ADDENDUM NUMBER FOUR TO THE PLANS AND SPECIFICATIONS

Similar documents
JEFFERSON PARISH SHERIF S OFFICE

CARPENTER TRADE REGULATION

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Edge Grinding: Safety vs. Aesthetics. Fall Conference. Las Vegas, NV September 11, 2018

Edge Grinding: Safety vs. Aesthetics. Fall Conference Las Vegas, NV September 11, /24/2018

A. Remove Table of Contents and insert new attached Table of Contents.

Proposed List of development and architectural standards to be amended

LEED Reference Guide for Green Building Operations and Maintenance For the Operations and Maintenance of Commercial and Institutional Buildings 2009

ALBUQUERQUE PUBLIC SCHOOLS for MONTESSORI OF THE RIO GRANDE CHARTER SCHOOL

Repair Maintenance Hangar Phase II August 2010

FOXMOOR ASSOCIATION, INC.

HURON PUBLIC WORKS BUILDING HURON, SOUTH DAKOTA BID NO R

NMHU STUDENT UNION BUILDING STUDIO SW PROJECT NO 0918

4.1.3 Project Manual

MANUFACTURER S SPECIFICATION

City of Miami ADDENDUM NO. 5. January 12, 2017 INVITATION TO BID NO.: CURTIS PARK NEW SWIMMING POOL FACILITY

ADDENDUM TO THE CONTRACT. for the. Glacier Fire Station Roof Replacement Contract No. BE18-074

SHERIDAN SEATING INC.

JE Berkowitz, L.P. Architectural Glazing Guide Specification for Enviroscreen Silk-Screened Glass

08620 UNIT SKYLIGHTS Tufflite double polycarbonate glazed Frb

Rytec Corporation One Cedar Parkway Jackson, WI GO-RYTEC (262)

Expansion Joint Covers

SECTION EXPANSION CONTROL

NOTICE TO BIDDERS OF RECORD

SUBSTITUTION REQUEST (After the Bidding/Negotiating Phase)

SECTION THERMAL INSULATION

SECTION BASIC ELECTRICAL REQUIREMENTS

April 25, ADDENDUM NO. 2 This Addendum and attachments consists of: 17-Pages. ITB Turnagain Elementary School Interior Upgrades

STATE UNIVERSITY CONSTRUCTION FUND

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

Fences. Facts to Know

ADDENDUM NO Refer to Specifications Section Alternates. Clarifications to alternate descriptions are as follows:

SECTION The specification section is organized by placing information in three standard parts:

Hillsborough City School District Window Covering Projects At 6 District Sites. Bid #19-01 ADDENDUM NO. 1

SECTION EXPANSION CONTROL

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

SECTION GLAZING

CHAPTER 4 INTEGRITY WOOD ULTREX GLIDER

REQUEST FOR PROPOSAL FOR DEVELOPMENT OF CITY-OWNED PROPERTY WITHIN THE BAYBORO HARBOR COMMUNITY REDEVELOPMENT AREA

ADDENDUM #9 DATE: 1/12/17 TO:

REVISED BID FORM WILLIAM PATERSON UNIVERSITY OF NEW JERSEY. PROJECT NAME: Renovations & Addition to Hunziker Hall & Wing

NQP 100 March 11, 2010 Working Draft Rev - 1. The candidate must have sufficient command of the English language, both oral and written.

WIBLE BARBER Architects

NOTICE TO BIDDERS ADDENDUM #2. On May 14, 2018, the Notice to Bidders was electronically mailed on behalf of Tulsa County

SECTION SPECIAL FUNCTION GLAZING

L.20; L.25; L.9; L.12;M.1; K; A]...

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

S for group overnight stays of persons over 2 1/2 years of age, in accordance with N.J.A.C. 5:70-3, the State Fire Prevention Code, Section 408.

SECTION SECURITY PROTECTION PART 1 GENERAL

COMPLETE REVISION November Process Industry Practices Architectural. PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

STANDARD PLAN RELEASE SUMMARY(SPR) Facilities Management Department

REQUEST FOR QUALIFICATIONS STATEMENT (RFQ) CONSTRUCTION MANAGEMENT AT RISK SERVICES FOR THE GREENWOOD HIGH SCHOOL GYMNASIUM GREENWOOD, SOUTH CAROLINA

ADDENDUM G1 JLG Perkett Elementary School RE: Addendum G1 Issued: September 8, 2014

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

Expansion Joint Covers (079513)

