Signature Seal 100 Medium-to-High Sheen Sealer VOC Characteristics and Applications

Similar documents
High Gloss Wet Look Lacquer

PERFORMANCE. Final Coat

Concrete Paving Sealer Clear, tough, gloss finish surface treatment.

FEATURES AND BENEFITS

STONE ESSENCE SEMI-TRANSPARENT STAIN FOR CONCRETE

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating

Product Information. DiamondCoat Polyurethane Concrete Floor Finish Clear, high build, high abrasion resistant, decorative concrete floor coating

Surface Guard. Product Data Sheet SPECIFICATION DATA CURE TIMES: (73ºF, 50% RH)

DESCRIPTION. DiamondCoat FEATURES AND BENEFITS AREAS OF USE

ChemMasters. Installation Guidelines

FEATURES AND BENEFITS

DESCRIPTION FEATURES AND BENEFITS AREAS OF USE. DiamondCoat Polyurethane Concrete Floor Finish is suitable for use in the following areas:

A guide to protecting masonry with a decorative sheen that extends the life of the surface.

Acrylitex Interior Texture and Coating Submittal Documentation

A-9,250 Parking Structure Resurfacing Cement Look

FEATURES AND BENEFITS

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

1. For routine cleaning of unpolished, honed or textured limestone using a cleaner and protector:

FEATURES AND BENEFITS

Technical Data Sheet PaveCoat Product Description

SILOXA-TEK 8505 TECHNICAL DATA SHEET

For routine cleaning of saltillo, terra cotta or clay brick using a cleaner and protector:

KUREZ DR VOX Dissipating Curing Compound

Acid Stain. Create amazing rich finishes with Westcoat. Acid Stain. Made from an acid solution, wetting agents, and metallic ions, Acid

Pool Paving Sealer Clear, natural finish, water repellent treatment.

STERI-FLAKE 470 HYBRID ESTER POLYMER, LIGHT-MEDIUM TRAFFIC, FLAKE FILLED FLOOR SYSTEM LOW ODOR MMA ALTERNATIVE FEATURES

Recommended Application Procedures

Recommended Application Procedures

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Ash Brook Golf Course Scotch Plains, New Jersey

Refer to Substrates & Surface Preparation.

Application and Maintenance Guide

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

Floor Care Solutions. Cost Effective, High Performance and Easy to Use Concrete Treatments

Sealers Full Instructions Preparation, Application & Recoat

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

PFL Glaze Sealer is a highly durable wet-look sealer, ideal for external concrete surfaces including paths and driveways.

Certi-Shine MicroStain FSR Diamond Polish Instructions

Section COATING RESTORATION

Jewel Stone. Decorative Concrete Overlay System. Part 1 GENERAL MANUFACTURER S SPECIFICATION

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Nutech Concrete Range

TECHNICAL DATA SHEET

Recommended Application Procedures

Thin-Set Troubleshooting Guide for Concrete and Masonry Substrates

TECHNICAL DATA SHEET

EVERLAST CONCRETE TECHNOLOGIES PROTECTION PRODUCTS SECTION CONCRETE ADDITIVES AND ADMIXTURES

Alkalinity Control Formula Primer PRODUCT DESCRIPTION. Reduces sweating of the concrete surface.

Seal- Krete High Performance System

RESURFACES PROPERLY PREPARED WEATHERED WOOD AND CONCRETE

For detailed product information, visit our DeckOver, Textured DeckOver or Extra Textured Deckover product pages.

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

(1:4) Heavy Duty, (1:9) ph Balancing (1:20) All Purpose Cleaner. (Power Cleaner: Water) Quart, 1 Gallon, 5 Gallon Pail, 55 Gallon Drum

Protective Industrial Polymers - USA Manufacturer s Specification

Section COATING RESTORATION

Measured in accordance with ASTM D 2697.

SECTION LITHIUM BASED MOISTURE VAPOR CONTROL CURE SYSTEM AND FINISHING

Measured in accordance with ASTM D 2697.

FORTEC % SOLIDS HIGH BUILD EPOXY COATING SYSTEM

MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE

Carboxane 950 Metallic

Thanks for purchasing ARTO high fired terracotta tiles, handmade in Southern California since 1966, and available both glazed and unglazed.

