mint asis System Manual solar collector CERTIFICATE BBA0133

Similar documents
Clearly Solar. Installation Instructions. Solar Thermal Flat Plate Collector. Vertical On-roof mounting SHV

Clearly Solar Solar Thermal Flat Plate Collector Installation Instructions Horizontal On-roof mounting SRH 2.3

Solar Thermal Nominated Technical Persons Criteria

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION

MANUAL. portrait set-up. landscape set-up. ClickFit Evo mounting system for sloping roofs with roof tiles for solar panels

Renewable energy from the sun Daikin solar thermal systems for the installer

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

Conergy SolarFamulus II

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION

HIGH PERFORMANCE SOLAR THERMAL SOLUTIONS

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

ASSEMBLY AND MAINTENANCE MANUAL TECHNICAL SOLAR ROOF

Solar domestic hot water systems

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

Assessment Schedule - TS.5

ECOTOP VF-HF. high efficiency glazed flat-plate solar collectors > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION

Installation manual. For the competent person. Installation manual. aurotherm exclusive VTK 570/2, VTK 1140/2 GB, IE

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

HIGH-PERFORMANCE SOLAR COLLECTORS

High Quality. UniPlate. Solar Collectors ENERGY SYSTEMS. Solartechnik Prüfung Forschung

Ecotop VHT Flat plate solar collector (for forced systems)

Installation Instructions

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

On-roof system Tau Installation manual

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

TRAPEZOIDAL SHEET METAL RAIL

TEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS. Combisafe International AB

ifix INSTALLATION MANUAL PV flat roof installation system Version

INSTALLATION INSTRUCTION AEROCOMPACT S5

THE ULTIMATE SOLAR PACKAGE RENEW YOUR WAY OF THINKING

Renewable technology. For low carbon space and water heating VOKERA RENEWABLE TECHNOLOGY PRODUCTS

Tindo Karra. Installation and Specifications Manual. Introduction

SOLAR TECHNIQUE ATTACK VAKUUMTHERM VK10 PARALLEL MOUNTING BRACKETS ON THE ROOF

ST-AK 1/12. Photovoltaic Mounting Systems. Assembly Instructions. Mounting system for roofing with trapezoidal sheet metal

Camel Solar brings you some of the most advanced solar thermal systems available on the market today through innovation, research and development.

PHOTOVOLTAIC SYSTEMS. Syllabus. 1 Photovoltaic systems

RIGID SOLAR INSTALLATION MANUAL

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

Leading in integration for partial- and full roofs: Photovoltaic in-roof mounting system Solrif by Schweizer.

Solar Flat Plate Thermal Collector

Solar Thermal Explained... Barilla Solar. Presented by Karl Thorne

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Renewable energy in more detail

Installing Solar Water and Pool Heating Systems Objectives and Task Analysis for Solar Water and Pool Heating Systems Installation Contractor

SQ-1 INTELLIGENT ROOF

PE21 AMBER DOUBLE SWING OWNER S MANUAL

PE57 HOLT 2 DOUBLE SWING OWNER S MANUAL

SoliTek PV Modules INSTALLATION MANUAL

Energy Systems. Heliostar 252 S4 and 218 S4 on-roof attachment. Assembly Instructions. Living full of energy

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

OSH5063EP(PRS3607) Workplace and Work Equipment Hazard. Session 9. Working at Height

Maelstrom. Installation and Specification Guide

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

Collectors for The rough

Onduline covers the world. More than 100 countries across the globe

Electrical Services Standard Specification Cable Tray Installation. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

Operation & Service Manual

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Grant Solar Thermal Systems

INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF

Installation Instructions

USER S GUIDE for HAKITEC 750. TEMPORARY ROOF with HAKI Trak Sheeting ( Hand-Built )

Installation Overview:

DuraComp Composite Decking Installation Guide. Hidden Plastic Clip Fixing

MSE 310 on-roof/flat-roof mounting system

Instructions for the Use of the. SMB SOLAR MULTIBOARD (also referred to as SMB or board below) on Photovoltaic Arrays with Framed Modules

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Thermatile Ten-Twelve Radiant Panels. Installation instructions

Solcellspaket - Poly (4.2 kwp Jinko 265W Poly) System Plan. Created with Solar-Planit by Mikael Johansson Futura Energi AB in Simrishamn.

