Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Similar documents
Table of contents. 1. Introduction

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kva. User Manual.

The power behind competitiveness. Delta UPS - Amplon Family. RT Series, Single Phase 5/ 6/ 10 kva. User Manual.

Minuteman Series. User's Manual

S70 Line Interactive Tower UPS

XPI SERIES GRID SOLAR POWER SYSTEM

Galaxy 300 and Galaxy 300i

HOBO Plug Load Logger (UX ) Manual

Operation Manual. Dual Temperature Digital Dry Block Incubator. Catalog No. INCUBATOR Rev C. April 2016

OWNER'S OPERATING MANUAL

Delta UPS - Ultron Family. HPH Series, Three Phase 60/80/100/120 kva. User Manual. The power behind competitiveness EPO

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kw. User Manual.

DJ Switch 10F V2 ORDERCODE 50365

Galaxy 300. Operation 05/

Replacing the Billboard UPS

DPS. Save This Manual

Delta UPS - Ultron Family. HPH Series, Three Phase 60/80/100/120 kva. User Manual. The power behind competitiveness EPO

! CAUTION: Read and follow these instructions.

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

Operation Manual INCUBATOR2 Dual Dry Block Incubator

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

HotSwap MBP Maintenance Bypass

Rook Currency Counter

USER MANUAL. Lion Series VA. Line Interactive UPS

APC by Schneider Electric MGE GALAXY 5500 Uninterruptible Power Supply Guide Specifications 20 kva to 120 kva Parallel UPS, three-phase

Using UPSMON-PRO Monitoring Software. Opening UPSMON-PRO Monitoring Software

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

BC Series Compact Counting Scale INSTRUCTION MANUAL

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

Instruction Manual. Model 2831D. 4 ½ Digit True RMS Digital Multimeter

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator

AHP WELDS USER MANUAL

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

Instruction Manual ODY-1765

EPS 7000 and EPS 8000

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc.

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Powerware 9120 UPS. Date: Issued By: Product Affected May 27, 2003 Gary Bankay PowerFlex 7000 MV Drive

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Cabinet. User Manual.

Ceiling Camera Lift 2015

Smart-UPS Lithium-ion Short-depth UPS 120V. APC Certainty with Total Cost of Ownership in mind

LIEBERT Nfinity UPS. GUIDE SPECIFICATIONS for a 4 to 16 KVA (208/120V or 240/120V) Single - Phase Uninterruptible Power Supply System 1.

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

TABLE OF CONTENTS INTRODUCTION SAFETY & PRECAUTIONS DRONE DIAGRAM TRANSMITTER DIAGRAM INSTALLING THE TRANSMITTER BATTERY INSTALLING THE DRONE BATTERY

Instruction Manual HT 24 BM-D2400 Homogenizer

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Smart-UPS Lithium-ion Short-depth UPS 120V. APC Certainty with Total Cost of Ownership in mind

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Liebert NXL Power-Tie Controls

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

CN Series P.N , Software rev. T 8, Revision A1- July 2014

1000 Series. User Manual Series. Uninterruptible Power Systems (UPS) Single Phase 1000 VA to 3000 VA UPS

2.4 GHz 4.5CH RC SUPERDRONE INSTRUCTION MANUAL 14+ FOR AGES 14 AND UP. 2.4GHz ITEM NO

Moving money forward UV MG

MGE TM Galaxy TM 6000: Specification guide

14+ FOR AGES 14 AND UP ITEM NO

HELIUM CADMIUM LASER INSTRUCTION MANUAL

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Intravascular Lithotripsy (IVL) Generator and Connector Cable LBL Rev E / Revision Date: March 2018

User s Manual. Chart Projector GCP-7000

Operating Manual. Wärtsilä JOVYTEC L 6kVA 10kVA. BAX 3297_en

ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER:

Installation and Operation Manual

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS IN TR O DUCT I ON S AFETY & PRE CAUTIONS D R O NE DI AGRAM TRAN SMI T T E R DIAGRAM INSTALLING THE TRANSMITTER BATTERY

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

STEAM GENERATOR STE-45-C1/3 STE-60-C1/3 STE-75-C1/3

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Please read through the usage and service instructions outlined in this owner s manual before operating the unit. Warnings Diagrams...