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Pentra -Guard (EXT) Exterior Surface Hardening and Protective Clear Coat PRODUCT DESCRIPTION

For routine cleaning of unpolished, honed or textured travertine using a cleaner and protector:

Industrial Sealers & Coatings

Specification and Installation

Pentra -Guard (EXT) Exterior Surface Hardening and Protective Clear Coat PRODUCT DESCRIPTION

Rust-Oleum Industrial Brands Specification

DAP WELDWOOD Nonflammable Contact Cement

DAP WELDWOOD Nonflammable Contact Cement

Property Test Method Typical Value

Product Specification

KOSTER AMERICAN CORPORATION

SECTION A. American Society for Testing and Materials (ASTM):

1/4 Industrial Trowel System

Complementary Coatings Insl-x. Stix Bonding Primer Introduction

KonCote Surface Overlay System - (Exterior Horizontal Surfaces) Manufacturer s Specifications A Surface Overlay System for Exterior Surfaces PART I -

INFORMATION. Product Information Sheet Regupol Resilient One Part Adhesive

NXT SUBSTRATE PREPARATION AND PRIMER GUIDE TDS 230N

Desco Granite Flooring Specifications

Lithium Densifier Concrete floor densifier, hardener and dust-proofer.

SECTION HYDRAULIC CEMENT UNDERLAYMENT

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

CARE & MAINTENANCE INITIAL CLEANING AND MAINTENANCE

S Pene- Krete (Spray- Applied)

ARDEX GUIDE SPECIFICATION ARDEX K 22 F High Flow, Fiber Reinforced, Self-Leveling Underlayment

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

SECTION HIGH PERFORMANCE COATINGS Ramuc Type EP Epoxy Updated October 5, 2015

Data Sheet Eco-Smart Membrane WS M1

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

DECORATIVE RE-IMAGINED CONCRETE FLOORS RESIDENTIAL COMMERCIAL

FLOOR STRIPPER LOW ODOR

Transcription:

Signature Seal 100 Medium-to-High Sheen Sealer - 100 VOC DESCRIPTION Legacy Signature Seal is a high-gloss, UV-resistant, lacquer-based, crystal-clear sealer. A light coating of Legacy Signature Seal will protect and enhance colored and textured concrete. Use Legacy Signature Seal on porous concrete to form a shield against stains and mildew. Legacy Signature Seal is a premium-quality nonyellowing, super-tough acrylic film that is easy to clean and maintain. Legacy Signature Seal protects with a high-gloss shine that penetrates the surface to retard efflorescence and resist oil, grease and food stains. Legacy Signature Seal virtually eliminates concrete dusting and is tough enough to withstand the extremes of areas subject to freezethaw. FEATURES Non-Yellowing, Crystal Clear Dries To A Wet-Look Finish Interior/Exterior Use Enhances Color 19% Solids Content USES Legacy Signature Seal can be used on interior or exterior concrete-type surfaces. Legacy Signature Seal can be used as a basecoat for interior applications where a compatible, commercial floor wax is planned as part of a maintenance program. Use on colored or uncolored, stamped or exposed aggregate concrete, or for use on BF resurfacing products. PACKAGING Legacy Signature Seal is available in one-gallon (3.785 L) and five-gallon (18.925 L) containers and fifty-five gallon (208.175 L) drums. COVERAGE Legacy Signature Seal will cover approximately 250 to 350 square feet per gallon (6.13-7.36 m2 / L) depending upon porosity of the surface. STORAGE Store in a dry, cool place and protect from freezing temperatures and moisture. Keep containers tightly sealed. Shelf life is approximately 36 months. CAUTIONS Contains aromatic hydrocarbons. KEEP OUT OF REACH OF CHILDREN. Before using or handling, read the Material Safety Data Sheet and Warranty. DO NOT TAKE INTERNALLY. Do not breathe vapors or mist. Use only with adequate ventilation and use a respirator when levels are above applicable limits. Avoid contact with skin and eyes. Close container after each use. Use good hygiene when handling this product and wash and bathe after each use. Be sure to wash clothing after each use. WARNING NOT RECOMMENDED for dense surfaces. Apply in thin coats, only on surfaces textured for slip resistance. If applied too heavily or applied to dense surfaces, the sealer may become slippery, especially in areas where water accumulates. If in doubt, test the surface by sprinkling with water. If water beads up on the surface, additional cleaning and profiling must be done. Do not use where hydrostatic pressure is possible. LIMITATIONS Legacy strongly recommends the use of a Moisture Vapor Evaporation Rate test in accordance with ASTM F1869. Results should not exceed 5 pounds per 1000 square feet per 24 hours based on the recommended test period. Relative humidity tests are strongly recommended as well when used in accordance with ASTM F2170. Results should not exceed 75%. Excessive moisture vapor evaporation rates can soften overlay materials and sealers, cause premature wear, discoloration and/or lead to a complete loss of bond from the concrete slab. Overlays and sealers should always be installed over ph neutral concrete substrates. PREPARATION Surface Preparation Guidelines for all Legacy Sealers Surface preparation is the most important process when using any topically applied product available from Legacy. Legacy follows the surface preparation techniques recommended by the International Concrete Repair Institute outlined in its Guideline No. 03732 Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, and Polymer Overlays. This Guideline is available at icri.org and Legacy highly recommends obtaining a copy and thoroughly familiarizing yourself with the various processes for accurately preparing concrete slabs.

