Jim Bridger Plant Document Type: PLANT POLICIES & PROCEDURES Document ID Number: ENV-CCR001

Plant Bowen - Operations Procedures Fugitive Dust Control Plan AMENDMENT SUMMARY. Date Amendment # Comments I Notes. Page 2 of 5

Plant Yates - Operations Procedures Fugitive Dust Control Plan AMENDMENT SUMMARY. Date Amendment # Comments I Notes. Page 2 of 5

CCR Fugitive Dust Control Plan

2016 Fugitive Dust Control Report Coal Combustion Residuals Rule. Escalante Generating Station Prewitt, New Mexico

FUGITIVE DUST CONTROL PLAN FUGITIVE DUST CONTROL

FUGITIVE DUST CONTROL PLAN

PUBLIC SERVICE COMPANY OF OKLAHOMA (PSO)

CCR COMPLIANCE FUGITIVE DUST CONTROL PLAN. Prepared for: GenOn Northeast Management Company Conemaugh Generating Station New Florence, Pennsylvania

Talen Energy Colstrip Steam Electric Station (CSES) Coal Combustion Residuals (CCR) Fugitive Dust Control Plan (FDCP) October 19, 2015

CCR COMPLIANCE FUGITIVE DUST CONTROL PLAN

ANNUAL CCR FUGITIVE DUST CONTROL REPORT

Annual CCR Fugitive Dust Control Report

CCR Dust Control Plan

Annual CCR Fugitive Dust Control Report

Annual CCR Fugitive Dust Control Report

Annual CCR Fugitive Dust Control Report

Annual Landfill Inspection 2015

COAL COMBUSTION RESIDUALS FUGITIVE DUST CONTROL PLAN

FUGITIVE DUST CONTROL PLAN HUNTLEY GENERATION STATION 3500 RIVER ROAD TONAWANDA, NEW YORK. PREPARED FOR: Huntley Power, LLC Tonawanda, New York

Fugitive Dust Control Plan Sherburne County Generating Plant

Annual Inspection Report Jeffrey Energy Center Flue Gas Desulfurization (FGD) Landfill

FUGITIVE DUST CONTROL PLAN

40 CFR Part 257. Rollin M. Schahfer Generating Station

Annual CCR Fugitive Dust Report. TS Power Plant. Eureka County, Nevada

FUGITIVE DUST CONTROL PLAN DUNKIRK GENERATION STATION 106 POINT DRIVE NORTH DUNKIRK, NEW YORK. PREPARED FOR: Dunkirk Power, LLC Dunkirk, New York

Liner Design Criteria Report Jeffrey Energy Center Inactive Bottom Ash Pond

Annual CCR Fugitive Dust Control Report. Tucson Electric Power Company Springerville Generating Station Springerville, Arizona

NELSON PLANT CCR FUGITIVE DUST CONTROL PLAN

Prepared for: IPA OPERATIONS, INC. Coleto Creek Power, LLP Fannin, Texas. Prepared by:

CCR COMPLIANCE FUGITIVE DUST CONTROL PLAN. Prepared for: Tucson Electric Power Company Springerville Generating Station Springerville, Arizona

Annual Fugitive Dust Report for the Walter Scott, Jr. Energy Center

Annual Fugitive Dust Report for the Walter Scott, Jr. Energy Center

APPALACHIAN POWER COMPANY

AEP GENERATION RESOURCES

AEP GENERATION RESOURCES

CCR RULE FUGITIVE DUST CONTROL PLAN

Appalachian Power Company Clinch River Plant. Coal Combustion Residuals Fugitive Dust Control Plan

KENTUCKY POWER COMPANY

COAL COMBUSTION RESIDUALS FUGITIVE DUST CONTROL PLAN

CCR COMPLIANCE FUGITIVE DUST CONTROL PLAN. Prepared for: NRG Power Midwest LP Cheswick Generating Station Springdale, Pennsylvania.

