Evidence of Performance Thermal transmittance

Similar documents
SUNCE Marinkovic d.o.o. Lepenicki bulevar br Kragujevac Serbia. Hollow chamber profile - plastic Profile combination: Casement-frame

Evidence of Performance Calculation of thermal transmittance

Evidence of Performance Calculation of thermal transmittance

Evidence of Performance Burglar resistance

according to Section 4.2 heroal-johann Henkenjohann GmbH & Co. KG Österwieher Str Verl Germany Window system heroal W65

Evidence of Performance

Evidence of Performance. Class 4. Class E900. Class C3 / B3. Test Report No PR02. DOMIS d.o.o. Miokovci bb Cacak Serbia

Evidence of Performance Joint sound reduction of filling material

Evidence of Performance Airborne sound insulation of building components

WEEDOO - SA CONSTRUCTION TECHNOLOGY

Classification report Airbourne sound insulation of building elements

*) This is a translation of Test Report dated 07 August Window system M 9400 SOFTLINE PLUS Frame material: Aluminium

Evidence of Performance Joint sound reduction of filling material

OPTIWIN MOTURA. Technical Description. Synopsis:

TEST REPORT EN : A1:2010

Pilkington Reglit. Technical Information on Pilkington Reglit Profiled Glass with System. - English Edition -

Leak Tightness of Jointing. 1. Basic Principles

A Guide To: Weatherseal selection & specification in Europe. Ensuring Superior performance

Production Technology

Report for the U-value of a Door System in Accordance with BS EN ISO :2006. Product description:

OPTIWIN PURISTA. Technical Description. Synopsis:

DECLARATION OF PERFORMANCE

Advantages of upvc Windows & Doors. M. Hommernick 1

DECLARATION OF PERFORMANCE

Where Artistry meets performance. Performance PVC Line

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

Evidence of Performance Joint sound reduction of filling material

Kingspan KS1150 FR Product Data Sheet

PVC-U: Innovations and product ranges

FRAME AND SPACER MATERIALS

GRP Panels. PANOLIT - CPR Plywood core coated on both sides with glassfibre reinforced polyester resin. Thicknesses and Weights

Fire resistance according to EN :2008 of a Sectional door set, type Metacon OHD EI(1)-60

4257M METALCRAFT INSULATED PANEL SYSTEMS

Steel Fire-Rated Doors to British Standard. Single and double-leaf doors in a matching appearance - with Environmental Product Declaration EPD

Cold Rooms Kide

Narrow Cavity Insulating Glass Units (IGU s) with Reduced Spacer-bar Sightlines

Kingspan KS1150 FA Product Data Sheet

Now our house. saves soooo. much energy! T h e N e w G e n e r a t i o n Energy Saving. S y s t e m. The Quality Profile

Steel Fire-Rated Doors to British Standard. Single and double-leaf doors in a matching appearance - with Environmental Product Declaration EPD

EXTERIOR DOORS And doorsets

KS1000 FH Product Data Sheet

M I N I C O L D R O O M TECHNICAL SPECIFICATIONS

DECLARATION OF PERFORMANCE

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Płyty warstwowe. Sandwich Panels

DECLARATION OF PERFORMANCE

Evidence of Performance regarding the requirements for float glass according to EN 572

Openings in Sandwich Panels. Prof. Dr.-Ing. Jörg Lange Dr.-Ing. Lars Heselius

7520 Casement Windows

TEST REPORT ASTM E331. Report No.: E Rendered to: IMISON USA Houston, Texas

ENGINEERED FAÇADE SYSTEM FAÇADE SYSTEMS

TM 1020:2017. Determination of the long term Thermal Conductivity of an OCF 1 Canister Foam

Płyty warstwowe. Sandwich Panels

TEST REPORT FIRES-FR AUNE. Single side-hung lift landing semiautomatic door, thermally insulated with polyurethane

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Sectional Overhead Doors SECTIONAL OVERHEAD DOORS

Series PV. Compact Switchgear Cabinets. Construction subject to change without notice Dimensions in mm

FIRE RESISTANCE EXPERT JUDGEMENT REPORT WITH CLASSIFICATION FIRES-JR NURE. Fire resistance shutter with retractable stairs, type LMF

your smart energy MODERN INSULATION VERSATILE APPLICATION Gain more energy. Enjoy life!