Signature Seal 100 Medium-to-High Sheen Sealer - 100 VOC Unless noted in earlier sections of this Technical Data Sheet (TDS), the slab must be fully cured for this product to perform properly. Generally speaking, newly poured slabs must be at least 28 days old. The curing conditions including temperature and humidity have a dramatic effect on how fast or slow the slab cures. Cooler conditions will slow the curing process and these factors must be considered when determining whether a slab has adequately cured for the installation of this product. Surface preparation requirements are different for every slab and the installer must determine what process is appropriate for the slab they are working on. The recommended surface profile for Legacy sealers is a CSP 1 or CSP2 as defined by the Guideline 03732 mentioned above. The application area must be profiled and then thoroughly cleaned. All grease, oil, stains, stain residues, rust, sealers, waxes and the like must be completely removed prior to application of the product. The use of Legacy Etch-It, a mild etching and cleaning solution, followed by Legacy s Neutra- Clean and clean water rinses may be appropriate for the slab. Please refer to the TIS for these Legacy products for proper use. See also the Legacy Etch-It video online at www. legacycolor.com. Acid etching with Muriatic (Hydrochloric) Acid solutions may be appropriate for slabs that require more aggressive etching and cleaning. Solutions as light as 1:20 (acid:water) to as heavy as 1:1 may be necessary depending on the slab finish. When acid washing, it is very important to protect surrounding areas from damage. Plant and animal life, certain finishes on houses, metals, and the like can all be negatively impacted if acid solutions are not used responsibly. Be sure and wear proper personal protective equipment when acid washing. Always pre-wet slabs that are to be acid washed and always neutralize the slab with Legacy s Neutra Clean following the acid wash. Do not allow acid solutions to dry on the slab as dried residues will prevent the sealer from bonding. See for a video on How to Acid Wash Concrete. Other mechanical techniques such as grinding, scarifying, shotblasting or sandblasting may be necessary to prepare the slab. See www. legacycolor.com for other surface preparation techniques using mechanical methods. Old sealers and cure and seal products must be removed as well. Legacy s Eco-Strip is an alternative to mechanical methods for their removal. Please review the TIS for Strip It prior to using this product. The application area must be completely clean and free of grease, oils, dirt, rust, waxes, and organic stains. Mechanical removal of these may prove aesthetically displeasing. There are a number of stain and wax removers and enzymatic cleaners available either commercially or via the internet that work well in these situations. When using pressure washers to clean slabs, use equipment with a minimum of 3000 psi at 4 gallons per minute. Rotary floor scrubbers with black or red pads are effective for cleaning flat floors. When using rotary floor scrubbers on stamped slabs, nylon bristle brush attachments are necessary to reach imprinted areas effectively. Once the slab has been profiled, all contaminants and potential bond breakers removed, and thoroughly cleaned, allow the slab to complete dry prior to application of the product. NOTE: Legacy strongly recommends jobsite samples or mock ups with these products. Individuals who will be performing the work should test different sections of the concrete to determine suitability, coverage, coverage rates and final appearance. This product is not recommended for pre-sealed or dense surfaces such as glazed tile, marble or granite, dense brick, dense slate, or terrazzo. Dense, power trowelled concrete slabs MUST be properly profiled and cleaned for proper adhesion of this product. Properly prepared surfaces will readily absorb water. Water beading up or remaining on the surface indicates additional preparation and cleaning is required. Do not use this product where hydrostatic pressure is present.