KENTUCKY POWER COMPANY

Coal Combustion Residuals Fugitive Dust Control Plan

AEP INDIANA MICHIGAN POWER COMPANY

Coal Combustion Residuals Fugitive Dust Control Plan

INITIAL RUN-ON AND RUN-OFF CONTROL SYSTEM PLAN Sibley CCR Landfill Sibley Generating Station East Johnson Rd Sibley, Missouri

2015 ANNUAL ENGINEERING INSPECTION REPORT ENTERGY WHITE BLUFF PLANT CLASS 3N LANDFILL PERMIT NO S3N-R3 AFIN:

2017 ANNUAL ENGINEERING INSPECTION REPORT ENTERGY INDEPENDENCE PLANT CLASS 3N LANDFILL PERMIT NO S3N-R2 AFIN:

2015 ANNUAL ENGINEERING INSPECTION REPORT ENTERGY INDEPENDENCE PLANT CLASS 3N LANDFILL PERMIT NO S3N-R2 AFIN:

Alma Offsite Landfill Phase IV S2180 State Hwy 35 Alma, Wisconsin

RULE 8021 CONSTRUCTION, DEMOLITION, EXCAVATION, EXTRACTION, AND OTHER EARTHMOVING ACTIVITIES (Adopted November 15, 2001; Amended August 19, 2004)

LANDFILL POST-CLOSURE PLAN ENTERGY ARKANSAS, INC. INDEPENDENCE PLANT CLASS 3N CCR LANDFILL PERMIT NO S3N-R2 AFIN

SOUTHWESTERN ELECTRIC POWER COMPANY

SOUTHWESTERN ELECTRIC POWER COMPANY

SOUTHWESTERN ELECTRIC POWER COMPANY

2015 ANNUAL ENGINEERING INSPECTION REPORT PLUM POINT ENERGY STATION CLASS 3N LANDFILL PERMIT NO S3N AFIN:

ANNUAL LANDFILL INSPECTION REPORT. Sunflower Electric Power Corporation Holcomb Station Unit # Holcomb Lane / P.O. Box 430 Holcomb, KS 67851

Fugitive Dust Management Plan

Jim Bridger Power Plant

Annual Inspection Report Lawrence Energy Center

Active Coal Combustion Residuals Landfill Annual Inspection Escalante Generating Station

Southwestern Electric Power Company

Southwestern Electric Power Company

ALLIANT ENERGY WISCONSIN POWER AND LIGHT COLUMBIA ENERGY CENTER CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT. January 15, 2016

Coal Combustion Residuals (CCRs)

ALLIANT ENERGY INTERSTATE POWER AND LIGHT OTTUMWA GENERATING STATION CCR SURFACE IMPOUNDMENT ANNUAL INSPECTION REPORT.

INITIAL HAZARD POTENTIAL CLASSIFICATION ASSESSMENT REPORT

Asbestos Dust Mitigation Plan Application 1. ADMINISTRATIVE INFORMATION

Building Better Storm Water Quality

WELSH POWER PLANT ASH LANDFILL. Run-on and Run-off Control System Plan

FUGITIVE DUST CONTROL PLAN FOR VULCAN MATERIALS COMPANY PLEASANTON FACILITY

Guidance for Filling Out An Application for an Earth Moving Permit / Dust Control Plan. Section 1 Applicant Information

Technical Memo. Alex Bumgardner, Austin Utilities. Dave Parenteau, PE, Wenck Associates, Inc. Date: December 15, 2015

Closure Plan Brame Fly Ash Pond

LANDFILL CLOSURE PLAN ENTERGY ARKANSAS, INC. INDEPENDENCE PLANT CLASS 3N CCR LANDFILL PERMIT NO S3N-R2 AFIN

Disposal of CCRs in Landfills and Impoundments

CCR Rule Operating Criteria Closure Plan

Asbestos Dust Mitigation Plan Application 1. ADMINISTRATIVE INFORMATION

Post-Closure Plan Jeffrey Energy Center Flue Gas Desulfurization (FGD) Landfill

Overview of the EPA RCRA Coal Ash Rule

CHOLLA POWER PLANT FLY ASH POND INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN CH_InflowFlood_002_

Guidance for Filling Out An Application for an Earth Moving Permit / Dust Control Plan. Section 1 Applicant Information

Closure Plan Jeffrey Energy Center Fly Ash Landfill

Guidance for Filling Out An Application for an Earth Moving Permit / Dust Control Plan. Section 1 Applicant Information

Content Copy Of Original Ministry of the Environment, Conservation and Parks Ministère de l Environnement, de la Protection de la nature et des Parcs

