AN INNOVATIVE DESIGN FOR PAVING USING VERTICALLY- INTERLOCKING ARTICULATED CONCRETE MATS

Similar documents
PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

Installation Manual. ArchCast Bridge. 3-Sided Precast Concrete Bridge Structure

EDGE RESTRAINT SYSTEM

NOTICE XX/2017 SUPPLY AND ERECT PRE-CAST CONCRETE PALISADE FENCING WITHIN THE KOUGA MUNICIPAL AREA

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For POWER-STRUT Mounting System only

For Silverback Solar

SECTION CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795)

A. Division 01 Specification Sections, Drawings, General Conditions, Supplementary General Conditions, and Special Conditions apply to this section.

TURFSTONE PAVERS SECTION CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795)

2.1.2 Minimum wall thickness shall be 90 mm Frames and covers shall be bitumen coated by dipping.

RPC Contracts is committed to innovative product development and manufacture. T o help you obtain maximum enjoyment and long service from any RPC

Miller Collective Safety at Height Solutions EPIC ULTRA Barrier System EPIC Post-N-Barrier System EPIC Basic Barrier System

ArmorFlex. Articulating Concrete Block Revetment System

WATER QUALITY. Our Focus Today. Erosion Control Technologies & Solutions. What is Soil Erosion. Federal Regulations

SECTION PAVING SLABS ON AN AGGREGATE BASE

Silva Cell. Silva Cell Two-Deep Installation Instructions. Helping Trees Live in the Urban Environment

High-strength Slope Retention Systems

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION CHAIN LINK FENCING

SECTION COLD-FORMED METAL FRAMING

Earth Retaining System

Save time. Save money. Specify a fast, economical Vist-A-Wall MSE. fast and easy to install. They adapt well to curves, angles and

GreenLock L9 Heavy Duty Retaining Wall Block (RWB) Features and advantages of the L9 retaining wall block

Asphalt on Concrete Base with Waterproofing Membrane

Installation Guidelines

ADVANTAGES THE LIGHTEST FILLING SOLUTION HIGH LOAD-BEARING CAPACITY

SPECIAL SPECIFICATION 6658 Time Warner Communications System

SPECIAL SPECIFICATION 6664 Level (3) Communications System

STANDARD DESIGN NOTES 1 / 2

SECTION UTILITY POLYETHYLENE CONTAINMENT PIPE SYSTEMS

METALWORKS RH215 Faceted Custom Hook-on Panels

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

Contract18. Vitrified paving FLAT ROOF BALCONY ROOF TERRACE DISPLAY AREA

Section 2 Supplemental Specification 2.11 High Tension Cable Barrier

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL

SILVA CELL TWO-DEEP INSTALLATION INSTRUCTIONS HELPING TREES LIVE IN THE URBAN ENVIRONMENT

RPC Contracts is committed to innovative product development and manufacture. T o help you obtain maximum enjoyment and long service from any RPC

CONSTRUCTION SPECIFICATION FOR CONCRETE UNIT PAVERS

PHB TechBullet #8. Edge Restraints

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

TABLE OF CONTENTS. Chapter 3 - WATER MAIN, VALVES, HYDRANTS AND APPURTENANCES. Chapter 4 - SANITARY SEWER. Chapter 5 - STORM SEWER

SECTION PAVING SLABS ON AN AGGREGATE BASE

SECTION PAVING SLABS ON AN AGGREGATE BASE

Product Guide. Fabric-formed Concrete Erosion Control and Armoring Systems. Filter Point. Filter Band. Uniform Section. Enviromat. Articulating Block

Steel Forming System BROCHURE. A durable, all-steel forming system that is ideal for pier caps and self-spanning applications.

PAVING SLABS ON A CONCRETE BASE

Requirements for Measuring and Pricing of Structural Concrete

INS T A LLA T I O N G U I D E

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL

CW 3620 INSTALLATION OF UNDERGROUND TRAFFIC SIGNAL SERVICES TABLE OF CONTENTS

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...

