ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

Similar documents
ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY

automatic regulation of mixture richness way to emission decrease is in standard equipment of CHP unit

INdoor MGM 200 Natural Gas - emissions NOx < 500 5%O2. Type Specifications Co-generation Unit with MAN Gas Engine

UFL Micro Biogas CHPs

TECHNICAL DETAILS INDOP220MB

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

WHAT S INSIDE 11 TECHNICAL INFORMATION 18 HYDRAULIC PRINCIPLE DRAWINGS 20 BUFFER VESSELS 23 TECHNICAL SUPPORT 23 DECLARATION OF COMPLIANCE

Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS

ABB MEASUREMENT & ANALYTICS DATA SHEET. SCK Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit

b) General instructions and documents to be submitted by an interested company:

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Air Cooler Industry AC-MS Modular Systems

UltraGas. Technical Data Output range 15 to 2000 kw. Condensing Gas Boiler /02-07/15 Subject to modifications

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Combustion Laboratory Unit C492

BUILDINGS & OFFICE SPACES INDUSTRIAL SOLUTIONS. Combined production of Heat and Power. Waste Heat Recovery Bottoming Cycle

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

PRODUCT DESCRIPTION PARAMETERS

EUROPE S LEADING CHP SPECIALIST. Dachs CHP RANGE GUIDE 2016

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

PowerBloc EG. Technical Information and Installation Manual Output range 43 to 532 kwe. Combined Heat and Power

YANMAR s 35 kw Combined Heat and Power System.

GET Turbine Generator

Low Temperature Check. Automatic instrument for the determination for both TR TEST and BRITTLENESS POINT

2G. Product portfolio.

HITACHI Modular Chiller Solutions

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

do more with less Mini-Cogeneration Your declaration of independance : generate your own power and heat efficiently

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

CCR3 Controller - return temperature controller & temperature registration

LSA Rating Table Low Voltage Alternators - 4 pole

Largo & Allegro. Air Compressors. Largo & Allegro

MODULATING CONDENSING BOILER WITH LOW NOX PREMIX BURNER FOR OUTDOOR INSTALLATION (IPX5D) OUTPUT RANGE from 99.5 to 920 kw in battery (115kW x8)

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

oil cleaner Electrostatic Product brochure

Miniature I/P, E/P Transducer

FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS

Thai-German Technology Conference Biogas CHP Solutions / exhaust gas heat recovery - GTP Solutions GmbH (D) Bangkok, Hotel Crowne Plaza

Siemens gas engine portfolio siemens.com/engines

A LTERNATIVE E NERGY D IVISION HIGH PERFORMANCE COGENERATION SYSTEMS FOR AGRICULTURE AND INDUSTRY

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2

PAHT C pumps ATEX PAHT C pump

CONTINUOUS GAS POWER GENERATION

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

CONDENSING BOILERS EX3 & 6. Floor Standing Gas Fired. Condensing Boilers. Condensing 69kW 542kW. Cascading options up to 8,672kW

Pump down time for 5 l receiver

Renewable energies Concepts Heat exchanger solutions. Experts for energy recovery. We make waste-heat to your profit

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

Combustion Laboratory Unit C492

3363 en / e

OIL-INJECTED ROTARY SCREW COMPRESSORS. G ( kw / hp) / G VSD ( kw / hp)

madur GA21p-EN-v portable gas analyser

Report on thermal cooling system implementation and performance

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Stationary Gas Analysis System Goliath for bio methane, landfill gas, sewage gas, mine gas and biogas

THE ENERGY ENGINEERING COMPANY. E²CON-GE ENGINE CONTROLLER Retrofit system based on openecs for modernizing GE Jenbacher gas engines.

Spirax EasiHeat TM HTG (Steam Side Control) EN Heating System Compact Heat Transfer Solution

SCK Sampling System for Dry Gas Sampling at Rotary Cement Kiln Gas Exit and Calciner Gas Exit

Reliable, low-maintenance process heating

MCW 5-39 kw. Indoor monobloc unit. Water chillers and heat pumps MCW PLUS. Compact single circuit units. 242 galletti.

