Sag Pipe (depressed sewers, or Inverted siphons) Dr. Sataa A. Al-Bayati(10-11)

Similar documents
Wastewater Collection System

بسم هللا الرحمن الرحيم

Learning objectives. Upon successful completion of this lecture, the participants will be able to:

CEE 371 Water and Wastewater Systems

Basics of Wastewater Collection System

Sewer system- Design Criteria

Design of Sewerage System for Jaffarpur area in Southwest New Delhi

Sanitary Sewer Design. Sanitary Sewers, Page 1

ENGINEERING REVIEW CHECKLIST City of Mount Clemens

Facilities Development Manual

DESIGN OF SEWER SYSTEMS

WASTEWATER & STORM WATER COLLECTION AND REMOVAL

L3. Design Criteria of wastewater collection system

WASHOE COUNTY DEPARTMENT OF WATER RESOURCES GRAVITY SEWER COLLECTION DESIGN STANDARDS

SEWER SYSTEM DESIGN GUIDELINES

APPENDIX G HYDRAULIC GRADE LINE

Water supply components

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it.

Wastewater Collection. (Sewer Alternatives)

WASHOE COUNTY COMMUNITY SERVICES DEPARTMENT GRAVITY SEWER COLLECTION DESIGN STANDARDS

SECTION 2 - DESIGN STANDARDS FOR GRAVITY SANITARY SEWERS

Type of Area Density (persons/ha) Large lots 5-7 Small lots, single family 75 Small lots, two family 125 Multistory apartments min.

CITY UTILITIES DESIGN STANDARDS MANUAL

10.0 Storm Sewer Systems

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

3.9 times the average 3.8 times the average 3.6 times the average

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

Practical Hydraulics on a Large Wastewater Treatment Works

2. DEFINITIONS. American Association of State Highway and Transportation Officials.

Hancor, Inc. Drainage Handbook Hydraulics 3-1

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7: Hydraulic Design of Sewers and Storm Water Drains

The Islamic University of Gaza- Civil Engineering Department Sanitary Engineering- ECIV 4325 L5. Storm water Management

Section 7 Design Criteria Irrigation and Drainage Facilities

PART V - STORM DRAIN DESIGN CRITERIA

PART V - STORM DRAIN DESIGN CRITERIA

City of Logan Sanitary Sewer Design Standards

Asst.Prof.Dr. Jaafar S. Maatooq. 1 st Semester HYDRAULIC STRUCTUER, KINDS & FUNCTIONS 1 of 26

HY-12 User Manual. Aquaveo. Contents

PRIVATE STORM DRAINAGE FACILITIES REQUIREMENTS

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

T a b l e o f C o n t e n t s

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS

A. Introduction 7 1. Purpose 7 2. Authority 7 3. Contact 8 4. Plan Submittal Process 8 B. Design Standards General 11 a. Future Extensions 11

3.0 DESIGN CRITERIA FOR SANITARY SEWER FACILITIES

RETENTION BASIN EXAMPLE

CHAPTER 12 TRICKLING FILTER PLANTS

SECTION WASTEWATER FORCE MAINS

Introduction to Storm Sewer Design

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply:

PROCEDURE F-6-1 (formerly referenced by 08-02) Procedures to Govern Separation of Sewers and Watermains

SECTION WASTEWATER FORCE MAINS

Storm Sewers, Page 2

DRAINAGE & DESIGN OF DRAINAGE SYSTEM

DESIGN OF CHANNEL FLOW DIVERSION FACILITIES


Storm Sewer Design. Bob Pitt University of Alabama and Shirley Clark Penn State Harrisburg

RE: Final Drainage Letter: Northwest Aurora Alley Improvements 2016

CE 370. Wastewater Characteristics. Quantity. The design of a wastewater treatment plant requires knowledge of: Quantity or flowrate of wastewater.

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

Wastewater Flow Monitoring Services

City of Gardiner, Maine Wastewater Committee Meeting. CSO Storage Tank & Screening Evaluation

Minimum grade (%) Velocity at full flow (m s 1 )

FORM 1 S Design Certification List - Wastewater Agreements

CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS CUYAHOGA COUNTY ENGINEER DRAINAGE MANUAL

STORM DRAINAGE CHAPTER 11

STORM DRAINAGE CHAPTER 11

CUYAHOGA COUNTY DEPARTMENT OF PUBLIC WORKS CUYAHOGA COUNTY ENGINEER DRAINAGE MANUAL

CUYAHOGA COUNTY ENGINEER

Effluent Conveyance. Paul Trotta, P.E., Ph.D. Justin Ramsey, P.E. Chad Cooper

CITY UTILITIES DESIGN STANDARDS MANUAL

PRELIMINARY MUNICIPAL SERVICING REPORT NORTHWOODS SUBDIVISION. Prepared for: North Grassie Properties Inc.