SPECIFICATION FOR REINFORCED SOIL WALL

SUMO Wall Shoe. For bolted wall connections. Technical Manual. Version: Canada and United States 08/2016

Figure Inlet protection (Source: Minnesota DOT)

San Antonio Water System Standard Specifications for Construction ITEM NO. 812 WATER MAIN INSTALLATION

Channel FlexTM P-BD Series

BY DAYTON SUPERIOR. Max-A-Form FORMING SYSTEM

ENGINEERED SOLUTIONS. Contech Bridge Plank

PARKING LOT SUBGRADE AND PAVING 1. BASE LAYER SHALL BE MINIMUM 150MM THICK OF COMPACTED 19MM MINUS CRUSHED STONE

SECTION 26 - COLD PLANE ASPHALT CONCRETE PAVEMENT TABLE OF CONTENTS

CONSTRUCTION SPECIFICATION FOR CONCRETE ROAD BASE

SECTION SITE PREPARATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

I

Construction Specification for Utility Adjustments

A.2.a Random Riprap... Table

P: F: Resi-Ply FORMING SYSTEM BY DAYTON SUPERIOR

NOVEMBER 2016 MAGNUMSTONE. retaining walls installation manual

DURRELL DESIGN GROUP, PLLC ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON, MISSISSIPPI.

A. Pre-engineered, pre-finished extruded aluminum Pavilions.

Construction Procedures

OVERSHOT GATE TECHNICAL DATA SHEET

SECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS

Valmont Newmark is your single source for steel, concrete or hybrid structures for power delivery

Specification for Road Works Series Road Restraints Systems (Vehicle and Pedestrian)

BEBO CONCRETE ARCHES TECHNICAL GUIDE

ARMTEC.COM. Bridge Materials / Versatile Low Maintenance Rapid Installation

For HatiCon Solar Mounting System only

SECTION ORNAMENTAL ALUMINUM RAILING

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Main Roads Standard Specification

SECTION CONCRETE GRID PAVEMENTS (1995 MasterFormat Section 02795)

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING

ITEM 461 STRUCTURAL PLATE STRUCTURES. Galvanized steel plates shall conform to AASHTO M167 and aluminum plates shall conform to AASHTO M219.

The Leader in Underwater Piling Repair Technology

Chapter 8 Anchoring Structures

Hardscaping Installation Manual

CONSTRUCTION SPECIFICATION FOR GUIDE RAIL ENERGY ABSORBING TERMINALS

BEST PRACTICE DESIGN FOR CONCRETE PAVERS FOR CANADIAN MUNICIPAL APPLICATIONS

CHAPTER 11: WALLS.

SECTION CONCRETE GRID PAVEMENTS (Turfstone) (1995 MasterFormat Section 02795)

SECTION INTERLOCKING CONCRETE PAVERS

SECTION COLD-FORMED METAL FRAMING

SEPA Environmental Checklist Mercer Island Center for the Arts. Attachment F Geotechnical Supplemental Memo

Expansion Control Solutions

TECHNICAL MANUAL. SUMO Wall Shoe. For Bolted Wall Connections

Expansion Control Solutions

CW 3235 RENEWAL OF EXISTING MISCELLANEOUS CONCRETE SLABS TABLE OF CONTENTS

CONCRETE TILE PAVERS

Transcription:

AN INNOVATIVE DESIGN FOR PAVING USING VERTICALLY- INTERLOCKING ARTICULATED CONCRETE MATS SUMMARY Charles A. Weiss, Jr., Joe G. Tom, and Philip G. Malone Geotechnical and Structures Laboratory U.S. Army Engineer Research and Development Center 3909 Halls Ferry Road Vicksburg, MS 39180-6199 Phone: 601-634-3111 Fax: 601-634-3242 E-mail: Charles.A.Weiss@erdc.usace.army.mil Paving mat systems using cast concrete block held together with embedded wire rope or cable have found wide use in erosion control, and paving fords, boat ramps and low-volume roads. Cable-linked paver blocks have the advantage of being less subject to displacement than separated pavers. They are less subject to washout, are difficult to vandalize and are not lifted by tracked vehicles. Their disadvantage has always been that the sections of the mats have to be connected to be effective. This requires that U-bolts or wire splices be installed between mat sections. The bolts and splices have to be unbolted or cut to move the mat sections. A new design of vertically-interlocking paving mats has been developed to overcome the problems of placing and removing connections between mat sections. This makes a paving system that is easily placed and easily lifted and moved. Also, since this new paving system consists of two distinct layers of blocks, each upper block rests on parts of four blocks below it; so the load on the upper block is effectively distributed over four lower blocks. The lower ground pressure makes the paving system useful where the sub grade soils are not ideal. The upper layer of block is staggered so the openings from the top of the upper block to the ground are smaller and the problem of vegetation growing up between the blocks is reduced. The complete system consists of two layers of paver mats. Each layer of mat consists of concrete pavers cast on a grid of intersecting cables that hold the pavers together. The shape used for the block is the key to interlocking the mats vertically. In the casting process, one vertical half of the block is formed as a square paver (the square side); but the lower vertical half of the block is formed as a square rotated 90-degrees (the diamond side) and dimensioned so that the corners of the square are at the mid-point of the sides of the upper square side. When the mat is laid down with the square side on the ground surface, the diamond side has spaces between the diamonds that are sized to allow another mat layer to be placed diamond side-down with the diamonds from the upper mat fitting between the diamonds on the lower mat. The exposed top of the twolayer mat consists of the square-faced side of the pavers. One three-paver by three-paver mat section can be laid down over the intersection of four similar mats below it to lock them together. Under normal circumstances the weight of the upper mat will guarantee that the lower mats remain locked together until the upper mat is lifted off. 637

The design of the articulated paving mat system is based on selecting two tessellating shapes for the sides of the blocks. It is possible to develop paving using this system that is both functional and aesthetically pleasing. 1. INTRODUCTION Army engineers have very successfully employed steel cable and concrete articulated mats to stabilize river banks and the prevent scour at the bottom of navigation channels. These articulated concrete mats are assembled from precast concrete panels that are approximately 7.6 m 1.2 m 10.2 cm thick. The panels are typically assembled into articulated concrete mats: 35 panels 43 m wide (Mississippi Dept. of Transportation, 2002). The mats are assembled using a wire-wrapping system. Figure 1. Articulated concrete mats (left) are assembled by using wire ties (right) to attach the panels to each other and to adjacent rows panels. Applications of smaller articulated concrete mat have been used in creating fords or landing area on streams and in reinforcing gravel roads in Army training areas. Applications in training areas have typically involved the use of single blocks cast with segments of cable imbedded in the block or arrays of blocks cast with continuous sections of steel cable between blocks. In either the single block or the arrays of blocks the system used to attaching the blocks or arrays to one another is a persistent problem. Figure 2. Cable articulated mat made by attaching the blocks at four points to form a block paving for a landing ramp. 638

While the more permanent scour-control mats are attached by wire splices the smaller single blocks and arrays are attached block to block or section to section using U-bolts, clamps, washers and nuts. U- bolt spices require a significant amount of labor and a degree of dexterity is involved that allows for little or no automation. When the mats must be placed below water they have to be assembled on land and lifted and placed into the water. If the splices have to be installed on submerged blocks, the work becomes very laborious and slow. The problems of fasteners become more complicated when the blocks are used for temporary paving in a training area. Corrosion on the fasteners can be enough of a problem that cutting the cable attachments may be the only practical option. The goal of this project is to develop an articulated concrete mat that can be laid in two layers in such as way that the overlap between layers can be used to lock the lower layer and upper layer together. The block could be placed such that it acts in a fashion similar to Velcro so that protrusions on one mat would plug into similarly shaped holes in the lower mat, and the weight of the upper mat would prevent the lower mat from shifting. Simply placing the upper mat over an adjacent bottom mat attaches all of the mats together. The process of laying mat can move more quickly and even placing mats underwater becomes more practical Without having to have wire splices or U-bolt attachments. When it is necessary to lift the articulated mats, simply lifting off the upper layer releases the lower layer and all of the pieces of the mat can be moved without having to remove any fasterners 2. SHAPES OF THE INTERLOCKING BLOCKS A vertically-interlocking array can be made by casting copies of a block that has one tessellating shape (for example squares) on one side and a second tessellating shape (say diamonds) on the other. Four block array is shown here usual unit would be nine blocks Diamond half block Metal cables Square half block Metal cables Figure 3. Array of vertically-interlocking blocks. Note the two layers are similar. 639