Stack Parking Surface Mounted Stackers

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Servo-hydraulic Universal Testing Machine HUT Type B

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Air Cooler Industry OSCA / OSCAF 0-3

Gitie. A CHOICE SMARTER than solar systems. Trivalent integrated outdoor package

Product range. Product range

GAS 3050P NDIR FLUE GAS

EQUIPMENT APPEARANCE. madur. portable gas analyser

QGO Oxygen Sensor. Building Technologies HVAC Products

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

Advanced Mechatronics System (AMS)

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

DRY COOLERS CERTIFY ALL DRY COOLERS

The Ecomax Greenhouse solution brings savings, efficiency and sustainability to greenhouses. greenhouse power netherlands a Company of Gruppo AB

CAT CG132. Series Gas Generator Sets

General Plan OXYGEN SERVICE CONTAINER 2005 Version 1.02

Heated FID OVF Portable THC/TVOC Analyzer

PMx Sequential Samplers Giano & Gemini

Ion exchange Unit IXU 1/4 Series

LUBRICATION PUMP Z2 CENTRAL LUBRICATION

( ppm ) ( ppm ) ( ppm ) History :46:43

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

Transcription:

CHP Technical Data Sheet for T80 Natural Gas Containerised Cento Series Standard Features High performance electrical efficiency Fully modulating output 3 packages Open frame, Indoor Canopy, Outdoor Container Sophisticated web remote monitoring Bosch engine management The Cento series benefits from having Tedom s own built in-house high performance gas engines. Available to run on a variety of gas fuels. Multiple units can be run in synch, and high-end digital controllers make synchronising with the mains simple. Long service intervals 27 month warranty Standby power options Low noise options ELECTRICITY OUTPUT THERMAL OUTPUT ELECTRIC EFFICIENCY THERMAL EFFICIENCY TOTAL EFFICIENCY 81 kwe 120 kwt 35.1 % 52.2 % 87.3 % shentongroup has the exclusive distributorship for Tedom products in the UK, Ireland and Channel Islands. We provide dedicated services for CHP projects, ranging from design assistance, through project management, to commissioning and long-life support. Tedom is a global CHP manufacturer with 600 employees. There are over 2,000 Tedom CHP units in service in over 35 countries worldwide.

Cento Series Features The TEDOM Cento T series of CHP units are machines of medium outputs, within a range of outputs from 80 to 200 kwe. The block arrangement of these units contains engine-generator set, heat installation, exhaust silencer and electric switchboard with power and control parts. They are intended for gas fuels, and in container version are intended for outdoor installation. TEDOM CHP Unit Merits: Automatic air-fuel ratio control - this method of reducing emissions is in the standard supply of CHP unit. CHP units are fitted with BOSCH engine-management which optimises engine operation. CHP units form easily connect-able compact complex. By use of containerised enclosure, CHP units are characterized by low noise output and protected against external conditions. Ability to adapt to different temperature gradients of heating systems. Due to modular arrangement of control system, the number of binary and analogue inputs for monitoring and controlling following devices can be extended easily. Basic signals for CHP unit control (external emergency stop, external start, etc) can be connected to the customer s terminal box. Units are functionally tested for operation in production plant. TEDOM CHP units are continuously innovated from the knowledge of previous projects. By decision of Notified Body 1015*, certificate E-30-01048-10 was issued, to confirm the compliance of the Cento series with the requirements of Directive 2009/142/EC (Government Decree No. 22/2003 Coll.). TEDOM is also the holder of QMS and EMS Quality Management Certificates. In terms of tests performed on the control switchboard, the Electrotechnical Testing Institute, Certification Body No. 3018, accredited by Czech Accreditation Institute, granted certificate according to ČSN EN 45011. Amongst others, the product is also certified for EAC countries and Ukraine. * Machinery Testing Institute, Brno, Czech Republic. Design Operation Fuel Containerised SP - synchronous, parallel with mains Natural gas Basic Technical Data Nominal electric output 81 kw Maximum heat output 120 kw Load 50 75 100 % Heat output 82 99 120 kw Fuel input 141 183 231 kw Electrical efficiency 28.8 33.1 35.1 % Heat efficiency 58.6 54.2 52.2 % Total efficiency (fuel use) 87.4 87.3 87.3 % Fuel consumption 14.9 19.4 24.4 m 3 /h Basic technical data above is valid for standard conditions according to the Technical Instructions document. The minimum permanent electric output is 50% of nominal output. Gas consumption is expressed under standard conditions (15 C, 101,325 kpa). Emissions Emissions CO NOx At 5% O 2 in exhaust gas 650 mg/nm 3 500 mg/nm 3 Generator Model Manufactuer LSA 44.3 L10 LSA 44.2 L12 Leroy Somer Cos 1.0 Efficiency in working point 94.9 % Voltage Frequency 400 V 50 Hz TS_Cento T80_NG_C_H06 2