ADDENDUM NO. 2 Consisting of 3 pages and Attachments

SECTION INSULATED CONCRETE FORMS - RASTRA 1.01 SUMMARY

Addendum No. 2 May 13, 2017

SECTION PRE-ENGINEERED BUILDING INSULATION

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

SPECIFICATION GUIDELINE

SECTION EXPANSION CONTROL

Reinforced California Architectural Roof Pavers, Pedestal Supported

SECTION EXPANSION CONTROL

SPECIFICATION GUIDELINE

SECTION MANUFACTURED MASONRY VENEER

Point-Supported Glazing

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION ALTERNATING TREAD ALUMINUM STAIRS

A NEW SCHOOL ATHENS BIBLE SCHOOL FOR THE PRESIDENT AND BOARD OF DIRECTORS ATHENS, ALABAMA

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

SECTION TILING

STATE PROJECT NUMBER TZ MnDOT

Stonecraft Industies 8300 County Road Holmesville, OH

Honeycomb. Product Specification Sheet

SECTION MOTOR CONTROL CENTER

AMERICAN SAMOA POWER AUTHORITY Materials Management Office INVITATION FOR BIDS ( IFB ) EAST SIDE WELLS-BOOSTERS SECURITY FENCE REPLACEMENT

SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

The affected construction materials listed under The Fourth Schedule Subsection 33 C (1) in the Act 520, namely: 1.1 Ceramic wash basins MS 2578

SECTION ALUMINUM CURTAIN WALL PART 1 - GENERAL

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

SECTION GROUND FACE CONCRETE MASONRY UNITS

350 Pine Street, Suite 720 Edison Plaza Beaumont, TX Fax

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

THERMAL AND MOISTURE PROTECTION

SAM Supplement Representations, Certifications and Other Statements of Offerors for Government Related Orders

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

SECTION EXPANSION CONTROL

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

FABRICATION OF A NEW INDUCED DRAUGHT FAN DUCTING KILN 2

2003 INTERNATIONAL BUILDING CODE 521

Alabama A&M University Laundry Building at Normal Hill Apartments Project No ADDENDUM NUMBER 4

University of Massachusetts Procurement Department 140 Hicks Way 407 Goodell Building Amherst, MA 01003

, T y f F r a n c i s c o ITSFI MQ

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

Transcription:

ADDENDUM NUMBER FOUR TO THE PLANS AND SPECIFICATIONS FOR MOUNTAIN VIEW GOTEBO SCHOOLS NEW ELEMENTARY & HIGH SCHOOL MOUNTAIN VIEW, OKLAHOMA ARCHITECT S PROJECT NUMBER N14023 October 15, 2015 The following items, applicable to the work designated, shall be understood to be an Addendum, and as such, shall be included in the Contract Documents. General Contractors to inform all subcontractors and suppliers of the Addendum items as appropriate or applicable to their portion of the work. CLARIFICATIONS I. Bid Package 2C Bidders: It has been determined there will be between 4,000 and 6,000 cubic yards of debris dumped at the landfill. Your bid for Bid Package 2C must include covering this debris with a minimum if three (3) feet of soil. Approximately 40% in Phase I and 60% in Phase II. II. Exterior glazing is to be front set, Interior glazing is to be center set. III. Ship ladder to be as specified in Project Manual. IV. Clarification of previous clarification made in Addendum #2: Refer Section 11 6621 Basketball Backstops, Correct paragraph 2.2/A Model Number should be 950 (bent mast) for end goals and 949 (straight mast) for side goals. SPECIFICATIONS Boynton Williams & Associates 900 36 th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com V. Refer Section 04 2204, Masonry Veneer, Paragraph 2.1/C needs to be: Exposed Face Texture: Split Face (Color Two). Disregard reference to burnished block, there is no burnished block in this project. VI. Refer Section 04 2204, Masonry Veneer, Paragraph 2.4/C remove this paragraph. Adjusto-Flex-Mesh AF-H will not be used. Refer to Paragraph 2.5/B for Masonry Veneer Ties at Concrete Masonry Units. Member: American Institute of Architects N14023 Addendum Four Page 1