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS

Grant Profile. The Company. Quality design. Technology for the future. Rest assured

Equipment List and Setup Instructions

INSTRUCTION MANUAL WARNING: BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL CAREFULLY!

Beautifully Integrated Solar PV48. Cl/SfB (47) Ng2

Installation and Operation Manual

Bridge Drainage Systems

PE45 AMAZON MONKEY BARS OWNER'S MANUAL

Protective Capony RTC-16

A. This Section includes steel cable trays and accessories.

Mounting System MCG 3.0 Membrane-Connected Glass. System description

Installation Instructions Document Ref:

Mounting System MCG 3.0 Membrane-Connected Glass. System description

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate

Kaf-Tech Product Specification

Lecture 4: Solar Thermal Heat Utilization

CI/SfB Oct 12 (52.5) Uniclass L7314

Planning and installation instructions

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

CI/SfB Oct 12 (52.5) Uniclass L7314

mounting systems applications overview

Installation Instructions

Mounting systems for solar technology

Technical Description For MK-CTX Office Cabins

EASY ROOF FLAT PV FIXING SYSTEM FOR FLAT ROOF

GUIDELINES FOR SOLAR WATER HEATERS INSTALLATION

Installers Guide. Item

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Transcription:

mint asis solar collector System Manual CERTIFICATE BBA0133

mint renewables Table of contents Design and Survey... 3 General Terms and Conditions... 6 Safety Precautions... 7 System Planning... 9 System Installation... 10 Installation Schematic... 13 Hydraulic Configurations... 14 General Information... 16 Technical Data... 17 System Commissioning... 18

Design and survey report Date: Reference: Completed by: Surveyor contact no.: Client details: Name: Address: Tel.: Mobile: E-mail: 1. System type: 2. Building type (if house record whether detached, semidetached or terraced): Domestic hot water (DHW) DHW plus space heating Swimming pool heating House... Block of flats Sheltered housing Commercial (describe)... 3. Number of storeys... 4. Approximate age of building... 5. Is building listed? Yes/No 6. Is building in conservation area? Yes/No Low (circa 50%) 7. Solar fraction: Medium (circa 60%) High (circa 70%) 8. No. of occupants: 9. Approximate daily hot water usage (at 50 o c) per occupant: Low (30 litres) Medium (50 litres) High (70 litres)

Design and survey report (continued) 10. 11. 12. Type of fuel used for water heating (and approximate annual consumption in kwh) Hot water storage type Does property have combiboiler? Gas Oil LPG Electricty Solid fuel Vented Unvented Yes/No...kWh...kWh...kWh...kWh...kWh If yes, type:... Pitched roof 19. 20. 21. Available roof space Width Height up roof...m...m Any roof obstructions (e.g. Dormer, skylight, chimney stack)... Please sketch the proposed location of the solar collectors relative to the roof plan of the building 13. Proposed location for solar collectors 14. Roof orientation 15. Roof pitch 16. Flat roof Ground mounted Frame mounted on wall Type of roof covering (eg. Slate, flat tile, pan-tile etc.) 17. Roof condition 18. Any shading (eg. none, from a tree, from a structure, part of the day, a lot of the day) 22. Are there any access restrictions for erecting scaffold? (if so, draw on sketch in 21)... 23. 24. For pitched roof, collectors are to be: Space for solar cylinder(s) in airing cupboard/plant room Mounted on-roof Roof-integrated Height Width Depth...m...m...m

Design and survey report (continued) 25. 26. Proposed solar cylinder type Volume...litres Number of coils... Vented Unvented Please note and special cylinder fittings required (e.g. shower fitting, pumped secondary fittings) 26. Proposed number of Asis One collectors 27. Proposed mounting configuration Portrait/vertical Landscape/horizontal...... Additional information for swimming pools Length... 31. Pool dimensions Width... Average depth... 32. Pool location Indoors Outdoors In-ground Above ground 33. Is a pool cover used when pool is not in use? Yes/No Gas Oil 28. Proposed solar circuit type Fully filled, pressurised Drainback 34. Type of fuel used to heat the pool LPG Electricity 29. Approximate distance between proposed solar collector location and solar cylinder(s)...m Solid fuel None 30. Please note recommendations for solar circuit pipe-route and note any complications or special features 35. If pool room (where appropriate) roof has not been described in 14 to 20, please provide dimensions and notes on structure...

