Implantable,Programmable and Refillable

Similar documents
DATA LOGGER Model DL-SA11

LifeTrack technology: detecting all breaks in the cold chain. Introduction:

OPSIS LiquidLINE KjelROC Analyzer

Single Use Temperature USB Data Logger

OPSIS LiquidLINE KjelROC Analyzer

OPSIS LiquidLINE KjelROC Analyzer

C300 Cond/TDS/Sal/T Meter. Manual

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter

Journal of Pharmacological and Toxicological Methods

Cole-Parmer Pro-Spense Disposable Syringe Pump User s Manual. Model # (100ml), # (260ml) Publication REV-A

MultiLab BROCHURE MULTIPARAMETER LABORATORY INSTRUMENTS W61-02

SIWAREX FTC The belt scales in SIMATIC More than just standard. siwarex ftc

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

Coating Thickness Meter Data Sheet / Instructions

Coating Thickness Meter Coating Thickness

Eureka Sub3 Water-Quality Multiprobe

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

AS950 REFRIGERATED SAMPLER

AS950 ALL-WEATHER REFRIGERATED SAMPLER

BODYGUARD COLOURVISION 575 PCA INFUSION PUMP

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

COLow COHigh COLow/H 2

COLow COHigh COLow/H 2

User s Guide for USB Connection Patrol System

Advanced FEA Stress Analysis of Medical Instruments and Devices using Femap, NX Nastran and LS-DYNA

Data Logging Solutions from Lascar Electronics

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

EL-USB-2-LCD Temperature, Humidity and Dew Point Data Logger with LCD Screen

Automatic hardness testing devices

Tinytag Transit 2. Manual

i-leaktek 6600 Leak and Seal Strength Tester

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside.

MS-70/ MX-50 MF-50/ ML-50

Digital TORQUE Indicator

Gyrolab xp workstation

RPBS-1 PORTABLE SCALE

Halogen Moisture Analyzers

SmartTouch. Truly smart flue gas measurement. The new testo 300 flue gas analyser with smart-touch technology.

Automated Soluble Salt Meter

Automatic Isokinetic Sampler ST5

New Measurement Engineering for Heating Technicians and Inspectors

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

SOLUBLE SALT METER SETTING THE NEW STANDARD IN SALT MEASUREMENT. Phone Phone: +31 (0) Fax: +31 (0)

Moisture Analyzers ISO 9000 CERTIFIED

OPSIS LiquidLINE KjelROC Analyzer

Optimizing Performance Bench Scale Service Checklist

Continuous Infusion Toxicity Studies in Rats; General Considerations

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

testo 330 Flue gas analysis with increased convenience and safety

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

Indoor Air Quality Tools

Tissue Microarray Catalog

Helping Make Safe & Reliable Products Because people count on your products everyday

PTC PATIENT THERAPY CONTROLLER (REF 12860) For use with Prometra Programmable Infusion Systems PTC Software Version

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

Moisture Analyzers. New methods of moisture content analysis

L A B D I S S O L V E D O X Y G E N I N S T R U M E N T S

Calibration and Standards. AMCO Standards for use in Drinking Water Analysis

PTC PATIENT THERAPY CONTROLLER (REF 12860) For use with Prometra Programmable Infusion Systems PTC Software Version

Installation & Calibration Manual

Q u a l i t y C o n t r o l U s i n g Tu r b i d i t y Measurements

New Measurement Engineering for Heating Fitters and Technicians

Professional flue gas analyzer Testo AG LPG

New Approaches and Technologies in Personal Sampling Pumps

To Measure & Optimise H 2 in Molten Aluminium. Rugged, accurate and economical.

Winzer Corporation 1 Revision: 4.0

Dynex DS2 2-Plate ELISA Processing System. Compact Easy to Use Innovative A Perfect Combination.

VERTICAL AUTOCLAVE DELUXE. MODEL NO.- Acm A

Menu and Throughput to Accommodate Your High-volume Testing Needs

Quick Select Guide. 6-Series. products

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Professional flue gas analyzer

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

Category Index. Disposable Temperature USB Data Logger

User s Guide. Localization system StarGazer TM for Intelligent Robots.

EkoSonic Endovascular System

Whitley Automated Spiral Platers

Moisture Analyzers ISO 9000 CERTIFIED.