Boynton Williams & Associates 900 36 th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com VII. Refer Section 07 5400, Thermoplastic Membrane Roofing, Paragraph 3.4/A, Disregard all mention of thermal barrier, there is not one. VIII. Refer Section 08 8800, Glazing, Paragraph 2.2, Add D. Laminated Safety Glass (At Basketball Court Area) 1. General: All laminated composition glass units, whether specifically shown or specified, shall conform to manufacturer s standards as to the maximum size for each type of glass. 2. Product Composition. a) Lite Layer 1: ¼ inch clear fully tempered glass as specified herein. b) Interlayer: 0.06 inch PVB c) Lite Layer 2: ¼ inch clear fully tempered glass as specified herein. 3. Compliance Standards: a) ASTM F 1233 - Standard Test Methods for Security Glazing Materials and Systems, Class 1 b) Consumer Products Safety Commission, Title16- Code of Federal Regulations- Chapter II- Part 1201, Safety Standard for Architectural Glazing Materials, Section 1201.4, Test Procedures: Category II, 400 foot pound impact rating. c) UL 972 Burglary Resistive Glazing Material 4. Edges: Polish edges exposed to view. 5. Compression as required IX. Refer Section 08 8800, Glazing, Paragraph 2.2, Add E. Low-E Insulating Glass 1. Product: Solarban 60 (2) + Clear glass, by PPG Industries, Inc. a) Exterior Pane: 1/4 inch (6mm) Clear glass, b) Air Space: 1/2 inch (13mm) air space c) Interior Pane: 1/4 inch (6mm) Clear glass 2. Performance Value: a) Visible Light Transmission: 70 Percent b) SHGC: 0.39 c) Shading Coefficient: 0.45 d) Outdoor Visible Light Reflectance: 11 Percent 3. Heat Transfer Coefficient: a) U-Value Winter 0.29 b) U-Value Summer 0.27 4. PPG Certified Fabricator only X. Refer Section 11 6123, Folding and Portable Stages, Paragraph 2.2/A Portable Stage Units should have Gray Carpet surface. Member: American Institute of Architects N14023 Addendum Four Page 2

XI. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/B, Seating Capacity: 425 home seats + 6 ADA spaces, & 378 away seats + 4 ADA spaces for a Total of 813 seats. XII. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/C, Updated Dimensions West Side: Closed Depth = 5-7. XIII. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/D, Updated Dimensions West Side: Closed Depth = 4-11. XIV. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/F chair operation to be Semi-Manual. XV. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/F/4. Chair material is intended to be All Polymer XVI. Refer Section 12 6613, Telescoping Bleachers, Paragraph 2.2/J, Updated Dimensions Photography Platforms: provide two nominal 4-0 x 6-0 platforms with railings and steps, one on each side at positions indicated on drawings. ARCHITECTURAL XVII. Reference Sheet 2A1a, Updated Ship Ladder to reflect model 520 as written in specifications. Updated Construction Note #35 to reflect corrected bleacher seat numbers. XVIII. Reference Sheet 5A1a, updated detail C/5A1a to show corrected bleacher closed depth dimensions and media platform relationship to bleachers. XIX. Reference Sheet 5A1b, updated detail A/5A1b to show corrected bleacher closed depth dimensions and media platform relationship to bleachers. ELECTRICAL XX. Reference Attachment D, Revised Sheet 2E2, additional circuitry indicated. XXI. Reference Attachment E for Electrical Clarifications and Substitutions. Boynton Williams & Associates 900 36 th Ave NW l Suite 100 Norman, OK 73072 P 405.329.0423 F 405.364.1439 bwaarchitects.com Attachments, five: A 1 Page B 1 Page C 1 Page D 1 Page E 5 Pages Totaling: 12 Pages END OF ADDENDUM Member: American Institute of Architects N14023 Addendum Four Page 3

ATTACHMENT A

ATTACHMENT B

ATTACHMENT C

ATTACHMENT D

15-14 Mountainview-Gotebo Addendum #4 Electrical Items- Revised sheet 2E2 attached. Clarifications: 1. Specification Section 275116 Sound Reinforcement: Requirements in this section apply only to A/V system indicated for the Gymnasium and associated equipment. 2. Sheet 2E2 - See attached revised sheet 2E2. Additional circuitry indicated. 3. Sheet 2E3 - Revised clerestory lighting circuits to L2A-24 and L2A-25. (No drawing issued) 4. Sheet 2E3 - Light Fixture Schedule Fixture Type C3 shall be the same as type C3E without emergency ballast. 5. Sheet 3E1 - Deleted A/V system subwoofer near southeast corner of gymnasium. (No drawing issued). 6. Sheet 4E1 - Detail A, Electrical Line Diagram Breaker MDP-9 shall be 3P-200A. (No drawing issued). 7. Sheet 4E2 - Panel L2A schedule - Added circuits for lighting changes on revised sheet 2E2 for circuits 28, 30, and 32. (No drawing issued). Light Fixture Prior Approvals: Note: Fixtures submitted for review and not specifically noted as approved shall be considered disapproved. Where fixture series have been approved, final approval shall be obtained in the submittal process. E.C. will be responsible for meeting or exceeding requirements of the fixture utilized as the basis of design. The following fixtures are approved for bid as noted: Fixture Type Manufacturer Part # A LSI GA24-LED-HO-WW-UE-P12.125 24GR-LD4-56-A125-UNV-L835-CD1-U AE LSI GA24-LED-HO-WW-UE-P12.125-EM 24GR-LD4-56-A125-UNV-EL14-L835-CD1-U AD LSI GA24-LED-HO-WW-UE-P12.125-SD50 24GR-LD4-56-A125-UNV-L835-SD1-U ADE LSI GA24-LED-HO-WW-UE-P12.125-SD50-EM Attachment E

