Corrosion Under Insulation (CUI) and the Insulation System. By Soeren Nyborg Rasmussen ROCKWOOL Technical Insulation, Jubail, 10 December 2015

Similar documents
Corrosion and Thermal Insulation in Hot areas A New Approach

ProRox. ProRox NCS Industrial insulation PROVEN METHOD. How to combat Corrosion Under Insulation? RECOMMENDED BY EXPERTS

CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE

The Jotatemp range. The way ahead for the Jotatemp product range

Corrosion Under Insulation

Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems

Corrosion Under Insulation

JF120. offshore lightweight fire protection and insulation system. better products for challenging situations

Subject Index. STP880-EB/Aug. 1985

Corrosion Under Insulation Technologies High performance solutions

MITIGATING CORROSION UNDER INSULATION (CUI) SPREAD OF CORROSION ASSESSMENT ON ARMAFLEX INSULATION SYSTEMS IN A CONTINUOUS SALT-WATER SPRAY ENVIRONMENT

Customized test for detecting the atmospheric corrosion resistance of uncoated AISI 316 type stainless steel in marine environment

sites under the deposit become anode and the lead to pitting. Hence, a good design should not allow the built up of impurities on surface

NACE International The Worldwide Corrosion Authority by NACE International All Rights Reserved Printed in the United States of America

EDITION: INT. ENGLISH - PUBLICATION: 11/2013. It s all about. conditions... ProRox. How to prevent corrosion? Industrial insulation

Petrochemical. System Guide. Coatings, Linings, and Fireproofing

CORROSION UNDER INSULATION (CUI) A Nanotechnology Solution. Explanation:

Resimac Ltd. Engineered Polymer Solutions

Oil & Gas Midstream. System Guide. Coatings, Linings, and Fireproofing

FINAL REPORT: LARGE SCALE ACCELERATED CUI TEST OF E-2000 AND E-1100EG

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

PPG HI-TEMP PRODUCT DATA SHEET April 16, 2018 (Revision of September 5, 2017) DESCRIPTION

Resimac Limited, Unit B, Park Barn Estate, Station Road, Topcliffe, Thirsk, YO7 3SE, North Yorkshire, United Kingdom

Coating Applications - Chemical

OH&S practices as a cause of corrosion under insulation?

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

On-Line Repair Solutions for Corrosion Under Insulation

Corrosion Under Insulation

Marine. System Guide. Coatings and Linings

GIVING INDIAN POWER PLANTS 20 to 40 % LOWER INPUT ENERGY COSTS For a "one off cost" of 24,000 INR per MW of Design. Click icon to add picture

HEAT-FLEX HI-TEMP 1200 Coating Under Insulation

Northeast Gas Operation School Thursday June 5 th

Coating Types. Coating Systems. Coating Basics. Why coatings are used Component of coatings Methods of protection Service environment

OUTLINE ATMOSPHERIC CORROSION INTEGRITY MANAGMENT

Protection Effectiveness of Vapor Corrosion Inhibitor VpCI 619 for Corrosion Under Insulation at Elevated Temperatures

Agenda ISO Corrosion Protection Of steel Structures

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

PIP INEG1000 Insulation Design Guide

Title of Innovation: Pyrogel XT Water Repellent Aerogel Blanket Insulation

Protective Coatings for Steel and Concrete Bridge Components

FRAME AND SPACER MATERIALS

Don t let your money evaporate into thin air

DEVELOPMENTS IN COATINGS FOR HIGH TEMPERATURE CORROSION PROTECTION. Michael J. Mitchell. International Protective Coatings Akzo Nobel England

Prevention Strategies Design and Coatings

EDITION: EXPORT - PUBLISHED: 11/2012 NEW PRODUCT NAMES. ProRox. Product catalogue. Industrial insulation

THE HIGH COST OF UPGRADES TRANSFORMER SHORT-CIRCUITING. May Stopping Corrosion Under Insulation in Global Oil and Gas Facilities

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

HIGHLAND HITEMP. COATINGS for PEAK PERFORMANCE. HIGHLAND INTERNATIONAL

REAFFIRMATION WITH EDITORIAL REVISION October Process Industry Practices Insulation. PIP INEG1000 Insulation Design Guide