European Timber Windows & Doors

EUROPANEL Construction System

FOAM SEALANT STRIPS GLAZING TAPES JOINT BACKING RODS

TPS Thermo Plastic Spacer

heroal W 77 HI Window systems

REPORT No.: Page 1 of SCHIMATARI VIOTIAS, GREECE REF. «REFLECTIX»

This document is a preview generated by EVS

Certified Passive House Components: Spacers in Low-e Glazing Version 0.32, kk

PREFAB HOUSES EZ-GROUP

9 Miscellaneous Changes in Packaging Units Catalogue Change Service Info-Point Nr. 45 July 2014 Page 1 of 15

SOUTH AFRICAN NATIONAL STANDARD

Fixed Skylight / Fixed Multiple Skylight Milgard Aluminum Window

Wall Energy Rating Impact of Air Leakage on Energy Performance

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Refurbishment site guidance for solid-walled houses windows and doors

Building Your Visions

The next generation windows a new source of energy (reduction)

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

PRESS RELEASE

Building & Ductwork Airtightness Standards

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Performance Standards of Glass Products Manufactured by Pilkington IGP

ADVANCE METAL INDUSTRIES L.L.C.

ASF FR Board PRO RANGE Coated Mineral Wool Board for the Professional

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

DOORS ENTRY DOORS TECHNICAL MANUAL

Folly or innovation suggestions for a sensible approach to the U-value Olympics

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

Tehnical Data Sheet Astro X-Series CE Pipe Wrap. UIC of product-type: XSPW CPR-JA5085 ETA-15/0619. ETAG 026-Part 1 ETAG 026-Part 2

All Seasons Door and Window, Inc. SIMULATION PERFORMANCE & SOLAR HEAT GAIN REPORT. V700 Vertical Slider Double Hung NCTL

MGM Industries SIMULATION PERFORMANCE & SOLAR HEAT GAIN REPORT. Series 8010 Picture Window NCTL

Justifiability Installation of New Types of Window

Cleanroom Systems UltraTech

Coupled windows in the current guise

SECTIONAL OVERHEAD DOORS

Thermo 74 Windows, French doors, and Terrace doors with low U-values

This classification report consists of five pages and may only be used or reproduced in its entirety.

S S 9000 GEALAN s new system platform SYSTEMATIC INNOVATION

MGM Industries Inc. SIMULATION PERFORMANCE & SOLAR HEAT GAIN REPORT. Series 5600 Single Hung NCTL

Use of Phase Change Materials for Thermal Comfort and Electrical Energy Peak Load Shifting

Transcription:

Evidence of Performance Test Report No. 15-004068-PR04 (PB 02-K20-06-en-01) Client Product Results OKNOPLUS Sp. z o.o. ul. Zgodna 55 30-444 Kraków - Libertów Poland Plastic profile, profile combination: frame - casement Designation THERMO S 8000 Performance-relevant product details Plastic - Polyvinylchlorid (PVC-U) rigid; Projected width in mm 116; Frame member; Profile section, width in mm 66; Profile section, depth in mm 74; Reinforcement; Metal steel galvanized; Inlay foam; Rigid polyurethane foam Purex WG-2132 ; Density in kg/m³ 40 (nominal value); Width in mm 24; Depth in mm 26; Casement member; Profile section, width in mm 78; Profile section, depth in mm 85; Reinforcement; Metal steel galvanized; Inlay foam; Rigid polyurethane foam Purex WG-2132 ; Density in kg/m³ 40 (nominal value); Width in mm 28; Depth in mm 42; Inlay foam of glazing rebate; Flexible polyurethane foam NOMATEC XPE038 ; Density in kg/m³ 25 (nominal value); Width in mm 9; Depth in mm 45; Replacement panel; Edge cover in mm 15; Thickness in mm 44 Special features -- ift Rosenheim 29.03.2016 U f = 1.1 W/(m²K) Basis *) EN 14351-1:2006+A1:2010-03 EN 12412-2:2003-07 *) Correspond/s to the national standard/s (e.g. DIN EN) ift - test report 15-004068-PR04 (PB01-K20-06-en-01) dated 23.03.2016 Representation Instructions for use 78 The results obtained can be used by the manufacturer for preparing the Declaration of Performance in accordance with the Construction Products Regulation 305/2011/EU. The provisions of the applicable product standard have to be observed. Validity The data and results given refer solely to the described and tested specimen. Notes on publication The ift-guidance Sheet "Conditions and Guidance for the Use of ift Test Documents" applies. The cover sheet can be used as abstract. Contents The report contains a total of 6 page/s and annex (1 page). 9 15 Ve-PB0-2203-en (01.10.2012) 44 85 Manuel Demel Deputy Head of Testing Department Building Physics Konrad Huber, Dipl.-Ing. (FH) Operating Testing Officer Building Physics

