SPRIworks Systems. Push button. Walk away. Fully automated library construction systems with built-in size selection and cleanup BR-15981B

Similar documents
Automated viability solutions.

BR-9516B. SNP genotyping analysis for medium to ultra-high throughput. GENOMELAB TM SNPSTREAM GENOTYPING SERIES

BIOMEK ASSAY WORKSTATION

High Throughput Illumina Nextera XT DNA Library Construction on the. Biomek FX P Dual Arm Multi-96 and Span-8 Workstation.

TAKE YOUR NEXT STEP WITH CONFIDENCE

QIAcube Pure Efficiency

Illumina TruSeq RNA Access Library Prep Kit Automated on the Biomek FX P Dual-Hybrid Liquid Handler

Fast, accurate sequencing starts here. Accelerate your NGS success with automated sample prep

HyperCap, an automatable workflow on the Agilent Bravo B

Automation of Lexogen s QuantSeq 3 mrna-seq Library Prep Kits on the Biomek FX p NGS Workstation

Biomek Automated Genomic Sample Prep Accelerates Research

QIAcube HT Your Purification Expert

Automation of the Illumina TruSeq DNA PCR-Free Sample Preparation Kit on the Biomek FX P Automated Liquid Handler

Illumina Free Adapter Blocking Reagent

Automating Genomics Applications with the Agilent Bravo Workstation

BR-10455A. Automated Multiplexed Gene Expression Profiling Process Solutions. Multiplex Quantitative High-throughput

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

Fully Automated Library Quantification for Illumina Sequencing on the NGS STAR

GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS. Genomics Solutions Portfolio

BR-10149B. Flexible solutions for confidence in results. BIOMEK FX LABORATORY AUTOMATION WORKSTATION

Fluent for Genomic Workflows INCREASED PRODUCTIVITY POWERED BY TECAN S AUTOMATION WORKSTATION

GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS. Genomics Solutions Portfolio

BR-16994A BIOMEK 4000 LABORATORY AUTOMATION WORKSTATION INTUITIVE SOFTWARE. MAXIMUM VERSATILITY.

Next Generation Sequencing Method for Illumina TruSeq DNA Sample Preparation Protocol on the Hamilton STAR

Te-Options TWO INSTRUMENTS, UNLIMITED OPTIONS, INDIVIDUAL SOLUTIONS.

Amplify Your Expectations With Bio-Rad s Full Range of PCR Solutions. Amplification: Conventional PCR

Plant genomics accelerated

Biomek Automated Genomic Sample Prep Accelerates Research

APPLICATION TECHNICAL INFORMATION

High purity plasmids. Introduction

Scaling Up NGS Sample Preparation: Automation and Lab Preparation. Alicia Burt Sr. Product Manager

PrimePCR Pricing and Bulk Discounts

PrimePCR Pricing and Bulk Discounts

PrimePCR Pricing and Bulk Discounts

NEXTFLEX 16S V4 Amplicon-Seq Kit (For Illumina Platforms) Catalog #NOVA (Kit contains 8 reactions) Bioo Scientific Corp V18.

ANALYTICAL STANDARDS AND REAGENTS

Dedicated to Molecular Diagnostics

Lab methods: Exome / Genome. Ewart de Bruijn

Overview. Tools for Protein Sample Preparation, 2-D Electrophoresis, and Imaging and Analysis

SEQUENCING FROM SAMPLE TO SEQUENCE READY

NEXTFLEX ChIP-Seq Kit (For Illumina Platforms) Catalog #NOVA (Kit contains 8 reactions) Bioo Scientific Corp V15.

solid S Y S T E M s e q u e n c i n g See the Difference Discover the Quality Genome

IH-500. Innovation Driven by Experience. Bio-Rad is one of the world s most respected suppliers of blood screening systems.

