Simpson Dura-Vent Engineered Excellence

Similar documents
DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640.

Simpson Dura-Vent Engineered Excellence

DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

DVL. DuraBlack. Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641.

Dur aflex stainless steel

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

APPLICATION AND LISTING

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval.

Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent

DirectVent Pro. Simpson Dura-Vent Engineered Excellence

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 6" - 8", Round and Oval.

Installation Instructions

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Light Stainless Flexible Liner

Ventinox. Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640.

RENDERED TO SLEEPY HOLLOW CHIMNEY SUPPLY, LTD. 85 EMJAY BLVD. BRENTWOOD, NY 11717

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro

Index Rigid Chimney Liner, Flex & Insulation. Section 300. Wood

Installation and Maintenance Instructions

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

Installation and Maintenance Instructions For. Installation and Maintenance Instructions For

Online Update 10/2011 Current Print Version L820 1/2011

Index Rigid Chimney Liner, Flex & Insulation. Section 300. Wood

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Fireplaces and Chimneys

Heavy Duty Flexible Liner

Ovalizing Flexible Liners


Installation Instructions

DuraChimney II Shroud

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR

DuraFlex AL. Installation Instructions

Installation Instructions. Pellet-fuel venting system. PelletVent

Heavy Duty Flexible Liner

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR FLEXIBLE STAINLESS STEEL CHIMNEY RELINING PIPE UL/ULC LISTED SIZES: 3" 12" DIAMETERS.

PIPE

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Heavy Duty Flexible Liner

Flexible Chimney Liners

Installation Instructions. DuraTech 5" - 24" Chimney Shroud. DuraTech Shroud

CHIMNEYS AND FIREPLACES

INSTALLATION INSTRUCTIONS

Technical and Dimensional Data. Saf-T Vent SC

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS

Regency Horizon HZ30E Gas Fireplace

Chimney Lining Systems

CHIMNEYS AND FIREPLACES

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7

Installation Instructions. Air-Cooled, All-Fuel Chimney for Fireplaces. DuraChimney ii

Secure Black. Single and Double Wall Stove Pipe (US) (Canada)

ENGLISH INSTALLATION INSTRUCTION MANUAL. N550 Bakers Oven. CERTIFIED for USA & CANADA SAFETY TESTED to UL & ULC-S

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

Masonry Thimble Chimney Serving Appliance

VERSA-LINER FACTORY-BUILT LINING SYSTEM

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

Installation SBIHA-Black single wall pipe

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

,167$//$7,21,16758&7,216

BuildingName The Description of the Project P DOCUMENTS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

Contemporary Collection

Chimney and Fireplace Inspection Report

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

Taking value to the highest level.

Tested to BS EN and BS EN 1443

Installation and Operation Manual. Safety tested according to ULC-S610 and UL 127 Standards by an accredited laboratory.

P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

Exceptionally strong and flexible Proven durability and long life 20 year warranty CE marked and HETAS approved

Description/Application Maximum Temperature Continuous Firing Maximum Temperature Intermittent Firing Fuel Construction Diameters: Insulation

Flue gas systems for oil and gas condensing boilers. Flue gas kit DN60 rigid in the duct. Accessories DN60 (additionally available to gas flue kit)

Z-Vent Model SVE Series III

Installation Instructions. PolyPro Double-Wall Flex Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro Flex

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

Midtherm Vitrelux flue pipe is available from stock, in the following standard colours and diameters, unless otherwise stated:

B36XTCE Gas Fireplace

O B R O U N D G R E A S E D U C T

Even the sky is no limit.

SI T T FST

TUBINOX. 5", 6", 7" & 8" Dia. INSTALLATION AND OPERATING INSTRUCTIONS. liquid or gaseous fuel burning c 2100 F. ul-1777

Rediflow Concrete Gas Flue System

TOWNSHIP OF FALLS USE & OCCUPANCY FACT SHEET

SI T T FSS/FSTT Open Fire

Sflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: EARTHCORE INDUSTRIES, LLC

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

RECEIVING AND INSPECTION

Sflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

LOPI FIREPLACE INSERT MODEL X INSTALLATION, OPERATION AND MAINTENANCE HANDBOOK. JUNE 1988 Tested to UL 907 (U.S.A.) ULC S628 (Canada)

the heart of a warm home

InoxSabiana 25 Flues. Stainless Steel Double Wall

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

Transcription:

DuraLiner Simpson Dura-Vent Engineered Excellence pplications Materials and onstruction DuraLiner DuraLiner ensures safe and efficient venting of heating appliances, while protecting the masonry chimney from the damaging effects of flue product condensation. It is the only factory-insulated product with zero/zero clearance for high heat wood-burning appliances. No need to uncoil flex, insulate a majority of the pipe, or protect the insulation when installing. smooth inner means less creosote buildup. Installers reduce labor time by 50% or more with DuraLiner. No time wasted wrapping insulation around liner for UL1777 approval. No warping or ovalizing. No investment needed in special equipment or tools or cutting pieces on the job site. learances Diameters Listings Limited-Lifetime Warranty No spacers needed to maintain clearance in tight offsets or dampers. pproved for use in both the US and anada. warranty Limited Lifetime guarantee 86

DuraLiner himney Relining Typical Installations 15 15 Installation Key 15 22 30 or 45 SS Elbow 16 Round Tee with Round ranch 23 Transition nchor Plate 17 DuraTech or DuraPlus himney 24 Two-Ply Insulation Sleeve 18 DuraLiner - rigid length 25 Insulation lamp 19 DuraLiner - flexible length 26 DuraLiner ppliance onnector 20 Masonry Thimble w/ Slip onnector 27 DVL or Duralack Stovepipe 21 Slip onnector and Hanger 18 24 25 22 18 20 16 27 your installation. proper support and bracing. Follow local building codes and have your venting system inspected. 19 Wood Fireplace Wood Stove With Stovepipe Extend--ap Kit 17 DuraLiner Rigid Length 21 23 19 18 26 Insulation lamp Two-Ply Insulation Sleeve (Required only where the flex enters the clay liner of the chimney.) Wood Fireplace Transition To himney DuraLiner Flexible Length 45 Elbow or Stove dapter 87 Simpson Dura-Vent www.duravent.com

himney Relining DuraLiner Planning Your Installation 1 Verify the venting requirements of the appliance used. hoose the liner system appropriate for the appliance and installation. 2 Refer to the Typical Installations for the needed parts for installation. 3 penetrates into the masonry chimney. 4 Determine the length of liner needed. When using DuraLiner, subtract 1 1 2 overlap per joint. 5 6 7 8 Make sure the top of the masonry chimney has a leveled surface to insure a proper fit for the Extend--ap and provide a secure, leak-proof installation. If a free-standing appliance is used, select the vent or stovepipe pieces to connect from the appliance to For Installations using a Transition nchor Plate, refer to the DuraTech, DuraPlus or DuraPlus HT catalogs or installation instructions for proper parts and installation. including clearance to combustibles. ontact the local building inspector for permit requirements. How Size and Height ffect Stove Performance The following design recommendations are intended only as a general guideline to assist in the design and selection of liner components for your installation. Read and follow the DuraLiner installation instructions before installation begins. efore relining a chimney, it should be cleaned and inspected to verify the integrity of the mortar and masonry. This is an important fire safety issue that may have an influence on how the liner is installed. DuraLiner is approved for 0 clearance between the liner and masonry and 0 clearance between the masonry and combustibles. DuraLiner is used for wood-burning appliances when zero clearance or oval pipe is needed. Refer to the appliance manufacturer for installation requirements affecting venting. Keep the vent path as straight as possible for best performance. Restore Deteriorating himneys with DuraLiner When a masonry chimney is damaged or has fallen down, it can be replaced with a safe, factory-built chimney. DuraLiner, when used with a Transition nchor Plate and in combination with DuraTech, DuraPlus, or DuraPlus HT himneys, replaces the damaged masonry chimney with a safe, efficient, and economical chimney that is UL Listed (DuraPlus HT is listed for use in anada). See Typical Installations for details. 800-835-4429 Simpson Dura-Vent 88

DuraLiner himney Relining 30º Stove onnector onnects stove outlets to round or oval DuraLiner pipe at a 30 angle. SIZE ONNETION STOK # 6 Round - Round 4681 8 1 8 9 3 4 5 3 8 6 Round - Oval 4681-RO 9 3 8 7 3 4 5 7 8 6 Oval - Oval 4681-O 15 7 3 8 4 8 Round-Round 4881 10 11 5 8 6¼ 8 Round - Oval 4881-RO 12 1 4 9 3 4 5 7 8 8 Oval - Oval 4881-O 15 7 3 8 4 Flat Stove onnector onnects stove outlets to round or oval DuraLiner pipe. Oval stove connector is sized to easily convert round stove outlets to oval DuraLiner pipe. SIZE STOK # 2 6 ROUND 4680 10 1 4 6 OVL 4680-O -- 8 ROUND 4880 12 1 4 8 OVL 4880-O -- 30º and 45º Stainless Steel Elbows 30 Use as a stove connector to DuraLiner. Features built-in fittings for easy connection to DuraLiner. 30 and 45 elbows are single-wall. SIZE NGLE STOK # 6 30 4630 6 1 2 6 6 45 4645 6 1 2 6 8 30 4830 8 1 2 8 8 45 4845 8 1 2 8 45 89 Simpson Dura-Vent www.duravent.com

