AN EMPIRICAL APPROACH TO SAPV SIZING IN TROPICAL ISLANDS Sendanayake, S 1., Jayasinghe, M.T.R 2

Similar documents
SELECTION AND SIZING OF BATTERY ASSISTED PV PUMPING SYSTEMS IN RWH

Reference: Photovoltaic Systems, p. 229

SOLAR TRAINING MANUAL (INTERMEDIATE)

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

Stand-Alone Photovoltaic (SAPV) System Assessment using PVSYST Software

Solar Powered Air Conditioning System

8. Modeling using HOMER Part 2

The Impact of Irradiance Time Behaviors on Inverter Sizing and Design

Performance Analysis of PV Solar Power System

Effect of Temperature on Solar Panel Performance

Design and life cycle cost analysis of a SAPV system to electrify a rural area household in India

SIZING CURVE FOR DESIGN OF ISOLATED POWER SYSTEMS

Available online at ScienceDirect. Energy Procedia 110 (2017 ) 89 94

Comparative Study of Photovoltaic Modules and Their Performance in the Tropics: A Case Study in Nigeria

Investigation on A Ground Source Heat Pump System Integrated With Renewable Sources

Micro-power System Modeling using HOMER - Tutorial 1

13-PV System Design. ECEGR 452 Renewable Energy Systems

Journal of Asian Scientific Research

ANN-Based Sizing of Battery Storage in a StandAlone PV System

Impact Study on Power Generation from Photovoltaic System due to Change in Local Irradiance and Temperature at Kathmandu Valley, Nepal

Optimal Sizing of Photovoltaic Based Rural Electrification System under the Influence of Various Seasonal Conditions

Technical and Economic Evaluation of a Solar Photovoltaic (PV) based Distribution Static Synchronous Compensator (DSTATCOM)

Effects of Ambient Temperature on the Performance of a Photovoltaic Solar System in a Tropical Area.

SIZING, POSITIONING AND AIR DUCTING ANALYSIS FOR SOLAR-BASED CAR VENTILATOR

Conservation of Energy by Installing Solar PV System

SECTION-VIII NON-CONVENTIONAL ENERGY

Design of Hybrid Power Generation Using Solarpv Module and Wind Turbine

Question # 1: Write true or false with correcting the wrong statement

How Energy Harvest Controls Can Increase the Benefits of Solar Direct-Drive Refrigerators

OPTOELECTRONIC MODELING OF SOLAR PHOTOVOLTAIC SYSTEM FOR RURAL ELECTRIFICATION USING MATLAB

The mapping of maximum annual energy yield azimuth and tilt angles for photovoltaic installations at all locations in South Africa

Photovoltaic Fundamentals, Technology and Practice Dr. Mohamed Fawzy Aboud Sustainable Energy Technologies center (SET)

Technical Series, Edition 8

Solar Radiation Potential as Energy Source of Photovoltaic Powered Uninterrupted Power Supply in Perlis, Northern Malaysia

APVI Solar Potential Tool Data and Calculations

A study for an optimization of a hybrid renewable energy system as a part of decentralized power supply

Design Guide for Solar Water Pumping. Dankoff Solar Products, Inc.

Solar PV Performance and New Technologies in Northern Latitude Regions

POTENTIAL OF APPLICATION OF PV SYSTEM FOR BWRO DESALINATION IN GAZA

An Investigation of a Grid-Connected Solar Powered Water Pumping System. Mohammed Shadman Salam I.D:

Understanding Solar Energy Teacher Page

LITERATURE REVIEW. 2.1 General. 2.2 Water and Energy: Global crisis and emerging trends. Chapter 2

EVALUATION OF A MICRO PV-WIND HYBRID SYSTEM IN NORDIC CLIMATE CONDITIONS

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Volume 10 - Number 17 - May 2014 (19-25) Effect of Tilt Angle Orientation on Photovoltaic Module Performance. Salih Mohammed Salih, Laith Awda Kadim

Design and Performance Analysis of a Grid Connected Solar Photovoltaic System

Influence of Solar Irradiance Variability on the Design of Photovoltaic/Thermal (PV/T) Systems for Greater Toronto Area (GTA), Canada