Immunohematology. IH-1000 Fully Automated System for ID-Cards

Product Catalog # Description List Price (JPY) Primer Assays (desalted)

Complete Success Begins with Sample Quality Control. Agilent 4150 and 4200 TapeStation Systems

ab High Sensitivity DNA Library Preparation Kit (For Illumina )

ab High Sensitivity DNA Library Preparation Kit (For Illumina )

Automation of the IDT xgen Lockdown Panels on the Sciclone G3 NGS Workstation

Automating FFPE Samples from Extraction to NGS Library Preparation. NGS Workflow Solution APPLICATION NOTE. Authors: Guillaume Durin Vanessa Process

Rapid, Accurate and Flexible DNA Quantitation Using the QuantiFluor dsdna System on the MANTIS Liquid Handler

Isolation of total nucleic acids from FFPE tissues using FormaPure DNA

High-Throughput Glycan Screening to Remove Biopharmaceutical Development Bottlenecks

PESTICIDE SCREENING APPLICATION SOLUTION

NEBNext Fast DNA Fragmentation & Library Prep Set for Ion Torrent

Viral nucleic acid extraction at high recovery yields

Fragment Library Preparation Using the AB Library Builder System

Automation of xgen hybridization capture on the Sciclone G3 NGS Workstation

Imaging and Electrophoresis. Gel Doc EZ Imager. Accelerate your research. Push-button imaging in just 10 seconds.

Fragment Library Preparation

NEBNext Quick Ligation Module

Evolution TM P 3 Precision Pipetting Platform

NEXTFLEX Rapid Directional RNA-Seq Kit (For Illumina Platforms) Catalog #NOVA (Kit contains 8 reactions)

Automating the C100ht Biologics Analyzer Sample Preparation on a Biomek i5 Liquid Handler Platform

Eliminating Bottlenecks with the Agilent Encore Multispan Liquid Handler

Embrace the Future of Electrophoresis

FRACTIONLYNX APPLICATION MANAGER

BIOO LIFE SCIENCE PRODUCTS

Automated library preparation using KAPA Library preparation kits on the ACSIA NGS LibPrep Edition

NovaSeq Series. Custom Primers Guide

Rotor-Gene Q quick-start guide

Cat. Nos. NT09115, NT091120, NT , NT , and NTBC0950 DISCONTINUED

Improved Chemistry for NGS Library Cleanup and Size Selection Speakers: Charles Cowles, PhD & Curtis Knox

BIOO LIFE SCIENCE PRODUCTS. NEXTflex TM 16S V4 Amplicon-Seq Kit 4 (Illumina Compatible) BIOO Scientific Corp V13.01

Illumina TruSight HLA Sequencing Panel Automated on the Biomek FX P HLA SP Liquid Handler

Plant Genomic DNA Purification... continued

Fast and reproducible amplicon library preparation for HLA typing with the 454 sequencing system

TruSight Tumor 15 Protocol Guide

ThruPLEX -FD Prep Kit Instruction Manual. Single Tube Library Preparation for Illumina NGS Platforms

BR-10149B. Flexible solutions for confidence in results. BIOMEK FX LABORATORY AUTOMATION WORKSTATION

Fluent Laboratory Automation Workstation for cell-based assays THE SIMPLE WAY TO TAKE THE COMPLEXITY OUT OF CELL BIOLOGY RESEARCH

ProteoMiner Protein Enrichment Technology

safetyiq: THE NEW DIMENSIONS OF SAFETY DISCOVER INTELLIGENT PROTECTION FOR MORE PRODUCTIVITY Forward-thinking safety products, systems and services

Solution Partner Program Global Perspective

Fully Automated C100HT Biologics Analyzer Sample Preparation on a Biomek i5 Multichannel Workstation

WORKFORCE METRICS BENCHMARK REPORT

Prepare a Barcoded Fragment Library with the SOLiD Fragment Library Barcoding Kit 1 96

KAPA Frag Kit for Enzymatic Fragmentation

QIAGEN Supplementary Protocol

Amaxa Automated Nucleofection on Tecan Freedom EVO Workstation

Automated target enrichment using SeqCapEZ DNA kits on ACSIA NGS Capture Edition

MagneSil Blood Genomic, Max Yield System INSTRUCTIONS FOR USE OF PRODUCT MD1360.