Signature Seal 100 Medium-to-High Sheen Sealer - 100 VOC APPLICATION Apply in temperatures between 55º and 80ºF (12.8ºC and 26.7ºC). Always test a small area of surface to verify protection and appearance. Use Legacy Signature Seal full strength. DO NOT THIN. Apply from 2-3 light, even coats with a low-pressure airless sprayer or pump up sprayer resistant to acetone. CAUTION: if using a roller to apply sealer, be careful to apply in thin coats, maintain a wet edge, and do not back-brush. Allow 1-3 hours between coats or until the surface is dry to the touch. Avoid using in direct sunlight, especially on hot, windy days. Apply during the cooler part of the day when the surface is shaded. Do not apply on rainy or foggy days. Excess moisture will not allow the sealer to dry properly. Use only in well ventilated areas. It is recommended that foot traffic remain off the finished sealed surface for 24 hours. For heavy traffic, allow 72 hours for curing. HELPFUL HINT: Use toluene or lacquer thinner for easy cleanup. Note: When installing Signature Seal 100 over Signature Seal 400, apply in multiple, thin applications with a sprayer to acheive 100% coverage. Important! Do NOT apply Signature Seal 100 over Signature Seal 400 when the slab is hot. Apply in the morning hours when the slab is cool. MAINTENANCE The sealed surface should be inspected periodically for areas of thin or traffic-worn sealer. Legacy recommends the application of Legacy Floor Wax as a sacrificial coating on interior surfaces. Reapply as needed, according to the appropriate Technical Data Sheet. If traces of efflorescence are present, this should first be eliminated with a gentle cleaner such as Legacy Etch- It, according to the Legacy Etch-It Technical Data Sheet. WARRANTY This product is not intended for public use and is intended for use by licensed contractors and installers, experienced and trained in the use of these products. It is warranted to be of uniform quality, within manufacturing tolerances. The manufacturer has no control over the use of this product, therefore, no warranty, expressed or implied, is or can be made either as to the effects or results of such use. In any case, the manufacturer s obligations shall be limited to refunding the purchase price or replacing material proven defective. The end user shall be responsible for determining product s suitability and assumes all risks and liability. PLAN SPECIFICATION Legacy Signature Seal Suggested Short Form Specification: All concrete flatwork designated as being sealed in the plans and specifications shall be sealed with 2-3 light even coats of Legacy Signature Seal, at the rate of approximately 250 to 300 square feet per gallon (6.13-7.36 m2 / L), manufactured by Legacy, MANUFACTURER Legacy,