An Examination of Surface Morphology and In-Situ Study on ASTM A106-Gr.B CUI Piping in EDC Plant

NORSOK M-501 Systems Guide

JSCE-K Test methods for weathering resistance of. concrete surface coating materials

EDITION: EXPORT - PUBLISHED: 11/2013 NEW PRODUCT NAMES. ProRox. Product catalogue. Industrial insulation

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (28 C) VOC-USA / VOC Hong Kong EPA Method 24

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

Selections from ANSI/TPI National Design Standard for Metal Plate Connected Wood Truss Construction

ALLOWABLE SOLUBLE SALT CONTAMINATION LEVELS FOR INDUSTRIAL PAINTING. James A. Ellor, P.E. and Christopher L. Farschon

Termarust Technologies HRCSA Corrosion Mitigation System.

Oil & Gas Upstream. System Guide. Coatings, Linings, and Fireproofing

Phenolic Foam (PF) Insulation

Standard Practice. Control of Corrosion Under Thermal Insulation and Fireproofing Materials A Systems Approach

CUI JIP. Improved management of corrosion under insulation. Frode Wiggen & Thom Fosselie 07 June 2018 DNV GL. 07 June 2018 SAFER, SMARTER, GREENER

TNEMEC ELEVATED TEMERATURE VINYL ESTER LINING INSTALLATION GUIDE ProPolymer Series 1402, 1422 and 1432 Direct Food Contact FDA Title 21 CFR 175.

As seen in. New gel-type coatings offer corrosion protection, p.4. Stop condensation before it damages your application, p.12

How Passive Fire Protection (PFP) Works

Protective Coatings Product List 2015

Ductslab and Ductwrap

Sprayed or Blown Fibre & Ceramic Fibre (Blanket)

The flange protection challenge

PPG HI-TEMP 1000 V (AMERCOAT 873) PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

Sugar Processing and Storage Protection Systems

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Insulation Terms, Definitions & Formula

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

COATING NEW STRUCTURAL STEEL SIGN SUPPORT STRUCTURES - Item No. Special Provision No. 911S09 November 2006

Corrosion Under Insulation CUI

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

SURFACE PREPARATION FOR SYNTHETIC ROPES

PPG HI-TEMP 1000 VS. PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

Designing for Mechanical Integrity: Piping

Investigation of Chloride Ingress in Cracked Concrete Treated with Water Repellent Agents

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C

Innovative Coatings and Linings Technology for Rail Cars. Vijay Datta MS, International Paint LLC and Mike O Donoghue, PhD

Airblast Tech Tips Surface Preparation in General

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

GLASS enamelled hot water cylinder with 1 fixed spiral coil

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Zinc Silicate (Inorganic)

.4 Underwriters' Laboratories (UL)..1 UL 2218-[2010], Standard for Impact Resistance of Prepared Roof Covering Materials.

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

Pulp & Paper. System Guide. Coatings and Linings

informative Article By Dr. Santosh Gupte

ASTM Volume 04.06, November 2016 Thermal Insulation; Building and Environmental Acoustics

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Marine & Offshore Fire Divisions

Fine-Tune Your Knowledge On The Metallizing Process

One-component, heat-resistant silicone acrylic topcoat primarily for the PPG HI-TEMP 1027 primer or the PPG HI-TEMP 222 G primer

Transcription:

Corrosion Under Insulation (CUI) and the Insulation System By Soeren Nyborg Rasmussen ROCKWOOL Technical Insulation, Jubail, 10 December 2015

The issue Corrosion of steel occurs in the presence of water and oxygen So, obviously, if the steelwork under insulation remains dry there is no corrosion problem But, keeping the insulation dry can be difficult which can lead to steel work corrosion Commonly referred to as corrosion under insulation (CUI) CUI is found under all types of insulation when you have installation issues or damages Insulation does NOT protect against corrosion. Corrosion prevention requires a suitable coating, insulation, cladding and installation under dry conditions.

