QUANLYNX APPLICATION MANAGER

Similar documents
MultiQuant Software 2.0 with the SignalFinder Algorithm

SCIEX OS Software One Touch Productivity

TurboMass GC/MS Software

UNIFI: The user environment Ken Eglinton Nordic User Training, September 2013

Waters QUATTRO PREMIER XE

Automated Purification Software for Agilent OpenLAB CDS

ICP Expert software. Technical Overview. Introduction

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

The Leading Solution for Method Validation VALIDAT

INCREASING YOUR LABORATORY PRODUCTIVITY

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

Agilent OpenLAB Chromatography Data System IT S TIME TO ACHIEVE MORE

AccuSEQ v2.1 Real-Time PCR Detection and Analysis Software

FRACTIONLYNX APPLICATION MANAGER

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Global Value 7. Productivity Suite for GammaVision. Optimizing Gamma Spectrometry Processes through Secure Data Management and Measurement Automation.

Mass Detection for the Chromatographer Waters ACQUITY QDa Detector

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

Automating HPLC and GC Analytical Method Validation Fusion AE Software Program White Paper

ProMass HR Applications!

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

Agilent InfinityLab LC/MSD Series EXTEND THE BOUNDARIES OF YOUR ANALYSIS

Chromera Speciation Software The Right Tool for the Right Answer. ICP-Mass Spectrometry. Key Benefits

MultiQuant Software Version 3.0

Automating HPLC and GC Analytical Method Validation Fusion AE Software Program White Paper

The Agilent Metabolomics Dynamic MRM Database and Method

ACCURACY THE FIRST TIME. Bring Your Esoteric Assays In-House Routinely SCIEX DIAGNOSTICS MASS SPECTROMETERS

MassHunter Profinder: Batch Processing Software for High Quality Feature Extraction of Mass Spectrometry Data

for water and beverage analysis

Streamlined and Complete LC-MS Workflow for MAM

Welcome to our E-Seminar: Automation Tools for Efficient Result Review According to GMP

The LC/MS Walk-Up Solution from Agilent

[ ANALYTICAL SERVICES SOLUTIONS ] constant DEADLINES... FASTER THAN EVER BEFORE.

Measurement & Analytics Measurement made easy. Advanced spectroscopy software for quantitative and qualitative analysis Horizon MB FTIR

SGS Delivering Excellence in Compliant Extractables and Leachables Testing

API 3200 LC/MS/MS system

HID Real-Time PCR Analysis Software v1.3

Chromeleon 7.2 CDS The Easiest Way to Boost Your IC Productivity

Purification Workflow Management

Improving Productivity with Applied Biosystems GPS Explorer

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

Thermo Scientific VetDrugs Explorer Collection

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

faster, confident more path to all the information in your samples. Agilent MassHunter Workstation Software Our measure is your success.

Fibonacci Sequences Improve GAMP 5 Risk Assessment for GLP Computerized Systems

Important Information for MCP Authors

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Introduction to Kalabie Electronic Lab Notebook. May 2009

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Gyrolab software modules

ProteinPilot Report for ProteinPilot Software

Crowe Caliber. Using Technology to Enhance AML Model Risk Management Programs and Automate Model Calibration. Audit Tax Advisory Risk Performance

Fusion Analytical Method Validation

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

METABOLOMICS. Biomarker and Omics Solutions FOR METABOLOMICS

Waters Solutions for DMPK and Biomarker Analysis. Waters User Meeting ASMS 2011 Denver, Colorado. Stephen McDonald

Multiplexing Two Different Food Residue Methods using HILIC and Reversed Phase Chromatography in the Same LC-MS/MS Run

Using Empower SystemsQT Qualification Tool

Re-defining Energy Management

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

Pharmaceutical LC/MS Solutions from Agilent Technologies

Manufacturing IT Intelligent - efficient - easy handling.

thermo scientific Find out more at thermofisher.com/lims TECHNICAL INFORMATION BULLETIN

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

Renaissance 7. Whole Body Counting Software. The Comprehensive Gamma Spectrometry Solution for Internal Contamination Monitoring Systems.

Renaissance 7. Whole Body Counting Software. The Comprehensive Gamma Spectrometry Solution for Internal Contamination Monitoring Systems.