24GR-LD4-56-A125-UNV-EL14-L835-SD1-U AK LSI GA24-LED-HO-WW-UE-P12.125 24GR-LD4-56-A125/INV-UNV- L835-CD1-U AKE LSI GA24-LED-HO-WW-UE-P12.125-EM 24GR-LD4-56-A125/INV-UNV-EL14-L835-CD1-U B LSI GA24-LED-SS-WW-UE-P12.125 24GR-LD4-48-A125-L835-CD1-U BE LSI GA24-LED-SS-WW-UE-P12.125-EM 24GR-LD4-48-A125-EL14-L835-CD1-U C1 Vantage A6VOPLED-1-11-35K-L6060-SGC LDN6 Series Halo PD610ED101-PDM6A835-61VCWF C2 Vantage A6VOPLED-1-15-35K-L6060-WHT LDN6 Series Halo PD615ED101-PDM6A835-61VWB C3 PMC 6LE-MX2-013-R-40M-1-L-1-H-SOL-WL LF 5811-1SA-T-20L-8040-M-LD-US-SS C3E PMC 6LE-MX2-013-R-40M-1-L-1-H-SOL-WL with: ISI ABC-100-120 (Inverter) LF 5811-1SA-T-20L-8040-M-LD-US-SS-EM FL1 Elliptipar Style S102 Series io Lighting 05.E.4K.90ASYM.101.1.54.X G1 ILP HB-200WLED-UNIV-4000K-FRL-WC/HB-XX-18Y-PAD (Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets) LUXdynamics LED-GYM-8-2 -UNV-0-10VDIM-850 (Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets) Attachment E

IBL Series G1E ILP HB-200WLED-UNIV-4000K-FRL-WC/HB-XX-18Y-PAD (Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets) LUXdynamics LED-GYM-8-2 -UNV-0-10VDIM-850 (Note: While this fixture is approved for use, the increased wattage of fixtures will require revised circuitry by the E.C. E.C. shall incur all costs associated with revised circuitry while maintaining all control as indicated on plan sheets) IBL Series S1 LSI SDL 4 LED VHO WW UE ZL2N Series 4SNLED LD4 50SL LW UNV L835 CD1 U S1E 4SNLED LD4 50SL LW UNV EL14W L835 CD1 U UC4 Rayon RULA 29 10 30K WH FeelUX Halo TUNELight2 Series HU1036D930P V1 Bartco BSS205 Series Shaper 600 36 W L3/835 UNV NA WP1 WSR LED Series McGraw Edison ISC-F02-LED-E1-BL4-BK WP1E WSR LED Series McGraw Edison ISC-F02-LED-E1-BL4-BK-BBB-XX WP2 Mule EOE-BB-15L3-BLACK-LT Signtex MOE Series Attachment E

WS PMC SS3075-LED-D-W/X-3500K-L-X-WOA-WHT-20V Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (PMC) LumenWerx V3PERD-HLO-LED-80-500-N/A-35-4-NA-UNV-NDM-1- XX-W Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (LUMENWERX) Focal Point Trace FTRL Series WW LSI S-4-LED-VHO-WW-UE-SD50 Focal Point Trace FTRL Series 4SNLED-LD4-64HL-UNV-L835-SD1-U WW2 Forum SAUD-43-65LED35/65LED35-OU/SAT-WBX4-UNV-XX Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (Forum) Focal Point Gammalux Seem 2 LED Series FSM2LW GB35B2-1/SOLED35-UNIV-DVR-4IN-WM-APL/ASLMD- CCM-2CKT WW2E Forum SAUD-43-65LED35/65LED35-OU/SAT-WBX4-UNV-XX Review pending. Provide sample to engineer for table-top testing. Final approval or disapproval will be made in submittal phase. (Forum) Focal Point Gammalux Seem 2 LED Series FSM2LW GB35B2-1/SOLED35-UNIV-DVR-4IN-WM-APL/ASLMD- CCM-2CKT-EMERG X1 Mule ELX-X-B-RC-U-BA Surelites EDG/EDGR Series EUX7R X2 Mule MXBRU-SD-WG2 LXC Series w/ Wire guard Attachment E

Surelites LPX7SD EM Mule MRD-HO-6-54-LED3W-SD Surelites ELM Series LEMSD Attachment E