General Terms and Conditions Installation and commissioning should be undertaken by an MCS Certified Solar Installer Company. General terms and conditions of warranty state that all installations must completed by a MCS certified and qualified solar installer company who is currently on the live MCS register of installers. All installer companies should work to the Building Regulations in force at the time of installation.. The manufacturer s warranty will only apply if these installation instructions are followed. The warranty does not cover any damage caused by non- observance of this manual. The correct functionality of the system is only guaranteed if the installation instructions are followed. The end client should be informed at system handover that system should be checked visually once pre year and the heat exchange fluid changed once every four years. Structure The collectors may only be mounted on sufficiently loadbearing roof surfaces and substructures. The structural loadbearing capacity of the roof and the substructure must be assessed on- site, by a suitably experienced professional before mounting the collectors. Particular attention should be paid to the quality of the timber substructure in terms of the stability of the screw joints necessary for installing the collectors. In particular, it is essential to have the entire collector structure verified at the installation site by a qualified engineer in regions with high wind speeds. The assessment should also take into account any special features of the particular site that could lead to increased loads (high wind speeds, snow loads etc). mint renewables Lightning protection / Potential bonding of the building It is not necessary to connect collector arrays to the lightning protection of the building (please observe the specific electrical regulations). For installations on metal substructures at the installation site, authorised lightning protection specialists must be consulted. The metal tubes of the solar circuit must be connected to the main potential equalization bus by means of a conductor (green/yellow) with a cross- section of at least 16mm² CU (H07V- U or R). It is possible to ground the collectors to a ground rod. The grounding line must be laid outside the house. The ground rod must also be connected to the main potential equalization bus by a line with the same crosssection as above. Connections (compression connection fittings) Ladder and scaffolding assembly This document is part of the warranty and should be kept in a safe place and handed over to the end user client on completion of works. Instructions for installation and transport Mint Solar Collectors kits are delivered on pallets. Never store outside in water logged conditions. Always store on a flat surface with glass facing upwards maximum 8 collectors per stack., or vertical with glass facing outwards. The use of a carrying strap is recommended for transporting the collector. The collector must not be lifted at the connections. Avoid impacts and mechanical actions on the solar collector. Mint Solar Collectors should only be used in professionally designed systems with all system components and materials being appropriately rated for use in solar water heating systems and properly installed. Connect the collectors using the certified solar compression connections supplied with your kit. Precautions must be taken to protect the connection pipes against temperature fluctuations caused by heat expansion (expansion bends/flexible piping). In this case, no more than 6 collectors may be connected in series. Larger collector arrays must be assembled with expansion bends or flexible members inserted in the links (IMPORTANT: check the pump design). When tightening the connections, always apply counter pressure with a wrench or another spanner to prevent damage to the manifold connections. Collector inclination / General notes The collector is suitable for installation at an angle of between 15-75 Steps must be taken to ensure that water and other contaminants such as dust, etc. are prevented from getting into the collector connections and ventilation holes. Warranty Warranty claims can only be made if an appropriate specification of antifreeze is used and maintenance is carried out correctly.