Sump Pumps Office procedures for the Drainage & Grading section

CHECKLIST FOR STREETS, INLETS, AND STORM SEWER DESIGN

CHAPTER 4 DESIGN CRITERIA

APPENDIX F: DRAINAGE AND STORMWATER MANAGEMENT

INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GREENE COUNTY ASH POND ALABMA POWER COMPANY

Chapter 6 STEP System Force Main Velocity Evaluation

Storm Sewer Design - Introduction

Sewer Audit - Design Checklist Gravity sewers, sewage pumping stations and pressure sewers

Division 33. Utilities

DOWNTOWN SHALL NOT FLOOD AGAIN

A Stormwater Management Plan and Sediment Control Plan are required for all proposed developments within the City of Richmond.

Appendix J: Storm Conveyance Design Parameters

Module 3. Irrigation Engineering Principles. Version 2 CE IIT, Kharagpur

Air pocket removal from downward sloping pipes

Surge Analysis for the Proposed OSIS Augmentation Relief Sewer Tunnel

Hydraulic Design of Sewer

TOWN OF MANCHESTER PLANNING AND ZONING COMMISSION Subdivision Application Minimum Submission Requirements

Functional Servicing Report. Winston Park West Proposed Business Park Development Project. Infrastructure Ontario (IO) September MU1

COMPUTER APPLICATIONS HYDRAULIC ENGINEERING

Environmental and Sanitary Engineering Course

MENIFEE VALLEY CAMPUS MASTER PLAN DRAFT EIR MT. SAN JACINTO COMMUNITY COLLEGE DISTRICT. Appendices

December 6, Nate Hatleback Project Manager City of Thornton 9500 Civic Center Drive Thornton, CO 80229

Sewer Pipe Management and Maintenance. Tokyo Metropolitan Government Bureau of Sewerage, Pipeline Management Section

4A General Information A. Concept... 1 B. Conditions... 1

Chapter 10. Conduit Outlet Structures Introduction General Layout Information

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING. MSc CIVIL ENGINEERING SEMESTER TWO EXAMINATION 2017/2018 URBAN DRAINAGE SYSTEMS MODULE NO: BLT4022

Sewer Construction, Operation, and Maintenance

TABLE OF CONTENTS PART III MINIMUM DESIGN STANDARDS Section 115 WATER DISTRIBUTION SYSTEM GENERAL SIZING LINES 115.

SECTION 4 STORM DRAINAGE

Transcription:

بسم هللا الرحمن الرحيم Sag Pipe (depressed sewers, or Inverted siphons) Dr. Sataa A. Al-Bayati(10-11) A sewer that drops below the hydraulic gradient to pass under an obstruction, such as a railroad cut, subway, highway, conduit, tunnel, valley or river, is often called a sag pipe. This pipe is drop sharply, then run horizontal under the obstruction, and finally rises to the desired elevation. It may be used in drainage system. Fig.(1) Longitudinal section in a sag pipe Sag pipe acts as a trap, the velocity of sewer flow should be greater than 0.9 m/s (3 ft/s) or more for domestic wastewater, and 1.25 to 1.5 m/s (4 to 5 ft/s) for stormwater, to prevent deposition of solids (Metcalf and Eddy, Inc. 1991). Thus two or more siphons are needed with an inlet splitter box. In practice, minimum diameters for sag pipes are usually the same as for ordinary sewers: 150 or 200 mm (6 or 8 in) in sanitary sewers, and about 300 mm (12 in) in storm sewers (Metcalf and Eddy, Inc. 1991). The determination of the pipe size for sag pipes is the same as for water and wastewater mains. The size depends upon the max. wastewater flow and the hydraulic gradient. Due to high velocities in sag pipes, several pipes in parallel are commonly used. For example, it may be that a small pipe may be designed large enough to carry the min. flow; a second pipe carries the difference between the min. and average flow (or max. dryweather flow); and a third pipe carries peak flow above the average flow. Sag pipes can be constructed of ductile iron, concrete, or PVC. 1

Fig.(2) Overall Diagram Fig.(3) Plan view of inlet chamber (3 siphons) Fig.(4) Section A-A (exploded scale) 2

