FOUNDRY TECHNOLOGY BULLETIN

Similar documents
Installation Guidelines Plibrico. Plastic Refractories. Technical Bulletin

Engineering Guide For Zircoa s Foundry Crucibles

EXCEL and HIMELT crucibles

Refractory Alternatives to Combat Elephant's Foot Erosion and Top Cap Wear in Coreless Furnaces

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

Start-Up Procedure For Model EM-46, EM-810

LINING SYSTEMS HIGH PERFORMANCE LINING TECHNOLOGY FOR ALUMINIUM FOUNDRIES. + + Excellent refractoriness. + + Consistent performance

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware

SECTION GYPSUM BOARD

Introduction. Before you begin. Structure installation

specialist refractory solutions

ADD PROTECTION RETAIN HEAT. Need ladle solutions to optimize refractory performance? We ve got you covered. alliedmineral.com

SECTION QUARRY TILE

HIGH TEMPERATURE CERAMIC & GRAPHITE ADHESIVES

Perry Fiberglass Products, Inc. LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

MAKING, CURING AND TESTING CEMENT TREATED AND UNBOUND BASES (Kansas Test Method KT-37)

This procedure applies to the operations of two 5000 lb. capacity furnaces with one 1250 kw variable frequency power unit to melt steel.

Cast Stone Institute Plant Certification Program

TECHNICAL SPECIFICATION

Stop and Read Before Installing Material

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

Decorative Fiberglass Reinforced Wall Panels

Hardscaping Installation Manual

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

SECTION RESINOUS FLOORING

Multi-Piece EasyStep Product Installation Instructions

Section 11: Repair of Rubber Lined Equipment

DEEP SOAK PRODUCT REQUIREMENTS. A. Product Requirements. B. Product Inspection. C. Clearance Requirements T01-A

Installation Instructions

ABOUT ALLIED. Global Refractory Solutions

Chimney Lining Systems

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

PRELUDE K-8266T/K-8267T/K-8268T/K-8269T K-8270T/K-8271T/K-8273T/K-8275T QUIETUDE K-8262T/K-8263T

SUPREX CRUCIBLES PRODUCT CATALOGUE.

ARDEX UI 720 FLEXBONE

Installation Guide DROP-IN OR FREESTANDING CAST IRON BATH. English page T01-B

DETERMINATION OF WORKABILITY OF FRESH CONCRETE BY SLUMP TEST

EXCEL E is used for melting, holding and melt/holding of aluminum alloys in electric resistance and gas-fired furnaces.

Outline CASTING PROCESS - 2. The Mold in Casting. Sand Casting Mold Terms. Assoc Prof Zainal Abidin Ahmad Universiti Teknologi Malaysia

Installation Instructions. Important. Recommended Tools. Palladium Rigid Sheet/Rubrail or Palladium G2 Sheet/Rubrail. Storage

Multi-Piece EasyStep Product Installation Instructions

Semstone Construction Details

Impression Graphic panels

TECHNICAL SPECIFICATION FOR MATERIAL

Perry Fiberglass Products, Inc. LEADERS IN FIBERGLASS REINFORCED PLASTIC PIPE PRODUCTS

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

52 NORTON THE MUSCLE BEHIND THE MACHINE

GENERAL GUIDELINE SikaTack Panel System / VERSION 1 / SIKA SERVICES AG

Ceramic Processing. Engineering Materials. 7/15/2009 Ceramic Processing/S.Rattanachan 1

Florock Seamless Flooring Systems

Fiber Reinforced Tile and Stone Mortar

Installation Guide Wall Panels

Effects and Analysis of Thermal Stresses on Large Induction Furnace Refractory Linings for Molten Metal Applications

Product: Ready mix brick slip adhesive

COMPOSITE (WPC) ENGINEERED VINYL FLOORING INSTALLATION

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Straight Panel Bath Screen Instruction Manual

Installation Guide ENAMELED CAST IRON APRON BATH. English page T01-A

Soil Volume Change Meter (PVC)

TECHNICAL INFORMATION CEMSCREED 5

One Meter Internal Dome Oven AVERAGE GUIDE

Monolithic concept solutions for. Aluminium

INSTALLATION INSTRUCTIONS

BIOVE PRODUCT REQUIREMENTS. A. Introduction. B. Installer Hazard Notification. A. Summary Of Key Requirements. B. Product Inspection T01-B

EMBANKMENT AND BASE WAQTC FOP AASHTO T 99 / T 180 (18) IN-PLACE DENSITY

ITEM NO. 307 CONCRETE STRUCTURES

Thin Architectural Splitface Block Veneer Specification Guide

CRD-C Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforced Steel

52 NORTON- R TE JAR A T.C OM

ARDEX X 32 MICROTEC Universal Rapid Setting and Drying Thin-to-Thick Bed Mortar

SECTION 44 SHOTCRETE, CAST CONCRETE CHANNEL LINING, AND GROUTED COBBLE TABLE OF CONTENTS

PSI Crack Injection Repair Guide. Surface Preparation for Crack Injection

PRODUCT DRYMIX CODEMIX

WALL TILE CHARACTERISTICS

Perfect 69 x 37 Drop-in Acrylic Bath

Lakes. COASTLINE LEVANZO Hinged Bypass Panel Installation / Maintenance Instructions. Bathrooms. Rev 01.16

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. RobinsonBrick.com

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Refractories 1999 U S C E N S U S B U R E A U. Current Industrial Reports. Helping You Make Informed Decisions. (Formerly Series No.