Safety Precautions Before commencing mounting work on roofs, it must be ensured in all cases that the non personal fall protection and fall- arrest systems required by DIN 18338 (Roof Covering and Roof Sealing Works) and DIN 18451 (Scaffolding Works) are in place. See also Builders Protection Ordinance If non- personal fall protection or fall- arrest systems cannot be installed for technical reasons, all personnel must be secured by means of suitable safety harnesses! Only use safety harnesses (safety belts, lanyards and straps, shock absorbers, fall arresters) that were tested and certified by authorized testing bodies. If non- personal fall protection or fall- arrest systems are not provided, working without the use of suitable safety harnesses may lead to falls from heights and therefore cause serious or lethal injuries! Ladders not properly secured against sinking in, sliding or falling over may lead to dangerous falls! Whenever you are near live overhead electric cables where contact is possible, only work if: - it is ensured that they are voltage- free and this is secured for the duration of work. The live parts are secured by the ESB by covering them or cordoning them off. And are deemed safe by ESB transmission supervisor. Or advised safety distances are maintained. Voltage radius: 1m with...voltages up to 1000V 3m with...voltages from 1000V to 11000V 4m with...voltages from 11000V to 22000V 5m with...voltages from 22000V to 38000V > 5m in case of unknown voltages Safety harnesses should be fixed above the users whenever possible. Safety harnesses should only be fastened to sufficiently load bearing structures or fixing points! Never use damaged ladders (e.g., wooden ladders with split runners or rungs, or bent or buckled metal ladders). Never try to repair broken runners, rungs or steps on wooden Ladders! Ensure that ladders are put up safely. Observe the correct leaning angle (68-75 ). Prevent ladders from sliding, falling over or sinking into the ground (e.g. using wider feet, feet suited to the ground or hooking devices). Only lean ladders against secure points. Secure ladders in traffic areas by suitable Cordoning. Contact with live electric overhead cables can be lethal. Wear protective goggles when drilling and handling solar collectors evacuated tube collectors have a danger if damaged of implosion! Wear safety shoes when carrying out installation Work! Wear cut- proof safety gloves when mounting collectors and handling evacuated tube collectors (danger of implosion)! Wear a helmet The manufacturer hereby guarantees to take back products identified with an eco- label and to recycle the materials used. Only the heat transfer medium specified may be used! mint renewables

System Planning To size the system consider the use of professional design service tools Example software mint renewables

System Planning Choose the correct system configuration mint renewables

System Installation D G C H F B OR A Hot out to cylinder Cold in from cylinder F E Contents I A: Flat plate collector B: Cylindrical head clamp C: Mounting rail D: Mounting bracket (Screws optional) E: Compression 22mm Straight connector F: Compression 22mm Elbow G: Compression 22mm Stop end H: Auto air vent kit (Optional) I: Anti slip bracket mint renewables

System Installation Work out the position for all fixing brackets and mounting rails referring to the fixing distances provided See distances shown on pages 12 Fix mounting brackets and rails See distances shown on page 13

Work out the position for all fixing brackets and mounting rails referring to the fixing distances provided Number of collectors Minimum number of fixing points per rail A B 1 2 3 4 5 6 2 2 4 4 6 7 1,250mm to 1,550mm Max. 453mm C 1,225mm 2,453mm 3,678mm 4,906mm 6,131mm 7,359mm D1 Max. 800mm Max. 1,600mm Max. 1,600mm Max. 1,600mm Max. 1,600mm Max. 1,600mm B B D2 - - Max. 800mm Max. 800mm Max. 800mm Max. 800mm D3 - - Max. 800mm Max. 1,600mm Max. 1,600mm Max. 800mm D4 - - - - Max. 800mm Max. 1,600mm D5 - - - - Max. 800mm Max. 800mm D6 - - - - - Max. 1,600mm D C D Number of collectors Minimum number of fixing points per rail 1 2 3 4 5 6 2 3 4 7 8 10 B B A 800mm to 1,100mm B Max. 370mm C 1,785mm 3,570mm 5,355mm 7,140mm 8,925mm 10,710mm D1 Max. 1,600mm Max. 1,600mm Max. 1,600mm Max. 800mm Max. 800mm Max. 1,600mm D2 - Max. 1,600mm Max. 1,600mm Max. 800mm Max. 800mm Max. 1,600mm D3 - - Max. 1,600mm Max. 1,600mm Max. 1,600mm Max. 800mm D4 - - - Max. 1,600mm Max. 1,600mm Max. 800mm D5 - - - Max. 800mm Max. 1,600mm Max. 800mm D6 - - - Max. 800mm Max. 800mm Max. 800mm D D D7 - - - - Max. 800mm Max. 800mm D8 - - - - - Max. 1,600mm C D9 - - - - - Max. 1,600mm