Pond Closures: Solving a Complicated Puzzle

SECTION AIR POLLUTION AND HAZARDOUS WASTE CONTROLS

CLOSURE PLAN ECONOMIZER ASH AND PYRITES PONDS AND WEST SLAG DISPOSAL POND

Written Closure Plan. Valmont Station - Boulder, Colorado Active CCR Landfill Public Service of Colorado (PSCo) Denver, Colorado

1. Introduction Site Information Site Characteristics Hydrogeologic Setting... 2

DUST CONTROL MEASURES

David Miller, P.E.- Atlanta. The New Coal Ash Regulations Wednesday, May 6, 2015

FOUR CORNERS POWER PLANT POST-CLOSURE PLAN (d) LINED DECANT WATER POND (LDWP) FC_PostClosPlan_009_

ENVIRONMENTAL ENGINEERING LAND SURVEYING

FOUR CORNERS POWER PLANT POST-CLOSURE PLAN (d) LINED ASH IMPOUNDMENT (LAI) FC_PostClosPlan_008_

INITIAL HAZARD POTENTIAL CLASSIFICATION ASSESSMENT REPORT. Fly Ash Impoundment KCP&L Greater Missouri Operations Company Sibley Generating Station

Transcription:

HALEY & ALDRICH, INC. 6500 Rockside Road Suite 200 Cleveland, OH 44131 216.739.0555 MEMORANDUM File No. 41938-009 SUBJECT: CCR Fugitive Dust Control Plan - Initial Jeffrey Energy Center St. Marys, Kansas This CCR Fugitive Dust Control Plan addresses the requirements of 257.80 Air Criteria of the USEPA s Final CCR Rule dated April 17, 2015 for Westar Energy Inc. s (Westar) Jeffrey Energy Center. This Plan has been developed based upon information provided by Westar and the Plan describes the CCR units and handling areas at the facility along with the dust control measures that are planned to be implemented by the Owner (Westar) and any handling Operators to minimize fugitive dust from becoming airborne. This plan is in addition to any other applicable Occupational Safety and Health Act (OSHA) standards applicable to this facility. I. Site Name and Location Jeffrey Energy Center (JEC) 25905 Jeffrey Road St. Marys, KS 66536 The general location of the facility is provided in Figure 1. II. CCR Management Areas Temporary Storage Areas Fly ash and economizer ash (a different fraction of the fly ash generated at the plant) are initially collected within enclosed structures at the plant. Fly ash is pneumatically blown into a silo which is then loaded into enclosed trucks for either off-site beneficial use or disposal at the on-site landfill. Economizer ash is transported to the Fly Ash area where it is stored until eventual off-site transfer for beneficial use. If not used beneficially, the economizer ash can be disposed of in the Fly Ash Area 1. Flue gas desulfurization (FGD) gypsum is generated at the plant, dewatered, and temporarily stored in enclosed staging areas. The material that is staged is managed and then loaded and hauled either offsite for beneficial use or to the on-site FGD Scrubber Gypsum Landfill. www.haleyaldrich.com

Westar Energy, Inc. Page 2 CCR Impoundments Westar is currently permitted to manage and dispose of CCR materials in an area west of the plant through solid waste Permit No. 359 issued by the Kansas Department of Health and Environment (KDHE). Within this permit boundary, Westar operates one active CCR impoundment at JEC. The Bottom Ash Area 1 Impoundment receives direct sluice bottom ash and plant process water. The settled solids are excavated, loaded, and hauled off-site for beneficial use. The decant water from this impoundment discharges into the Bottom Ash Pond to the west. The Bottom Ash Pond no longer receives CCR materials and is inactive. CCR Landfills There are three active CCR landfills at JEC within the Permit No. 359 boundary. Bottom Ash Area 1 Landfill is located east of the Bottom Ash Area 1 impoundment and receives excavated bottom ash that has been excavated from the impoundment and dewatered. Fly Ash Area 1 is located to the north of the Bottom Ash Pond and receives dry fly ash for disposal. The FGD Scrubber Gypsum Landfill is located south of the Bottom Ash Pond and receives the FGD gypsum that is intended for disposal. There are additional planned phases for the FGD Scrubber Gypsum Landfill that will be future lateral expansions. There are also planned and KDHE permitted landfill phases for bottom ash and fly ash that may be constructed in the future. Haul Roads Both paved and unpaved roads are used to transport CCRs either off-site from the temporary storage areas or Bottom Ash Area 1 or to the on-site landfills. III. CCR Fugitive Dust Control Methods This section outlines the general CCR related fugitive dust control measures based on unit and handling activity. These measures are being implemented based on the types of CCRs being managed and the site-specific facility operation. This eastern portion of Kansas has moderate weather conditions and receives approximately 31 inches of rain annually per the National Weather Service (based on Topeka, KS data). This moisture, combined with temperate climates, in conjunction with the noted dust control methods are suitable measures for minimizing dust generation. Bulk Material Handling The referenced fly ash and economizer ash silos are above ground silos that have controlled loading into enclosed haul trucks. Trucks enter under the silos on a concrete pad for loading. A chute is lowered on top of the truck and the CCR is then loaded into the enclosed truck. The trucks are equipped with lids that are closed mechanically or manually once loading of the fly ash is complete and the chute is removed. Fugitive dust potential is minimized by minimal exposure of CCR to the atmosphere through this temporary storage and loading process. In the event that de minimis amounts of CCRs are observed on the loading pad, the CCRs are collected and properly disposed. In addition, Westar may choose to load the fly ash into rail cars. The rail cars would enter under the silo and be loaded similar to that as described above.