OPERATING INSTRUCTIONS. for the TYPE KATC-C1 AUTOMATIC TRANSFORMER COMPARATOR

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Age User s Guide. Dominator Drone

Manual Powerfirst 36V 3A

Vitobloc BACnet/IP Gateway

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

SKEYE. Mini Drone USER GUIDE

MPM 100 Monitor Product Description Guide

STN STEAM GENERATOR. Congratulations on your purchase of a SAWO Steam Generator. Please read the manual carefully before using the steam generator.

TABLE OF CONTENTS. Cordless Impact Wrench. Model No. EYFPA1J. Europe

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

PICTURE & VIDEO CAMERA 2.4GHz 4.5CH RC QUADCOPTER

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

Friendly User Interface. Simply AUTO Mode. Support the Universal input voltage

INSTRUCTION & REFERENCE MANUAL Model no. ODY-1720NX

Business Communications Manager UPS Installation and Configuration Guide

Please read these instructions before use and retain for future reference

Dual Port isolated USB Charger

HCP-7000 Opreator s Manual 1. Operator s Manual.

U51. Operations Guide

dronium TWO AP DRONE with camera

Basementsaver BP1 & BP2 Battery Backup Sump Pumps Installation

INSTRUCTION MANUAL VR HD NANO DRONE

Transcription:

Service Manual Imperial Series Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Contents of Service Manual 1. Safety Precautions ------------------------------------------------------------------ 2 1.1 Service Warnings ----------------------------------------------------------------- 2 1.2 Important Safety Instructions --------------------------------------------------- 2 2. General Information ------------------------------------------------------------------ 3 2.1 Outline ------------------------------------------------------------------------------ 3 2.2 Features ----------------------------------------------------------------------------- 3 3. SPECIFICATIONS ------------------------------------------------------------------- 5 3.1 Electrical Specifications ----------------------------------------------------------- 5 3.2 Mechanical Specifications--------------------------------------------------------- 7 3.3 Environmental Specifications ----------------------------------------------------- 7 4. Communications Interface ------------------------------------------------------- 8 5. Battery Replace Procedure ------------------------------------------------------ 10 5.1 Replacement Procedure for IMP/IMD-425~1000AP--------------------- 10 5.2 Replacement Procedure for IMP/IMD-1025~2000AP------------------- 11 6. Disassembly Procedure ----------------------------------------------------------- 12 6.1 Disassembly procedure for IMP/IMD-425~1000AP ---------------------- 12 6.2 Disassembly procedure for IMP/IMD-1025~2000AP--------------------- 13 7. Test & Adjustment Procedure ---------------------------------------------------- 14 7.1 Charger Voltage Test ------------------------------------------------------------- 14 7.2 Backup Capacity Test ------------------------------------------------------------ 14 7.3 Transfer Point Test --------------------------------------------------------------- 15 7.4 Startup On Battery --------------------------------------------------------------- 15 7.5 Communications Port Test ------------------------------------------------------- 15 8. Function Block Diagram ---------------------------------------------------------- 16 8.1 Main structure -------------------------------------------------------------------- 16 8.2 Control circuit -------------------------------------------------------------------- 16 9. Troubleshooting ----------------------------------------------------------------------- 17 1