Supplementary Protocol: CIRCLE-seq Library Preparation

MassARRAY Genetic Analysis System. Genotyping Methylation Analysis Molecular Typing Somatic Mutation Profiling Quantitative Gene Expression (QGE)

Ordering Information. ProteOn XPR36 System. Protein Interaction Analysis

BioPlex 2200 System. Like no other. The first and only fully-automated, random access, multiplex testing platform. Bio-Rad Laboratories

Implementation of Automated Sample Quality Control in Whole Exome Sequencing

3 Italy Takes Its Innovation Strategy to a New Level with Collaborative Go-to-Market Plan for SMBs

Complete protocol in 110 minutes Enzymatic fragmentation without sonication One-step fragmentation/tagging to save time

BIOO LIFE SCIENCE PRODUCTS

Transcription:

SPRIworks Systems Fully automated library construction systems with built-in size selection and cleanup Push button. Walk away. BR-15981B

SPRIworks Technology Fully automated fragment library construction systems Choose the Sample Prep System That is Right for Your Lab History of Trust: Sample Prep for Genomic 2010 - Beckman Coulter utilizes SPRI chemistry for next generation sequencing sample preparation with the launch of SPRIworks Fragment Library Systems. 2005 - Recognizing the value of SPRI chemistry optimized on Biomek automated workstations, Beckman Coulter acquires Agencourt Bioscience. 2003 - As a result of the high quality sequencing data produced by Agencourt, the NHGRI designates Agencourt as one of only five Large-Scale Centers and the only commercial center responsible for genome sequencing of organisms of high biomedical importance. SPRI technology, robotics and bioinformatics enable Agencourt to be acknowledged by the sequencing community as one of the preeminent sequencing facilities. Low-Medium Throughput (Up to 30 libraries/day) SPRIworks Fragment Library Systems Fully automated library construction with built-in size selection and enzymatic cleanup Process up to 30 samples per day Bench-top system Less than 5 minutes hands-on setup time Prepares samples for Illumina*, Roche* and Life Technologies* next generation sequencers Beckman Coulter SPRIworks vs Manual Processing Methods Manual Up to 8 SPRIworks Up to 30 High Throughput (Up to 96 libraries/day) SPRIworks HT System Fully automated library construction, with built-in size selection and enzymatic cleanup Process up to 96 samples per day SPRIworks chemistry automated on Biomek robotic platforms Less than 30 minutes hands-on preparation time Prepares samples for Illumina next generation sequencers Includes optional methods for q setup normalization and pooling SPRIworks HT Up to 96 2001 - Due to SPRI s flexibility, ability to produce high quality nucleic acid, and ease of automation, Agencourt launches sequencing services and genomics products based on SPRI chemistry. (optional) Covaris E-series can be integrated on Biomek FX P 1995 - Agencourt recognizes the advantages of magnetic bead technology and acquires the license for SPRI paramagnetic beads. SPRI is immediately used as the platform for all products and services. Fully Library Construction Library construction is the number one bottleneck in the sample preparation process for next generation sequencing, requiring significant hands-on time. Additionally, multiplexing capabilities are putting strain on laboratories to prepare more libraries for sequencing than ever before. SPRIworks and SPRIworks HT Fragment Library Systems eliminate manual library construction and provide a significant boost to productivity, reproducibility and consistency. Set-up q Manual 1-8 fully sized per person Set-up q 1-30 fully sized Set-up q 1-96 fully sized (optional) T-robot on Biomek FX P with method suite By automating sample processing, laboratories can now maximize the return on their sequencing investments while freeing up valuable resources to focus on data analysis and biological interpretation. with method suite

