Prepacked, Disposable Büchner Funnels for Medicinal Chemistry

Similar documents
METHOD 3610B ALUMINA CLEANUP

DECEMBER Silica Alumina Reversed-phase C-18 Specialty. Columns. RediSep. Speed Productivity Reliability

VARIAN, INC. Flash Chromatography

SPE in Disk Format. Experimental. Table 1 Comparison of Typical SPE Cartridge and Empore Disk

Extraction Products Separator Paper 188 Solid Phase Extraction (SPE) 189 Extraction Thimbles 192. Extraction Products

Adsorptive and Mechanical Mechanisms of Fluid Purification Using Charge Modified Depth Filtration Media. Dr. Robert Conway, Ph.D.

EVOLUTE ABN SPE Columns for Solid Phase Extraction of Environmental Samples

Sample Prep - Solid Phase Extraction

Analytical Method for aldrin, endrin and dieldrin (Targeted to Agricultural, Animal and Fishery Products)

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

Ensure high performance chromatography by using particle free mobile phases and sample solutions

Crystallization & Filtration

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

2. Crystallization. A. Background

FastPure Spin Columns (Mini and Midi)

Empore. Solid Phase Extraction Cartridges. Technical Information. Product Description. Product Characteristics. Sorbents Available

Welchrom Solid Phase Extration

Dynamic High Capacity Mustang Q Membrane Units for Scaleable Anion Exchange Chromatography Purification of Adenoviral Vectors

MACHEREY-NAGEL. CHROMABOND Flash cartridges. Chromatography. Solutions for preparative purifications. n Resolution n Quality n Safety.

Experimental. Instrumentation

order:

3 Empore. High Performance Extraction Disk Cartridges October Answers to Frequently Asked Questions. Product Description

Liners and consumables for OPTIC Inlet. Liner Selection Guide

MACHEREY-NAGEL. CHROMABOND Flash cartridges. Chromatography. Solutions for preparative purifications. n Resolution n Quality n Safety.

Inertsil ODS-3 2 µm. Base Silica Physical Properties and Chemical Modification. Base Silica: High Purity Silica Gel % Surface Area: 450 m 2 /g

Investigating the Extraction Efficiency of Dioxins in Several Types of Aqueous Matrices by Automated Solid Phase Extraction Utilizing Disks

Sepax Technologies, Inc.

Get Your Fill. A full line of empty chromatography columns and accessories. Protein Purification

Effective Scaling of Preparative Separations Using Axial Compression Columns

Qualitative Filter Papers

ProteIndex Chemical-Tolerant Ni-Penta Agarose. Prepacked Cartridge. 6 FF Prepacked Cartridge, 5 x 1 ml settled resin

Dynamic Axial compression Liquid Chromatography Columns. Flash MPLC HPLC UHPLC. Proven, scalable technology for classic purification techniques

Martin Gilar Waters Corporation, Milford, MA, U.S. Origins of synthetic oligonucleotides impurities. Lab-scale isolation options

Nuvia cprime Hydrophobic Cation Exchange Media

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

Filtration Products. Best Value Guaranteed Product Quality Innovation to Benefit Customers

Standard Operating Procedure for the Sampling and Analysis of Total Suspended Solids in Great Lakes Waters

CLEAN SCREEN FASt FILTER AND SHOOT UCT FORENSICS. CLEAN SCREEN FASt SPE COLUMNS

2. Crystallization. A. Background

Hamilton PRP Polymeric Columns

Preparative, Pilot & Process Columns

Product Guide for LudgerClean TM D1. Glycan Cleanup Cartridges

Introducing the SNAP Column:

Capillary GC Troubleshooting: a Practical Approach

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Air monitoring around the world.

7 Preparative Columns

Separation of Monoclonal Antibodies Using TSKgel HPLC Columns

MPLC. Simply Efficient! Watchers Flash Flash Chromatography by ISU. Ver

Experiment 3: Determination of an Empirical Formula

5.3: FILTRATION NOOR MUHAMMAD SYAHRIN BIN YAHYA

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

SpeedExtractor E-916 Determination of Total Petroleum Hydrocarbons in Soil, Sediment, and Waste Samples using the SpeedExtractor E /2009

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

High Throughput Sub-4 Minute Separation of Antibodies using Size Exclusion Chromatography

Lecture No. (7) Rubber Fillers

UNOsphere Q & S Ion Exchange Media. Instruction Manual ...

SiliaMetS RAPID & RELIABLE ADSORPTION PROCESSING. Process Scale Adsorbent Cartridges for Pharmaceutical Purification

Module 16: Gel filtration: Principle, Methodology & applications. Dr. Savita Yadav Professor Department of Biophysics AIIMS, New Delhi

FILTERS (GLASS FIBER)

SINTERED WIRE MESH.