Signature Seal 400 Medium-to-High Sheen Sealer - 400 VOC DESCRIPTION Legacy Signature Seal is a high-gloss, UV-resistant, lacquer-based, crystal-clear sealer. A light coating of Legacy Signature Seal will protect and enhance colored and textured concrete. Use Legacy Signature Seal on porous concrete to form a shield against stains and mildew. Legacy Signature Seal is a premium-quality nonyellowing, super-tough acrylic film that is easy to clean and maintain. Legacy Signature Seal protects with a high-gloss shine that penetrates the surface to retard efflorescence and resist oil, grease and food stains. Legacy Signature Seal virtually eliminates concrete dusting and is tough enough to withstand the extremes of areas subject to freezethaw. FEATURES Non-Yellowing, Crystal Clear Dries To A Wet-Look Finish Interior/Exterior Use Enhances Color 19% Solids Content USES Legacy Signature Seal can be used on interior or exterior concrete-type surfaces. Legacy Signature Seal can be used as a basecoat for interior applications where a compatible, commercial floor wax is planned as part of a maintenance program. Use on colored or uncolored, stamped or exposed aggregate concrete, or for use on BF resurfacing products. PACKAGING Legacy Signature Seal is available in one-gallon (3.785 L) and five-gallon (18.925 L) containers and fifty-five gallon (208.175 L) drums. COVERAGE Legacy Signature Seal will cover approximately 250 to 350 square feet per gallon (6.13-7.36 m2 / L) depending upon porosity of the surface. STORAGE Store in a dry, cool place and protect from freezing temperatures and moisture. Keep containers tightly sealed. Shelf life is approximately 36 months. CAUTIONS Contains aromatic hydrocarbons. KEEP OUT OF REACH OF CHILDREN. Before using or handling, read the Material Safety Data Sheet and Warranty. DO NOT TAKE INTERNALLY. Do not breathe vapors or mist. Use only with adequate ventilation and use a respirator when levels are above applicable limits. Avoid contact with skin and eyes. Close container after each use. Use good hygiene when handling this product and wash and bathe after each use. Be sure to wash clothing after each use. WARNING NOT RECOMMENDED for dense surfaces. Apply in thin coats, only on surfaces textured for slip resistance. If applied too heavily or applied to dense surfaces, the sealer may become slippery, especially in areas where water accumulates. If in doubt, test the surface by sprinkling with water. If water beads up on the surface, additional cleaning and profiling must be done. Do not use where hydrostatic pressure is possible. LIMITATIONS Legacy strongly recommends the use of a Moisture Vapor Evaporation Rate test in accordance with ASTM F1869. Results should not exceed 5 pounds per 1000 square feet per 24 hours based on the recommended test period. Relative humidity tests are strongly recommended as well when used in accordance with ASTM F2170. Results should not exceed 75%. Excessive moisture vapor evaporation rates can soften overlay materials and sealers, cause premature wear, discoloration and/or lead to a complete loss of bond from the concrete slab. Overlays and sealers should always be installed over ph neutral concrete substrates. PREPARATION Surface Preparation Guidelines for all Legacy Sealers Surface preparation is the most important process when using any topically applied product available from Legacy. Legacy follows the surface preparation techniques recommended by the International Concrete Repair Institute outlined in its Guideline No. 03732 Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, and Polymer Overlays. This Guideline is available at icri.org and Legacy highly recommends obtaining a copy and thoroughly familiarizing yourself with the various processes for accurately preparing concrete slabs.

Signature Seal 400 Medium-to-High Sheen Sealer - 400 VOC Unless noted in earlier sections of this Technical Data Sheet (TDS), the slab must be fully cured for this product to perform properly. Generally speaking, newly poured slabs must be at least 28 days old. The curing conditions including temperature and humidity have a dramatic effect on how fast or slow the slab cures. Cooler conditions will slow the curing process and these factors must be considered when determining whether a slab has adequately cured for the installation of this product. Surface preparation requirements are different for every slab and the installer must determine what process is appropriate for the slab they are working on. The recommended surface profile for Legacy sealers is a CSP 1 or CSP2 as defined by the Guideline 03732 mentioned above. The application area must be profiled and then thoroughly cleaned. All grease, oil, stains, stain residues, rust, sealers, waxes and the like must be completely removed prior to application of the product. The use of Legacy Etch-It, a mild etching and cleaning solution, followed by Legacy s Neutra- Clean and clean water rinses may be appropriate for the slab. Please refer to the TIS for these Legacy products for proper use. See also the Legacy Etch-It video online at www. legacycolor.com. Acid etching with Muriatic (Hydrochloric) Acid solutions may be appropriate for slabs that require more aggressive etching and cleaning. Solutions as light as 1:20 (acid:water) to as heavy as 1:1 may be necessary depending on the slab finish. When acid washing, it is very important to protect surrounding areas from damage. Plant and animal life, certain finishes on houses, metals, and the like can all be negatively impacted if acid solutions are not used responsibly. Be sure and wear proper personal protective equipment when acid washing. Always pre-wet slabs that are to be acid washed and always neutralize the slab with Legacy s Neutra Clean following the acid wash. Do not allow acid solutions to dry on the slab as dried residues will prevent the sealer from bonding. See for a video on How to Acid Wash Concrete. Other mechanical techniques such as grinding, scarifying, shotblasting or sandblasting may be necessary to prepare the slab. See www. legacycolor.com for other surface preparation techniques using mechanical methods. Old sealers and cure and seal products must be removed as well. Legacy s Eco-Strip is an alternative to mechanical methods for their removal. Please review the TIS for Strip It prior to using this product. The application area must be completely clean and free of grease, oils, dirt, rust, waxes, and organic stains. Mechanical removal of these may prove aesthetically displeasing. There are a number of stain and wax removers and enzymatic cleaners available either commercially or via the internet that work well in these situations. When using pressure washers to clean slabs, use equipment with a minimum of 3000 psi at 4 gallons per minute. Rotary floor scrubbers with black or red pads are effective for cleaning flat floors. When using rotary floor scrubbers on stamped slabs, nylon bristle brush attachments are necessary to reach imprinted areas effectively. Once the slab has been profiled, all contaminants and potential bond breakers removed, and thoroughly cleaned, allow the slab to complete dry prior to application of the product. NOTE: Legacy strongly recommends jobsite samples or mock ups with these products. Individuals who will be performing the work should test different sections of the concrete to determine suitability, coverage, coverage rates and final appearance. This product is not recommended for pre-sealed or dense surfaces such as glazed tile, marble or granite, dense brick, dense slate, or terrazzo. Dense, power trowelled concrete slabs MUST be properly profiled and cleaned for proper adhesion of this product. Properly prepared surfaces will readily absorb water. Water beading up or remaining on the surface indicates additional preparation and cleaning is required. Do not use this product where hydrostatic pressure is present.

