INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK

Similar documents
Metal Building Roof Curbs

TYPICAL ROOF CONDITION LAYOUT

Pre-Fabricated Roof Curbs

Architectural Roof and Wall Products Guide Specifications

Equipment Mounting Supports

Architectural Wall Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

Architectural Roof Products Guide Specifications

Architectural Roof Products Guide Specifications

RS32 Multi-Section Skylight System under/over seam clip double diverter

PIPE PORTAL SYSTEMS EQUIPMENT RAILS ROOF CURBS Roof Products & Systems

CONTINUOUS VENTILATORS

Pre-Fabricated Roof Curbs

DL-200. Specifications

RS24-10 Single-Section Skylight System

Light-Metal Roof Edge, Raised

SSL-175. Specifications

SHURLOC 150 STANDARD DETAILS

Central Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

Architectural Roof and Wall Products Guide Specifications

SECTION 07530CP EPDM MEMBRANE ROOFING

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

Tuscaloosa Police Station

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

FACE CFP - HORIZONTAL PANELS - OPTION 'B'

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

SECTION METAL ROOF PANELS

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH

Central Texas Metal Roofing Supply Co., Inc 36" SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ NET COVERAGE

TATA BLUESCOPE STEEL LIMITED PRODUCT SPECIFICATION LANGUAGE FOR PRE ENGINEERED STEEL BUILDING (BUTLER BUILDING SYSTEM- WITH MR-24 ROOF SYSTEM)

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #2, January 26, 2017

SECTION METAL ROOF AND SOFFIT PANELS

SECTION HVAC GRAVITY VENTILATORS

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

SECTION AWNINGS

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

UltraLok Roof System Product Application Guide INDEX

TRIAD CORRUGATED METAL, INC.

Specifications for FL-100 Soffit Panel

SECTION PRE-ENGINEERED METAL BUILDING

Sheet Metal Flashing and Trim

TRIAD CORRUGATED METAL, INC.

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

Central Texas Metal Roofing Supply Co., Inc SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

MicroMetl ISOLATION CURB CATALOG. for York ZH,DH,DM,BP ; DF ; DJ 150; DR ;ZF,ZJ 150

For Metal Roofing Systems Fascia, Mansards,& Soffits

Classic Rib Roofing Panels DETAIL MANUAL

SIDEWALL/ENDWALL STANDING SEAM TRIMS SIDEWALL/ENDWALL CROSS SECTION NTS SIDING OR OTHER WALL CLADDING, TYP LOW PROFILE FASTENER, TYP

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

a division of NCI Standing Seam Roof Systems

SECTION / / BULLET RESISTANT SOUND CONTROL WINDOWS

238T and 138T Panel and Accessories Price List 9/29/2017 (price good for shipments through 11/31/2017) Customer Job Date Sales Rep 238T PANEL ITEM #

SECTION PRE-ENGINEERED BUILDING INSULATION

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

The better way to build TM. Installation Manual NAILBASE PANELS

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

STEEL DECK INSTITUTE Industry Standard Terms & Definitions

Industry Standard Terms & Definitions Of The Steel Deck Institute

Flat Bank SERIES 05FB AND 07FB. Options CONSTRUCTION FEATURES EQUIPMENT OPTIONS PRODUCT DATA CLEAN-LINE TM SERIES 05FB/07FB PD-CLFB-03A JANUARY 2003

SECTION ROOF SPECIALTIES

B.01. Lincoln Property Company 100 Lowell Road North Reading, MA 01864

When Time is Everything... We Manufacture in Days - N ot Weeks!

Fundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL

SPECIFICATIONS Section Cantilevered Walkway Cover


A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS

ALLMET CONTINENTAL INSTALLATION GUIDE

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

SECTION STAINLESS STEEL WALL PANELS

Metafor Panel System Installation Guide

SECTION STEEL DECKING

MAXIMA. Maxima Testing Data, Section Properties, and Load Tables

2016 CDM Smith All Rights Reserved July 2016 SECTION STEEL ROOF DECK

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

Pre-Installation See detail page for general notes concerning trim accessories, holes, fasteners, gaskets, caulking and support columns.

The Olympia Difference

Top Ten List: What Gets Metal Roof Designers in Trouble?