Engine Model TG 85 G5V NX 86 Manufacturer Tedom Number of cylinders 6 Arrangement of cylinders In Line Bore stroke 130 150 mm Displacement 11946 cm 3 Compression ratio 12 : 1 Primary Circuit: This is the internal closed pressure circuit, which takes heat from engine water jacket and exhaust gases and passes it into the secondary circuit. If this circuit s thermal output cannot be removed in marginal modes of operation, this output or its part can be removed by dry cooler for emergency cooling, which can be also supplied. Heat output of circuit Maximum working pressure 120 kw 250 kpa Water volume in CHP unit circuit 200 dm 3 Speed Oil consumption normal / maximum Maximum output of engine TG 85 G5V NX 86_850; Revision C: 10.1.2013 1500 rpm 0.3 / 0.5 g/kwh 86 kw Fuel, Gas Inlet Fuel type Natural Gas Heat value 34 MJ/m 3 Minimum methane number 80 Thermal System In terms of heat output extraction, the CHP unit s heat output is generated by the secondary circuit. Secondary Circuit: This circuit is used to deliver the main heat output of the CHP unit to the heating system. Secondary circuit transfers heat from the primary circuit. Observance of the maximum permissible return water temperature is essential for troublefree operation of the unit. Parts of secondary circuit located outdoors (interconnection pipe) must be protected against freezing. The circuit is not equipped with circulating pump. The heating water to charge the hydraulic circuits must be treated, its composition must correspond to the Technical Instructions document. In case CHP unit is shut down for the heating season, the circuit s external parts must be protected against freezing. Heat carrier Heat output of circuit Water 120 kw Gas pressure Maximum pressure change under varying consumption 5-10 kpa 10 % Maximum gas temperature 35 C CHP units can be operated on natural gas, biogas, propane and landfill gas (the fuels can be further modified as agreed with the technical design department). The limit parameters of biogas and other fuels that limit their fitness for use are given in the Technical Instructions document. The CHP unit s gas route is constructed in conformity to TPG 811 01 and contains a set of two independent quick-closing electromagnetic valves to shut off the gas inlet when the CHP unit is turned off, gas pressure zero regulator and metal hose for connection to mixer. Gas filter is installed for biogas applications. Gas connection of suitable size with adequate accumulation volume is required for the correct operation of CHP unit, to avoid gas pressure decrease in distribution system at the moment of incremental gas off-take. This gas connection will be terminated by manual gas stop and fitted with a pressure gauge. Nominal water temperature inlet / outlet 70 / 90 C Temperature of return water min / max 40 / 70 C Nominal flow rate Maximum working pressure 90 l/min 600 kpa Water volume in CHP unit circuit 30 dm 3 Pressure loss at nominal flow rate 25 kpa Nominal temperature drop 20 C TS_Cento T80_NG_C_H06 3

Combustion & Ventilation Air The unusable heat (radiated from hot parts of the CHP unit) is removed from the container by forced air ventilation, which enters the unit in the inlet port on the container roof. Ventilation air leaves the container through the ceiling port in the opposite area. The flow of ventilation air is ensured by the fan. Both Inlet and outlet openings of the ventilation system are fitted with rain protection canopies and the air-conditioning flap with actuator. Part of the air inside the container is separated from ventilation air and used as combustion air. Electric heating elements are installed for temperature treatment of the container interior. These elements will allow temperature treatment during CHP unit shut-down in the heating season, to ensure the temperature inside the container doesn t fall below the minimum necessary to start the enginegenerator. Unusable heat removed by ventilation air 16 kw Outdoor air temperature min / max -20 / 35 C Quantity of combustion air 358 Nm 3 /h Exhaust Gas & Condensate Outlet Combustion products exit from the CHP unit through the outlet exhaust conduit connected to exhaust silencer s outlet flange. Exhaust silencer is placed on the container roof. Exhaust gases can be removed as required into suitable stack through an exhaust conduit, or can leave directly into atmosphere. The linked exhaust conduit (if used) must be inclined away from the unit. Exhaust gas quantity 379 Nm 3 /h Exhaust gas temperature nominal / maximum Maximum back-pressure behind CHP unit flange Exhaust gas speed at outlet (DN 100) 120 / 150 C 10 mbar 19.3 m/s Electrical Parameters Nominal voltage Nominal frequency 230 / 400 V 50 Hz Power factor (1) 0.8 Nominal current at cos =0.8 Generator circuit breaker Short-circuit resistance of switchboard Contribution of the actual source to shortcircuit current Power switchboard protection closed/opened Control switchboard protection closed/opened Recommended superior circuit breaker Recommended connection cable (2) (length <50m, at temperature <35 C) 146 A NSX160B 3P 20 ka < 1.5 ka IP 31/00 IP 31/00 200 A NYY-J 3 95+50 (1) Power factor adjustable from 0.8C - 1-0.8L (range from 0.8C - 1 must be verified according to the various types of generators). L = inductive load - overexcited C = capacitive load - underexcited Operation of the generator with a power factor of less than 0.95 causes a power limitation sets the following table: Power factor [-] 1 0.95 0.8 Output [% Pnom] 100 100 98 (2) The stated cables are for information only. A check calculation for temperature rise and voltage drop must be made according to the actual length, placement and type of cable (maximum allowed voltage drop is 10 V). Lubricants Quantity of lubricating oil in engine 56 dm 3 Volume of replenishment oil tank 125 dm 3 Noise Parameters Noise parameters indicate the acoustic pressure level measured in free field conditions. Determination of measuring point and method of evaluation comply with ČSN 09 0862 and ČSN EN ISO 3746. The noise may contain a tone component. CHP unit 10m from container 62 db(a) TS_Cento T80_NG_C_H06 4