System Installation 1 1a 3 3a 3b 3c 3a Optional anti slip support 3c 3c 3b 2 2a 4 4a 2a 4a 2a 2a

System Installation Schematic A Solar collector B Solar metal flex pipe C ¾ Self sealing nipple D Pumpstation E Discharge container hose F Discharge container G Expansion vessel hose H Expansion vessel one way valve I Expansion vessel J Expansion vessel bracket K 22mm Stub L Drain off valve M Solar cylinder A B L - Live power in R1 - Relay (live out to pump) N - Naturals ( power in & pump) 1 - Positive temperature sensor from collector (red) 2 - Positive temperature sensor from bottom cylinder sensor pocket (red) C M K D L J G I H E F mint renewables Support 01302 325000

Hydraulic Configuration Key: Flow direction End cap Flow End cap and air vent Return Stop-valve Expansion pipe Corrugated pipe connector Collector connection The following drawings show potential connection solutions. Given the structural conditions, however, the situation can be different in practice. If a collector array comprises more than 6 collectors, the relevant provisions for compensating the heat expansion caused by temperature fluctuations must be included (expansion bends and flexible pipework) or the array will be started up repeatedly in parallel. mint renewables

Hydraulic Configurations The diagrams offer a guide to flow methods. Mass flow rate To ensure the performance of the collector, a specific flow rate of 30 l/m²h is to be selected up to a collector panel size of approx.25m².

General Information Installing the temperature sensor The solar collector temperature sensor should be installed in the sensor sleeve nearest to the collector array flow. To ensure optimal contact between the temperature sensor and the surrounding environment, the gap between the sensor sleeve and the sensor element should be filled with a suitable conducting compound. All materials used for installing temperature sensors (sensor element, conducting compound, cables, sealing and insulating materials ) must be suitably temperature resistant (up to 250 o c). Operating pressure The maximum operating pressure is 10 bar. Removal of air from the system (bleeding) The system should be properly bled at commissioning to remove as much air as possible from the system. We would recommend that after 2 to 4 weeks of operation the system is bled again. Warning! - When bleeding the system there is a risk of scalding due to steam and hot transfer fluid and appropriate care must be taken. Only operate the bleeding valve if the temperature of the heat transfer fluid is below 60 o c. When bleeding the system the collectors must not be hot! Cover the collectors and, if possible, bleed the system in the morning. Checking heat transfer fluid The heat transfer fluid must be checked at least every four years with regard to its antifreeze content and ph value. Check the antifreeze with an antifreeze tester and replace or refill if necessary. We would recommend a target protection of -25 o c. Check the ph value with a ph indicator rod. If the limit ph value is less than 7.0 then replace the heat transfer fluid. Collector maintenance The solar collectors should be inspected visually, once a year, for any signs of damage, leaks or contamination.

mint asis solar collector Asis One collector technology On roof In roof Flat roof CERTIFICATE BBA0133 One collector with three methods of fitting - on roof, roof integrated or frame mounted. This provides a truly versatile collector offering a high quality, high performing solution to any system specification. Connections 4 x 22mm Black-Frame Solar Glass 32mm High Selective Coated Absorber Risers 8mm The Asis One solar collector features a high-efficiency selective coated aluminium absorber plate housed beneath black framed, low iron, high transmission glass. This combination of specially selected materials offers an attractive appearance with optimal performance, producing high energy yields. Flange Plate Temperature Sensor Pocket Aluminium Profile Insulation 40mm Aluminium Back Sheet Best in class performance Versatile mounting options: - up to 8 collectors in a row Asis One collector performance As well as it`s great versatility, the Asis One series of collectors has a top of class performance efficiency. - On-roof - Flat roof - In-roof Vertical and Horizontal mounting Intelligent mounting concept Maximum precision manufacture: - Robot controlled production Asis One technical data Zero loss collector efficiency 81.4% Heat loss coefficient 4.061 Overall area 2.02m 2 Aperture area 1.84m 2 Solar Keymark and MCS Certificate: - 10 years warranty & - 30+ year life expectancy Manufactured in Austria Length x width Weight Max. operating pressure 1730mm x 1130mm 35kg 10 bar