2.1 Blocks in Arrays Blocks are assembled in arrays that can be overlapped to lock sections of mats together. A very useful array consists of a three-block by three-block unit. If four arrays are laid down in a square, one nineblock array centered in the square will lock all four units below it together (Figure 4). Figure 4. Schematic drawing of four nine-block arrays joined by overlapping the intersection of the array with a fifth identical block array. 2.2 Construction Details The size of the openings between the blocks on the upper side of the lower layer of blocks is controlled by the spacing of the blocks on the cables. The fit of the block from the upper layer into the holes in the lower layer can be varied by specifying the space allowed between the lower blocks as they are cast on the cables (Figure 5). The fitting of the blocks can be facilitated by casting the diamond half of the block with slightly tapered rather than straight sides Figure 5. Nine-block array with an additional block fitted into the opening on the upper surface. Test array is assembled with a clamp cable arrangement to allow the effect of block spacing to be evaluated. 640

3. INSTALLATION OF THE INTERLOCKING BLOCKS Standard subgrade preparation procedures used in horizontally-interlocking block paving procedures are appropriate for the vertical-interlocking paver system (Rollings, 1983; Leong, et al., 2005). Cablerestrained pavers are held in position without an edge restraint or curb that is typically needed for pavers laid as individual units (Portland Cement Association, 1984). Vertically-interlocking pavers are unusual in the each upper paver distributes any load applied to it to four pavers located below it. The arrangement produces lower ground pressure on the sub grade materials below the lower pavers. The end result may be that conventional approaches may produce very conservative designs. 4. BENEFITS OF THE VERTICALLY-INTERLOCKING BLOCKS Vertically-interlocking blocks offer some unusual features: a. The block arrays can be laid without using U-bolts or wire splices. b. The block arrays can be easily lifted and reinstalled at alternate locations. c. Paving can be made permanent by grouting between block arrays and between pavers. d. Each upper paver rests on four lower pavers distributing the force applied to the paver over a broader area of subgrade. e. The design can be modified to include a variety of tessellating shapes on both the top and bottom sections of the blocks. f. All of the usual pigmenting and surface finishing techniques applied to conventional pavers can be used with the vertically-interlocking arrays. 5. CONCLUSIONS Vertically-interlocking paver systems have unique capabilities and many beneficial features that make them attractive for various applications. If conventional paving installation design procedures are used, the resulting pavement may have a longer service life due to the lower pressure on the subgrade. Refinements in design and potentially useful modifications of the installation procedures are expected as the work on this system continues. 6. REFERENCES Leong, P., Tighe, S., and Hein, D., 2005. Best Practice for Concrete Pavers for Canadian Municipal Applications. Paper presented at Transportation Association of Canada Fall, 2005 Meeting. 22 p. Mississippi Department of Transportation, 2002. The US 82 Greenville Bridge across the Mississippi. http://www.greenvillebridge.com/1a1_jan_02.htm. Portland Cement Association, 1984. Structural Design of Pavements Surfaced with Concrete Pavers. Publ. No. IS228.01P. Portland Cement Association Skokie, IL. 8 p. Rollings, R, 1984. Concrete Block Pavements. Tech. Rept. GL-83-3. U. S. Army Waterways Experiment Station, Vicksburg, MS. 121 p. 641

642