Switchboard Design The electrical part of the CHP unit is located in sheet-steel switchboard that includes both the power and control parts. Power Switchboard Contains: Generator circuit breaker, which protects generator and part of power line against over-current and short circuit. Generator contactor that is used as a switching component for synchronizing generator to mains. XV terminal for connecting the power cable. XG terminal for connecting the generator. Current measuring transformers. Control Switchboard Contains: Central part of the control system, and any extension modules. Protecting and switching components. Controlling components for maintenance purposes. 24VDC power supply. Terminals for connecting analogue sensors, binary switches, controlled devices, remote communication etc. Customer terminal box. Control System Control of the CHP unit is enabled by ProCon Sight control system, which allows fully automated operation. It is a multiprocessor modular system, consisting of the control unit, display unit and extension modules with analogue and binary inputs and outputs. Due to colour display with high resolution, plus the context and navigation buttons, the display unit provides easy access to all data about gen-set, monitored values, and time trends of these values. ProCon Sight display unit can communication in up to seven languages, one of which can be graphical (e.g. Chinese, Korean). Main Features of Display Unit: Large 8 colour TFT display with 800 600 pixel resolution. Easier and faster operation by using the context buttons. Permanently displayed status bar. Time history display of selected values - graphs. Clearer history display. Windows CE operating system. Measured Values The control system measures and evaluates following values: Electrical Values: 3 generator voltage 3 generator current 3 mains voltage Listed Electrical Values Are Used For: Evaluation of the mains parameters. Automatic synchronization of generator to mains. Calculations and evaluation of required electrical values. Technological Values: CHP unit is equipped with set of binary and analogue sensors that monitor all the necessary processes to optimize them. Optimization is performed by the relevant outputs in control of relevant applications. Operation Methods Local: By buttons located on the display unit. Remote (on request): By voltage-free contacts (external timer, superior control system etc.) According to the required power level or building consumption level. From local or remote PC. Via SMS messaging. Building Consumption Control (on request): The system obtains information on the building consumption from the converter which measures direction and size of the demand/supply from/to the mains. Required Power Control (on request): By analogue signal - e.g. 0/4-20mA Via data path - e.g. MODBUS-RTU protocol. TS_Cento T80_NG_C_H06 5

Gen-set Operation Monitoring From Local PC - Connection Possibilities: RS232 RS485 USB From Remote PC - Connection Possibilities (on request): Analogue modem GSM modem Internet Via SMS Messaging (on request) Colour Design Engine, generator and internal parts of unit Container RAL 5015 (Blue) RAL 5013 (Blue) Dimensions & Weight Information Length Total / Transport Width Total Height Total / Transport Operational weight of CHP 5400 / 5000 mm 2500 mm 6800 / 2660 mm 8265 Kg Additional Documents Dimensional drawing of CHP: Cento T80-T120 Containerised GA Drawing_ R1262. P&ID: Cento T80 Containerised P&ID_S0497A. Generally binding source materials according to the Technical Instructions document. Amendments Due to our policy of continual improvement, we reserve the privilege to change this document and consequential documents without notice. TS_Cento T80_NG_C_H06 6