17.0 CONSTRUCTION OF OPEN DRAINAGE SYSTEMS

Easy to cut with every tile layer s everyday tools.

FLOOR COVERING Arch206 BC-II Spring 2016

Current Refractory Technology and Practices in the Steel Industry

Florock Seamless Flooring Systems

in ferrous foundry industry

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

1850 x 40/50mm Raised Shower Tray Kit

Abrasive mop discs for

City of Regina Standard Construction Specification SECTION 2350 PLACEMENT OF ASPHALTIC CONCRETE SURFACE 1.0 GENERAL. 1.1 Scope

Use of Rheocasting Mould in SSM Processing

Maintenance of Wood, Plastics and Composites. Wood Restoration

SECTION BUILT-UP BITUMINOUS WATERPROOFING

Milking Parlour Floors Tom Ryan, Teagasc Specialist Service

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

ASH GROVE KOLORSTONE BROOMCOAT MIXING KIT. Spec Sheets Contents: Kolorstone Broomcoat Mixing Spec Sheet Kolorflex Admixture Spec Sheet

YOW 250 T Window System

San Antonio Water System Standard Specifications for Construction ITEM NO. 307 CONCRETE STRUCTURES

Rev. 07 8/15 Please Read Disclaimers:

Soluble Silicates in Refractory and Chemical- Resistant Cements

CONSULT COLDSPRING FOR ASSISTANCE IN EDITING THIS SPECIFICATION GUIDE FOR SPECIFIC APPLICATIONS.

Transcription:

Foundry Division FOUNDRY TECHNOLOGY BULLETIN CRUCIBLE INSTALLATION IN AN INDUCTION STRAIGHTWALL FURNACE The proper installation of Silicon Carbide and Clay Graphite crucibles in induction furnaces is critical to extending crucible life and assisting in providing safe working conditions for the installation of Silicon Carbide and Clay Graphite crucibles. 1) The furnace interior must be clean and the coil grout free of cracks. If any repair is necessary, use a coil grout such as Vesuvius Kellundite G. The grout should be evenly applied to the face of the coil to avoid slumping and when completed should be as smooth as possible, to form a nearperfect cylinder. If coil grout is used it should be completely dry before proceeding to ram the crucible. 2) A slip plane is recommended to allow for the vertical expansion of the refractory back-up lining. When dry, line the furnace with a slip plane medium such as Vesuvius Coreweave fiber glass cloth, or mica paper. The slip plane overlaps should all lie in the same direction and should be hung from the top of the furnace to the bottom and be contoured to fit against the furnace walls. The length required should equal the height of the furnace plus 5. This will allow for overlap onto the top of the furnace. The overlap cloth can be slit every 6 to allow it to contour the furnace properly. 3) After the leak detector wires are set in place (per the manufacturer s specifications), the back-up refractory can be installed in the furnace bottom: a) The dry refractory material should be installed in 3 to 4 layers. Each layer must be leveled, de-aired, and firmly tamped. (3 to 4 passes of each step) de-airing should be accomplished using forking tool (Print D-7320). A ramming tool (Print D-7323) is typically used to ram the bottom. After ramming, the refractory will feel and appear dense. b) Prior to installing the next layer, the surface of the previously tamped layer must be thoroughly scratched to avoid laminations and grain segregation. This is accomplished by using the forking tool. (Print D-7320) c) Continue the practice outlined in steps a and b until the bottom refractory rammed height is 1 higher than required. Remove and level the excess 1 material with a straight edge. This will provide optimum density and bottom support for the crucible. This should bring the INSIDE base of the crucible to the level of the active power coil not the inactive water-cooling coil.) Trim the 1

detector wire just above the rammed base before placing the crucible in the furnace. This should ensure they are in contact with the crucible base. 4) The crucible is lowered into the furnace, centered, and leveled. The leak detector wires must make contact with the crucible bottom. It is a good practice to stone off some of the glaze on the crucible bottom where the detector wires make contact with the crucible. The crucible should be stabilized in the furnace using wooden wedges along the sides or by placing some weight into the crucible bottom. The objective is to insure the crucible maintains its centered position while ramming the sidewalls. 5) After the crucible is properly positioned, all exposed refractory back up must be scratched with the forking tool. The sidewall refractory material is then installed using the same techniques as employed in the bottom installation. Typically, a RAM tool (Print D-7321) is used for the sidewalls. 6) After the dry sidewall material is installed, a Buffalo RAM 85 top cap plastic is installed to provide a seal for the dense refractory back-up, as well as an abrasion resistant surface for charging. If the crucible is not supplied with a spout then plastic can be used to form the spout at this stage. Finish the top with a trowel to give a good finish. Pierce the rammed material at intervals to allow moisture to escape during heat up. 7. Once the top cap is properly installed and the crucible/refractories are free of moisture heatup can be initiated. INDEX OF RECOMMENDED PRODUCTS MATERIAL TRADENAME COMPOSITION Slip Plane Coreweave Non-Asbestos Cloth Grout Mat. Kellundite G Silica Based Ref. Back-up Magnavibe 750 Magnesia Dry-Vib Top Cap 85 RAM PC 85% Phos-Bonded Alumina 2

3

4

5