The Pathway to Net-zero Energy PLUS Homes

Design and Automation of a Zero Energy Model House (ZEH)*

The Role of Roof Shapes in Design of Green Building Systems (Case Study: Iran, Tehran)

Low-Concentration Output Power Enhancement from Photovoltaic Panels

Journal of American Science 2014;10(8) Software Design of Photovoltaic Grid-Connected Power Plants

EELE408 Photovoltaics Lecture 18 Photovoltaic Arrays & Modules

Utilizing Solar Energy in Order to Reduce Energy Loads of Building

X-RAY Contents lists available at

INTEGRATED ELECTRIFICATION SOLUTION FOR REMOTE ISLANDS BASED ON WIND-PV HYBRID SYSTEM

Investigating the Shading Impact of Rail on the Energy Output of a PV System in Hong Kong

THERMAL AND ELECTRICAL ENERGY YIELD ANALYSIS OF A DIRECTLY WATER COOLED PHOTOVOLTAIC MODULE

How do weather, environment and location affect solar?

Solar Flat Plate Thermal Collector

IJRASET: All Rights are Reserved

Green Star Photovoltaic Modelling Guidelines

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Feasibilty of Wind-Solar Hybrid System for Cleveland, Ohio, USA

Grid-Tied PV System with Energy Optimization

Design and Simulation of Micro-Power System of Renewables

Beneficial effects of water circulation on PV glazing surfaces for improving solar electricity generation

A review of the benefits of a residential solar power installation in western North Carolina

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

CMR Journal of Engineering and Technology Vol.2 Issue.2 April, 2018

Solar Energy Modeling for Residential Applications

Testing of a Predictive Control Strategy for Balancing Renewable Sources in a Microgrid

Design of a Photovoltaic Panel Experiment for an Undergraduate Heat Transfer Lab

The Performance Analysis of a Three-Phase Grid- Tied Photovoltaic System in a Tropical Area

Optimal Photovoltaic System Sizing of a Hybrid Diesel/PV System

RENEWABLE ENERGY SERVICES GRID SOLUTIONS

2. LITERATURE REVIEW

Power Systems Design MARYLAND U N I V E R S I T Y O F. Power Systems Design. ENAE 483/788D - Principles of Space Systems Design

Extreme Engineering for Extreme Conditions

Proper Sizing of Energy Storage for Grid Connected Photovoltaic System

CHAPTER 2 TARIAT SUM, ARKHANGAI AIMAG

Photovoltaic Efficiency of a Grid Connected 10 kwp System Implemented in the Brasov Area

Simulation of a stand-alone power system using renewable energy sources and hydrogen storage

Optimization of solar fraction in a PV/T system applied to a liquid desiccant-assisted evaporative cooling system Eun-Ji Lee 1, Seung-Yeon Ko 1, Jae-W

Loyalty One 163 kw PV Installation. Final Report January Technology. Monitoring. SolarCity Partnership. Best Practices.

International Journal of Applied Science and Technology Vol. 2 No. 3; March 2012

A SIZING TOOL FOR PV STANDALONE SYSTEM

Investigation on Temperature Coefficients of Three Types Photovoltaic Module Technologies under Thailand Operating Condition

Tutorial experiments

CHAPTER-7 CONCLUSIONS AND FUTURE SCOPE

Performance Assessment of 5 MW Grid Connected Photovoltaic Plant in Western Region of India

Running the Electric Meter Backwards: Real-Life Experience with a Residential Solar Power System

Al-Ammar: Application of Using Hybrid Renewable Energy in Saudi Arabia

ANALYSIS OF BERKEN ENERGY THERMOELECTRIC TECHNOLOGY

Website:

SOLAR PHOTOVOLTAICS Part 1

IJARIIE-ISSN(O) Optimising Simulated Model of HRES with HOMER Software for Mirkal M

Comparison of Experimental and Theoretical Output Power of Grid Connected Photovoltaic System in Super Mega Factory

Impact of storage in the operation of Hybrid Solar Systems

AR No. # - Install Photovoltaic Array

Transcription:

AN EMPIRICAL APPROACH TO SAPV SIZING IN TROPICAL ISLANDS Sendanayake, S 1., Jayasinghe, M.T.R 2 3 1 Department of Civil Engineering, Faculty of Engineering, South Asian Institute of Technology and Medicine, Malabe, Sri Lanka. Email:sisuru.s@saitm.edu.lk 2 Department of Civil Engineering, Faculty of Engineering, University of Moratuwa, Katubedda, Sri Lanka ABSTRACT Many Stand- Alone Photo Voltaic (SAPV) situations require a battery storage due to need of stable current supply as well as to ensure no load shedding scenario. In matching a PV generator and a storage battery for a given load, it is important to optimize the capacities of the two to minimize the system cost. If a generic curve can be developed for a particular geographic region, where the annual incident solar radiation levels are known, a matching pair of PV generator and storage battery can be selected for any given load, based on the components cost, which can be used as a tool in designing SAPV systems. As the rainfall patterns and hence the cloudiness in the tropical islands are seasonal and predictable, system performance can be established using short term radiation data. In this research, the tropical island of Sri Lanka is taken as a case study and generic curves for SAPV sizing are developed for two main climatic regions of the country. Key words: Photo Voltaic, Storage battery, Rainfall, Tropical islands 1. INTRODUCTION As more attention is given to PV systems as energy converters in place of fossil fuel, the need to optimize such systems in terms of performance and cost arises. This is more so in case of stand-alone PV systems where optimum system reliability is required at the lowest cost due to higher percentage of cost is incurred on the PV modules. The accurate sizing is an essential step to achieve these aims since it will ensure that demand is met and costs to be cut, thereby lending greater credibility to the practical use of PV systems in the renewable energies market. This is more so, in situations where no grid power is available, and the performance of the load solely depending on the performance of the PV module and the associated storage battery capacity. Many SAPV situations require battery storage due to the need of stable supply of current, as well as to ensure a no load shedding scenario. Essentially, with any PV generator with a backup battery, the right sizing of the generator and storage capacities bear a greater impact on the system cost. In the tropical islands, meteorological parameters such as total cloud cover play a significant role in determining the amount of incident solar radiation at any location and the land mass is broadly demarcated in to geographical regions based on annual rainfall figures. It is observed that due to well established seasonal rainfall patterns brought in by monsoons and convective clouds, the monthly average daily radiation values do not vary significantly within the said region. On the other hand, as the ambient temperatures remain stable with minimal fluctuations in the tropics, the effect of temperature variation on the performance of the battery is minimal. Hence, if a load independent graphical relationship can be developed between the capacities of the PV generator and the storage battery, for no load shedding scenarios, such can be used as a generic curve for a particular region defined by the rainfall pattern. Taking into account the percentage of power requirement out of the generated power output from the PV module for the load and the variations in incident solar irradiation levels over a period of time, the need of a storage battery is discussed. Power output characteristics of a lead acid accumulator is non linear and varies with the load

