HIGH SEAL ULF Live Loaded Packing System

Similar documents
Fisher ENVIRO-SEAL Packing System for Sliding-Stem Valves

KALREZ Packing System for Fisher Sliding Stem Valves

KALREZ Packing System for Fisher Rotary Shaft Valves

ENVIRO-SEAL Packing System for Types A11, A31A, A31D and 8532

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

Packing Selection Guidelines for Fisher Sliding-Stem Valves

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

Baumann 24000F Wafer Body Control Valve

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

Fisher Cavitrol III One, Two, and Three Stage Trims

Packing for Sliding-Stem Valves (Non-Live-Loaded)

Fisher EZ Sliding-Stem Control Valve

Baumann 16, 32, 54, and 70 Pneumatic Actuators

Fisher NotchFlo DST Control Valve

Baumannt 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

450 and 550 Series Pressure/Vacuum Relief Valve (ATEX Approved)

Fisher A11 High-Performance Butterfly Valve, NPS 30-72

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

Fisher NotchFlo DST Control Valve

Packing for Sliding-Stem Valves

133 Series Self-Operated Regulators

Run with higher performing, more versatile flow control.

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

KTM Fire-safe and Anti-Static ASME 150/300 one piece, end entry, flanged ball valve for oil, gas, petrochemical and chemical industries

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Installation Instructions, Pressure Regulator Series Manual Model: 20313, Air motor Operated: F20313, Hydraulic Motor Operated: G20313

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Specification Data CM /10. Putting You In Control Series V-Max. High Capacity V-Ported Control Ball Valve

NEOTECHA NXR PFA LINED BALL VALVES

1071 Cast Steel Globe Steam Stop Valve (Flanged)

Model 360 Control Valves

Operating Instructions

289 Series Spring-Loaded Relief Valves

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

Keystone swing type wafer check valve Figure 86

289 Series Spring-Loaded Relief Valves

Product Bulletin.1:0 February 05 Table 1. Construction Materials MATERIAL DIFFUSER FLANGE OR WHISPER DISK DIFFUSER TUBE DIFFUSER HEAD TEMPERATURE LIMI

289 Series Spring-Loaded Relief Valves

Figure 638 Series E/Series 2

PISTON BALANCED THROTTLING

1301 Series High-Pressure Regulators

SEMPELL. High Pressure Steam Bypass Valves - Type 115 ASME.

Bettis G-Series Spring-Return Pneumatic Valve Actuator Component Material List. Material List ML.GP Rev. 0 October 2017

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Welding and Solder Flange

Corrosion Protection for Fisher Valves

World Class Bellows Seal Valves

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

KTM METALTITE BALL VALVES FLOATING AND TRUNNION TYPE

High Temperature Aging Cell Instruction Manual

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

YARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

CROSBY H-SERIES DIRECT SPRING SAFETY VALVES

SEMPELL HP PREHEATER PROTECTION VALVES TYPE AVS 4/5

STP Mount Series. Installation Manual. STP-LSCR-MAN 2017 Edition v1.0. For models: STP-SCR/045 STP-SCR/060 STP-SCR/070 STP-LCR/090 STP-LCR/120

Operator s Manual for Morse Mobile-Karrier for 55-Gallon Plastic or Steel Drum

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

All definitions are defined according to ANSI/AWWA C b. Flanged Joint: The flanged and bolted joint as described in ANSI/AWWA C110/A21.10.

Worcester Controls Series 94, , and The High-Performance Solution for Fugitive Emission, Toxic Gas or High-Cycle Applications

Triple offset valve with metallic seat for High performance. Class 300: 6 to 36 (DN 150 to 900) Design in accordance with EN and ASME B16-34

Installation, Operating & Maintenance Instructions For Tri-Tech Medical Sleep Lab Panel Series

Bettis G-Series Spring-Return Pneumatic Valve Actuator Component Material List. Material List ML.GP Rev. 0 October 2017

1511 Series. Consolidated * Valves. Safety Valve

Operation Manual for Metal Sealing Butterfly Valve

Rosemount 405 Compact Primary Element

Masoneilan * Series Control Valve

Fisher. Control Valves, the Nuclear Industry Standard Proven in operating plants all over the world