Signature Seal 400 Medium-to-High Sheen Sealer - 400 VOC APPLICATION Apply in temperatures between 55º and 80ºF (12.8ºC and 26.7ºC). Always test a small area of surface to verify protection and appearance. Use Legacy Signature Seal full strength. DO NOT THIN. Apply from 2-3 light, even coats with a low-pressure airless sprayer or pump up sprayer resistant to acetone. CAUTION: if using a roller to apply sealer, be careful to apply in thin coats, maintain a wet edge, and do not back-brush. Allow 1-3 hours between coats or until the surface is dry to the touch. Avoid using in direct sunlight, especially on hot, windy days. Apply during the cooler part of the day when the surface is shaded. Do not apply on rainy or foggy days. Excess moisture will not allow the sealer to dry properly. Use only in well ventilated areas. It is recommended that foot traffic remain off the finished sealed surface for 24 hours. For heavy traffic, allow 72 hours for curing. HELPFUL HINT: Use toluene or lacquer thinner for easy cleanup. MAINTENANCE The sealed surface should be inspected periodically for areas of thin or traffic-worn sealer. Legacy recommends the application of Legacy Floor Wax as a sacrificial coating on interior surfaces. Reapply as needed, according to the appropriate Technical Data Sheet. If traces of efflorescence are present, this should first be eliminated with a gentle cleaner such as Legacy Etch- It, according to the Legacy Etch-It Technical Data Sheet. WARRANTY This product is not intended for public use and is intended for use by licensed contractors and installers, experienced and trained in the use of these products. It is warranted to be of uniform quality, within manufacturing tolerances. The manufacturer has no control over the use of this product, therefore, no warranty, expressed or implied, is or can be made either as to the effects or results of such use. In any case, the manufacturer s obligations shall be limited to refunding the purchase price or replacing material proven defective. The end user shall be responsible for determining product s suitability and assumes all risks and liability. PLAN SPECIFICATION Legacy Signature Seal Suggested Short Form Specification: All concrete flatwork designated as being sealed in the plans and specifications shall be sealed with 2-3 light even coats of Legacy Signature Seal, at the rate of approximately 250 to 300 square feet per gallon (6.13-7.36 m2 / L), manufactured by Legacy, MANUFACTURER Legacy,