4 characteristics. Besides the battery life is determined by the load as well as the duty cycle and the system has to be properly designed so as to match the PV generator and the accumulator with the load. This will ensure a non load shedding scenario indicating reliability in operation. Hence a generalized sizing curve is developed and validated to facilitate the selection of a matching pair of generator and battery capacities for a non load shedding situation. Such a curve can be used as a useful design tool. 2. OBJECTIVE To develop load independent iso-reliability curves for a given geographic location to select matching pairs of PV arrays and storage battery capacities to minimize system costs for non-load shedding scenario. 3. MATERIALS AND MATHODS A Numerical-Analytical approach to SAPV sizing is used based on the concept in which supply reliability is defined in terms of the length of time that the system supplies load without interruptions (1). Considering the system load or demand to be constant in time, the study attempts to characterize the daily energy balances. When dimensionless variables are used to analyze these balances, more universal results are obtained (2). Hence, the photovoltaic generator capacity, C A, is defined as the ratio between the average daily energy consumed by the load. The accumulator capacity, C S, is defined as the useful storage capacity of the accumulator, C U, divided by the energy consumption of the load. Thus, C A = η G A G G m= β [1] L C S = C U [2] L Where A G and η G are the area and conversion efficiency of the PV generator, G m- β is the monthly mean value of daily irradiation on the south facing generator surface at a tilt angle of β. L is the mean value of the daily energy consumption of the load and C U is expressed as; C U = C B. PD max [3] Where C B is the nominal capacity of the accumulator and PD max is the maximum depth of discharge. Considering the basic engineering design concept of Q t < C t for any t, Where Q t is the demand in time t, and C t is the capacity in time t, for the functional reliability of the system. Applying same for a SAPV battery charging system; Q max < C min, for any given t, assuming that both the system capacity and the demand vary with time. Using measured and synthetically generated radiation data at site, a sizing curve is derived using the dimensionless parameters C A and C S, calculated using daily energy balance. C S is calculated as a function of the generator over the period of time and thus determining the maximum storage required for the system to operate without shedding load for the minimum generator size. To collect data, prototype models are set-up in two locations in Colombo, in the wet climatic region of Sri Lanka and in Anuradhapura, in the dry climatic region of Sri Lanka respectively. The model consists of a 12V, 75W p stand-alone PV module of exposure area of 0.25 m 2 (i.e. 0.5 mx0.5m) with manufacturer specified conversion efficiency (η) of 10% is connected to a 100Ah, 12V deep cycle lead-acid battery via a 10 Amp charge regulator. The battery is allowed to charge when solar radiation is available during the day and after allowing for a settling period of 1 hour for the battery to establish its chemical balance, a load of 115 Wh is connected to let the battery discharge.

5 Before the load is connected, the open circuit voltage (OCV) of the battery at rest is measured and recorded using a digital voltmeter and after the regulated discharge, OCV is measured and recorded again at rest. The load is calculated to match the average annual generator capacity for the location (η*a*g h ) so that C A = ηag h /L is approximately 1.00. G h, the average daily global radiation values for one year are taken from the Department of Meteorology, Sri Lanka, whose weather stations are located in close proximity to the test sites. As such, those radiation values can be taken as that incident at site. In this case the load equivalent to 115 Wh is taken as 4 numbers 20 W CFL bulbs running for 1.3 hours. The PV module is placed horizontally to minimize the tilt effect hence to avoid monthly variations on incident global radiations. The measurements were taken for one full year to encompass all seasonal variations. Using the recorded values of Open Circuit Voltage (OCV), the SOC% of the battery as a percentage is derived from the generalized curves (Perez) for deep cycle lead-acid batteries (3). The SOC% is taken to the nearest round figure from which the maximum battery usage, in days, is calculated (C S = C U /L). From all C S values calculated for the year, the maximum value for a given C A (in this case C A = 1.00) is selected and plotted against C A. The exercise is carried out simultaneously for C A = 1.25, 1.5 and 2.00 with increased number of modules connected in series and the corresponding maximum C S values are plotted against C A values. For C A = 2.00, 2 numbers of 75W p modules are used with a combined exposure area (A) of 1.00 m 2 and for C A = 1.25 and 1.5 the module surface is partially covered accordingly. Chart 1. 4. RESULTS AND DISCUSSION The load independent sizing curve derived from the models for battery assisted SAPV systems for the wet and dry climatic regions of Sri Lanka is shown in Chart 1. The resultant chart C A versus C S shows the minimum relationship required between the generator capacity and the battery capacity in order to maintain no load shedding and to ensure 100% system reliability. The chart is generalized to a particular geographical region and is independent of the load. Therefore, for any given load at a particular site, the generator capacity and size can be determined. Similarly, C S multiplied by the load divided by the nominal battery voltage gives the battery capacity required in Ah. In the chart, C S is selected to represent the deepest climatic cycle during the examined period thus giving a much reliable correlation between the parameters. This cycle is the effect of the daily correlation of the solar radiation, on the battery state of charge (SOC), for a system with a given generator and load. It is also noted that longer the radiation data time series, more the increase of prediction reliability. It is noted that when the coordinates corresponding to a particular period where the parameter C S is high (corresponding to poor performance condition of the SAPV system) the sizing curve shifts upwards. This indicates that, though the presence of a bad year has a pronounce effect on the shape of the curve, when a combination of small generator and large battery has been used, the effect is reduced for