ProSep Ultra Plus Chromatography Media

Rapid Determination of Drug Protein Binding Affinity using Solid Phase Microextraction

Performance. Reliability. Productivity. Consumables

Gregory J. Carroll U.S. Environmental Protection Agency Risk Reduction Engineering Laboratoty Cincinnati, OH

A method to pack Agilent Prep C18 Media on Load & Lock Column

Sample Prep Parts. Solid-Liquid Separation Expert

Production of FITC conjugate

Column Packing of Cellufine A-500 ion exchange chromatography resin

CLAY MODULES FOR PROJECT-BASED LEARNING THE PROCESSING AND TESTING OF CERAMIC WATER FILTERS John OBAYEMI, Pierre-Marie NIGAY and Wole SOBOYEJO

Agilent MetaCarb 87H Organic Acids Column H + Form User Manual Part No. A5214

Sixth Edition. Normal Phase Silica Alumina Reversed-phase C18 High Performance Specialty Bulk Silica. Consumables. Speed. Productivity.

Product Guide for LudgerSep TM N2 High Resolution Amide HPLC Columns for Glycan Analysis

ChromPure TM Syringe Filter

Preparation. Sample. Extraction Glassware Liquid/Liquid Extraction SUPELCO

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

Nuvia S and Q High-Capacity Ion Exchange Media Instruction Manual

Eurovacuum EVM Series

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

Thermo Scientific MAbPac HIC Columns. Novel Hydrophobic Interaction HPLC Columns. Designed for Monoclonal Antibody Analysis

Membranes for Industrial Applications. Claudia Staudt, GMM/M BASF SE Ludwigshafen

Paper type solvent filter Cartridge type solvent filter In-line filter. Uniform fiber diameter of 1 µm. Minimized deviation in particle size.


Experiment 3: The Chromatography of Organic Compounds

MERCAPTANS, METHYL-, ETHYL-, and n-butyl- 2542

Crossflow Filtration for Ink Jet Fluids

1. Low profile units 2 Normal profile sterilisation filter units 3. Each pack includes 12 glass-fibre prefilters

EVOLUTE ABN FOR EXTRACTION OF DRUGS FROM BIOLOGICAL FLUIDS

Optimizing the Purification of a Standard Chiral Compound Utilizing a Benchtop, Multi-Purpose, Semi-Preparative to Preparative HPLC System

COLIFORM FILTERS. All filters listed on this page are white with black grids, 47 mm diameter, sterile.

Column Packing of Cellufine Sulfate

Optimizing Purified Sample Recovery on Reverse-Phase HPLC Systems

G Sep Size Exclusion Columns

Broader Adoption of SPE in Environmental Applications Enabled by Selective SPE Chemistries. Kory Kelly and Allen Misa

Simple Techniques for Improving the Isolation of Synthetic Peptides Jo-Ann Jablonski Principal Scientist Waters Corporation

Maximizing Sample Recovery on the ACCQPrep HP125

The Selectivity Company. YMC Glass Columns. For Laboratory Scale Applications. Biocompatible Self-packing Easy Handling.

ISO INTERNATIONAL STANDARD. Determination of the viscosity of polymers in dilute solution using capillary viscometers

HiTrap Heparin HP, 1 ml and 5 ml

EXTRACTION OF BIOLOGICAL TISSUES FOR AROMATIC AND CHLORINATED HYDROCARBONS

Transcription:

Prepacked, Disposable Büchner Funnels for Medicinal Chemistry An Trinh, Todd Williams, Dave Bell, and Michael Ye Supelco, 595 North Harrison Road, Bellefonte, PA 16823 T404044 GUR

Abstract/Introduction Medicinal chemistry is a branch within the pharmaceutical industry that merges expertise in organic, analytical, computational chemistry, and drug metabolism to conceptualize, design, and create novel compounds for potential therapeutic use. Within this research, Flash and HPLC chromatography play a growing role in purifying and characterizing pharmaceutical candidates for further biological evaluation. Nevertheless, medicinal chemists are searching yet for simple, reliable, rapid, low-cost methods of achieving separations for a wide range of reaction scales. As a result, packed bed Büchner funnels have received mainstream commission as a simple alternative to flash and other purification techniques.

Abstract/Introduction (contd) Unlike their self-packed ceramic counterpart, the pre-packed disposable version offers both performance and safety benefits. For example, researchers are exposed to inhalable particulates during the packing process, and large amounts of solvents used to clean the Büchner funnels after use. Also, ceramic Büchner funnels can easily break during use and cleaning. In terms of performance, channeling and bed-weight inconsistency are also major problems when researchers are required to self-pack Büchner funnels. In this report, we will discuss how prepacked disposable Büchner funnels address these issues as well as provide an overview of their utility within the area of medicinal chemistry research.