MODEL 185R Kontrol-Karrier Operator s Manual for Morse Kontrol-Karrier

88L-240 Series. Low Temperature Carbon Steel ASME Class 150 Flanged Full Port Ball Valve - 1/2 through 1

Consolidated* Electromatic* Ball Valves

Installation & Maintenance Manual

Urethane Booster Pump Seal Kit (Zenith or Nordson -Type)

M21Si ISO and M21Vi ISO Reduced Bore Ball Valves DN15 to DN150 Flanged PN40

88A-200 Series. Carbon Steel ASME Class 150 Flanged Full Port Ball Valve -

Worcester Controls E51/52. Enviro-Safe High Integrity Flanged Ball Valves

1.2 REFERENCES.1 American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME)

88A-900 Series. Carbon Steel ASME Class 300 Flanged Full Port Ball Valve - 1/2 through 1 STANDARDS COMPLIANCE

ROOF MOUNT KIT OWNERS MANUAL

To Contact PS DOORS:

Installation, Operation & Maintenance Manual

Not Just Tight Shut Off Very Tight Shut Off!

CONTROL VALVE SOURCEBOOK PULP & PAPER

DESCRIPTION SAFETY: WARNINGS ORDERING INFORMATION T01-B INSTALLATION INSTRUCTIONS DROP-IN AND FREESTANDING BATH K-11343T / K-11344T

EXIRA EXPOSED PIPE SHOWER INSTALLATION

M33H ISO Full Bore Ball Valve DN50 to DN200 Flanged ASME 150 and ASME 300

ROOF MOUNT KIT OWNERS MANUAL

Edward Valves Hermavalve A Zero-Emissions Valve from Edward Valves. V-Rep 95-1

87A-200 Series. Stainless Steel ASME Class 150 Flanged Full Port Ball Valve - 1/2 through 1

Keystone Figure 412/418 Butterfly valve handles

87A-100 Series. Stainless Steel ASME Class 150 Flanged Std. Port Ball Valve -

88A-900 SERIES. Carbon Steel ASME Class 300 Flanged Full Port Ball Valve - 1/2 through 1

All definitions are defined according to ANSI/AWWA C

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Consolidated* /2/3 Series (1) Electromatic* Ball Valve System

P133 Pressure Regulator

NPS ½ - 4 DN ASME Limited Class 1700, 3100, 4500 Severe Service Metal Seated Ball Valves

Infinity - Century Combination Installation Instructions Gelcoat & Solid Surface Bathware

ALLOY BALL VALVES 7000 SERIES METAL AND SOFT SEATED 150# TO 2500#

Flowserve Anchor Darling ½ 2 Small Valve Product Line

Transcription:

Instruction Manual HIGH-SEAL Live-Loaded Packing HIGH SEAL ULF Live Loaded Packing System Contents Introduction... 1 Scope of Manual... 1 Description... 2 Spring Selection... 3 Installation... 3 Parts Ordering... 6 Retrofit Parts... 7 Parts List... 8 Figure 1. HIGH SEAL ULF Live Loaded Packing System SPRING PACKING FOLLOWER PACKING RINGS W5784 Introduction Scope of Manual This instruction manual includes installation, maintenance, and parts information for HIGH SEAL ULF live loaded packing systems (see figure 1). These systems are available for sliding stem valves with 9.5, 12.7, 19.1, 25.4, 31.8 and 50.8 mm (3/8, 1/2, 3/4, 1, 1 1/4, and 2 inch) stem diameters. Refer to separate manuals for instructions covering valves and actuators. For rotary valve applications, contact your Emerson sales office or Local Business Partner or refer to your rotary valve instruction manual. Do not install, operate, or maintain HIGH SEAL ULF live loaded packing systems without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all www.fisher.com