General corrosion process Metal + Water + Oxygen => Corrosion Accelerating factors: Time of wetness (access to water) Temperature (until the water has evaporated) Soluble salts (expecially chloride) Acidic impurities

Types of corrosion Steel is in general susceptible to CUI in the temperature range of 0 o C to 175 o C. The most frequently occuring types of CUI are: General and pitting corrosion of carbon steel, which may occur if wet insulation comes in contact with carbon steel External Stress Corrosion Cracking (ESCC) of austenitic stainless steel, which is a specific type of corrosion mainly caused by the action of water-soluble chloride from rainwater or if the insulation is not meeting the appropiate requirements General corrosion External stress corrosion cracking The corroded surface is mostly hidden by the insulation system and will not be observed until the insulation is removed for inspection or in the event of metal failure leading to incidents. Typical example corrosion under insulation

Risk of CUI Carbon/mild steel risk of corrosion Stainless steel risk of ESCC Reference: Shell DEP 30.46.00.31- Gen. September 2011

Preventing corrosion (Risk mitigation)

Critical factors Numerous factors are involved in causing or preventing corrosion under insulation Surrounding environment Indoor/outdoor Land / oceanic climate Acidic environment Operation of the plant Cyclic or continous operation Temperatures Choise and installation of coating system Design, choice and installation of the insulation system Actual operation Prompt, promptly maintenance Foot traffic Risk based inspection procedures Design? Maintenance Foot traffic

Design phase: Design pipes, vessels etc. with corrosion protection in mind: Consider: Avoidance of water traps, unintended bimetallic corrosion etc. Smooth surfaces, access for surface preparation and coating application Prevention of water ingress Ref.: ISO 12944-3

System no Choice and installation of coating system Coating system should be suitable for the operational temperatures (also when wet) Surface preparation and application is critical for performance and suppliers guidelines must be followed. Avoid damage of coating system after application. Temperature range Surface preparation (1) CS-1-45 C/50 F to 60 C/140 F ISO 8501-2: Sa 2½/ SSPC SP 10 CS-2-45 C/50 F to 150 C/300 F ISO 8501-2: Sa 2½/ SSPC SP 10 CS-3-45 C/50 F to 595 C/1100 F ISO 8501-2: Sa 3/ SSPC SP 5 CS-4 (2) -45 C/50 F to 650 C/1200 F ISO 8501-2: Sa 2½/ SSPC SP 10 Surface profile µm (mil) 50-75 (2-3) 50-75 (2-3) 50-75 (0.5-1) 40-65 (1.5 2.5) First coat µm (mil) High build epoxy 125 175 (5-7) Epoxy phenolic/ novolac 100-200 (4-8) Thermal sprayed Aluminium 250-375 (10-15) Inorganic copolymer (3) 100-150 (4-8) Finishing coat µm (mil) Blasting Coating / painting High build epoxy 125 175 (5-7) Epoxy phenolic/ novolac 100-200 (4-8) Optional: Sealer: Type acc. to service temp. 40 Inorganic Thermal spray of aluminium copolymer (3) 100-150 (4-8) Thermal sprayed aluminum

Watertight insulation protection /cladding is the first line of defence against CUI The cladding should shed water Sealing of joints Inspection points

Quality control in all phases: Steel quality, Steel work, Surface preparation, Coating application, Insulation installation, Cladding installation...

Actual operation Prompt, promptly maintenance Avoid foot traffic, and other unnecessary activities that may damage the system Risk based inspection procedures

Where is CUI a risk factor where should the inspection be more frequent? RISK = Probability X Consequence Probability of CUI is affected by: Age, condition of cladding, location (corrosivity of environment), operational temperatures, insulation material, quality/age of primary corrosion protection etc. (where does the water go?) Consequence of CUI is: Cost of shut-down for replacement, Environmental and safety hazards in case of leak etc. Probability/ Consequence High Medium Low High Medium Low

How does the insulation material affect corrosion?

Insulation selection NACE SP0198-2010 (2.1.2): CUI of carbon steel is possible under all types of insulation. The insulation type may only be a contributing factor. The insulation characteristics with the most influence on CUI are: Water-leachable salt content in insulation, such as chloride, sulphate and acidic materials that may contribute to corrosion; Water retention, permeability, and wettability of the insulation; and Foams containing residual compounds that react with water to form hydrochloric or other acids. Because CUI is a product of wet metal exposure duration, the insulation system that holds the least amount of water and dries most quickly should result in the least amount of corrosion damage to equipment. Corrosion can be reduced by careful selection of insulation materials.