1. Safety Precautions 1.1 Service Warnings * The UPS contains voltages what are potentially hazardous. All repairs should be performed by qualified service person. * The UPS has its own internal energy source (battery). The output receptacles may be alive even when the UPS is not connected to an AC supply. * No modification of any circuit should be attempted. Service work should only be performed after you are thoroughly familiar with all of the following safety checks and servicing guidelines. * Safe and continuous operation of the UPS depends partially on the care taken by users. Please observe the following precautions: 1.Do not attempt to power the UPS from any receptacle except a 2-pole 3-wire grounded receptacle. 2.Do not place the UPS near water or in environments of excessive humidity. 3.Do not allow liquid or any foreign objects to get inside the UPS. 4.Do not plug appliances, such as hair dryers, into the UPS receptacles. 5.Do not place the UPS under direct sunshine or close to heat-emitting sources. 6.This UPS is intended for installation in a temperature controlled, indoor area free of conductive contaminants. 1.2 Important Safety Instructions This manual contains important safety instructions. Keep this manual handy for reference. For continued protection against the risk of fire, replace with the same type / rating of fuses. While testing the UPS to determine the problem, always use a DC power supply in place of the batter. A battery can be present a risk of electrical shock, burns from high short-circuit current, fire of explosion from vented cases. Observe proper precautions. When replacing batteries, use the same number and the following type batteries: sealed lead-acid maintenance free. Proper disposal of batteries is required. Refer to your local codes for disposal requirements. There are special components used in this UPS what are important for safety. These parts are identified by the international symbol "!" on the schematic diagram and on the replacement parts list. It is essential to replace these critical parts with manufactures' specified parts to prevent shock, fire or other hazards. 2

2. General Information 2.1 Outline The Imperial Series are advanced line-interactive simulated sine wave uninterruptible power systems (UPS) designed to prevent spikes, surges, sags, transients and blackouts from reaching your sensitive equipment. Your equipment may include such items as computers and computerized instruments to telecommunication systems. When AC power is present, the UPS filters and conditions the power continuously. When AC power fails, the unit employs its internal maintenance-free battery to supply back-up power without interruption. 2.2 Features Frequency Auto Sensing The Imperial series UPS can operate in either a 50 or 60 Hz environment. When you plug the UPS into an AC outlet and turn it on, it will automatically detect the incoming line frequency and configure itself to match that frequency. Smart Buck and Boost Line Conditioning The voltage from your AC power source can fluctuate above and below the standard rating. This microprocessor controlled UPS provides line conditioning via both buck (step-down voltage) and boost (step-up voltage) functions. For example, if your normal voltage is 120V and the voltage fluctuates up to 131V, the buck function in your UPS will step it down so that your equipment receives approximately 120V. If the voltage fluctuates down to 109V, the boost function will step it up so that your equipment receives approximately 120V. This provides your equipment with excellent voltage regulation with less possibility for the UPS to drain its internal battery. User Replaceable Battery Design The battery is the most critical part in a UPS. The average lifetime of a battery is between 3 and 5 years. The special user-replaceable battery design of this 3

UPS provides significant savings and gives the UPS an almost unlimited life. You can replace the battery very easily, and without turning off your UPS or the equipment it is protecting. Advanced Interface to Communicate with Computer Many UPS s provide only a basic power failure warning. These models, together with UPSMON also provide you with important operating information. From your computer screen, you can know input/output voltage and current, frequency, battery voltage, etc., and analyze power problems. If software is not part of your UPS package, you can purchase it from your local dealer. Schedule Shutdown & Startup Using software you can locally or remotely control the shutdown and startup of equipment connected to the UPS. A customized schedule can be developed to meet your specific requirements. Data-Line Surge Protection The built-in data-line surge suppression on the rear panel completes your system protection. It provides an easy way to protect a network (RJ45) or modem (single line phone) connection from hazardous spikes. 4