HIGH-SEAL Live-Loaded Packing Instruction Manual safety cautions and warnings. If you have any questions about these instructions, contact your Emerson sales office or Local Business Partner before proceeding. Description HIGH SEAL ULF live loaded packing systems combine the excellent sealing performance of the ENVIRO SEAL Graphite ULF packing set with the high performance of the HIGH SEAL spring pack. The long travel HIGH SEAL Belleville springs accurately compensate for any packing consolidation or wear, keeping the packing stress nearly constant over the life of the packing set. The HIGH SEAL load scales ensure accurate initial packing adjustment and provide positive visual indication of the packing stress at any time. It is recommended that new packing sets be adjusted to the MAX level. HIGH SEAL ULF packing systems are intended for more severe applications with pressure limits up to 290 bar (4200 psig), except for 9.5 mm (3/8 inch) stem size, which is restricted to 110 bar (1600 psig). If your application exceeds these limits, consult your Emerson sales office or Local Business Partner. For ratings on packing systems, refer to 59.1:062 Packing Selection Guidelines For Sliding Stem Valves (D101986X012). However, do not exceed the pressure/temperature limits of the valve. If the piping and valve are insulated, do not allow insulation to extend above the yoke boss surface, covering the HIGH SEAL ULF packing arrangement. Keep the HIGH SEAL ULF packing arrangement exposed to ambient air conditions. Table 1. Packing Friction with HIGH SEAL Graphite ULF Packing mm 9.5 12.7 15.9 19.1 25.4 31.8 50.8 9.5 12.7 15.9 19.1 25.4 31.8 50.8 VALVE STEM DIAMETER Inches Newtons 3/8 1/2 5/8 3/4 1 1 1/4 2 Pounds (Force) 3/8 1/2 5/8 3/4 1 1 1/4 2 HIGH SEAL GRAPHITE ULF PACKING 935 1250 1680 2350 3740 4800 6000 210 230 380 530 840 1100 1350 The flange, Belleville springs, stud bolts and nuts, packing follower, and packing arrangement are an integral part of the HIGH SEAL ULF system (see figure 6). For maximum packing life and to operate within the friction specified in table 1, do not interchange any other packing parts with the parts in the HIGH SEAL ULF system. WARNING HIGH SEAL ULF live loaded packing systems are intended for a specific range of pressure, temperature and other service conditions. The valves for which these packing systems are available are also intended for a specific range of pressure, temperature and other service conditions. Do not expose the packing system or the valve to service conditions or variables other than those for which the packing system and valve are intended. If you are not sure what these conditions are, contact your Emerson sales office or Local Business Partner. Provide the product serial number (shown on the nameplate) and all other pertinent information. Applying different conditions could result in parts damage, malfunction of the valve or loss of control of the process, and could also result in personal injury or property damage. 2

Instruction Manual HIGH-SEAL Live-Loaded Packing Spring Selection The Belleville springs for HIGH SEAL ULF systems are rated by stem size (see table 1). Available materials for the Belleville springs are S17700 (17 7 PH stainless steel) and N07718. It is important to match the appropriate load scale (see figure 2) to the stem size of the valve. Stem size is stamped on the load scale. Figure 2. Typical Load Scale STEM SIZE A4990 2 MAXIMUM SPRING LOAD MINIMUM SPRING LOAD ZERO SPRING LOAD (PACKING NUTS FINGER TIGHT) Installation HIGH SEAL ULF packing systems are designed for quality performance over extended periods. This longevity allows packing maintenance to be performed as it should be, at regularly scheduled plant outages or turn arounds. WARNING Avoid personal injury from sudden release of process pressure. Before performing any maintenance operations: Do not remove the actuator from the valve while the valve is still pressurized. Always wear protective gloves, clothing, and eyewear when performing any maintenance operations to avoid personal injury. Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the actuator cannot suddenly open or close the valve. Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure from both sides of the valve. Drain the process media from both sides of the valve. Vent the power actuator loading pressure and relieve any actuator spring precompression. Use lock out procedures to be sure that the above measures stay in effect while you work on the equipment. The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when loosening the packing box pipe plug. Check with your process or safety engineer for any additional measures that must be taken to protect against process media. 3