himney Relining DuraLiner Round Tee With Round ranch With ap Provides connection between Masonry Wall Thimble or stove connector pipe to round DuraLiner. SIZE STOK # 6 4667 15 1 8 7 1 2 8 8 4867 15 1 8 7 1 2 10 Oval Tee With Round ranch With ap Provides connection between Masonry Wall Thimble or stove connector pipe to oval DuraLiner. Single-wall. May require additional insulation. Refer to DuraLiner installation instructions. SIZE STOK # D 6 14 1 2 6 7 16 4 7 8 8 4867-O 14 1 2 6 7 16 4 7 8 D Spacer Use to maintain a 1 clearance with flex sections of DuraLiner. 3¼ SIZE STOK # 6 OVL 4668-O 8 OVL 4868-O djustable Sleeve from 8 1 2 to 12 8½ to 12 SIZE STOK # 6 4666 8 4866 800-835-4429 Simpson Dura-Vent 90

DuraLiner himney Relining Masonry Thimble with Slip onnector 7¼ - 10 14 Penetrates masonry chimney to allow connection of Duralack pipe or DVL black pipe to DuraLiner. SIZE STOK # 6 4666 8 4866 Wall Pass Through 17 8 10 14 onnects to a DuraLiner tee to bring DuraLiner through a masonry chimney and a combustible wall. llows the connection of Duralack pipe or when used with the appropriate adapter. DVL black pipe will connect directly to the Wall Pass Through. SIZE STOK # 6 4644 6 1 2 8 4844 8 1 2 Round-To-Round Heavy Duty Flex Pipe construction. Use through damper and smoke shelf area. Features built-in fittings, which eliminates field cutting and fitting. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # 6 6DL-36OF 7 3 6 6DL-60OF 7 3 8 8DL-36OF 10 3 8 8DL-60OF 10 3 91 Simpson Dura-Vent www.duravent.com

himney Relining DuraLiner Round-To-Round Flex Pipe Use through damper and smoke shelf area. uilt from 304 stainless steel. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # 6 4636-F 6 5 8 6 1 6 4660-F 6 5 8 6 1 8 4836-F 8 5 8 8 1 8 4860-F 8 5 8 8 1 Oval-To-Oval Heavy Duty Flex Pipe Oval-to-Oval Flex pipe built from.016", 304 stainless steel, 4-ply construction. Use through damper and smoke shelf area. Features built-in fittings, which eliminates field cutting and fitting. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. 4¾ SIZE STOK # 6 6DL-36OF 7 3 6 6DL-60OF 7 3 8 8DL-36OF 10 3 8 8DL-60OF 10 3 Oval-To-Oval Flex Pipe Use through damper and smoke shelf area. uilt from 304 stainless steel. Use with DuraLiner Two-Ply Insulation Sleeve for zero clearance applications where flex extends into clay liner. 4¾ SIZE STOK # 6 4636-OF 7 3 6 4660-OF 7 3 8 4836-OF 10 3 8 4860-OF 10 3 800-835-4429 Simpson Dura-Vent 92

DuraLiner himney Relining Oval-To-Round Heavy Duty Flex Pipe Oval-to-Round flex pipe built from.016", 304 stainless steel, 4-ply construction. Use through damper and smoke shelf area. Use to connect from oval stove outlet to round DuraLiner. Use with DuraLiner Two-Ply insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # 6 6DL-36ORF 7 3 4 6 1 6 6DL-60ORF 7 3 4 6 1 8 8DL-36ORF 10 3 4 8 1 8 8DL-60ORF 10 3 4 8 1 4¾ Oval-To-Round Flex Pipe Use through damper and smoke shelf area. Use to connect from oval stove outlet to round DuraLiner. uilt from 304 stainless steel. Use with DuraLiner Two-Ply insulation Sleeve for zero clearance applications where flex extends into clay liner. SIZE STOK # 6 4636-OR 7 3 4 6 1 6 4660-OR 7 3 4 6 1 8 4836-OR 10 3 4 8 1 8 4860-OR 10 3 4 8 1 4¾ Round-To-Oval Flex Pipe Use as a stove connector from a round stove outlet to oval DuraLiner. uilt from 304 stainless steel. Use with DuraLiner Two-Ply insulation Sleeve for zero clearance applications where flex extends into clay liner. 4¾ SIZE STOK # 6 4614-RO 6 1 2 7 3 4 8 4814-RO 8 1 2 10 3 4 14 93 Simpson Dura-Vent www.duravent.com