3. SPECIFICATIONS 3.1 Electrical Specifications Battery output rating Product Name Frequency Rated Voltage Capacity (Hz) (V) (W) IMP/IMD-425AP 50/60 IMP/IMD-525AP 50/60 IMP/IMD-625AP 50/60 IMP/IMD-825AP 50/60 IMP/IMD-1000AP 50/60 IMP/IMD-1025AP 50/60 IMP/IMD-1200AP 50/60 IMP/IMD-1500AP 50/60 IMP/IMD-2000AP 50/60 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 100 / 110 / 115 / 120V 220 / 230 / 240V 255W 315W 375W 495W 550W 615W 720W 900W 1200W Input Voltage Range Upper Limit Buck Boost Lower Limit Rated Voltage+25% Rated Voltage+9% Rated Voltage-9% Rated Voltage-25% Input/Output Frequency Input (AC mode) Output (Inverter mode) 45Hz 55 Hz / 55 Hz 65 Hz 50 Hz / 60 Hz ± 1 Hz 5

Wave Form AC Mode Back Up Mode Sine wave Step wave Transfer time Power Failure AC Inverter 4 ms (typical) Spike/Surge protection Version Continuous Single pulse 8/20us Voltage Vrms Imax Joules 100/110/115/120V 175V 6,000A 1050max. 220/230/240V 385V 6,000A 1050max. Audible Alarm Battery discharge at power failure Battery approaches final discharge Overload UPS faulty Beep every 2 seconds Beep every half second Continuous buzzer Continuous buzzer Battery and Charger Battery type: Maintenance-free sealed-lead acid. Recharge time 6 to 8 hours typical from total discharge. (The UPS may be used immediately after discharge but will provide shorter backup time) Battery Specifications IMP/D- IMP/D- IMP/D- IMP/D- IMP/D- IMP/D- IMP/D- IMP/D- IMP/D- 425AP 525AP 625AP 825AP 1000AP 1025AP 1200AP 1500AP 2000AP DC voltage 12V 12V 12V 12V 12V 24V 24V 24V 24V Type 12V 7.2AH 12V 7.2AH 12V 7.2AH 12V 34W 12V 34W 12V 7.2AH 12V 7.2AH 12V 7.2AH 12V 34W Quantity 1 1 1 1 1 2 2 2 2 6

3.2 Mechanical Specifications: Product Name Dimensions Weight (Kg) W D H (mm) Net Shipping IMP/IMD-425AP 105*334*168 5.8 6.3 IMP/IMD-525AP 105*334*168 5.8 6.3 IMP/IMD-625AP 105*334*168 6.3 6.8 IMP/IMD-825AP 105*334*168 6.4 6.9 IMP/IMD-1000AP 105*334*168 6.5 7.0 IMP/IMD-1025AP 130*382*192 13.4 14.8 IMP/IMD-1200AP 130*382*192 13.4 14.8 IMP/IMD-1500AP 130*382*192 13.6 15.0 IMP/IMD-2000AP 130*382*192 14.5 15.9 3.3 Environmental Specifications: Operating Storage and Shipment Temperature 0 ~ 40 C (32 ~ 104 F) -20 ~ +60 C (-4 ~ +140 F) Humidity 0 ~ 95% (non-condensing) 0 ~ 95% (non-condensing) Altitude 3,000 m (10,000 ft) (Max.) 12,000 m (40,000 ft) (Max.) 7

4. Communications Interface The communication port on the rear panel of the UPS allows for connection to a host computer. When used with UPSMON communication software you will have access to important operating information. From your computer screen, you can monitor input/output voltage, AC frequency, battery voltage, etc., and analyze power problems. UPSMON will also initiate automatic graceful shutdowns during extended power failures. If UPSMON and a communication cable are not included in your UPS package purchase it from your local dealer. The following are some of the parameters you can monitor: Input Voltage Output Voltage Input Frequency Output Frequency Battery Voltage Load Percent Indicates the actual input voltage to the UPS when AC power is present Indicates the actual output voltage of the UPS Indicates the actual Input frequency of the UPS Indicates the actual output frequency of the UPS Indicates the actual output DC voltage of the UPS battery Indicates the percentage of UPS Voltage-Ampere(VA) capacity being utilized by your equipment The Imperial Series also supports software which relies on basic "contact closure signals" such as the built in UPS Service in Windows NT (you will need to purchase a special cable for this type of application). The major functions of this type of software normally include the following: * To broadcast a warning when power fails. * To close any open files before the battery rescues are exhausted. * To turn off the UPS. Note: You can connect your computer to your UPS without also connecting to the communication port. In this case, your UPS warns you of a power failure by beeping, but you have to manually shut down your UPS and computer. 8

