Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems

Similar documents
FOAMGLAS INSULATION SPECIFICATION

PITTWRAP CW PLUS JACKETING Product Datasheet

PITTWRAP HS (HEAT SEAL) JACKETING Product Datasheet

Subject Index. STP880-EB/Aug. 1985

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

PERMATHERM PIPE INSULATION PRODUCTS

Corrosion Under Insulation

PITTWRAP B100 JACKETING Product Datasheet

Mechanical Insulation for Refrigeration Systems

PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION

PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION

PITTWRAP CF JACKETING Product Datasheet

MECHANICAL SOLUTIONS REFERENCE GUIDE FIBERGLAS FOAMGLAS THERMAFIBER FOAMULAR

TECHNICAL BULLETIN POLYISOCYANURATE VS. CELLULAR GLASS IN LOW TEMPERATURE MECHANICAL INSULATION

SECTION PLUMBING INSULATION

Corrosion Under Insulation (CUI) and the Insulation System. By Soeren Nyborg Rasmussen ROCKWOOL Technical Insulation, Jubail, 10 December 2015

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

SECTION HVAC INSULATION

Corrosion Under Insulation

MECHANICAL SOLUTIONS REFERENCE GUIDE FIBERGLAS FOAMGLAS THERMAFIBER FOAMULAR

University of Delaware

PERMATHERM, INC. SPECIFICATION FOR CHILLED WATER PIPE INSULATION

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

NIA s 62nd Annual Convention Sheraton Grand at Wild Horse Pass March 29 April 1, Barry Schmitt of Value Engineered Products

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE

Ammonia. Product performance for insulation of ammonia piping

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

B. Refer to Section : Air Distribution for lined ductwork requirements.

10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING FINISHES 2

INDUSTRIAL INSULATION. Product Selection Guide

Design & Construction Standards, Revised January

ITW INSULATION SYSTEMS

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

ITW INSULATION SYSTEMS

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

By Patrick J. Dunn, Associate Member ASHRAE, and Richard Norsworthy

1 of 17. PO Box Bellevue Rd, Newark, DE V F

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

STANDARD ENGINEERING SPECIFICATION for THERMAL INSULATION DESIGN

SECTION PIPING INSULATION

Chilled Water. Product performance for insulation of chilled water piping

Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

SECTION HVAC INSULATION

ITW INSULATION SYSTEMS

Addendum to Specifications

TRAC-LOC TANK INSULATION SYSTEM

TECHNICAL BULLETIN 0214 (update of 0111) PERFORMANCE/COST COMPARISON OF POLYISO vs. XPS PIPE INSULATION SYSTEMS

CORROSION UNDER INSULATION (CUI) A Nanotechnology Solution. Explanation:

PIP INSC1000 Cold Service Insulation Materials and Installation Specification

INSULATION PRODUCTS. Selection Guide & Reference Chart

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION

FIRE STATION 55 June 14, 2010

Corrosion and Thermal Insulation in Hot areas A New Approach

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION

SECTION HVAC PIPING INSULATION

HVAC Piping Insulation- FIBERGLAS Insulation

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

SPECIFICATION GUIDELINES FOR THE USE OF CRYOGEL Z ON COLD PIPING AND EQUIPMENT

HEAT-FLEX HI-TEMP 1200 Coating Under Insulation

Revision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

This specification describes the minimum requirements for industrial thermal insulation.

NCCER Progress Blvd, Alachua, Florida Tel: (888)

INSTALLATION GUIDELINE FOR TRYMER INSULATION

ASTM Volume 04.06, November 2016 Thermal Insulation; Building and Environmental Acoustics

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

SECTION Rev #0811 MECHANICAL INSULATION

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

PIP INSH1000 Hot Service Insulation Materials and Installation Specification

Specified to be the Best

SECTION THERMAL INSULATION GENERAL THERMAL INSULATION PART RELATED DOCUMENTS

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

HVAC INSULATION. A. General Requirements for Flexible Elastomeric Insulation: 3. Use pre-molded roll on pipe sizes 3.5" and below.

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

WEIGHT PER PIECE (LBS.)