himney Relining DuraLiner Round Rigid Pipe vailable in 6 and 8 diameters in 12, 24, 36, and 48 lengths. Factory insulated. uilt-in, pre-drilled fittings for riveting joints. UL Listed for zero clearance between masonry and combustibles, plus zero clearance between liner and masonry. 304 stainless steel inner and aluminized steel outer. SIZE STOK # 6 4612 6 5 8 6 1 2 12 6 4624 6 5 8 6 1 2 24 6 4636 6 5 8 6 1 6 4648 6 5 8 6 1 2 48 8 4812 8 5 8 8 1 2 12 8 4824 8 5 8 8 1 2 24 8 4836 8 5 8 8 1 8 4848 8 5 8 8 1 2 48 Oval Rigid Pipe Factory insulated, Oval Rigid Pipe is available in 6 and 8 diameters; 12, 24, 36, and 48 lengths. Insulated. uilt-in pre drilled fittings for riveting joints. UL Listed for zero clearance between masonry and combustibles, plus zero clearance between liner and masonry. 304 stainless steel inner and aluminized steel outer. 4¾ SIZE STOK # 6 4612-OP 7 3 2 12 6 4624-OP 7 3 2 24 6 4636-OP 7 3 6 4648-OP 7 3 2 48 8 4812-OP 10 3 2 12 8 4824-OP 10 3 2 24 8 4836-OP 10 3 8 4848-OP 10 3 2 48 Extend--ap Kit ap Storm ollar Support lamp ase Plate Terminates DuraLiner at the top of the masonry chimney. Kit includes ase Plate, Support lamp, Storm ollar, and ap (with spark arrestor). Pipe not included. SIZE STOK # 6 4685 13 13 6 4686 13 18 6 4688-O 13 20 6 4687-O 10 22 8 4885 13 13 8 4886 13 18 8 4886-O 13 20 8 4885-O 10 22 800-835-4429 Simpson Dura-Vent 94

DuraLiner himney Relining Slip onnector and Hanger Slip onnector Hanger Use with Transition nchor Plate to transition from DuraLiner to DuraTech, DuraPlus, or DuraPlus HT chimney. 14 Slip onnector. SIZE STOK # 6 4671 8 4871 Transition nchor Plate Use with Slip onnector and Hanger in chimney restoration to connect DuraLiner pipe to DuraTech, DuraPlus, or DuraPlus HT himney. DURPLUS HT D himney Section Slip onnector Transition nchor Plate DuraLiner System SIZE STOK # D 6 9040 6 1 8 17 14 6 9040 6 1 8 17 17 6 9040 6 1 8 21 13 6 9040D 6 1 8 21 17 8 9240 8 1 16 12 3 8 17 14 8 9240 8 1 16 12 3 8 17 17 8 9240 8 1 16 12 3 8 21 13 8 9240D 8 1 16 12 3 8 21 17 DURTEH SIZE STOK # D 6 9440 6 1 16 8 3 16 17 14 6 9440 6 1 16 8 3 16 17 17 6 9440 6 1 16 8 3 16 21 13 6 9440D 6 1 16 8 3 16 21 17 8 9640 8 1 16 17 14 8 9640 8 1 16 17 17 8 9640 8 1 16 21 13 8 9640D 8 1 16 21 17 95 Simpson Dura-Vent www.duravent.com

himney Relining DuraLiner Two-Ply Insulation Sleeve Use with DuraLiner round and oval flex lengths above the first clay flue tile to meet UL 1777 standards. (Use to meet zero-clearance requirements between the DuraLiner length and the inside of the chimney, and, the outside combustibles above the first clay flue tile.) Features high-temperature blanket insulation with an abrasion resistant fabric cover. Use with Insulation lamp (below). SIZE STOK # 5-6 7102-Z 7-8 7104-Z Insulation lamp Fits round or oval up to 8. Universal No bolt or steel protrusions minimizes snagging. Toggle action provides fast, secure fit. SIZE STOK # Universal 4910 800-835-4429 Simpson Dura-Vent 96