SIDEWALL/ENDWALL EXPOSED FASTENER TRIMS. Details master.dwg 2/15/2017 GULF COAST SUPPLY & MFG., LLC

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Catwalk Curbs. Service Platforms and Catwalks

SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS

SPECIFICATIONS Section Gable Walkway Covers

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

INSTALLATION GUIDE nailable rigid insulation substrate for roofing applications

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

Transcription:

INSTALLATION INSTRUCTIONS for MP-RC1 TWO PIECE CONSTRUCTION TO BE INSTALLED ON COMPLETED ROOF DECK A. 1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb width by outside curb length plus 9" for diverter plate. 2. Cut openings in roof panel and install support framing for roof curb and equipment loads. Support at least two parallel curb walls. Avoid cantilever sections over 1' in length. B. 3. Apply wide tape caulk to diverter plate top sides and upper edge. 4. Align diverter plate ribs with roof deck ribs and slide diverter plate beneath roof panel. 5. Fasten diverter plate to roof panel and sub-framing using suitable fasteners compatible with roof system. A minimum of four fasteners per side spaced on 3" centers or less as roof system permits. Fasteners should withstand a minimum pullout force of 150# each. C. 6. Apply continuous tape caulk at least 2-1/2" wide around remaining roof opening. 7. Position curb so that corrugation on curb flanges mate on top of corresponding corrugations of roof panel on eave side of opening. 8. Fasten curb to roof panel and diverter plate in accordance with step 5. MP-RC1 D. 9. Inspect all joints and fasteners in curb flanges. Caulk diverter plate and roof curb flanges to seal out moisture. 10. Apply a closed cell neoprene strip to top rail of roof curb before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners.

Customer: Ship To: Metallic Products RIDGE MOUNT ROOF CURB Factory Installed Corrugation MP-RC2 STANDARD FEATURES 1. 16 gauge galvanized steel shell and baseplate 2. Corners mitered and welded watertight 3. Curbs prime painted after fabrication 4. Internal angle reinforcing when specified 5. Water diverter angle 6. 6" minimum height on ridge side 7. 1-1/2" 3# density insulation when specified Order No.: Job No.: Order Date: Due Date: ADDED OPTIONS 1. 2. 3. MATCH ROOF PANEL NO. REQ'D DIM. A DIM.B DIM.C H L TAG DESCRIPTION Page of RC-2 / Rev. 2/01 METALLIC PRODUCTS Houston, Texas 77018 (713) 688-6624 Fax (713) 688-2077 Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC2 FOR INSTALLATION OVER ROOF PANELS A. 1. On fully sheeted roof, locate and mark center line of roof opening on ridge. 2. Using distance from center line to major ribs as a guide, layout and mark roof opening to curb inside dimensions. B. 3. Cut out roof opening to I.D. of curb, plus an additional 1-1/2" of the major ribs on the eave sides of the opening to allow the curb to seal to flat of roof deck. 4. Install structural support framing for roof curb and equipment loads beneath roof curb and equipment loads beneath roof curb walls and flanges around opening. Keep I.D. clear. C. 5. Turn roof curb upside down and apply tape caulk to curb flanges. 6. Press the curb in place on the roof deck. Fasten curb to support steel through curb flange and roof deck using suitable fasteners compatible\with roof system. A minimum of four fasteners per side spaced on 3" centers or less as roof system permits. Fasteners should withstand a minimum pullout force of 150# each. D. 7. Seal edge of roof curb flange with silicone caulk to assure watertight weather seal. 8. Apply a closed cell neoprene strip to top rail of roof curb before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners. RC-2/2