Signature Seal 650 Medium-to-High Sheen Sealer - 650 VOC DESCRIPTION Legacy Signature Seal 650 is a premium-quality nonyellowing, UV-resistant, super-tough acrylic film that is easy to clean and maintain. Legacy Signature Seal 650 protects with a medium-tohigh gloss shine that penetrates the surface to retard efflorescence and resist oil, grease and food stains. Legacy Signature Seal 650 virtually eliminates concrete dusting and is tough enough to withstand the extremes of areas subject to freezethaw. FEATURES Non-Yellowing, Crystal Clear Dries to a Medium-to-High Sheen Finish Interior/Exterior Use Enhances Color 19% Solids Content USES Legacy Signature Seal 650 can be used on interior or exterior masonry, and concrete-type surfaces. Legacy Signature Seal 650 can be used as a base-coat for interior applications where a compatible, commercial floor wax is planned as part of a maintenance program. Use on colored or uncolored, stamped or exposed aggregate concrete, porous brick, natural and manufactured stone, stucco, slate, unglazed tile and flagstone. PACKAGING Legacy Signature Seal 650 is available in one-gallon (3.785 L) and five-gallon (18.92 L) cans. COVERAGE Legacy Signature Seal 650 covers approximately 250 to 300 square feet per gallon (6.13-7.36 m2 / L) depending upon porosity of the surface. STORAGE Store in a safe place. Keep containers tightly sealed. Shelf life is approximately 36 months. CAUTIONS Contains Aromatic Hydrocarbons. KEEP OUT OF REACH OF CHILDREN. Before using or handling, read the Material Safety Data Sheet and Warranty. DO NOT TAKE INTERNALLY. Do not breathe vapors or mist. Use only with adequate ventilation and use a respirator when levels are above applicable limits. Avoid contact with skin and eyes. Close container after each use. Use good hygiene when handling this product and wash and bathe after each use. Be sure to wash clothing after each use. WARNING IT IS ILLEGAL TO USE THIS PRODUCT IN THE STATE OF CALIFORNIA. OTHER STATES MAY ALSO HAVE SIMILAR RESTRICTIONS. CHECK WITH YOUR LOCAL REGULATORY AGENCY. NOT RECOMMENDED for dense surfaces. Apply in thin coats, only on surfaces textured for slip resistance. If applied too heavily or applied to dense surfaces, the sealer may become slippery, especially in areas where water accumulates. Heavy application may also result in bubbling and coating imperfections. If in doubt about penetrability, test the surface by sprinkling with water. If water beads up on the surface, additional cleaning and testing must be done. Do not use where hydrostatic pressure is present. PREPARATION Surface Preparation Guidelines for all Legacy Sealers Surface preparation is the most important process when using any topically applied product available from Legacy. Legacy follows the surface preparation techniques recommended by the International Concrete Repair Institute outlined in its Guideline No. 03732 Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, and Polymer Overlays. This Guideline is available at icri.org and Legacy highly recommends obtaining a copy and thoroughly familiarizing yourself with the various processes for accurately preparing concrete slabs. Unless noted in earlier sections of this Technical Data Sheet (TDS), the slab must be fully cured for this product to perform properly. Generally speaking, newly poured slabs must be at least 28 days old. The curing conditions including temperature and humidity have a dramatic effect on how fast or slow the slab cures. Cooler conditions will slow the curing process and these factors must be considered when determining whether a slab has adequately cured for the installation of this product.