PACER Software. Innovation with Integrity. Targeted Quantitation: Maximum Throughput, minimum effort. Software

Biacore System description. GE Healthcare. Biacore label-free interaction analysis. Optional software packages

Fusion Analytical Method Validation

UNIFI: an innovative enabling platform Ken Eglinton Nordic User Training, September 2013

Manual Analytical Data Adjustment. Environmental Health Laboratories A division of MAS Technology Corporation

IMPORTANCE OF CELL CULTURE MEDIA TO THE BIOPHARMACEUTICAL INDUSTRY

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

[ MARKET SOLUTION ] Chromatography Data System Solutions for the Agrochemical Industry

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

An Automated Processing of LC/MS Data for the Detection of Drug Impurities and Degradants in the Pharmaceutical Industry

Agilent OpenLAB Chromatography Data System COMPLIANCE AND EASE OF USE, TOGETHER AT LAST

Agilent Food Profiling Solutions ASSESS FOOD QUALITY AND POINT OF ORIGIN

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

Thermo Scientific Qtegra Intelligent Scientific Data Solution. Delivering quality. Driving productivity

Qualification of High-Performance Liquid Chromatography Systems

See More, Much More Clearly

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

SoftMax Pro 5 Software

LIMS interfaces. R.D. McDowall. The role of a LIMS MA R C H/ A P RI L

TO RESULT SOFTWARE DATA MANAGEMENT MASS SPECTROMETRY FROM SAMPLE COLLECTION MSMS WORKSTATION SOFTWARE

[ VION IMS QTOF ] BEYOND RESOLUTION

CRITICAL ASPECT ANALYTICAL TEST REVIEW

Analysis of Triazine Herbicides in Drinking Water Using LC-MS/MS and TraceFinder Software

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

CLINICAL MASS SPECTROMETRY DATA MANAGEMENT SOFTWARE FROM SAMPLE COLLECTION TO RESULT MSMS WORKSTATION SOFTWARE

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry INTRODUCTION

The future of. OpenLAB! Bernhard Etrich ChemStore Program Manager

Transcription:

QUANLYNX APPLICATION MANAGER OVERVIEW INTRODUCTION QuanLynx, an Application Manager included with Waters MassLynx Software, is designed for quantitative analysis. Simply acquiring mass spectrometry data is not enough. The ability to rapidly process LC/MS or GC/MS data to provide accurate quantitative information on sample batches is as important to today s analysts as the method and speed of acquisition. QuanLynx automates data acquisition, processing and reporting; a diagram of this workflow is shown in Figure 1. The software incorporates a wide range of interactive reviewing tools that improve productivity, confidence and security when reporting quantitative results. Method Setup The ability to accurately and rapidly reduce raw data to useful information is as important as the analytical technology employed. Waters MassLynx Software is available with a range of application-specific data processing tools to simplify raw data analysis. The QuanLynx Application Manager provides accurate quantitative results from LC/MS and GC/MS data. The program operates on groups of data files to generate quantitative results sets. Results sets may be reviewed electronically, exported to LIMS or printed. QuanLynx operates with all Waters mass spectrometers. The software is designed to simplify quantification from both routine screening and trace analysis. The application quickly generates results from acquired data sets permitting accurate quantification and review of results. Any required reprocessing is accomplished within the standalone results file. Data Acquisition Data Processing The MassLynx data security model extends to QuanLynx. The electronic QuanLynx results file includes an internal audit trail, and allows the use of electronic signatures. Results Review Reporting Figure 1. QuanLynx Application Manager workflow.

HOW QUANLYNX WORKS QuanLynx methods define the processing parameters necessary to create a results set from the samples included in a MassLynx Sample List. Quantification methods may be applied to GC/MS, LC/MS or LC/MS/MS data in any acquisition mode (e.g. full scan or selected ion recording). Data may be processed automatically when acquired or at a later time. The method editor is used to create a quantification method for all compounds assayed in a sample set. Results are then presented in a browser, which enables on-line review and re-processing of calculated results. It is a standalone file that may be viewed independently of MassLynx. CREATING A QUANLYNX METHOD The QuanLynx Method Editor (Figure 2) has a range of user-settable parameters to optimize integration, calibration, quantification, reporting and data export to other systems such as LIMS. Configurable views optimize the functionality of the editor for particular applications. The views include: All Parameters customizable to allow all parameters of interest to be viewed in a single pane Compound Properties includes compound name, retention time, quantitation trace and concentration reporting limits Calibration Properties includes calibration reference (internal standard), polynomial type and linearity threshold Integration Properties includes smoothing parameters, peak detection and thresholding Calculation Factors signal to noise measurement and detection limits Method editor parameters can be stored for each compound of interest to build up a compound library of parameters which aids creation of methods that are a subset or combination of those previously used. Figure 2. QuanLynx Method Editor showing parameter selection box.

