Assembly Instruction. wedi Fundo Primo Shower System

Similar documents
Assembly Instruction wedi Fundo Floor element

Assembly Instruction. wedi Fundo Primo Steam Shower System

Shower & Spa System Solutions

Technical Data. wedi Prefabricated Elements

Ubau Flo Shower Element Installation Manual

Shower & Spa System Solutions. Innovation. System. Quality.

1 PVC or ABS drain with strainer

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

BioPrism Solid Surface

WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS

BioPrism Solid Surface

fusion shower pan on wood joists installation guide

adjustable fusion shower pan surface mounted on subfloor installation guide

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

adjustable fusion shower pan on wood joists installation guide

Shower Drain Installation Guide

OPEN SET SYSTEM. Easy-to-install Waterproofi ng Shower System. Installation guide

Shower Pan Extension Installation Guide

Publication date April 15, Technical handbook

wedi Fundo Ligno General product description Product features

Dural Durabase WP Installation Instructions For showers and general waterproofing (800)

When I started tiling, we didn t do our own shower pans that BATHS

USG DUROCK BRAND INFINITY DRAIN SHOWER SYSTEM Shower Floor and Drain Installation Guide

Low-Profile Multi-Piece Shower with blue, high-density polyurethane bottom

Impression Graphic panels

Triton WP Waterproof Membrane

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Watertight & maintenance-free. Schluter -Shower System FOR TILED SHOWERS

Typical Installation Details

Multi-Piece Shower with Trench Drain

Shower Pan Troubleshooting, Repairs, and Reliable Installation Techniques

Multi-Piece Shower with Trench Drain

30mm Height Linear Drain Shower Trays

INSTALLATION INSTRUCTIONS

Schluter -Shower System Installation Handbook Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds

Product Catalog and Installation Manual for: Multi-Panels XPS Tile Backer Board, Shower Tray and Underlayment for Floor Heating

Multi-Piece EasyStep Product Installation Instructions

SECTION TILING

Multi-Piece Shower with Trench Drain

HELPFUL HINT. This way your customer won t be without a working bathroom if you have to wait for a replacement.

Pro Advanced Custom MUD Tiled Shower Kit

Concept XPS standard shower tray

DeltaTrayTamar PCS. Installation Guide for Centre and Offset Drain. INSTALLING DELTATRAY tamar A PCS GUIDE TO CREATING THE PERFECT WETROOM

Infinity - Century Combination Installation Instructions Gelcoat & Solid Surface Bathware

Multi-Piece EasyStep Product Installation Instructions

PLYWOOD FLOATING FLOOR

Triton DCI Decoupling Mat

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

WARMUP TILED SHOWER SOLUTION

The next three paragraphs describe Chloraloy used as waterproofing for floors and walls at showers, tub surrounds, and other wet areas.

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

INSTALLATION INSTRUCTIONS

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware

Student Services & Classroom Addition

Easy Drain. INSTALLATION MANUAL Xs - Linear shower drain FOR WOODEN OR CONCRETE SUBFLOORS

Comprehensive solutions for installing showers

1. Sloped waterproof shower base for custom tile shower installations 2. Waterproofing 3. Linear Drain 4. Clamping Ring Drain 5.

Installation Instructions

SECTION TILING

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

Shower Tray - Timber Floors

MARMOX CONSTRUCTION BOARDS

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Shower Installation Manual APF Barrier Free Shower Models

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

The better way to build TM. Installation Manual NAILBASE PANELS

Pre-Fabricated Roof Curbs

Diamondback GlasRoc Tile Backer

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

Wabo ElastoFlex - EFJ/EFJ-C Horizontal Expansion Joint System

Division 7-Moisture Protection Section 7-Under Tile Waterproofing Exceeds ANSI A Rev. 05/2012 Page 1

Schluter -KERDI-DRAIN

INSTALLATION GUIDELINES

***************************************************************************************************************

LK Wallbox UNI Push X16 V2

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

WEIGHT PER PIECE (LBS.)

Easy Drain. Basic Drain ZERO. INSTALLATION MANUAL Basic Drain Zero - Linear shower drain

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Underlayment Systems

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

IT S WHAT S UNDERNEATH THAT COUNTS. MARMOX Shower Slope Shower Tray MEMBER OF CMB GROUP

STANDARD INSTALLATION GUIDELINES

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

Pre-Fabricated Roof Curbs

Installation Guide. for Wood Construction. The Level Entry Shower System Create Spa-Like, Accessible, Curbless Showers

RESIDENTIAL COMMERCIAL

Technical Data Sheet

Hardscaping Installation Manual

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

imperband standard kit

On load-bearing floors with LK Slotted Board EPS 16

Transcription:

Assembly Instruction wedi Fundo Primo Shower System

Assembly Instructions wedi Fundo wedi Fundo Shower System-Primo Overview & General Product Description of the wedi Fundo Shower Systems All wedi Waterproof Shower Systems including point and linear drain models offer reliable, costefficient solutions for constructing 100 % waterproof and mold proof showers. The product systems are entirely waterproof due to it s XPS extruded polystyrene foam core. These systems are easy and clean to install due to it s high prefabrication level. They open up a whole new world of design possibilities for showers, wet areas and baths when customized to fit your jobsite requirements. wedi Shower Systems blend the traditional values of design flexibility and robustness as previously only enjoyed with mortar bed installations, while offering added values that come with state-ofthe-art material and manufacturing technologies. These added values come in form of many performance advantages. Especially over traditional mortar bed installations or over other currently known methods for building showers such as those using sheet or liquid waterproofing membranes in an attempt to manage water exposure. The most unique advantage is the complete and natural core waterproofness of the wedi product and it s entire assembly. Every detail of the assembly is part of the wedi waterproofing approach: even down to the factory integrated drain parts. The concept of the wedi Fundo Shower System s water management describes a true water out performance. Neither products nor the assembly of the wedi Fundo shower system is subjected to the risks so commonly found in other methods of shower installation. When installing wedi Fundo Shower Systems in combination with wedi building panels, the proprietary wedi joint sealant and any of our curbs, niches or seats accessories, you can eliminate the following worries altogether: No overlapping sheet waterproofing seams with just thinset in between No risk of forming pinholes as with installation of very thin liquid membranes No weepholes and clogging as with liner installations No liner cracks due to aging or exposure to elements No risky liner seams in larger size showers nor any risky corner liner tapes No mold or discoloration worries as with absorbing and permanently wet mortar beds These added values and its detail perfections eliminate the technical concerns in shower installations. But this is not where wedi shower systems stop offering it s added values: The wedi Fundo shower system adds to your productivity and enables you to provide real value to your customers: Our wedi Fundo Shower systems reduce the installation time for just the shower floor from a 2 3 day process (includes drying times) to only 30 minutes when compared to traditional methods built with pre slope, vinyl liner and final mortar bed. wedi helps you to turn showers into service quicker, cleaner, safer. The exact and consistently shaped slope fields support perfection in tile setting and design. The cement based resin surface coatings on our products provide a great bond surface for any tile, stone and many other materials. Using any cement based thinset adhesives in installation. The insulation properties of the extruded foam core of our wedi systems keep the tile warmer on the floor and add to better insulation of the wall. And all this under one warranty for the entire shower from floor to wall.

Legend A Caulking nut B Rubber caulking gasket C Drain body D wedi sealant E Rubber gasket F Fiber gasket G Locking nut Optionally a glue drain can be obtained from wedi. For a cement glue connection, the floor pipe must be cut 2 1/4 inches below the surface of the subfloor. Optionally a brass drain can be obtained from wedi. The installation proceeds as shown for the standard PVC drain provided with each Fundo base. A B C D E F G 2 Tool & Material Bucket Notch Trowel Drill with Thinset Mixer Utility Knife Straight Edge / T Square 5 ft or longer Speed Square Caulk Gun Handsaw Flat Head Screwdriver Screw gun Solid Putty Knife Paper Towels Level Circular Saw Saw Horse Tape Measure Permanent Marker Extension Cord for Powertools Shop vacuum cleaner

Assembly Instructions wedi Fundo Installation instructions wedi Fundo onto wooden or concrete floors Before Installation Have 2 x 2 x 4 s installed between the studs (horizontally/ on floor) to back the bottom of wedi wall assembly Subfloor is sound, level and meets deflection criteria. Wooden or concrete structural substrates are dry and loadbearing. Steel framing is loadbearing. Floor joists not to exceed 16 o.c. Subfloor panels 3 /4 T&G EGP or equivalent. 2 PVC or ABS pipe is cut flush/ even with subfloor top surface and is in the correct position 2 drain assembly below floor is stabilized and will not sink under water load. Only wedi products (Building Panels, Curb, Joint Sealant and Fasteners) are used for wedi Fundo Shower System assembly. Installer has received instructions from wedi technical sales staff or is informed about proper installation methods as described wedi shower bases can be cut to size using a skilsaw. The Z notch channel must be remade and cleaned from sawdust or contaminants. 1 Cut the 2 pipe flush to the surface of the floor construction. Make sure that the cut out fits to the Fundo panel drain. Cut out a 5 diameter hole around the 2 pipe to allow the wedi drain to be inserted into the subfloor. The drain and trap have to be sturdily fastened to the sub floor. 2 Assemble the drain unit following the instruction drawing. 3 Set up a continuous 1 /4 bead of wedi sealant along the top side of the wedi Fundos valve groove profile. 4 Drop the drain body firmly into the sealant. 5 Turn the Fundo pan upside down and apply the rubber and the fiber gasket. 6 Tighten the gaskets firmly to the pans steel ring using the locking nut. Make sure the drain body is still safely received in the valve-bead of sealant.