Corrosion happen under all types of insulation but there are differences Go beyond the obvious (, MST, ): To minimize the risk of CUI, it is also important that the insulation does not affect the steel, does not absorb water and is open to vapour so that moisture can easily egress the insulation Essential properties and test methods Water absorption should be less than 1kg/m2 Water vapour resistance ( ) is close to 1,0 EN1609 EN12086 ph is neutral to slightly alkaline Conforms to the stainless steel corrosion specification as per ASTM test methods C692 and C871 Water leachable chloride content < 10mg/kg [AS-Quality] ASTM C795 EN13468 Mass Loss Corrosion Rate < reference test ASTM C1617

The amount of corrosion testing related to insulation products is limited Results from natural weathering testing: Massachusetts, US in 2009, 12 weeks outdoor testing. Insulation installed over bare mild steel with no cladding. Ref.: Williams, J. Evans, O., THE INFLUENCE OF INSULATION MATERIALS ON CORROSION UNDER INSULATION, NACE, Calgary Canada, February 2010.

CUI Simulation Measurements ASTM G189-07 The test apparatus is constructed such that it contains six separate test samples in one test. Test samples are carbon steel. The insulation is wetted and dried in set cycles of cold (60 ) and hot (150 C). The liquid used is recycled so that leaching products of the specific insulation influence the corrosion. Cyclic test One cycle No of cycles Duration 20 hours 4 hours 21 (21 days) Temperature 60 C 150 C Wet/dry Wet Dry

CUI Simulation Measurements ASTM G189-07 CUI Test set-up Water on the pipe Stone wool PS (ASTM C547) Aerogel (ASTM C 1728) Cellular glass (ASTM C 552)

New tools in the CUI battle

Non contact insulation Spacers ensure an air gap between the steel pipe and the insulation. Reduced time of Wetness = lower corrosion rates Hot water immersion like situations are avoided/limited = extended lifetime of the protective coating system Combining a spacer with an insulation material with a high water vapour permeability allow the water to move to the cladding where it can condense, run to a lower point and be tapped out.

Results of corrosion testing with spacers Norway 1: Results from accelerated testing in Norway, 2005: Comparing mineral wool and spacer with cellular glass directly on the pipe. Operational temperature: 105 C, with biweekly 30 minutes immersion in Seawater. Test duration 3 months. Mineral wool and spacer: Limited corrosion and coating intact. Cellular glass: Severe corrosion and coating damage.

ASTM G189-07 testing of non-contact insulation CUI simulation tests carried out by METALogic on behalf of ROCKWOOL Technical Insulation in accordance with ASTM G189-07. Comparing ASTM C547 pipe sections direct on pipe and via use of spacer rings Up to 21 cycles of 24 hours (20 hrs. 60 o C wet 4 hrs 150 o C dry) Use of demineralized water Direct to metal Non-Contact Insulation

Results of corrosion/coating testing with spacers Norway 2: Results from accelerated testing in Norway (Statoil) 2009: Comparing mineral wool with and without spacers. Operational temperature: 140 C, with 20 minutes immersion in Seawater 3 times a week. Test duration 2 months. Significant difference in coating performance even for TSA Ref.: NACE paper 10022, K. Haraldsen

Spacers what is on the market? Metal solutions available from main Insulation installers Polymer based solutions are becoming available offering added advantages. Main advantage of metal solutions is higher temperature resistance Main advantages of polymer based solutions are : No damage to heat tracing and coating No damage to coating Lower risk of injuries/damage due to sharp edges. More efficient installation

Seamless cladding Seamless cladding based on UV cured GRP is an alternative tool in the CUI fight. Eliminate/minimize water ingress Cladding with higher mechanical and chemical resistance

Wrap up CUI is a system challenge and must be addressed and planned from design phase to service. Including steps as: steelwork quality and design (smooth surfaces, water shedding) coating selection and application, insulation selection and installation, cladding selection and installation Inspection and maintenance plans in service possibly risk based Quality control important in all phases. The choice of insulation material do influence corrosion rates. Care should be given to the selection. Old assumptions may not hold-up. New tools in the CUI fight are becoming available some are available and some being finalised in the laboratories.

Thank you for your attention