HIGH-SEAL Live-Loaded Packing Instruction Manual If the valve is in service, isolate the control valve from the line pressure, release pressure from both sides of the valve body, and drain the process media from both sides of the valve. If using a power actuator, also shut off all pressure lines to the power actuator and release all pressure from the actuator. Use lock out procedures to be sure that the above measures stay in effect while you work on the equipment. Refer to instructions in the appropriate valve and actuator instruction manuals. If you are installing the HIGH SEAL ULF packing system in a valve that is still connected to an actuator, it will be necessary to disconnect the valve from the actuator to provide sufficient space to install the packing assembly. Refer to appropriate valve and actuator instruction manuals. Remove old packing parts from the packing box by using the valve instruction manual procedures. Figure 3. HIGH SEAL ULF Packing Assembly Showing the Load Properly Adjusted for Decompressed Springs FLANGE BELLEVILLE SPRINGS NOT COMPRESSED INDICATOR DISK INDICATOR DISK ALIGNED WITH BOTTOM OF LOAD SCALE A4991 2 THESE TWO SURFACES MUST REMAIN PARALLEL AS YOU ALTERNATELY AND EVENLY TIGHTEN THE PACKING NUTS. The valve stem condition is critical to packing sealing performance and life. As new surface finish (0.1 μm [4 μin]r a max) is recommended for best performance. Refer to the appropriate valve instruction manual for instructions on replacing the valve stem. Check the condition of the packing bore after you have removed the packing. An easy method for cleaning debris and minor imperfections from the bore is to use a brake cylinder hone attached to an electric drill. This method will do a good job of cleaning the packing bore without changing the dimension of the bore. Inspect the packing bore size and surface finish. If the packing bore is worn, pitted, damaged, or oversized more than 0.010 inch, replace the valve bonnet or have your Emerson Automation Solutions Service Center repair it. Key number locations are shown in figure 6. 1. If a retrofit kit is being installed in place of the original packing, remove existing packing studs from the valve, and replace them with the longer studs (key 200). 2. Install the packing arrangement into the valve packing box. Note Be sure to install the packing rings in the sequence shown in figure 6. Identify parts by color or by the number stamped on the part. 4

Instruction Manual HIGH-SEAL Live-Loaded Packing For valves with 9.5 mm (3/8 inch) valve stems, do not install the packing follower (key 203) at this time. (Note: the yoke boss will not slide over the packing follower. The packing follower must be installed while lowering the actuator yoke onto the valve.) For valves with 12.5 mm (1/2 inch) or larger stem diameters, install the packing follower (key 203). 3. Refer to the appropriate valve and actuator instruction manuals when connecting the valve to the actuator. While lowering the actuator yoke onto the valve, install the packing follower [for a 9.5 mm (3/8 inch) valve stem size], indicator disk, springs, and flange (keys 203, 206, 202, and 201). Figure 4. Load Scale Indicating Minimum Spring Compression BELLEVILLE SPRINGS WITH MINIMUM COMPRESSION INDICATOR DISK INDICATOR DISK ALIGNED WITH MINIMUM COMPRESSION LINE ON LOAD SCALE A4992 2 THESE TWO SURFACES MUST REMAIN PARALLEL AS YOU ALTERNATELY AND EVENLY TIGHTEN THE PACKING NUTS. Figure 5. Load Scale Indicating Maximum Spring Compression BELLEVILLE SPRINGS WITH MAXIMUM COMPRESSION INDICATOR DISK INDICATOR DISK ALIGNED WITH MAXIMUM COMPRESSION LINE ON LOAD SCALE A4993 3 THESE TWO SURFACES MUST REMAIN PARALLEL AS YOU ALTERNATELY AND EVENLY TIGHTEN THE PACKING NUTS. 5