DUKE UNIVERSITY CONSTRUCTION STANDARDS

N A N O T E C H N O L O G Y A T W O R K TM. Pyrogel Insulation TECHNICAL GUIDE

This Design guideline contained herein includes the requirements for mechanical insulation at The University of Texas at Austin

TECHNICAL BULLETIN 0414 What You Should Know About Thermal Conductivity and Aging of Low-Temperature Mechanical Insulation

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

SECTION HVAC PIPING INSULATION

SECTION MECHANICAL INSULATION

Redi-Klad 1000 Pipe Insulation

Addendum 1 Section THERMAL INSULATION FOR PIPING Burrow Avenue Pumping Station Upgrades Page 1 of 5

Match your Inspection Ports to your Process Temperatures

SECTION RIGID PAVEMENT

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

Transcription:

Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems NACE International Jubail, Kingdom of Saudi Arabia November 30, 2010 Steven T. Oslica Director of Marketing FOAMGLAS Industry Peter Bakker Regional Manager Middle East

www.foamglas.com Pittsburgh Corning Global Pittsburgh Corning Asia Pittsburgh Corning Corporation Pittsburgh Corning Europe

Our Global Reach 1940 1950 1960 1970 1980 1990 2000 2010

Advantages: Exceptional Service Worldwide and Anytime Global network of sales and engineering professionals The only cellular glass manufacturer with a truly global reach

Corrosion: Ugly and Hazardous

98% of all insulation system failures are caused by moisture intrusion.

Problems Associated With Wet Insulation Corrosion Under Insulation Affects heat gain or loss which leads to increased energy consumption Increased boil-off from low temperature tanks and risk of solidification of certain materials designed to operate at high temperatures. Damage can also result within support systems due to increases in the weight of the saturated insulation system.

CORROSION UNDER INSULATION

THE PROBLEMS WITH CORROSION UNDER INSULATION THE RATE OF CORROSION OCCURS AT A MUCH HIGHER SPEED THE CORROSION UNDER THE INSULATION CAN T BE VISUALLY DETECTED UNTIL FAILURE OCCURS

CONSEQUENCES COSTS INDUSTRY MILLIONS OF DOLLARS Replacement cost of corroded equipment Loss of productivity/production SAFETY ISSUES CUI can go undetected until leaks occur Leaks can be hazardous/fatal with combustible liquids or gases at high temperatures or pressures

FACTORS INCREASING THE POTENTIAL FOR CUI AERATED WATER MUST BE PRESENT RATE OF CORROSION DEPENDS ON THE CHEMICAL CONTENT OF WATER RATE OF CORROSION DEPENDS ON THE TEMPERATURE

Aerated Water Must Be Present The Two Primary Water Sources Involved In CUI Of Carbon Steel Are: Infiltration from external sources Condensation (internal)

Examples of External Water Sources Rainfall Drift from Cooling towers Condensation falling from cold service equipment Steam Discharge Process liquid spills Spray from fire sprinklers,deluge systems,washdowns, etc.

THE RATE OF CORROSION DEPENDS UPON THE CHEMICAL CONTENT OF THE WATER The Chemical Content of the Water Can Affect the Rate of Corrosion Two Ways: Contaminants can increase the electrical conductivity of the water thereby increasing the corrosion rate. Contaminants causing low ph solutions reduce the protection offered by product scale on carbon steel.

Low ph Contaminants Come From Two Primary Sources: External to the insulation Contaminants leached from the insulation NACE reports - Chlorides and Sulfates are the principle contaminants found under insulation. These contaminants are particular detrimental because they are highly soluble in water and these aqueous solutions have a very high electrical conductivity

Relative Corrosion Rate 140 120 100 80 60 40 20 0 Effects of ph on Corrosion Rate 3 4 5 6 7 8 PH

RATE OF CORROSION DEPENDS ON THE TEMPERATURE Carbon steel operating in the temperature range of ambient temperatures (prox.) to 300 F (149 C) is at the risk of CUI Within 32 F to 212 F (0 to 100 C) the Rate of corrosion increasing with temperature doubling every 27 F to 36 F (-2.8 C to 2 C). For carbon steel the maximum corrosion rate has been given as ambient to 250 F (121 C). For stainless steel there appears to be little or no problem of stress cracking corrosion below 120 F and above 250 F (49 to 121 C). Cyclic Temperatures will accelerate metal corrosion Lines below 25 F (-4 C) can also be subjected to CUI extended plant shutdowns. because of