Westar Energy, Inc. Page 3 FGD gypsum that is initially handled at the plant is stacked in three separate containerized areas which have controls in place to act as barriers against wind. These areas rely on front end loaders to load haul trucks for either off-site beneficial use or on-site disposal at the FGD Scrubber Gypsum Landfill. Haul trucks then utilize canopies to protect the CCR material to minimize dust generation. The active Bottom Ash Area 1 Impoundment is managed by intermittent excavation of settled bottom ash and dewatering of the material within the impoundment footprint. The dewatered material is then loaded into trucks with mechanically closed canopies which minimize potential dust generation and hauled off-site for beneficial use or placed in the Bottom Ash Area 1 Landfill footprint. The stacked material retains a level of moisture that prevents dust generation. If Westar identifies that the stacked material needs additional measures to limit dust generation, either water or a chemical suppressant may be applied. Unit Wind-Blown Dust Management CCR impoundments The following measures will be used to minimize fugitive dust generation at the active Bottom Ash Area 1 Impoundment: A portion of the settled material may become exposed above the water surface elevation. Westar will monitor any exposed areas and apply water or a chemical dust suppressant as appropriate. Maintain a crust and/or appropriate moisture on exposed areas susceptible to fugitive dust generation. Bottom Ash Area 1 Landfill, Fly Ash Area 1 and FGD Scrubber Gypsum Landfills The following measures will be used to minimize fugitive dust generation at the CCR landfills: CCRs will be placed onto the ground from the haul trucks using minimal drop heights. CCRs will not be placed when wind speeds exceed sustained 15 miles per hour (mph). Haul trucks will limit travel speeds to less than 15 mph on active areas. Abrupt starts, stops, and turns will be avoided within the working face. Chemical dust suppressants may be used to minimize fugitive dust. Areas reaching final grades will receive appropriate cover materials in accordance with the applicable state permit requirements. Haul Roads The following dust control measures will be used for CCR haul roads, as appropriate: Posted speed limits will be in effect on facility roads. CCR haul roads will be cleaned in a timely manner. General Housekeeping Spilled and/or deposited CCR within the facility will be cleaned in a timely manner.

Westar Energy, Inc. Page 4 IV. Citizen Complaints Westar will keep a log of citizen complaints involving CCR fugitive dust events at the facility. Information to be recorded includes dates and time of complaint, the telephone number and addresses of the citizen, a description of the complaint, and any corrective measures taken to address the complaint. See Appendix A for an example table to be completed. Westar will accept citizen complaints in writing only to the following addresses: By Post: Westar Energy Inc. ATTN: Environmental Manager, Water and Waste Programs P.O. Box 889 Topeka, KS 66601 Or, electronically: WestarCCR@westarenergy.com V. Amendment of the Plan Plan Assessment Westar will periodically assess the current Plan to determine if any amendments are prudent based on changes to CCR units (e.g. expansions, closures) and the adequacy of dust control measures being implemented to meet the performance standard of the regulation. To assess the current Plan, Westar s designated person will: Review citizen complaints logged. Visually inspect and monitor CCR areas weekly. At a minimum, assess plan in an annual meeting with operations personnel to determine if revisions are necessary. Plan Amendment Based on the periodic assessment, Westar may choose to amend this Plan if measures are deemed ineffective or if changes to the areas being managed, the dust control measures, and/or other operating practices to continue compliance with the regulatory standards. Amendments to the current Plan will be completed in accordance with 257.80(b)(6) of the Final CCR Rule. Any amendment to the Plan will be certified by a qualified professional engineer.