SPRIworks Fragment Library Systems I, II and III For Illumina, Roche and Life Technologies next generation sequencers Free Your Lab From the Constraints of Next Generation Sample Prep Built-in SPRI and Cleanup Chemistry Increase library construction throughput without running gels, cutting bands for DNA fragment size selection or using columns for cleanup. The Beckman Coulter SPRIworks Fragment Library Systems improve laboratory productivity and liberate scientists to spend time focusing on data analysis. Run up to 10 samples at a time Maximize sequencing run capacity by multiplexing up to 10 samples in parallel on each system No more manual size selection gels, cleanup columns or manual fragment library construction. Fully automated library construction process Reproducible and consistent library output Only 5 minutes of hands-on time SPRI-TE Nucleic Acid Extractor Reagents predispensed in a sealed cartridge Simple library construction process No more labor intensive pipetting 200-400 size selection 300-600 size selection Short and long fragment sizes isolated using SPRIworks Fragment Library System I for Illumina GA Sequencers and analyzed using Agilent* High Sensitivity DNA Chip. Cartridge Method Card Multi-platform Library Construction Not only does the SPRIworks bench-top instrument occupy a small footprint, but it prepares fragment libraries for Illumina, Roche and Life Technologies next generation sequencers. System I for Illumina Sequencers System II for Roche Sequencers System III for Life Technologies Sequencers Throughput Up to 10 samples in about 5 hours Up to 10 samples in under 4 hours Up to 10 samples in under 4 hours SPRIworks Fragment Library Systems have three components; The SPRI-TE Nucleic Acid Extractor, a method card that controls liquid handling, and a cartridge containing all the reagents required to prepare a single library. Basic Operation Steps SPRIworks systems are simple and easy to operate. Hands-on time is significantly decreased so that technical expertise can be allocated to experiment design and data analysis. DNA input amount Size selection ranges Supported input sample types 3-5 µg 200-400 bps 300-600 bps 500 ng 350+ 500+ 1 µg (3 µg for 150-250 size selection) 150-250 bps 150-350 bps Sheared DNA, cdna, amplicons Sheared DNA, cdna, amplicons Sheared DNA, cdna, amplicons Step 1. Load cartridge into rack Step 2. Transfer input samples Step 3. Load cartridges, samples, adapters and labware Step 4. Insert method card, select size range and press START

SPRIworks HT High Throughput System For Illumina next generation sequencers Sample Prep Freedom for High Throughput Next Generation Labs Built In SPRI and Cleanup High throughput library construction without running gels, cutting bands or using columns for cleanup. Patented SPRI chemistry is combined with the flexibility of the Beckman Coulter Biomek FX P liquid handler to revolutionize how next generation sequencing samples are prepared. All chemistry needed to prepare libraries is included in a kit format along with the reagents to perform size selection and chemistry cleanup. The only thing left to do is add the DNA sample and adapter of choice. Because SPRIworks HT is automated on the Biomek automated liquid handler, users have access to a suite of methods to further streamline the next generation sequencing workflow. Such methods include: setup, (on deck with T-robot integration), cleanup, quantitation, normalization, and sample pooling. Fully automated library construction process Less than 30 minutes of hands-on time High throughput Up to 96 high quality, fully constructed and sized libraries in under 6 hours Up to 25 times the throughput of manual library construction, similar to having 25 additional people to do next generation sequencing sample preparation Simple graphical user interface Includes SPRI size selection and cleanup 150-350 size selection Short fragment sizes isolated using SPRIworks HT High Throughput System and analyzed using the Agilent High Sensitivity DNA Chip. Illumina paired end adapters were used, samples were purified with Agencourt AMPure XP and amplified with 10 cycles of. High Throughput Library Construction With an Intuitive Easy to Use Interface, Everyone is an Expert Step 1. Configure parameters using the intuitive user interface Up to 96 high quality, fully constructed and sized libraries in under 6 hours. Throughput DNA input amount Size selection options Supported input sample types SPRIworks HT Up to 96 samples in under 6 hours 1 µg 150-350 bp (insert sizes) 250-450 bp (insert sizes) 350-700 bp (insert sizes) Sheared DNA, gdna, cdna, amplicons Step 2. Method calculates reagent volumes based on user input Step 3. Place tips, plates and reagents on the instrument, click OK