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

Quantum Perfusion Systems

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

A fast, lightweight, handheld X-ray tube based XRF alloy analyser

Professional flue gas analyzer

GAS CHROMATOGRAPH FOR MULTIPLE IMPURITIES

Portable Multi-Parameter Water Quality Meter LMPWM-A1 Series

YOUR EYES IN THE FIELD

ECO INSTRUMENT (NS M)

Maximize reproducibility of your biological sample prep

Instruction Manual Dräger MSI EM200-s

GESIPA -AUTOMATIC RIVETING MACHINES

P300 ph/mv/t Meter. Manual

FLEXCART LIQUID METERING SYSTEMS The family of flexible, next-generation metering systems for PolyOne advanced liquid technologies

Model BF 720 Incubators Avantgarde.Line with forced convection

madur portable gas analyser

Unit 1, 176 Forest Rd, Hurstville NSW USB Logger User Guide

Tank Scale Service Checklist

GENECHECKER Ultra-Fast PCR System

Sievers M9 TOC Analyzers

Transcription:

M i c r o I n f u s i o n P u m p Implantable,Programmable and Refillable

The World s First Totally Implantable, Programmable Micro Infusion Pump for Small Laboratory Animals Accurate patented Rotary Finger Method Every pump is factory tested and calibrated Better than 5% accuracy 1L/hour to 30.0L/hour in 0.1L/hour steps 291 discrete infusion flow-rates Programmable infusion protocols (simple and complex) Battery life of up to 6 months (continuous 1.0L/hour) Totally implanted in subcutaneous space Refillable (reservoir) percutaneously via refill port with re-sealable septum With iprecio catheters, test your drug's effects nearly anywhere Easy to use menu driven software for infusion protocol programming

iprecio is an Ultimate Choice This implantable infusion pump uses a patented, microprocessor controlled peristalsis mechanism for accurate controlled flow. It is the only implantable and programmable pump for small laboratory animals. iprecio can infuse fluids continuously for as long as six months and it can be refilled via a percutaneously accessible port. iprecio 3 Key Features and Benefits Implantable Programmable Refillable Tetherless free moving animal model No exit wounds (reduced infection risk) No wires or connections to animal to allow stress free infusion Recovery Period Dose Escalation/De-escalation Studies Wash-out periods Complex Infusions (daily/weekly repeat dosage, circadian rhythm,... ) Complex pharmacokinetic and tolerance studies based infusion protocols including constant continuous dose, circadian rhythm infusion to complex oral dosage simulations three times per day. Further, iprecio enables to test the relevance of dosing time or dosing protocol on the therapeutic index of small and large molecules. Multiple drugs Multiple solvents/vehicles Multiple concentrations of drug(s) Increase study effectiveness by testing multiple drugs/vehicles within one animal. This enhanced flexibility is made possible by using wash-out periods between drug administration when only saline is infused to keep the catheter patent. Combination of Refillable and Programmable makes iprecio an extremely flexible and versatile infusion pump.

Innovative Drug Infusion Technology for Laboratory Animals Implantable Programmable The pump can be completely implanted in small laboratory animals subcutaneously. Thus, the animal moves freely without any restraini.e. tetheringduring drug infusion. Additionally, infection risk is reduced, and the animal is likely to be significantly less stressed than in a tethered infusion model. Using the easy to use menu driven iprecio software, header information along with infusion protocol details are entered and ultimately downloaded to the pump's flash memory. Start Time, End Time, Flow-rate (1.0L/hour to 30.0L/hour), Constant and Variable infusion mode are programmable. Both Constant and Variable infusion options have Instant or Recovery Mode Infusion settings. In Variable infusion mode, 10 flow-rate steps are user programmable. Further sophistication may be obtained by using iprecio's Repeat Management Software <4 steps> Easy to use menu driven software for infusion protocol programming Header Input General Information of the study Mode where the 10 steps are programmed within one or several repeat cycle loops (5 loops maximum). Each loop may be repeated 2-250 times. The programmable feature will make iprecio pumps indispensable for applications where accurate flow infusion, recovery/washout periods, constant/variable dose or complex circadian infusion studies are necessary. Mode 1.Constant : Configure one constant flow rate for infusion subject to battery life 2.Variable : Configure up to 10 discrete infusion steps between 1L/hr to 30L/hr Data Communication (IR) IR communications are used for loading the infusion program and activating the pump. It is made directly without removal from the blister pack. Therefore sterility is maintained until the pump is taken to the sterile surgical suite for filling/activation and implantation. Unique S/N ID with factory calibration data Each pump's unique ID and calibration factor is read from each pump during the programming phase. Groups Animal Groups Settings sconstant Mode svariable Mode Refillable You can replenish any medical fluid in the pump via percutaneous access to the pump refill septum and reservoir after implantation of the pump. Therefore, long-term drug infusion can continue until the installed battery life has run out. The reservoir is elastic and configured in such a geometry as to allow gentle palpation to confirm an approximate level of fluid in the reservoir. Precision The technology driving the infusion is a patented Rotary Finger method. This method is a unique form of peristalsis. The precise microstick pushes a rubber tube in the pump in a uniform and sequential manner. The accuracy of iprecio is +/-5%. Animals Pumps Infusion Mode 1. Instant Infusion : Start infusion of the drug instantly by pre-programmed protocol following activation of the pump drive. Protocol Download Advanced Settings of the Infusion / Modes Download of the Protocol Settings to the each Pump Drug Filling Pump Activation Implantation Start Infusion Activate the pump between 3 minutes and 3 hours before the infusion start time. Refilling 2. Post RecoveryDelayedInfusion : Start Infusion of the drug after reservoir contents are exchanged percutaneously following recovery period from implantation surgery by pre-programmed protocol. The pump infuses saline or buffer during the recovery period. Protocol Download Saline Filling 3hours* Pump Activation Implantation Saline Saline Recovery Period Withdrawing the Saline *Activate the pump between 3 minutes and 3 hours before the recovery start time. Exchange 30min. Drug Filling Start Infusion Automatically drained the dead volume before the start of infusion. Refilling Repeat Mode Weeks 7L/hr Repeat Mode program image 5L/hr 10L/hr Weeks 12L/hr Repeat Mode allows the 10 flow steps to be used in a more sophisticated infusion protocol where up to 2500 steps may be programmed. Therefore infusing protocols taking into account circadian rhythm, oral drug intake (3-4 times per day) or studies for dose response curves may be programmed. 10 steps x 250 times repeated (subject to battery life) Repeat Mode setting window 3 groups shown. Set number of times to repeat each group. GLP Compliance For GLP compliance, accuracy of flow infusion can be validated. In addition, the iprecio can be user calibrated. User log-in and password control options are available to the study director to restrict access to iprecio Management Software. Long battery Life Research Applications Status Manager WindowOff-line monitoring You can confirm the administration schedule and the remaining volume of the pump reservoir, refill date, record the factual refill date, upload the log data of the pump. The battery life is up to 6 months at a continuous flow rate of 1.0L/hr. You can confirm the estimated battery life on the PC Screen when you set the infusion protocol with the iprecio Management Software. L/hr 1.0 8.5 19.0 30.0 Continuous Infusion hours 4,328 669 307 196 approx 6 Months 1 Month 1.8 weeks 8.1 days Total Volume ml 4.33 5.69 5.83 5.88 iprecio is an innovative infusion pump which is used for small lab animal infusions in many different research and application fields.