6 combinations of large generator and small battery. Therefore, it is shown how combinations of a large generator and a small battery seem to be more likely to withstand unpredicted events of low solar radiation sequence. Given the high sensitivity of the storage requirement on the length of the solar radiation data series used on system sizing, the above could be a practical way to deal with the unpredictability of solar radiation. The chart provides the designer the option of choosing a desired combination of array size to battery storage capacity, which can be determined taking in to consideration the cost factors of individual components. However, when selecting the PV array and the battery size consideration should be given to match the charging and discharging currents as much as possible in order to prolong the battery life. Higher charging and discharging rates increases the internal resistance of the battery due to heavy electrolysis of chemicals shortening the battery life. It should be noted that the charts, battery voltage (in VDC) against SOC% are of different profiles for different types of batteries and the ones used in this research are the generalized form for deep cycle lead-acid batteries. Further, if non deep cycle batteries are used, the useful energy a battery can provide is restricted to its maximum Depth of Discharge (DOD), again depending on the battery type and make. The lead-acid reaction is temperature sensitive. Cooling the cell changes its voltage against SOC% profile. As the lead-acid battery cools, its internal resistance increases. This means that voltage elevation under recharging is increased in cold cells. The same internal resistance increase produces increased voltage depression in cold cells when discharged. However, in tropical weather conditions, the effect of temperature on the chart profile is negligible though increased ambient temperature will shorten the cycle life of battery. As Sri Lanka can be demarcated in to two distinct geographical regions based on the incident solar radiation levels (Chapter 4), another set of values for C A versus C S chart are obtained by taking measurements at Anuradhapura in the dry region. These two charts can be used widely for SAPV systems with battery storage designed for any load condition. It should be noted that for both data collecting set ups, C A is taken as 1.04 instead of 1.00, i.e. for Colombo when the average generator size is 119 Wh/day, the load is taken as 115 Wh/day and for Anuradhapura in the dry region when the average generator capacity is 130 Wh/day, the load is taken as 125 Wh/day. This was to compensate for system losses as otherwise the load could be greater than the average generator capacity imposing a load shedding scenario at any given time. Analyzing the two C A versus C S charts, for the wet and dry regions it is clear that at higher values for C A the charts coinciding, demonstrating the existence of the two regions in a small geographical area receiving almost similar amounts of solar radiation throughout the year. The tropical climate of the country ensures an average of 4.5 KWh/day of global radiation levels for both regions with the radiation levels dropping to around 2-3 KWh/day in rainy or overcast days. However, at C A = 1.00, the difference in the rainfall, hence the cloudiness experienced by the two regions is clearly visible with the dry region showing C S value of 9 days as against 10 days for the wet region. Therefore, at C A = 1.00 the systems in the dry region can adopt a slightly smaller battery for no load shedding situations. Hence for practical situations, the upper curve i.e. the curve for the wet region can be universally used in Sri Lanka for SAPV designing for any given load. 5. CONCLUSION A set of load independent values can be obtained matching the capacities of PV generator and the corresponding battery storage for a given constant load in a specific geographical location where the incident solar irradiation is known. Graphically presented, such curves can be utilized

7 by system designers as iso-reliability curves for SAPV systems indicating the optimum capacities of the PV generator and battery storage pair for system reliability. 6. REFERENCES [1] Dennler, G., Bereznev, S., Fichou, D., Holl, K., Ilic, D., Koeppe, R., Krebs, M., Labouret, A.; Lungenschmied, C., Marchenko, A., Meissner, D., Mellikov, E., Meot, J., Meyer, A., (2007), A self-rechargeable and flexible polymer solar battery, Solar Energy, Volume 81, Issue 8, Pages 947-957 [2] Klein S.A. (1994), Calculation of monthly average insolation on tilted surfaces, Sol Energy, 43(3): 153-68. [3] Perez, R., Seals, R.(1987), A new simplified version of Perez diffuse irradiance model for tilted surface, Sol. Energy. 3: 221-231.