7 Skim coat the thinset ANSI 118.4 and comb through with a 1 /4 x 1 /4 notched trowel. Channels pointing to the entrance. 8 Trowel the thinset on the rear side of the Fundo again using a 1 /4 x 1 /4 notched trowel. 9 Press the Fundo firmly into the thinset bed, ensuring that the installation is level and void free. Apply some weight equally and for at least 30 minutes (thinset bags). 10 Set up the rubber caulking gasket (with the bevelled side up) around the 2 pipe in the subfloor. The rubber gasket must be flush with the upper end of the 2 ABS or PVC pipe. Do Not use any Lubricants. 11 Tighten (squeeze) the rubber caulking gasket firmly with the caulking nut (use a flat headed screwdriver) and finally insert the plastic frame and strainer on top (without adhesive). The frame and strainer will be held in a flexible grout joint. 12 Set up a continuous 1 /2 bead of wedi sealant along the pans channel on the outer perimeter and only in areas where you can immediately install a building panel into the fresh sealant. 13 You are ready to install the wedi panels around the Fundo, fixed and sealed in the Fundo channels bead of sealant. Fasten the panels directly to the studs using one wedi fastener per foot. One extra fastener is set in between seams of panels to create a flush transition. 14 Set up continuous 1 /2 beads of sealant between and in all seams to adjacent panels. Excessive sealeant is smoothed out us - ing a putty knife. An addition al 1 /2 bead of sealant is set along the inside bottom joints connecting the wall panels and pan and spread flat over the joint. All fasteners are covered with sealant.

Assembly Instructions wedi Fundo 15 wedi Niches are installed in a cut out in the wedi wall and attach with it's flange right into the center of 16 o.c. studs. wedi joint sealant is set along the connection of wall to niche. 16 2 Fasteners each side of the niche are set to create a flush transition to the wall panels. Another 1 /2 bead of wedi seal - ant is spread over fasteners and seams. 17 A continuous 1 /2 bead of sealant is set into the channel and along the vertical curb notch part. A 1 /2 bead of seal - ant is set against both wedi walls. A 1 /2 bed of thin set mortar is set on the floor. The tightly cut to fit curb is pressed into the connnection. 18 Weight is applied for 30 minutes and another 1 /2 bead of wedi sealant is spread along all curb joints. After Installation Using a 2 drain plug, the wedi pressure fit drain/sealing gasket is water tested prior to ceramic tile installation and prior to other full surface flood tests. All bottom perimeter joints, curb joints and vertical joints are covered with wedi Joint Sealant. Coverage should be continuously visible for at least 3 /4 to 1 on each side of the joint. No mastic adhesives are used to install ceramic tile in the wedi system. A high quality modified thinset mortar is recommended. Tiles smaller than 2 x 2 inches require epoxy grout. Exception are pebble stones or river rock stones where a modified cement bade grout can be used. Large format tile can be used on wedi Fundo bases. The tiles must be cut where the slope fields meet. When complete wedi shower system is installed with wedi joint sealant, a water flood test may be performed only 2 hours after final application of wedi joint sealant (application temperature must be ambient/ interior with normal relative humidity and temperatures above 40 F). Where wedi building panel or curb overs / caps are installed over horizontal surfaces (seats, curbs, tubdeck transitions) do not set any fasteners and do not allow the glass door installation to penetrate the wedi panel as it is your waterproofing. Make sure that doors are installed tight to contain water inside the shower. Make sure doors are installed to only load bearing reinforced framing. Where wedi buildig panel is installed over corners of a structure showing an angle other than 90 please miter the board edges to gain adhesion surface. Utilize a wedi sealing tape in addition to regular sealing for safety.

Legend A wedi Strainer B Strainer Collar C Optional Extension Collar A B C Insert Strainer Collar into pan hole (no glue / no screws). Caulk between part and tile to create a flexible grout joint. Extension Collar can be cut to height if part is needed. The caulk joint must not create a water barrier damming up the water draining through the thinset bed into the drain. Therefore the thinset layer must be continuous toward the drain.

wedi corporation 1100 Landmeier Road Suite 200 Elk Grove Village, Il 60007 USA Tel.: +1-877-933-9334 Fax: +1-847-357-9819 info@wedicorp.com www.wedicorp.com D 10/13 K 10/13 A 90157000 wedi information and instruction is based on best knowledge and independent testing (UPC/IAPMO). wedi reserves the right to modify technical information and instructions.