Specifications Micro Infusion Pump iprecio Infusion Method Reservoir Tubing Activation Method Data Communication Range of Accuracy Battery Life Size/Weight Type of Usage Package Rotary Finger Method (patented peristalsis) 900L Built-in Elastic Reservoir (Medical Grade SIBS) Material : Medical Grade SEBS (Olefin Series) Inner Diameter : 0.57mm / 0.022in Material : Medical Grade SEBS (Olefin Series) Inner Diameter : 0.57mm / 0.022in Outer Diameter : 1.22mm / 0.048in / 3.66Fr Length of Outer Tube : approx.135mm IR Communication 1.0L/hr - 30.0L/hr (0.1L/hr resolution) < 5% (under 0-80cmH2O pressure) 6 Months at 1.0L/hr - 1 Week at 30.0L/hr 38.7 (L) x 19.2 (W) x 9.7 (H) mm / 7.9g Disposable EO Sterilized blister package (5pcs / box) iprecio Management System iprecio Management Software( requires Windows PC and USB port ) smanagement of Infusion Protocol Study Name, Number/ID, Date, Experiment Period, Section Name, Operator, Number of Groups/Animals, Animal Species, Strain, Age, Compound Name/ID, Concentration, Buffer Name, Route, etc. sautomated Recognition of Pump ID/Calibration Factor spump Programming via-pc Programmable Parameters Infusion Mode Selection Mode Selection Dead Volume Setting Flushing setting soff-line Management of Infusion sre-calibration of iprecio pump supload of Pump's log Interface Communication with Pump Power Supply Size / Weight Accessories Inner Tubing Outer Tubing iprecio Data Communication Device Start date/time, Stop date/time, and Flow-rate. 1. Instant Infusion Mode 2. Post Recovery (Delayed) Infusion Mode 1. Constant Mode 2. Variable Mode (maximum : 10 Flow rate steps) In Variable Mode, Repeat Mode is selectable. Catheter diameter / length or Actual volume Flushing Rate and Exchange Schedule Schedule Management (Exchange schedule, Refill date/time, Alarm, Elapsed time & volume infused, etc.) USB / Serial Interface IR Communication PC USB or AAA batteries 120 (L) x 67 (W) x 35 (H) mm / 147g (with batteries) 1 USB cable (1m), 2 AAA batteries The iprecio is for use in Laboratory Animal Research ONLY. Not for human use. EO Sterilized blister package 5pcs / box The iprecio Management System consists of: Data Communication Device USB cable, 2 AAA batteries iprecio Management Software Installation CD iprecio User Manual Actual Size ( 38.7 x 19.2 x 9.7mm / 7.9g ) www.iprecio.com E-mail : iprecio@primetech.co.jp 1-3-25, Koishikawa, Bunkyo-ku, Tokyo, 112-0002 JAPAN Phone: +81-3-3816-0851 Fax: +81-3-3814-5080 1002-2000W