RATE OF CORROSION DEPENDS ON THE TEMPERATURE Corrosion Rate (mils/yr) 40 30 20 10 0 0 25 50 75 100 125 150 175 200 225 Chemical Plant Measurements Temperature (F) NACE International

Common Approaches for Minimizing Corrosion Under Insulation Prevent Water Entry into the Insulation System Use of weather and or vapor retarders Problem - they are not long term solutions Provide a Physical Barrier These barriers are usually paints or mastics Problems - thin coatings that require good adhesion and do require periodic maintenance. Usually require controlled temperatures during application. Select an Insulation that will Minimize water intrusion Not wick or retain water Have low chloride content

The Solution : FOAMGLAS Insulation Will help to minimize water intrusion and retention since it is impermeable Will not accelerate the corrosion of carbon steel or the stress corrosion of stainless steel. ph >7 Can be used as a component of a corrosion resistant barrier Very low chloride content for use in contact with austenitic stainless steel

Definition of Thermal Conductivity The amount of heat transferred through a unit area of a material in a unit time, through a unit thickness, with a unit of temperature difference between the surface of the two opposite sides. Heat flow = Temperature difference Thickness/Conductivity K= Btu in/h ft2 F Phenolic Polyisocyanurate Fiberglas Cellular Glass Calcium Silicate Perlite Water @ 32 F ICE 0 2 4 6 8 10 12 14 16 BTU-in./hr.ft2.F

Thermal Conductivity of Insulation vs. Water Content Thermal Conductivity of Insulation Materials Under Ideal Laboratory Conditions (DRY) Thermal Conductivity of Insulation Materials with 3% Water Content by Volume Cellular Glass Mineral Wool Cellular Glass Mineral Wool 1.40 Calcium Silicate Perlite 1.40 Calcium Silicate Perlite 1.20 1.20 K:BTU in/h ft2 F 1.00 0.80 0.60 K:BTU in/h ft2 F 1.00 0.80 0.60 0.40 0.40 0.20 0.20 0.00-50 0 50 100 150 200 250 300 0.00-50 0 50 100 150 200 250 300 Mean internal temperature F Mean internal temperature F

Effects of Absorption Repellents on Water Absorption Silicone treatments are designed as water repellents on high temperature insulation materials. However these binders/repellents begin to deteriorate at temperatures as low as 175 F and are typical completely gone by 450 F. Other binders are subject to deterioration at low to moderate service temperatures over extended periods of atmospheric exposure.

Absorption & Retention of Water Cellular Glass Max Moisture By Volume 100% 80% 60% 40% 20% 0% 0.2% 35% 50% 50% 70% 65% 85% Polyiso Phenolic Perlite Fiberglass Mineral Wool Calcium Silicate Published Absorption Values %Volume Cell. Glass - 0.2% Polyiso - 2% Phenolic F. - 0.5% Perlite - 0.4% Fiberglass - 0.2% Mineral W. - Not Available Calsil - Not Available Data generated by submersion, vapor gradient, and steam exposure. Data Source- Dr. Chester P. Smolenski, V.M. Liss, PC Lab results

Water Absorption of Above Ambient Insulation

FOAMGLAS Insulation Systems Service Temperature: -450 F to 900 F (-268 C to 482 C) Multiple Bonding Techniques for high temperature ranges Hydrocal B-11 Bonded PC 136 Bonded (low chloride) Strata Fab Billets PC 400 Bore coating Check with Pittsburgh Corning Technical for the best fab adhesive for your application.

Pittsburgh Corning Accessories Title PITTCOTE 300 PITTCOTE 300FR PITTCOTE 404 PC Fabric 79 Mastics and Fabrics Properties Asphaltic Vapor Retarder 6 to 8 Gal/100ft2,.003 Perm-in Service Temp -40 to 200F (-40 to 200C) Fire Resistant Vapor Retarder 6 to 8 Gal/100ft2,.003 Perm-in Service Temp. -60 to 325F (-50 to 160C) Acrylic -Latex Weather Barrier 6 to 8 Gal/100ft2,.4 Perm-in Service Temp. -30 to 180F (-34 to 80C) 100% Polyester- 6x5.5 Mesh/inch