Customer: Metallic Products RIDGE MOUNT ROOF CURB No Corrugation MP-RC3 Ship To: STANDARD FEATURES 1. 16 gauge galvanized steel shell and baseplate 2. Corners mitered and welded watertight 3. Curbs prime painted after fabrication 4. Internal angle reinforcing when specified 5. Water diverter angle 6. 6" minimum height on ridge side 7. 1-1/2" 3# density insulation when specified Order No.: Job No.: Order Date: ADDED OPTIONS 1. 2. 3. Due Date: NO. REQ'D O.D. DIM. H L TAG DESCRIPTION Page of RC-3 / Rev. 2/01 METALLIC PRODUCTS Houston, Texas 77018 (713) 688-6624 Fax (713) 688-2077 Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC3 RIDGE MOUNT ROOF CURBS To Be Installed Beneath Roof Deck A. 1. After building framing is complete, locate roof opening and install support framing for roof curb and equipment loads. 2. Set and secure roof curb in place on support framing. At least two parallel curb walls must be on support framing. Loads shall not be supported by a cantilever section exceeding 1' in length. B. 3. Cut roof panels to fit snugly around curb walls. 4. Apply a wide band of tape caulk to top side of curb flanges. 5. Install and seal closure strips as required. Press roof panels into position. C. 6. Fasten roof panel through curb flanges to support steel using suitable fasteners compatible with roof system. A minimum of four fasteners per side spaced on 3" centers or less as roof system permits. Fasteners should withstand a minimum pullout force of 150# each. D. 7. Inspect installation and fasteners. Apply silicone sealant to seal seams around all sides of curb to assure a watertight seal. 8. Apply a closed cell neoprene strip to top rail of roof curb before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners. RC-3/2

Customer: Ship To: Order No.: Job No.: Order Date: Due Date: Metallic Products SLOPE MOUNT ROOF CURB Over Panel Installation, Shop Located, Factory Installed Corrugation MP-RC4 STANDARD FEATURES 1. 16 gauge galvalume steel shell and baseplate 2. Corners mitered and welded watertight 3. Welds prime painted after fabrication 4. Additional reinforcing when specified 5. Water diverter 6. 6" minimum height on ridge side 7. 1-1/2 " 3# density insulation when specified ADDED OPTIONS 1. 2. 3. MATCH ROOF PANEL NO. REQ'D DIM. A DIM.B DIM.C H L TAG DESCRIPTION Page of RC-4 / Rev. 2/01 METALLIC PRODUCTS Houston, Texas 77018 (713) 688-6624 Fax (713) 688-2077 Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC4 FOR INSTALLATION OVER ROOF PANELS A. 1. On fully sheeted roof, locate and mark center line of roof opening. 2. Using distance from center line to major ribs as guide, layout and mark roof opening to curb outside dimensions. B. 3. Cut out roof opening to O.D. of curb, plus an additional 6" of the major ribs on the ridge side of the opening to allow the curb's water diverter area to seal to flat of roof deck. 4. Install structural support framing for roof curb and equipment loads beneath roof curb walls and flanges around opening. Keep I.D. clear. C. 5. Turn roof curb upside down and apply tape caulk to curb flanges. 6. Press the curb in place on the roof deck. Fasten curb to support steel through curb flange and roof deck using suitable fasteners compatible with roof system. A minimum of four fasteners per side spaced on 3" centers or less as roof system permits. Fasteners should withstand a minimum pullout force of 150# each. D. 7. Seal edge of roof curb flange with silicone caulk to assure watertight weather seal. 8. Apply a closed cell neoprene strip to top rail of roof curb before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners. RC-4/2

Customer: Ship To: Metallic Products SLOPE MOUNT ROOF CURB Shop Located, Shingle Type, Factory Installed Corrugation MP-RC5 STANDARD FEATURES 1. 16 gauge galvalume steel shell and baseplate 2. Corners mitered and welded watertight 3. Welds prime painted after fabrication 4. Additional reinforcing when specified 5. Water diverter 6. 6" minimum height on ridge side 7. 1-1/2" 3# density insulation when specified Order No.: Job No.: Order Date: Due Date: ADDED OPTIONS 1. 2. 3. MATCH ROOF PANEL NO. REQ'D DIM. A DIM.B DIM.C H L TAG DESCRIPTION Page of RC-5 / Rev. 2/01 METALLIC PRODUCTS Houston, Texas 77018 (713) 688-6624 Fax (713) 688-2077 Toll Free (800) 356-7746