Dsub9 Pin assignments: Pin No. RS-232 Signal Contact Closure Signal 1 2 Tx (UPS > Computer) 3 Rd (Computer > UPS) Shut Down 4 +12V (Computer > UPS) 5 GND GND 6 AC failure 7-12V (Computer > UPS) 8 Battery Low 9 Tx (Short with pin2 ) 9

5. Battery Replace Procedure Changing the batteries in your UPS is a safe and easy procedure. Since the battery is not isolated from the AC input, you must power off your UPS and unplug the power cord before proceeding the following procedure. 5.1 Replacement Procedure for IMP/IMD-425~1000AP (Optional function) 1. Remove the two screws on the battery cover. 2. Pull and open the cover as the following illustrations. Gently pull out the battery. 3. Disconnect the two wires connecting the battery to the UPS. 4. Connect the wires to the new battery, making sure that the red wire is connected to the red battery terminal and the black wire is connected to the black battery terminal. 5. Push the new battery into place. 6. Close the cover, and replace the screws back to the cover. 10

5.2 Replacement Procedure for IMP/IMD-1025~2000AP 1. Remove the screws on the battery cover. 2. Pull and open the cover. 3. Remove the screws of the battery retaining plate. 4. Pull out the battery. 5. Disconnect the two wires connecting the battery pack to the UPS 6. Connect the wires to the new battery pack, making sure that the red wire is connected to the red battery terminal and the black wire is connected to the black battery terminal. 7. Push the new battery into place. 8. Reposition the battery retaining plate and tighten the screws. 9. Slide the front panel back into place. 10. Tighten the two small screws on the bottom of the front panel. 11

6. Disassembly Procedure 6.1 Disassembly procedure for IMP/IMD-425~1000AP 6.1.1 Top Cover Removal * Turn the UPS off and unplug it from the utility line. * Remove the 6 screws on the bottom. * Open the top cover. 6.1.2 Remove the battery wire * Remove the black wire from PCB to battery. 6.1.3 Removal the PCB and Transformer * Take off all the wires on the PCB. * Remove all the screws on the PCB. * Take off the PCB. * Take off the transformer. 6.1.4 Remove the rear panel * Remove the 4 screws on the real panel. * Take off the rear panel. 12

6.2 Disassembly procedure for IMP/IMD-1025~2000AP 6.2.1 Top Cover Removal * Remove the 8 screws on the bottom and rear panel. * Take off the top cover. 6.2.2 Batter Removal * Turn the UPS off and unplug it from the utility line. * Remove the front panel and disconnect the LED wire. * Remove the battery cover. * Pull the battery out from the chassis. 6.2.3 Removal the PCB and Transformer * Take off all the wires on the PCB. * Remove the 5 screws on the PCB. * Take off the PCB. * Remove the 4 screws on the transformer. * Take off the transformer. 13

