending have attachments (panel or otherwise) which stabilize the compression flange and restrict distortional buckling many do not. Negative bending of continuous members (joists, purlins, etc.) and wind suction on walls and panels (without interior sheathing) are common examples where no such beneficial attachments exist these members are prone to distortional failures. Even when attachment to the compression flange exists it may not fully restrict distortional buckling as may be the case for thin panels with large center to center fastener spacing and thick insulation between the purlin and panel. Further, flexural members are in general more prone to distortional failures than compression members, due to the dominance of local web buckling in typical compression members. Geometry, unique to flexural members, such as the sloping lip stiffeners used in Zs are inefficient in retarding distortional buckling. For example, a typical 8 in. (216 mm) deep Z with t = 0.120 in. (3 mm) has a distortional buckling stress that is ½ the local buckling stress. The advent of higher strength steels also increases the potential for distortional failures (Schafer 1999, 2002a). The AISI Committee on Specifications has listed distortional buckling in its strategic plan; in many flexural members, left unrestricted, distortional buckling is the expected failure mode. Distortional Buckling of C and Z Members in Bending 3

2. Statement of Work 2.1 Sections It is proposed to use the same specimen geometry as employed in the Phase 1 studies. For Phase 1 the Zs were provided by an MBMA member company and consisted of standard 8.5 in. (216 mm) and 11.5 in. (292 mm) deep members at several different thicknesses. The Cs were provided by an SSMA member company and consisted of 8 in. (203 mm) deep Cs with 2 in. (51 mm) flanges at several different thicknesses, as well as a set of 3.6 in. (91 mm) to 12 in. (305 mm) deep Cs with 2 in. (51 mm) flanges and constant thickness. A selection of the cross-sections to be tested is summarized in Figure 2 and Table 1. The members are selected to provide a compromise between testing at the extremes (i.e., variations in h/t, h/b, etc.) while still testing those products that see significant use in current practice. With the panels removed from the compression flange, both local buckling and distortional buckling are free to form. Examination of the ratio of the elastic distortional buckling moment (M crd ) to the elastic local buckling moment (M crl ) indicates that a large number of members, particularly the Zs, are anticipated to fail in a mechanism dominated by distortional buckling (i.e., M crd /M crl < 1). Note even when M crd /M crl > 1 distortional buckling may govern because of reduced post-buckling strength in distortional failures (Schafer 1999). Table 1 Summary of Proposed Specimens for Testing h/t h/b b/t d/t d/b McrD/McrL Tests to be performed num min max min max min max min max min max min max Z Study 1: h,b,~d fixed, t varied 7 70.8 144.1 3.4 same 20.8 42.4 8.4 12.6 0.28 0.41 0.52 0.83 Z Study 2: h,b,~d fixed, t varied 5 95.8 157.5 3.3 same 29.2 47.9 8.4 12.6 0.26 0.29 0.61 0.88 C Study 1: h,b,d fixed, t varied 5 82.5 242.4 4.0 same 20.6 60.6 6.4 18.9 0.31 same 0.69 1.79 C Study 2: b,d,t fixed, h varied 5 67.0 222.2 1.8 6.0 37.0 same 11.6 same 0.31 same 0.72 1.27 Additional tests on outliers 6 dimensions to be determined based on test results TOTAL 28 67.0 242.4 1.8 6.0 20.6 60.6 6.4 18.9 0.26 0.41 0.52 1.79 h = out-to-out web depth r = inside corner radius b = out-to-out flange width t = thickness d = out-to-out lip length (a) 8.5 in. Z (b) 11.5 in. Z (c) Min depth C (d) Max depth C Figure 2 Typical geometry of C and Z members to be tested 2.2 Testing The four point bending test setup developed in Phase 1 will be used for the Phase 2 testing proposed herein. The only anticipated modification is the removal of the through fastened panel in the constant moment region of the test (Figure 3). The length of the constant moment region was specifically selected to insure that at least 2 distortional buckling half waves could occur in the constant moment region (half-wavelength was predicted by finite strip analysis of the nominal specimens). The Phase 1 testing arrangement is shown in Figure 4 along with a typical Distortional Buckling of C and Z Members in Bending 4

failure with the panel in place (Figure 5). Full details of the testing arrangement, development of the testing details, progress reports, pictures, and all other details related to the Phase 1 work can be found at www.ce.jhu.edu/bschafer. It is proposed, that if a reduced number of tests in each group may be used to establish the distortional buckling lower bound, then the remaining tests will be used to experimentally study the influence of panel stiffness on the behavior. Further, additional fastener details may be investigated as well. These experiments will be used to provide an initial exploration of the influence of partial restraint, and provide data for use in numerical studies. Figure 3 Proposed Test Arrangement Figure 4 Phase 1 testing setup (top panel in the constant moment region will be removed and dist. buckling allowed to occur in Phase 2) Distortional Buckling of C and Z Members in Bending 5