INSTALLATION INSTRUCTIONS for MP-RC5 ONE PIECE CONSTRUCTION Must Be installed as Deck is Being Laid A. 1. As roof sheets are being installed, locate roof curb opening and install support framing for roof curb and equipment loads. Support at least two parallel curb walls. Avoid cantilever sections over 1' in length. 2. Trim and install panels on the left, right and below (eave side) of roof opening. Take care to keep area of curb I.D. clear. 3. Apply tape caulk to roof deck around roof opening, 2" from edge of opening. B 4. Set curb in place and press flanges into mastic. Curb should be secured through roof deck to sub-framing using suitable fasteners compatible with roof system. A minimum of four fasteners per side spaced on 3" centers or less as roof system permits. Fasteners should withstand a minimum pullout force of 150# each. C. 5. Apply sealant tape to leading edge of curb flange and press ridge side roof panels into position over flange and corrugation closure ribs. Seam roof panels and secure through curb flange into support steel as in step 4. Seal end of corrugation to pre-formed metal rib to prevent capillary action of moisture. D. 6. Check tightness of fasteners and curb installation, caulk perimeter edge of curb and flanges of roof panel to seal moisture out. 7. Apply a closed cell neoprene strip to top rail of roof curb before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners. RC-5/2

Customer: Ship To: Order No.: Job No.: Order Date: Due Date: Metallic Products SLOPE MOUNT ROOF CURB No Corrugation, For Over & Under Deck Installation MP-RC6 STANDARD FEATURES 1. 16 gauge galvalume steel shell and baseplate 2. Corners mitered and welded watertight 3. Curbs prime painted after fabrication 4. Additional reinforcing when specified 5. Water diverting cricket 6. 6" minimum height on ridge side 7. 1 1 / 2" 3# density insulation when specified ADDED OPTIONS 1. 2. 3. MATCH ROOF PANEL (LOOSE RIBS) FRONT FLANGE UNDER PANEL AND REAR FLANGES OVER PANEL DIM. A 9 " CURB O.D. 6" 1 1 2" Insulation DIM. B 6" CURB O.D. 6" C L A A 1 1 2" Section A-A Insulated When Specified PLAN NO. REQ D H 12 ELEVATION PITCH DIM. A DIM B H L L TAG DESCRIPTION Section A-A Uninsulated Page RC-6 / Rev. 2/01 of METALLIC PRODUCTS Houston, Texas 77018 (713) 688-6624 Fax (713) 688-2077 Toll Free (800) 356-7746

4" END CAPS RIB PROFILE ROOF CURB NOTCHED FOR PANEL RIBS SEALANT TAPE CL OF MAJOR RIB 2 3 4" 2 3 4" NOTE: Field Notch Skirt for Lower Edge Ribs. 3" SECTION THRU ROOF SLOPE RIBBED ROOF PANEL PREPARED FOR CURB 3" 9" STD. 6" CURB DIM. O/D 1 1 2" OPENING DIM. 1 1 2" Structure - Not by M.P. Note: Sealant Tape Must Be Applied to All Four Sides END CAP (OVER PANEL) SEALANT TAPE LOWER EDGE DETAIL Structure - Not by M.P. SEALANT TAPE CURB OPENING 1 1 2" ROOF PANEL SIDE DETAIL SEALANT TAPE Structure - Not by M.P. 3" END CAP (UNDER PANEL) SECTION @ SIDE UPPER EDGE DETAIL DATE: TITLE: 3306 Ella Blvd. Houston, TX 77018 (713) 688-6624 1-800-356-7746 E-mail: info@mpvent.com PART: 9/95 INSTALLATION INSTRUCTIONS ROOF CURB MPD-25 3" 6" STD. 3"

Customer: Metallic Products SLOPE MOUNT ROOF CURB Floating Curb w/sub Framing MP-RC7 Ship To: STANDARD FEATURES 1. 16 gauge galvalume steel shell and baseplate 2. Corners mitered and welded watertight 3. Curbs prime painted after fabrication 4. Internal angle reinforcing when specified 5. 6" minimum height on ridge side 6. 1-1/2" 3# density insulation when specified Order No.: Job No.: Order Date: ADDED OPTIONS 1. 2. 3. Due Date: NO. REQ'D DIM. A DIM.B H L TAG DESCRIPTION Page of RC-7 / Rev. 2/01 METALLIC PRODUCTS Houston, Texas 77018 (713) 688-6624 Fax (713) 688-2077 Toll Free (800) 356-7746