Signature Seal 650 Medium-to-High Sheen Sealer - 650 VOC Surface preparation requirements are different for every slab and the installer must determine what process is appropriate for the slab they are working on. The recommended surface profile for Legacy sealers is a CSP 1 or CSP2 as defined by the Guideline 03732 mentioned above. The application area must be profiled and then thoroughly cleaned. All grease, oil, stains, stain residues, rust, sealers, waxes and the like must be completely removed prior to application of the product. The use of Legacy Etch-It, a mild etching and cleaning solution, followed by Legacy s Neutra- Clean and clean water rinses may be appropriate for the slab. Please refer to the TDS for these Legacy products for proper use. Acid etching with Muriatic (Hydrochloric) Acid solutions may be appropriate for slabs that require more aggressive etching and cleaning. Solutions as light as 1:20 (acid:water) to as heavy as 1:1 may be necessary depending on the slab finish. When acid washing, it is very important to protect surrounding areas from damage. Plant and animal life, certain finishes on houses, metals, and the like can all be negatively impacted if acid solutions are not used responsibly. Be sure and wear proper personal protective equipment when acid washing. Always pre-wet slabs that are to be acid washed and always neutralize the slab with Legacy s Neutra Clean following the acid wash. Do not allow acid solutions to dry on the slab as dried residues will prevent the sealer from bonding. Other mechanical techniques such as grinding, scarifying, shotblasting or sandblasting may be necessary to prepare the slab. See www. LegacyColor.com for other surface preparation techniques using mechanical methods. Old sealers and cure and seal products must be removed as well. Legacy s Eco-Strip is an alternative to mechanical methods for their removal. Please review the TDS for Eco-Strip prior to using this product. The application area must be completely clean and free of grease, oils, dirt, rust, waxes, and organic stains. Mechanical removal of these may prove aesthetically displeasing. There are a number of stain and wax removers and enzymatic cleaners available either commercially or via the internet that work well in these situations. When using pressure washers to clean slabs, use equipment with a minimum of 3000 psi at 4 gallons per minute. Rotary floor scrubbers with black or red pads are effective for cleaning flat floors. When using rotary floor scrubbers on stamped slabs, nylon bristle brush attachments are necessary to reach imprinted areas effectively. Once the slab has been profiled, all contaminants and potential bond breakers removed, and thoroughly cleaned, allow the slab to complete dry prior to application of the product. NOTE: Legacy strongly recommends jobsite samples or mock ups with these products. Individuals who will be performing the work should test different sections of the concrete to determine suitability, coverage, coverage rates and final appearance. This product is not recommended for pre-sealed or dense surfaces such as glazed tile, marble or granite, dense brick, dense slate, or terrazzo. Dense, power trowelled concrete slabs MUST be properly profiled and cleaned for proper adhesion of this product. Properly prepared surfaces will readily absorb water. Water beading up or remaining on the surface indicates additional preparation and cleaning is required. Do not use this product where hydrostatic pressure is present. LIMITATIONS Legacy strongly recommends the use of a Moisture Vapor Evaporation Rate test in accordance with ASTM F1869. Results should not exceed 5 pounds per 1000 square feet per 24 hours based on the recommended test period. Relative humidity tests are strongly recommended as well when used in accordance with ASTM F2170. Results should not exceed 75%. Excessive moisture vapor evaporation rates can soften overlay materials and sealers, cause premature wear, discoloration and/or lead to a complete loss of bond from the concrete slab. Overlays and sealers should always be installed over ph neutral concrete substrates.

Signature Seal 650 Medium-to-High Sheen Sealer - 650 VOC APPLICATION Always test a small area of surface to verify protection and appearance. Use Legacy Signature Seal 650 full strength. DO NOT THIN. Apply from 2-3 light, even coats (depending on porosity of surface) with a short-napped roller or a sprayer with neoprene seals and hose. Allow 1-3 hours between coats or until the surface is dry to the touch. Apply in temperatures between 55ºF and 80ºF (12.8ºC and 26.7ºC). Avoid using in direct sunlight, especially on hot, windy days. Apply during the cooler part of the day when the surface is shaded. Do not apply on rainy or foggy days. Excess moisture will not allow the sealer to dry properly. Use only in well ventilated areas. It is recommended that foot traffic remain off the finished sealed surface for 24 hours. For heavy traffic, allow 72 hours for curing. HELPFUL HINT: Use xylene for easy cleanup immediately after use. MAINTENANCE The sealed surface should be inspected periodically for areas of thin or traffic-worn sealer. Legacy recommends the application of Legacy Floor Wax as a sacrificial coating on interior surfaces. Reapply as needed, according to the appropriate Technical Data Sheet. If traces of efflorescence are present, this should first be eliminated with a gentle cleaner such as Legacy Etch- It, according to the Legacy Etch-It Technical Data Sheet. WARRANTY This product is not intended for public use and is intended for use by licensed contractors and installers, experienced and trained in the use of these products. It is warranted to be of uniform quality, within manufacturing tolerances. The manufacturer has no control over the use of this product, therefore, no warranty, expressed or implied, is or can be made either as to the effects or results of such use. In any case, the manufacturer s obligations shall be limited to refunding the purchase price or replacing material proven defective. The end user shall be responsible for determining product s suitability and assumes all risks and liability. PLAN SPECIFICATION Legacy Signature Seal Suggested Short Form Specification: All concrete flatwork designated as being sealed in the plans and specifications shall be sealed with 2-3 light even coats of Legacy Signature Seal, at the rate of approximately 250 to 300 square feet per gallon (6.13-7.36 m2 / L), manufactured by Legacy, MANUFACTURER Legacy,