Figure 5 Phase 1 failure mode (top panel in the constant moment region will be removed and dist. buckling allowed to occur in Phase 2) 2.3 Evaluation The experimental results will be used to directly evaluate the effectiveness of existing and proposed procedures for the bending capacity of laterally braced C and Z members without compression flange support (panel, sheathing, etc.). The following methods will be evaluated: North American Specification (AISI 2002) Australian/New Zealand Specification (AS/NZS 4600) Proposed methods from related Phase 1 work (Schafer and Peköz 1999) Direct Strength method (Schafer 2002b) When appropriate, existing tests may be used to supplement the results of the proposed study in the evaluation phase. 2.4 Analysis The proposed experimental data is large enough in scope to provide insight on a variety of common members, but like any experiment it is necessarily limited. To augment the experimental data and develop further insight on the role of restraint in bending of C and Z beams with and without attached panels, it is proposed to perform: finite strip analysis of all members tested, eigenvalue finite element analysis of the complete setup, member + attachments, and general nonlinear finite element analysis of the complete setup. The nonlinear analysis is anticipated to be particularly useful in examining flanges which are partially restrained. The role of discrete fastener spacing and panel stiffness may be readily modified once initial modeling verification is completed. The proposed analysis will only serve to augment the experimental work and large parametric studies are not envisioned as part of this proposal. Distortional Buckling of C and Z Members in Bending 6

2.5 Work Product Brief progress reports will be provided electronically (email and web page) through the duration of the project. In addition, a written report will be provided every 6 months. A report will be provided upon completion of the project. Upon review and incorporation of comments a final report will be provided. All test data and reports will be made available in electronic format (Excel, Word, PDF files as appropriate). The work will include a ballot and an example problem for the suggested method to predict the flexural strength of laterally braced C and Z members with and without through-fastened panels in the compression flange. 3. Impact on Industry C and Z members are arguably the most common cold-formed steel members in use today. Reliable innovation in cold-formed steel products and applications requires that the ultimate strength of these members be predicted accurately. Current North American Specification procedures only partially account for distortional buckling and ignore local web/flange interaction. Adoption of new methods that account for these effects will obviously provide different strength prediction than current methods. In some cases the new methods will indicate increased capacity previous work on columns indicates that members with relatively long lips (compared to current practice) and certain h/b ratios will likely be rewarded. In other cases, for example, members without any attachment to the compression flange, a reduction compared to current strength predictions is likely. The author of this proposal submits that a more accurate and robust Specification will in the long-term lead the industry towards better members, even if in the short-term predicted strength in some situations decreases. 4. Schedule The proposed schedule for this project is for completion twelve months after the required material for the test specimens are obtained. It is anticipated that a task force of interested parties from the AISI Committee on Specification and all funding participants will be assigned to this project. The active participation of this task force will significantly benefit the final outcome. 5. Facilities Research facilities are located in the Structural Engineering Laboratory at the Department of Civil Engineering, Johns Hopkins University. Hydraulic actuators, hydraulic and screw driven universal testing machines, load cells, extensometers, LVDTs and traditional dial gauges are all available for use. Multi-channel data acquisition systems are available to simultaneously gather strain, load and displacement data during the tests. A machine shop with milling equipment, lathe etc. is available for machining pieces, supports, braces etc. needed in the test setup. 6. Personnel A graduate student (Cheng Yu, recipient of a 2002 MBMA Fellowship) will be assigned to the project to work under Assistant Professor Ben Schafer. In addition, Jack Spangler, the Civil Engineering Department Technician will be available to help in the experimental setup and measurement systems for the duration of the project. A one page resume of the principal investigator is attached. Distortional Buckling of C and Z Members in Bending 7

7. References AISI (1996). AISI Specification for the Design of Cold-Formed Steel Structural Members. American Iron and Steel Institute. Washington, D.C. AISI (2002). North American Specification for the Design of Cold-Formed Steel Structural Members. American Iron and Steel Institute. Washington, D.C. AS/NZS (1996) AS/NZS 4600: 1996 Cold-Formed Steel Structures, Standards Australia and the Australian Institute of Steel Construction. CSA (1994). CAN/CSA-S136-94, Cold Formed Steel Structural Members. Canadian Standards Association. Hancock, G.J., Rogers, C.A., Schuster, R.M. (1996). Comparison of the Distortional Buckling Method for Flexural Members with Tests. 13 th In l. Spec. Conf. on Cold-Formed Steel Structures, 125-140, St. Louis, MO. Rogers, C.A., Schuster, R.M. (1995) Interaction Buckling of Flange, Edge Stiffener and Web of C-Sections in Bending. Research Into Cold Formed Steel, Final Report of CSSBI/IRAP Project, Department of Civil Engineering, University of Waterloo, Waterloo, Ontario. Schafer, B.W., Peköz, T. (1998). Direct Strength Prediction of Cold-Formed Steel Members using Numerical Elastic Buckling Solutions. 14th Int.l Specialty Conf. on Cold-Formed Steel Structures. St. Louis, MO. Schafer, B.W., Peköz, T. (1999). Laterally Braced Cold-Formed Steel Flexural Members with Edge Stiffened Flanges. Journal of Structural Engineering. 125(2). Schafer, B.W. (2002a). Local, Distortional, and Euler Buckling in Thin-walled Columns. ASCE, Journal of Structural Engineering. 128(3) pp. 289-299. Schafer, B.W. (2002b) "Design Manual for The Direct Strength Method of Cold-Formed Steel Design" Final Report to AISI, Washington, D.C., available at www.ce.jhu.edu/bschafer/direct_strength Yu, C., Schafer, B.W. (2002). Local Buckling Tests on Cold-Formed Steel Beams. ASCE, Journal of Structural Engineering. (Submitted) Distortional Buckling of C and Z Members in Bending 8