Westar Energy, Inc. Page 5 A record of amendments to the Plan will be tracked below. The latest version of the report will be noted in the subject line of the Plan. Version Date Description of Changes Made Initial 10/15/2015 Initial Issuance VI. Annual CCR Fugitive Dust Control Report Westar Energy Inc. will prepare an annual report in accordance with 257.80(c) of the Final CCR Rule. The report will be placed in the operating record for the facility and appropriate notifications and recordkeeping actions will be completed. VII. Attachments Figure 1 Project Locus Figure 2 CCR Fugitive Dust Control Plan Management Areas Appendix A CCR Fugitive Dust Event Citizen Complaint Log VIII. Professional Engineer Certification I certify that this CCR fugitive dust control plan meets the USEPA s Final CCR Rule requirements of 257.80 for Westar Energy s Jeffrey Energy Center. _Steven F. Putrich, P.E. Certifying Engineer

SITE G:\41938_JEC\Global\GIS\MapProjects\41938-0009-0001-ProjectLocus.mxd MAP SOURCE: ESRI SITE COORDINATES :39 16'22.45"N, 96 8'47.80"W JEFFREY ENERGY CENTER ST MARYS, KANSAS PROJECT LOCUS APPROXIMATE SCALE: 1 IN = 5,000 FT OCTOBER 2015 FIGURE 1

UNPAVED ROAD FLY ASH AREA 1 LANDFILL BOTTOM ASH AREA 1 IMPOUNDMENT FLY ASH SILOS PAVED ROAD BOTOM ASH POND FGD SCRUBBER GYPSUM STAGING AREAS VARI, KATALIN Printed: 10/15/2015 2:27 PM Layout: HA-FIG-B-L-H \\COL\COMMON\PROJECTS\41938_WESTAR-CCR COMPLIANCE\09_JEFFREY\JEFFREY.DWG LEGEND GENERAL LANDFILL BOUNDARY APPROX. LIMITS OF ACTIVE CCR (LANDFILL/ IMPOUNDMENT) UNITS APPROX. LIMITS OF INACTIVE AND/OR EXEMPT CCR UNITS APPROX. LOCATIONS OF CCR GENERATION/HANDLING PAVED CCR ACCESS ROAD UNPAVED ROAD NOTES: ACTIVE FGD SCRUBBER GYPSUM LANDFILL FUTURE FGD SCRUBBER GYPSUM LANDFILL 1. IMAGE SOURCE: GOOGLE EARTH PRO, DATED 05/03/2014. 2. THIS MAP SHOWS THE APPROXIMATE LOCATIONS OF THE CCR MANAGEMENT UNITS AND ASSOCIATED HANDLING INFRASTRUCTURE LOCATIONS. THE CCR FUGITIVE DUST CONTROL PLAN IS DEVELOPED TO MINIMIZE DUST IN ACCORDANCE WITH 257.80 OF THE FINAL CCR RULE (80 FR 74: 21302-21501. APRIL 17, 2015). 3. THIS FUGITIVE DUST CONTROL PLAN IS APPLICABLE TO THE CCR HANDLING LOCATIONS SHOWN BASED ON WESTAR CCR UNIT AND MANAGEMENT DESIGNATIONS AS OF THE DATE OF THIS FIGURE. BOTTOM ASH AREA 1 LANDFILL ECONOMIZER ASH SILOS 0 1200 2400 SCALE IN FEET WESTAR ENERGY, INC. JEFFREY ENERGY CENTER ST MARYS, KANSAS CCR FUGITIVE DUST CONTROL PLAN MANAGEMENT AREAS SCALE: AS SHOWN OCTOBER 2015 FIGURE 2

WESTAR ENERGY JEFFREY ENERGY CENTER CCR FUGITIVE DUST EVENT CITIZEN COMPLAINT LOG Complaint ID Date & Time of Complaint Complainant Name Complainant Phone Number Complainant Address Complaint Corrective Measures Taken to Address Complaint