Evidence of Performance Page 2 of 6 1 Object 1.1 Description of test specimen Product Manufacturer Plastic profile, profile combination: frame - casement Original client Date of manufacture 4.12.2015 System designation THERMO S 8000 Projected width in mm 116 Frame member Shipping name / Type / Item number 8001 Profile cross section, width in mm 66 Profile cross section, depth in mm 74 Reinforcement Shipping name / Type / Item number -- Profile cross section, width in mm 28 Profile cross section, depth in mm 28 Profile cross section, thickness in mm 2 Inlay Foam of reinforcement Density in kg/m³ Thermal conductivity in (W/mK) Width in mm 24 Depth in mm 26 Casement member Shipping name / Type / Item number 8068 Profile cross section, width in mm 78 Profile cross section, depth in mm 85 Reinforcement Shipping name / Type / Item number -- Profile cross section, width in mm 28 Profile cross section, depth in mm 28 Profile cross section, thickness in mm 2 Inlay Foam of reinforcement Density in kg/m³ Thermal conductivity in (W/mK) Plastic - Polyvinylchlorid (PVC-U) rigid Metal steal galvanized Rigid polyurethane foam Purex WG-2132 (data sheet version 2008-06-03, POLYCHEM SYSTEMS Sp. z o.o.) 40 (nominal value) 0.022-0.025 (nominal value) Metal steal galvanized Rigid polyurethane foam Purex WG-2132 (data sheet version 2008-06-03, POLYCHEM SYSTEMS Sp. z o.o.) 40 (nominal value) 0.022-0.025 (nominal value)

Evidence of Performance Page 3 of 6 Width in mm 28 Depth in mm 42 Inlay Foam of glazing rebate Density in kg/m³ Thermal conductivity in (W/mK) Width in mm 9 Depth in mm 45 Rebate design Replacement panel Edge cover in mm 15 Thickness in mm 44 Flexible polyethylene foam NOMATEC XPE038 (ift test report 10-001118-PB01-K05-06-de-01, dated 2010-11-02) 25 (nominal value) 0.038 (nominal value) 1 rebate seal in frame member 1 overlap seal in casement member The description is based on specifications provided by the client and on inspection of the test specimen at the ift. (Item designations/ numbers as well as material specifications were provided by the client, unless designated as ift-tested.) Test specimen are described in the annex "Product/Sample description". 1.2 Sampling The following data for sampling have been presented to ift: Sampler: Original client Documentation: ift Rosenheim did not receive a sampling report. Date of delivery: 15.12.2015 ift-test specimen-no.: 15-004068-PK03 / WE: 41005-005, WE: 41005-006, WE: 41005-007, WE: 41005-008

Evidence of Performance Page 4 of 6 2 Procedure 2.1 Basic documents *) of the processes EN 12412-2:2003-07 Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2 Frames EN 14351-1:2006+A1:2010-03 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics *) correspond/s to the national standard/s, e.g. DIN EN ift - test report 15-004068-PR04 (PB01-K20-06-en-01) dated 23.03.2016 2.2 Short description of process The test is performed according to the regular hot box. The thermal transmittance is determined in steady state. The specimen is located in a wall of insulation, which is surrounded by two half shells and the interior and exterior space. Air and surface temperatures as well as the heating power are measured.

Evidence of Performance Page 5 of 6 3 Detailed results

Evidence of Performance Page 6 of 6

Attachment 1: Product illustration Page 1 of 1 Evidence of Performance 9 15 78 Ve-PB5-3316-en (01.07.2013) 44 85 Figure 1: Cross section of the profile