7. Test & Adjustment Procedure This Procedure outlines the steps to functionally test the IMP/IMD-425AP~2000AP models. The functional test is broken down into several sections to test each different function of the UPS. 7.1 Charger Voltage Test * Plug the UPS into an AC power source and turn the UPS on. * Disconnect positive (red) battery wire. * Using a multi-meter, verify the B+ to B- voltage is at 13.4V~14.0V(IMP/IMD-425~1000AP) or 26.8V~27.8V(IMP/IMD-1025~2000AP). If not, adjust VR1. 7.2 Over Load Test * Set the AC power source to the rating voltage. * Plug the UPS into an AC power source and turn the UPS on. * Connect a true RMS power meter to the output of the UPS. * Connect the SPS load to the output. * Add the SPS load slowly till the UPS over load alarm. * Use the following chart to verify' the power handling capabilities of the UPS. Load Product Name Overload Alarm (AC Mode) SPS IMP/IMD-425AP IMP/IMD-525AP IMP/IMD-625AP IMP/IMD-825AP IMP/IMD-1000AP IMP/IMD-1025AP IMP/IMD-1200AP IMP/IMD-1500AP IMP/IMD-2000AP 425VA~510VA 525VA~630VA 625VA~750VA 825VA~990VA 1000VA~1200VA 1025VA~1230VA 1200VA~1440VA 1500VA~1800VA 2000VA~2400VA 14

7.3 Transfer Point Test * Using a variac, set the output for the rated UPS's voltage. * Slowly reduce the variac output while monitoring the UPS's input voltage. The UPS should transfer to Boost when the voltage drops to the level given in the following Transfer Point Chart. Repeat this procedure to ensure accurate results. * While the UPS is in Boost mode. continue to slowly reduce the variac output until the UPS transfers to battery mode. The UPS should transfer to battery when the voltage drops lo the level given in the following Transfer Point Chart. * Slowly increase the variac output until the UPS goes back to on-line operation. * Continue to increase the variac output until the UPS transfers to Buck when the voltage increases to the level shown in the Transfer Point Chart. Repeat this procedure to ensure accurate results. * While the UPS is in Buck mode, continue to slowly increase the variac output until the UPS transfers to battery mode. * Check the output voltage for each step according to the Transfer Point Chart. Load 100V 110V 115V 120V 220V 240V 240V Hi to INV 122 128 134 141 140 147 146 154 268 282 281 294 293 307 INV Hi recover 118 124 130 136 135 143 142 149 260 273 271 285 283 298 Buck 106 112 117 123 122 129 127 134 233 246 244 258 254 269 Buck Recover 103 109 113 120 118 125 124 131 227 240 237 251 247 262 Boost Recover 91 97 100 107 104 112 109 116 200 213 209 223 218 233 Boost 88 94 97 103 101 108 106 113 194 207 202 216 211 226 INV Low recover 76 82 84 90 87 94 91 98 167 180 175 189 182 197 Low to INV 72 78 79 86 83 90 86 94 158 172 166-179 173 187 7.4 Startup On Battery Unplug the UPS from the variac, and press the front panel On/Off button for three seconds, and the UPS should turn on 7.5 Communications Port Test * Plug the UPS into the variac and turn on the UPS. * Connect the USB or 9 pin communication cable (721-9266-dd8) between the computer com port and UPS com port. * Start the UPSMON Monitor & Manager programs and verify the information is displayed correctly (Model, Voltage/Frequency Configuration, Input/Output etc...). * UPSMON will also initiate automatic graceful shutdowns during extended power failures. * If UPSMON and a communication cable are not included in your UPS package, you can purchase it from your local dealer. 15

8. Function Block Diagram 8.1 Main structure 8.2 Control circuit 16

9. Troubleshooting Problem Possible Cause Action to take UPS can t turn on ( LED not light) UPS can t turn on ( LED light) UPS always at battery mode Back up time too short Buzzer continuous beeping Switch on the display board fail Per Battery voltage less than 9V PCB failure Battery failure PCB failure Transformer failure AC Fuse or breaker open PCB Failure Transformer failure Battery not fully charged Battery too old PCB failure Overload Replace the display PCB Recharge the ups at least 8 hours, or change the battery. Replace the PCB Replace the battery Replace the PCB Replace the transformer Replace the AC fuse in inlet or reset the circuit breaker. Replace PCB Replace the transformer Recharge the UPS at least 8 hours Replace Battery, call for service Replace PCB Replace PCB 17