QUANTIFYING SAMPLES When processing from the MassLynx Sample List (Figure 3) settable processing options include: Acquire data Integrate samples Calibrate standards Quantify samples Report results Export results Peak integration is accomplished with ApexTrack, an advanced peak detection algorithm. The ApexTrack algorithm automates chromatographic peak detection and baseline determination (including tailing, skew, shoulders) and avoids manual optimisation of integration for individual peaks where chromatography is not ideal. After integration, QuanLynx develops calibration curves for sample components from samples defined as standards in the sample list. A variety of polynomial curve fitting routines with or without internal standards and with or without sample weighting are available. Following calibration, samples with unknown concentrations are quantified from the fitted calibration curves and the integrated responses in the unknown samples. During results review it is possible to manually adjust integration of peaks as necessary and recalculate the results. Figure 3. MassLynx Sample List showing processing options.

REVIEWING RESULTS Processed results are presented in the QuanLynx Browser (Figure 4). The browser consists of several configurable panes to display information related to particular samples or compounds. The panes are: Sample summary table Calibration curve Residuals plot Chromatogram display Data security record (where required) The summary table presents information from the acquisition Sample List plus the related quantification results. The display can be filtered by sample, or by compound. Data reported includes: Calculated concentration (in user defined units) Peak area/height Response Internal standard area Retention time Detection flags (eg concentration out of tolerance) % Deviation Because the results file is viewed in the QuanLynx Browser, a standalone application, data can be reviewed and reprocessed without needing access to the raw data. This allows QuanLynx results to be distributed for review offline. The file contains all method parameters, which can be changed and saved locally, and results recalculated. Selecting a sample of interest displays related data in the chromatogram pane (for analytes and/or internal standards). The chromatogram and calibration panes are interactive, allowing users to manually optimize peak integration and exclude inappropriate calibration points. To speed up the peak integration review, an automated slideshow presents each sample in sample list order. The show may be paused as necessary to allow manual integration and recalculation of results. Additional results fields may be added to the table as necessary. Figure 4. QuanLynx Browser.

DATA INTEGRITY Regulations applicable to many quantitative assays require extra measures to ensure data integrity, including documented evidence of changes to results. The QuanLynx Browser documents the creation of a results file and all changes to the file in a secure audit trail. The audit trail includes the who, what, when, and why of changes. Changes are permitted based on permissions defined in the MassLynx Security Manager, supporting GxP and other regulatory requirements. Electronic signature capability is available whenever necessary. It is implemented according to local Standard Operating Procedures. REPORTING Open Access Quantification For non-expert users that require access to quantitative analysis, QuanLynx can be coupled with OpenLynx to create a walk-up system. Employing either predefined LC/MS/MS methods for known compounds, or utilising QuanOptimize for unknowns, the system allows users to submit samples via a login PC, without having to interact with MassLynx. The result is a simple interface that allows chemists to submit a sample and later receive the results as the QuanLynx Browser report via email, or as a printed report. SUMMARY Coupling QuanLynx to MassLynx Software automates data acquisition, processing and reporting of quantitative results. With the secure, independent results file, QuanLynx results are stored in their native file format. Configurable electronic and printed report formats permit output to paper and to files that may be transferred to other software applications (*.txt, *.CSV, *.XML, etc.). Direct export to LIMS is also available for immediate results transfer and distribution. PRODUCTIVITY THROUGH QUANLYNX The embedded ApexTrack algorithm significantly improves the accuracy of peak detection, saving time in data review and giving greater confidence in the results. QuanLynx provides an easy to use and flexible solution to increase laboratory productivity, including automated LC/MS(/MS) method development using QuanOptimize or walk-up quantitation with Open Access Quan. QuanOptimize Coupling QuanLynx and QuanOptimize permits fully automated method development of complete quantitative assays for LC/MS or LC/MS/MS methods. QuanOptimize automatically optimises instrument parameters for each compound required in a sample set by injecting a series of standards. The resulting method files may be used to acquire and quantify a data set. The result is an automated workflow from sample submission, to method development, data acquisition and data processing. The final output is the QuanLynx results file.

Waters, QuanLynx, QuanOptimize, OpenLynx, ApexTrack and MassLynx are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2006 Waters Corporation Produced in the U.S.A. April 2006 7200001677EN SE-PDF