Design Example: Design a sag pipe system using the following given conditions: 1. Dia. of gravity sewer to be connected by sag pipe = 910 mm (36 in) 2. Slope of incoming sewer, S = 0.0016 m/m (ft/ft) 3. Min. flow velocity in sag pipe = 0.9 m/s (3 ft/s) 4. Length of sag pipe = 100 m (328 ft) 5. Max. sag pipe = 2.44 m (8 ft) 6. Design flows: Min. flow = 0.079 m 3 /s (2.8 ft 3 /s) Average flow = 0.303m 3 /s (10.7 ft 3 /s) = max. dry-weather flow Full (max.) flow = capacity of gravity sanitary sewer 7. Design three sag pipes from the inlet chamber (1) to carry min. flow (2) to carry flows from min. to average (3) to carry all flows above the average flow 8. Available fall from invert to invert = 1.0 m (3.3 ft) 9. Available head loss at inlet = 125 mm (0.5 ft) 10. Available head loss for friction in sag pipe = 1.0 m (3.3 ft) 11. Available hydraulic grade line = 1 m/100 m = 0.01 m/m 12. n = 0.015 (ductile-iron pipe) Note: The above information is required to design a sag pipe system. Solution: Step 1. Design the sag pipe (a) Calculate velocity and flow of the 910 mm sewer for full flow R = d/4 = 910 mm/4 = 227.5 mm = 0.2275 m V = (1/n)R 2/3 S 1/2 = (1/0.015) (0.2275) 2/3 (0.0016) 1/2 = 0.994 m/s Flow Q = AV = 3.14 (0.455 m) 2 (0.994 m/s) = 0.646 m 3 /s (b) Determine the size of the small sag pipe to carry the min. flow (d = dia. of the pipe) 3

Q = π (d/2) 2 (1/n) (d/4) 2/3 S 1/2 = (0.3115/n) d 8/3 S 1/2 0.079 = (0.3115/0.015) d 8/3 (0.01) 1/2 0.079 = 2.077d 8/3 [*] d 8/3 = 0.038 d = 0.293 m 300 mm = 12 in Using a 12-in (304 mm) pipe will just carry the 0.079 m 3 /s flow Check velocity V = (0.397/n) d 2/3 S 1/2 [0.397 =1/4 2/3 ] = (0.397/0.015) (0.304) 2/3 (0.01) 1/2 = 2.647 (0.304) 2/3 [**] = 1.20 m/s (verified, > 0.9 m/s) Note: A nomograph for the Manning equation can be used without calculation. (c) Determine the size of the second sag pipe for maximum dryweather flow above the minimum flow Q = (0.303-0.079) m 3 /s = 0.224 m 3 /s From [*] 0.224 = 2.077 d 8/3 d 8/3 = 0.1078 d = 0.434 m = 17.1 in A standard 18-in (460 mm) pipe would be used. Check velocity of 460mm pipe. From [**] V = 2.647 (0.460) 2/3 = 1.58 m/s > 0.9m/s ok The capacity of the 460 mm pipe would be Q = 2.077 (0.46) 8/3 = 0.262 m 3 /s 4

(d) Determine the size of the third pipe to carry the peak flow, from steps (a) & (c). the third pipe must carry = (0.646-0.079-0.262) m 3 /s = 0.305 m 3 /s The size (d) required would be d 8/3 = 0.305/2.077 d 8/3 = 0.1468 d = 0.487 m The size of 500-mm (20-in) diameter standard is chosen. The capacity and velocity of a 500-mm pipe with 0.01 hydraulic slope is Q = 2.077 (0.50) 8/3 = 0.327 m 3 /s V = 2.647 (0.50) 2/3 = 1.67 m/s > 0.9m/s ok (e) Calculate total capacity of the three pipes (300, 460, and 500 mm) Q = (0.079 + 0.262 + 0.327) m 3 /s = 0.668 m 3 /s (0.646 m 3 /s is needed) Step 2. Design the inlet and outlet chambers These sag pipes are connected from the inlet chamber & outlet chamber. Weirs (2m in length) are installed to divide the chamber into three portions. Fig. (5) Detail of sag pipe 5

Construction Notes: 1. It is recommended that the design of long sag pipes include a blowoff structure at the low point of the alignment to allow for draining of the system. These can be designed for operation by pumping or gravity draining. Shorter sag pipes can usually be easily drained by pumping from either end of the structure. 2. Sag pipes pose a significant risk to human and animal safety. Specific features must be included in the design of these structures to help alleviate these risks. 3. Air vents, pressure-release valves, or air jumper pipes may be necessary to relieve air pressure in the sag pipe, especially under less-than-capacity flows. A hydraulic jump can occur in the pipe, causing blowback and significantly reducing the capacity of the siphon. The aforementioned appurtenances allow for the release of trapped air from the pipe. Reference: - Metcalf and Eddy, Inc. 1991. 6