Pittsburgh Corning Accessories Vapor Retarder Jacketing PITTWRAP PITTWRAP SS Reinforced Polymer Modified Bituminous Heat Sealed 125 mil Service Temperature 20 to190 F (-6 to 87C).002 Perm-inch, 100 SqFt/Roll Reinforced Polymer Modified Bituminous Self Sealed 70 mil Service Temperature -25 to 170 F (-31 to 77C).002 Perm-inch, 100 SqFt/Roll PITTWRAP Reinforced Polymer Modified CW PLUS Bituminous Self Sealed 50 mil (NEW IW50) Service Temperature -25 to 100F (-31 to 37C).002 Perm-inch, 147 SqFt/Roll PITTWRAP CW30 Reinforced Polymer Modified Bituminous Self Sealed 30 mil Service Temperature -25 to 100F (-31 to 37C).002 Perm-inch, 295 SqFt/Roll

Pittsburgh Corning Accessories Title PITTSEAL 444N Joint Sealants Properties Butyl Rubber 84% Solids,.008 Perm-inch Service Temp. -70 to 180 F (-56 to 80C) NRC 1.36 chemical requirements PITTSEAL CW Sealant MS Polymer Based >90% Solids,.0015 Perm-inch Service Temp. -40 to 200F (-40 to 93C) Flame Spread/Smoke Dev. <10

Pittsburgh Corning Accessories Title PC 88 Installation Adhesives Properties Two Part Adhesive Service Temp. -70 to 180 F (-57 to 80C) Working Time 1 to 1 1/2 Hrs.005 Perm Rating PC RTV 450 High Temp. Silicone Adhesive Service Temp. -50 to 400 F Cont. (-46 to 200C) Max. Intermittent Temp. 450 F Full Cure 24 Hrs

Pittsburgh Corning Accessories Fabrication Adhesives Title Properties Competitive Products HYDROCAL Cementitious Fabrication Adhesive B-11 Service Temp. -450 to 900 F (-268 to 480C) Working Time 20 to 30 Min. Chemical but not coupon test requirements of NRC 1.36 N/A PC 136 Cementitious Fabrication Adhesive N/A Service Temp. -100 to 900 F (-73 to 480C) Working Time 20 to 30 Min Chemical and coupon requirements of NRC 1.36

Pittsburgh Corning Accessories Anti Abrasive Coatings Title Properties Competitive Products HYDROCAL Cementitious Coating N/A B-11 Service Temp. -450 to 900 F (-268 to 480C) Working Time 20 to 30 Min. Meets chemical but not coupon test requirements of NRC 1.36 PC 136 Cementitious Coating N/A Service Temp. -100 to 900 F (-73 to 480C) Working Time 20 to 30 Min Coupon and chemical requirements NRC 1.36

FOAMGLAS APPLICATIONS Temperature Range 75F to 180 F (24 C to 82 C) Insulation may be fabricated with Hydrocal B-11 or ASTM D312, Type III hot Applications: asphalt Fabrication Process control Adhesive. and PPStratafab system may be considered. V-Groove method may be used for above ambient applications. Application Requirements: Insulation may be applied in a single layer. Pipe and vessel insulation may be banded or taped in place using fiberglass reinforced tape. The wires should not be used as banding material. Mastics should only be considered for surfaces not covered with metal.

FOAMGLAS APPLICATIONS Temperature Range 181 F to 400 F (83 C to 204 C) Applications Steam, Heat Transfer, Hot Process Fabrication Requirements: Insulation must be fabricated using Hydrocal B-11 fabrication adhesive for non Stratafab systems. The use of hot asphalt bonded insulation is not recommended. The V-Groove, HTAA bore coated, or Stratafab system should be considered Application Requirements: Insulation may be installed in a single layer. Small diameter pipe insulation may be secured by either banding or tape. Tie wires not be used to secure insulation. Joint sealant is not required. Mastics should only be considered for surfaces not covered with metal.

FREE SERVICES 1. Energy Analysis Reports 2. Field Energy Surveys 3. Interactive Web site www.foamglas.com 4. Written Guidelines and Specification Writing Assistance 5. A global network of experts

www.foamglas.com/industry

THANK YOU