HIGH-SEAL Live-Loaded Packing Instruction Manual 4. Place the packing follower against the packing as shown in figure 6. 5. Place the indicator disk (key 206) and the first Belleville spring (key 202) while guiding them onto the packing follower (key 203). Make certain the cone shaped side of the Belleville spring is towards the indicator disk as shown in figure 3. 6. Place the second Belleville spring (key 202) with the coned shaped side toward the flange (key 201); see figure 3. Position the flange on top of the spring, making sure the second spring fits into its guide in the flange. CAUTION Keep the packing follower and flange centered on the valve stem. If any metal part makes contact with the stem, it can cause damage to the stem surface. Vertical scratches or nicks on the stem surface can cause excessive leakage from the packing. 7. Lubricate the packing nuts with anti seize lubricant and tighten them hand tight. 8. The load scale (figure 2) is used to indicate compression on the Belleville springs. Position the load scale (key 205) by slightly loosening the mounting screws (key 204). Align the bottom edge of the load scale with the indicator disk and retighten the screws. Figure 3 illustrates the load scale properly adjusted before the nuts have been tightened and with the Belleville springs not compressed. 9. Tighten the packing nuts while observing the two load scales (key 205) to make sure the flange (key 201) is tightened evenly. Figure 4 indicates minimum spring compression with the indicator disk aligned with the minimum compression line on the load scale. Be sure to keep the follower centered on the stem while tightening the nuts. Tighten the nuts alternately and evenly, keeping the flange parallel with the valve (see figures 4 and 5), until the indicator disk aligns with the maximum compression line on the load scales, as shown in figure 5. 10. The packing is now properly loaded and the packing nuts do not need to be retightened unless the indicator begins to approach the minimum compression line (see figure 4). After the valve has been in service for awhile, visually check the load scale to determine loading. Under normal conditions, the packing nuts should not require retightening for the life of the packing. Parts Ordering Each valve assembly is assigned a serial number that can be found on the valve. This same number also appears on the actuator nameplate when the valve is shipped from the factory as part of a control valve assembly. Refer to the serial number when contacting your Emerson sales office or Local Business Partner for technical assistance. When ordering replacement parts, refer to the serial number and to the 11 character part number for each part required from the following parts list. WARNING Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage. 6

Instruction Manual HIGH-SEAL Live-Loaded Packing Retrofit Parts Retrofit parts meet requirements to convert existing Fisher A, CAV4, E, EH, HP, YD, and YS valves to the HIGH SEAL ULF packing box construction. WARNING Stems and packing box constructions that do not meet Emerson Automation Solutions stem finish specifications, dimensional tolerances, and design specifications may adversely alter the performance of this packing retrofit, resulting in personal injury or property damage. HIGH SEAL Retrofit Kits STEM SIZE DIAMETER, YOKE BOSS DIAMETER, RETROFIT KITS mm (Inch) mm (Inch) S17700 Springs N07718 Springs 9.5 (3/8) 54 (2 1/8) RPACKXRT312 RPACKXRT322 12.7 (1/2) 71 (2 13/16) RPACKXRT332 RPACKXRT342 19.1 (3/4) 90 (3 9/16) RPACKXRT352 RPACKXRT362 25.4 (1) 127 (5) RPACKXRT372 RPACKXRT382 31.8 (1 1/4) 127 (5, 5H) RPACKXRT392 RPACKXRT402 50.8 (2) 177.8 (7) Consult your Emerson sales office or Local Business Partner (1) 1. The 50.8 mm (2 inch) stem will typically require a longer actuator yoke to clear the HIGH SEAL packing studs (key 200). Parts Included in Retrofit Kits KEY NUMBER DESCRIPTION QUANTITY For 9.5, 12.7, 19.2, 25.4, & Stems) 31.8 mm Stems For 50.8 mm Stems (3/8, 1/2, 3/4, 1, & 1 1/4 Inch (2 Inch Stems) ULF 200 Packing Stud 2 3 201 Packing Flange 1 1 202 Belleville Spring 2 2 203 Packing Follower 1 1 204 Screw 4 6 205 Load Scale 2 3 206 Indicator Disk 1 1 207 Bushing 1 1 208 Bushing 1 1 209 Packing Ring 2 2 210 Packing Ring 2 2 211 Packing Box Ring 1 1 212 Packing Nut 2 3 214 Packing Washer 3 3 219 Washer (not required on 9.5 mm [3/8 inch] stem) 2 3 7