Experimentation Pre-Packed Disposable Büchner Funnel Design (Figure A) 2-piece polypropylene construction Internal Diameter: 55-110mm ID Bed weight ranges between 12.5-200g (Table 1) Lower half is the funnel Upper half is packed with sorbent between two 20µm polyethylene frits Resistant to organic solvents Contains a heat sealed retaining ring to further compress sorbent-frit assembly in place This compression helps eliminate sorbent channeling during use

Figure A. Schematic of Pre-Packed Büchner Funnels Retaining Ring Top Frit Sorbent Bed Bottom Frit

Table 1. Bed Weight Distribution vs. Funnel ID Funnel ID Sorbent Weight (Silica) 55mm 12.5g 70mm 25g 90mm 50g 110mm 100g 190mm 200g

Common Uses for Packed Bed Büchner Funnels Silica sorbents often used in baseline clean-up of solution-phase synthesis reactions Normal-Phase chromatography used to retard/retain more polar compounds via polar-polar interaction when loaded in the presence of organic sample matrix Polyamide phases (DPA-6S) commonly used for isolating active compounds from natural products (plant extracts) Other applications include dessication (solvent dehydration) and filtration (particulate removal) Scale-up SPE methods as tool for gross purification Tables 2 & 3 list common Büchner funnel sorbents and applications

Table 2. Common Büchner Funnel Sorbents Sorbent Composition Particle Size Magnesium sulfate MgSO 4 Silica (Merck) SiO 4 choices Silica (Discovery) SiO 4 40-60µm Celite 545 AW diatomaceous earth Alumina A, B, or N Al 2 O 3 60/325 mesh Florisil Mg 2 SiO 4 100/120 mesh Charcoal C (act. coconut) 20/40 mesh DPA-6S Polyamide resin 50-160µm C18-silica octadecyl 40-60µm

Table 3. Common Büchner Funnel Applications Sorbent Magnesium sulfate Silica Celite 545AW Alumina A, B, N Florisil Charcoal Polyamide C18-silica Application Dessicant Filtration, polar compound removal, dessicant Filtration Dessicant, many specific applications Many specific applications Removal of non-polar compounds removal, pigments, dyes Isolation of tannins, chlorophyll, gallic, humic acids Non-polar compound removal

Capacity Test for Büchner Funnels Packed bed Büchner funnels are most often used for gross purification/sample clean-up of larger scale samples. As a result, breakthrough capacity is a common concern for such applications. Representative test compounds were loaded at increasing amounts onto 5 common sorbents packed into 55mm ID funnels preconditioned with the appropriate solvent. The load flow through eluate was analyzed for compound breakthrough via HPLC-UV analysis.

Addition of Small Porosity Glass Fiber Membranes From the initial capacity experiment, fines were discovered in the flow-through eluate. To reduce the fines content, a glass fiber membrane, 0.45µm (Whatman GF/F), was placed below the bottom PE frit to trap any fines during sample processing In this study, 4 x 100mL aliquots of DI H 2 O was passed through a 55mm celite Büchner Funnel containing the small porosity GF/F membrane. Flow rate was measured during process, and the eluate was analyzed for celite fines.

Results Capacity Tests for Büchner Funnels On average, capacity levels of ~3.0% bed weight was observed (Table 4) The compression packing yielded fines in the flow-through solutions; however, fines can be adequately removed via thorough conditioning prior to addition of the sample Addition of a glass fiber membrane below the bottom frit may offer a potential solution for reducing fines

Table 4. Büchner Funnel Capacity and Breakthrough Values Phase Bed Wgt. Analyte Matrix Sample Capacity (mg) 2% BKT* DPA-6S 10g Phloroglucinol Water:Methanol (90:10) 240 DSC-Si 12.5g 4-Fluoro-3-nitrobenzoic acid Methylene chloride 350 Merck Silica 12.5g 4-Fluoro-3-nitrobenzoic acid Methylene chloride 400 Celite 12.5g Butyl paraben Methylene chloride 80 Charcoal 12.5g Butyl paraben Water:Methanol (80:20) 104 *Breakthrough is positive for the aliquot with a peak area greater than 2% that of breakthrough standard solution.

Addition of Small Porosity Glass Fiber Membranes The purpose of this study was to reduce the level of fines found in the eluate during processing. A fine porosity glass fiber membrane (0.45µm, Whatman GF/F) was placed below the bottom PE frit of a 55mm ID celite Büchner funnel prior to processing. The addition of the fine porosity GF membrane adequately trapped fine particles during processing; however, flow rate was impeded as more fines were trapped by the filter membrane (Figure B).

Figure B. Flow Rate Comparison of 55mm ID Büchner Funnel With and Without Glass Fiber Membrane Filtration Time vs. Volume 200 150 Time (sec) 100 50 Celite Celite GF/F 0 #1 #2 #3 #4 100mL Water Filtration

Conclusion Prepacked to eliminate exposure to inhalable particulates Compressed sorbent bed eliminates channeling Porous frit helps to spread sample across the sorbent bed Prepackaged design saves time in packing, cleaning and disposal Fines can be adequately removed through thorough conditioning before sample addition Addition of glass fiber membrane adequately captures fines; however, flow rate is reduced