EDUCATION Ph.D / M.S. B.S.E. PROFESSIONAL Senior Engineer BENJAMIN WILLIAM SCHAFER ASSISTANT PROFESSOR Department of Civil Engineering The Johns Hopkins University Cornell University (1995 1997) Civil/Structural Eng., Minor: Theoretical and Applied Mech. Thesis: Cold-Formed Steel Behavior and Design: Analytical and Numerical Modeling of Elements and Members with Longitudinal Stiffeners. Advisor: Teoman Peköz University of Iowa (1989 1993) Civil Engineering Simpson Gumpertz & Heger, Inc., Arlington, MA (1998 2000) Eng. Mech. & Infrastructure Division. Failure Investigations, Buried Structures, Seismic Consulting RESEARCH Assistant Professor Postdoctoral Associate TEACHING Asst. Prof. Instructor Guest Lecturer The Johns Hopkins University (2000 Present) Current Projects: Decision-Theoretic Methodology for Performance-Based Structural Engineering, Completed Projects: Test Verification of the Effect of Stress Gradient on Webs of Cee and Zee Sections, Distortional Buckling of Cold-Formed Steel Columns Cornell University (1997 1998) Cold-formed steel members: distortional buckling behavior, torsional behavior, design procedures. Elastic post-buckling frame stability via bar/spring modeling. The Johns Hopkins University (2000-2001) What is Engineering?, Steel Structures, Structural Stability Cornell University (1997-1998) Structural Behavior, Modern Structures Cornell University (1995-1998) Adv. Design of Metal Structures, Adv. Behavior of Metal Structures SERVICE & ACTIVITIES Member Committee Work American Society of Civil Engineers (ASCE) (1991 Present) United States Association for Computational Mechanics (USACM) (1998-Present) Structural Stability Research Council (SSRC) (2001 Present) American Iron and Steel Institute Committee on Specifications (AISI-COS) (1995 Present) Member of main committee and subcommittees: 10, 22, 24, 26, 30, 31. ASCE-SEI Committee on Cold-Formed Steel, member (1997-2000) Chairmen (2001 Present) ASCE-SEI Committee on Compression and Flexural Members, member (2001 Present) ASCE-EMD Committee on Stability (2001 Present) SSRC TG 13, Thin-Walled Metal Construction, member (2001 Present) SELECTED PUBLICATIONS: Schafer, B.W. (2002) "Design Manual for The Direct Strength Method of Cold-Formed Steel Design" Final Report to the American Iron and Steel Institute, Washington, D.C., available at www.ce.jhu.edu/bschafer/direct_strength Yu, C., Schafer, B.W. (2002). Local Buckling Tests on Cold-Formed Steel Beams. ASCE, Journal of Structural Engineering. (Submitted) Schafer, B.W. (2002). Local, Distortional, and Euler Buckling in Thin-walled Columns. ASCE, Journal of Structural Engineering. 128(3) pp. 289-299. Gotluru, B.P., Schafer, B.W., Peköz, T. (2000). Torsion in Thin-Walled Steel Beams. Accepted for publication in Thin- Walled Structures Journal. Schafer, B.W., Peköz, T. (1999). Laterally Braced Cold-Formed Steel Flexural Members with Edge Stiffened Flanges. Journal of Structural Engineering. 125(2). Schafer, B.W., Peköz, T. (1998). Cold-Formed Steel Members with Multiple Longitudinal Intermediate Stiffeners in the Compression Flange. Journal of Structural Engineering. 124(10). Schafer, B.W., Peköz, T. (1998). Computational Modeling of Cold-Formed Steel: Characterizing Geometric Imperfections and Residual Stresses. Journal of Constructional Steel Research. 47(3). Schafer, B.W., Grigoriu, M., Peköz, T. (1998). A Probabilistic Examination of the Ultimate Strength of Cold-Formed Steel Elements. Thin-Walled Structures Journal. 31(4). Distortional Buckling of C and Z Members in Bending 9