Ordering Information In the United States and Canada call +1 800 361 7780 In other countries, please contact your local representative or call the country number listed below. SPRIworks Fragment Library Systems (Up to 30 libraries/day) Product # SPRIworks System I (Includes instrument, cartridges, method card and labware) A88267 SPRIworks Fragment Library kit I (For Illumina Genome Analyzer) 10 cartridges A84801 SPRIworks Fragment Library kit I (For Illumina Genome Analyzer) 50 cartridges A84803 SPRIworks System II (Includes instrument, cartridges, method card and labware) SPRIworks Fragment Library kit II (For Roche GS FLX DNA Sequencer) 10 cartridges SPRIworks Fragment Library kit II (For Roche GS FLX DNA Sequencer) 50 cartridges SPRIworks System III (Includes instrument, cartridges, method card and labware) SPRIworks Fragment Library kit III (For Life Technologies SOLiD Sequencer) 10 cartridges SPRIworks Fragment Library kit III (For Life Technologies SOLiD Sequencer) 50 cartridges A88268 A84805 A84806 A98473 A98476 A98477 SPRIworks HT System (Up to 96 libraries/day) Product # SPRIworks HT Reagent kit (For Illumina next generation sequencers) 48 samples B06938 Biomek FX P Dual Arm Multi-96 and Span-8 Workstation - SPRIworks HT 1 B05450 2 SPRIworks HT Automation Consumables (Includes Biomek tips, plates, tubes, etc. to process 960 samples) B05451 1 Contact your automation sales specialist for specific configurations. +1 800 742 2345 2 The Biomek Workstation (Product # B05450) is intended for 110V operation only. For more information, please visit www.beckmancoulter.com or contact your local sales representative. For technical support in the United States and Canada call +1 800 854 3633 (Option #, 1, 3, 3). In other countries, please contact your local representative or call the country number listed below. The process is covered by patents owned by Roche Molecular Systems, Inc., and F. Hoffman-La Roche, Ltd. * All trademarks are property of their respective owners. Beckman Coulter, the stylized logo, AMPure, Biomek, SPRI and SPRIworks are registered trademarks of Beckman Coulter, Inc. For Research Use Only. Not for use in diagnostic procedures. Australia, Gladesville (61) 2 9844 6000 Austria, Vienna (43) 1 291 01 241 Canada, Mississauga (1) 905 819 1234 China, Shanghai (86) 21 3865 1000 Croatia, Zagreb (38) 51 489 9003 Czech Republic, Prague (420) 272 01 73 32 Eastern Europe, Middle East, North Africa, South West Asia: Switzerland, Nyon (41) 22 365 3707 France, Villepinte (33) 1 49 90 90 00 Germany, Krefeld (49) 2151 33 35 Hong Kong (852) 2814 7431 India, Mumbai (91) 22 3080 5000 Italy, Cassina de Pecchi, Milan (39) 02 953921 Japan, Tokyo (81) 3 5530 8500 Korea, Seoul (82) 2 404 2146 Latin America (1) (305) 380 4709 Malaysia, Kuala Lumpur (60) 3 5621 4793 Mexico, Mexico City (001) 52 55 9183 2800 Netherlands, Woerden (31) 348 462462 Poland, Warszawa (48) 22 366 0180 Puerto Rico (787) 747 3335 Singapore (65) 6339 3633 South Africa/Sub-Saharan Africa, Johannesburg (27)11 564 3203 Spain, Madrid (34) 91 3836080 Sweden, Bromma (46) 8 564 85 900 Switzerland, Nyon (41) 0800 850 810 Taiwan, Taipei (886) 2 2730 2500 Turkey, Istanbul (90) 216 570 17 17 UK, High Wycombe (44) 01494 441181 USA, Brea, CA (1) 800 352 3433, (1) 714 993 5321 B2011-12619 www.beckmancoulter.com 2011 Beckman Coulter, Inc. PRINTED IN U.S.A.