HIGH-SEAL Live-Loaded Packing Instruction Manual Parts List Note Part numbers are shown for recommended spares only. For part numbers not shown, contact your Emerson sales office or Local Business Partner. Key Description Part Number 200 Stud 201 Flange 202 Spring See Spring Identification and Dimensions table 203 Packing Follower Key Description Part Number 204 Screw 205 Load Scale 206 Indicator Disk 207* Bushing See following table 208* Bushing See following table 209* Packing Ring See following table 210* Packing Ring See following table 211* Packing Box Ring See following table 212 Nut 213 Anti seize lubricant (not furnished with unit) (not shown) 214* Packing Washer See following table 219 Washer 8

Instruction Manual HIGH-SEAL Live-Loaded Packing Figure 6. HIGH SEAL Graphite ULF Packing Assembly 39B4153 A 1. FIND NUMBER 219 NOT REQUIRED WITH 3/8 INCH STEM 9

HIGH-SEAL Live-Loaded Packing Instruction Manual For 9.5, 12.7 and 19.1 mm (3/8, 1/2 and 3/4 Inch) Stems with ULF Packing KEY NO. QTY DESCRIPTION MATERIAL 9.5 mm (3/8 inch) Stem, 54 mm (2 1/8 inch) Yoke Boss PART NUMBER 12.7 mm (1/2 inch) Stem, 71 mm (2 13/16 Inch) Yoke Boss 19.1 mm (3/4 Inch) Stem, 90 mm (3 9/16 Inch) Yoke Boss 207* 1 Bushing Carbon 12B5780X012 12B5782X012 12B5784X012 208* 1 Bushing Carbon 19B2882X012 19B2883X012 19B2889X012 209* 2 Packing ring Carbon/graphite composite 12B5798X012 12B5799X012 12B5800X012 210* 2 Packing ring (packing ribbon) Graphite/zinc 14B7519X012 14B7498X012 14B7520X012 211* 1 Packing box ring S31600 12B5774X012 12B5775X012 12B5776X012 214* 3 Packing washer PTFE 12B6936X012 12B6937X012 12B6938X012 *Recommended spare part. Spring Identification and Dimensions SPRING Valve Stem Diameter Valve Stem Diameter Valve Stem Diameter SPRING DIMENSIONS Valve Stem Diameter Valve Stem Diameter Valve Stem Diameter mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches 9.5 3/8 12.7 1/2 19.1 3/4 25.4 1 31.8 1 1/4 50.8 2 Inside Dia 47.6 1.875 60.3 2.375 74.6 2.938 96.8 3.813 103.2 4.063 138 5.438 Outside Dia 98.4 3.875 111.1 4.375 146.1 5.75 206.4 8.125 206.4 8.125 225 8.875 Thickness 2.4 0.094 4.0 0.156 5.2 0.203 6.7 0.266 7.1 0.281 8.3 0.328 For 25.4, 38.1, and 50.8 mm (1, 1 1/4 and 2 inch) Stems with ULF Packing KEY NO. For 25.4 & 38.1 mm (1 & 1 1/4 Inch) Stems QTY For 50.8 mm (2 Inch) Stems DESCRIPTION MATERIAL 25.4 mm (1 inch) Stem, 127 mm (5 Inch) Yoke Boss PART NUMBER 31.8 mm (1 1/4 Inch) Stem, 127 mm (5 Inch) Yoke Boss 50.8 mm (2 Inch) Stem, 178 mm (7 Inch) Yoke Boss 207* 1 1 Bushing (black w/white color code) Carbon 12B5786X012 12B5788X012 12B5790X012 208* 1 1 Bushing (black) Carbon 19B2891X012 19B4141X012 19B4143X012 209* 2 2 Packing ring Carbon/graphite composite 12B5801X012 12B5802X012 12B5803X012 210* 2 2 Packing ring (packing ribbon) Graphite/zinc 14B7521X012 14B7522X012 17B3077X012 211* 1 1 Packing box ring S31600 12B5777X012 12B5778X012 12B5779X012 214* 3 3 Packing washer PTFE 12B6939X012 12B6940X012 19B4144X012 *Recommended spare part. 10

Instruction Manual HIGH-SEAL Live-Loaded Packing 11

HIGH-SEAL Live-Loaded Packing Instruction Manual Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 12 1989, 2017 Fisher Controls International LLC. All rights reserved.