Technical data Collector type Zero loss collector efficiency Collector type Asis One 1A Frame collector 81.4% Overall area [m²] 2.02 Absorber area [m²] 1.84 Aperture area [m²] 1.84 L x W x H [mm] 1730,1170,83 Weight [kg] 35 Maximum operating pressure 10 bar Absorber capacity [L] 1.65 Housing Back plate Absorber sheet Bespoke extruded aluminium frame Aluminium sheet Laser welded aluminium, highly selective mirotherm coating Absorption [%] 95 Emission [%] 5 Ø manifold [mm] 22 Ø risers [mm] 8 Connections Glass Transmittance of glass [%] Insulation Max. Stagnation temperature Proper heat transfer medium Approved installation angle 4 x blank (compression joint) 3.2mm tempered solar safety glass - black frame design 90 40mm mineral wool plate 192ºc under norm conditions Polypropylene glycol / water based Min 15º, max 75º Asis One collector technology The Asis One solar collector features a high-efficiency selective coated aluminium absorber plate housed beneath black framed, low iron, high transmission glass. This combination of specially selected materials offers an attractive appearance, optimal use of the area and produces high energy yields. Due to its construction of 3.2mm low iron glass and specially designed aluminium extrusion, the modules are light in weight in addition to protecting the internal components against harsh environmental conditions. Precision manufacturing on a robot controlled assembly line guarantees high mechanical strength, making the module resistant to extreme wind, hail and snow. Efficiency Curve Efficiency absorber = Efficiency aperture Asis One 1A

System commissioning checklist: Customer details: Name: Commissioning date: Solar collector serial numbers Address: Telephone number: Mobile number: E-mail address: Installer details: Company name: Address: Telephone number: Mobile number: E-mail address: Web-site: MCS number: System summary: Number of Asis One 1A collectors Type and volume of cylinder Type of pump-station and controller Type of solar circuit fitted Solar collector mounting brackets and clips inspected and secure Solar collector connections inspected and properly fitted and tightened Type of weatherproofing of roof penetrations (for inlet and outlet pipe-work and sensor cable)... Penetration weatherproofing inspected and properly fitted Collector sensor probe securely fitted into collector sensor pocket Primary pressure limit of weakest component...bar System pressure when cold...bar Fuse rating for fused-spur supply to controller and pump... Controls and sensors checked and operating correctly Maximum cylinder temperature setting in controller Cylinder temperature sensors secured and sensor cable tied neatly Expansion vessel capacity Expansion vessel pre-charge pressure... 0 c... 0 c... 0 c...litres...bar

System commissioning checklist (continued: Declaration (to be completed by the commissioning engineer): Volume of drain-back vessel (if drainback circuit): used) System flow-rate Primary circuit volume Type of heat transfer fluid used Earth bonding present...litres...litres/min...litres... I confirm that the system described in this commissioning checklist has been installed at the address stated. The system design is in line with best practice and the system has been installed to comply with the Microgeneration Certification Scheme Standard MIS3001 and with all legal requirements. All notifiable works have been carried out by suitably qualified personnel and have been notified to the relevant authorities. Direction of non-return valve checked Signed: Print name: Position and type of air-vents used Air-vent(s) isolated after commissioning Type and thickness of insulation used Pipe-work all insulated (apart from tee off to expansion vessel and air-vent) Pump operation and checked and pump running quietly Pump speed setting Method of anti-scalding in DHW circulation Location of fused isolation switch Location of pressure gauge System explained to customer System documentation provided to customer... Yes/No............... Date of commissioning: CERTIFICATE BBA 0133 mint renewables

A reliable hand for expert advice and support Mint Renewables Limited Kelham Court Kelham Street Industrial Estate Doncaster DN1 3RF Phone: 01302 325000 Technical support: 01302 364416 Email: info@mintrenewables.co.uk