AIR QUALITY IN COW HOUSES WITH CURTAIN WALL VENTILATION IN FINNISH CLIMATE

Similar documents
Measurement and Modelling of Circumstances in Animal Houses: What, Why and How

Many issues to consider when planning & designing a new dairy facility- Process Flows Water Flow Land Flow Manure Flow Cow Flow Feed Flow Traffic Flow

Methane emission from naturally ventilated livestock buildings can be determined from gas concentration measurements

Air Quality and Indoor Environment of Compost Bedded Dairy Barns in Ohio

Infiltration simulation in a detached house empirical model validation

Work Package 2: Performance of naturally ventilated buildings

Cow Comfort and Cooling. Joseph M. (Joe) Zulovich, Ph.D., P.E. Extension Agricultural Engineer University of Missouri

Moisture and temperature conditions in cold lofts and risk of mould growth

Chapter 7. Passive Solar Contents

Managing Heat Stress in Dairy Cows

Work Package 2: Performance of naturally ventilated buildings

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

Propane Saving in Poultry Farm through Waste Heat Recovery System

RESULTS OF LONG-TERM ENERGY EFFICIENCY MONITORING OF TEST BUILDINGS UNDER REAL CLIMATIC CONDITIONS

BIPV/T + ASHP - TECHNOLOGIES FOR NEAR AND NET- ZERO ENERGY BUILDINGS

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

Hygrothermal Performance of Timber External Walls Insulated with Natural and Industrial Materials

Air distribution and temperature control in classrooms

Live Transportation Research and Improvement Initiatives

Passive cooling effect of building features in traditional Japanese buildings

SunCatcher Design GroupTM

Improving Energy Efficiency in Buildings (IEEB) Energy Quarter, Ritaharju Monitoring

NZEB: The new challenge of HVAC Manufacturers. ASTRO Tower (Archi Urbain)

RENEWABLE & EFFICIENT ENERGY SYSTEMS FOR MIDWEST FARMS. Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center

IMPACT OF FREQUENCY OF FEEDLINE SOAKING COMBINED WITH EVAPORATIVE AIR COOLING IN A HUMID ENVIRONMENT

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Measurements of Energy Performance and Indoor Environmental Quality in 10 Danish Passive Houses Larsen, Tine Steen; Jensen, Rasmus Lund

Energy Saving Public Swimming Complex In Finland

317: Thermal performance of houses located in Florianópolis, southern Brazil

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

Welcome to this continuing education seminar. This is the first of two parts of the High- Performance Building series.

Evaluation of natural ventilation systems in a landscaped office.

FAST DRYING CONCRETE

CONTROLLED BUILDING ENVELOPES FOR ENERGY STORAGE. A. Borodinecs, A. Kreslins. U. Bratuskins

Comparison of the Effects of Various Countermeasures on Energy Consumption in a Residential Building

Ventilation Solutions in Renovated Apartment Buildings in Cold Climate Conditions

NJF Report No Seminar No Technology for milking and housing of dairy cows. Hamar, Norway, Feb 2002

ECONOMIC HEATING SYSTEMS FOR LOW ENERGY BUILDINGS IN SWEDEN

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Energy Efficient Health Centres 2018

Effect of energy renovation on thermal sensation and comfort

RELATION BETWEEN THE INDOOR AND OUTDOOR CLIMATE IN UNINSULATED COWSHEDS

CEN/TC 89 - Thermal performance of buildings and building components

PRINCIPLES AND POTENTIALS OF VENTILATIVE COOLING

CAE 331/513 Building Science Fall 2017

Commissioning of a Coupled Earth Tube and Natural Ventilation System at the Post-Acceptance Step

Calf house Ventilation

Thermal comfort study of a hawker center in Singapore

Role of Passive Solar Green Houses in Nutrition Sensitive Agriculture in Mountains

Sloped Roofs vs Walls. Problems. Review Roof Components. University of Waterloo and Balanced Solutions

A Method for On-Going Commissioning of VRV Package Systems Using a. Simulation Model

RESEARCH OF SOLAR WATER HEATERS MODEL

07059, Antalya / TURKEY ABSTRACT

Introduction Retrofit interior insulation of masonry buildings Exterior insulation ideal solution Interstitial condensation, freeze thaw issues

EFFECTS OF WEATHERS AND INDOOR TEMPERATURES ON PERFORMANCE OF ENERGY RECOVERY VENTILATOR. Yanping Zhou, Jingyi Wu, Ruzhu Wang

A Solar Wall System Utilized in Rural Houses of Northeast China

Tage Møller Architect office building

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Adding glazing as an energy saving renovation measure in cold climates

Does NZEB pose a conflict to Good Indoor Air Quality? REHVA summit November 2017

Indoor comfort and air quality in spaces equipped with eco-ventilation systems

For all those with the ability to influence the design, layout or indoor air quality of buildings

Potential of natural ventilation in shopping centres

Energy consumption and thermal comfort in a passive house built in Romania

Work Package 2: Performance of naturally ventilated buildings

Air Quality in New Free-Stall Dairy Facilities

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE

The Influence of Operation Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner

Hourly Analysis Program v.4.1 Page 1 of 1

The BIG Energy Upgrade Energy Innovation for Retrofitting Deprived Community Housing in the UK

Effect of roofing material type on microclimate in the sheep buildings

Sapporo Net-Zero Energy Home Hokkaido, Japan. Description. Setting. Super E Canadian Member. Super E Japanese Member. Super E Case Study

Assessing Options for Ventilating Adult Cow Barns Making Sense of Too Many Choices!

The lotus flower: biomimicry solutions in the built environment

Passive houses for the Northern climate

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

Design and retrofitting of a hybrid building in Athens

F A M I L Y R E U N I O N

Advanced Ventilation Technologies

WUFI: Moisture Engineering in the 21 st Century (and Beyond)

Hourly Analysis Program v.4.1 Page 1 of 1

Impacts of energy retrofits on hygrothermal behavior of Finnish multi-family buildings


Study of the energy performance of a retrofitting office

790 sq miles / 2,038 sq kms

Figure 1. Basic principle of ventilation: fresh air mixes with shelter air contaminants and is discharged. CONTAMINATED AIR OUT MOISTURE MIXING GASES

Quality of compost and bedding issues ---- Compost Bedded Loose Housing Dairy Barn

IEA Annex 41 MOIST-ENG Whole Building Heat, Air and Moisture Response Comparison of measured and simulated moisture buffering results

Potential for Improved Outdoor Comfort by Design in U.S. Climates

Hourly Analysis Program v.4.1 Page 1 of 1

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Where,h(t)the indicial response of thermal flow rate, B 0 the

Introduction of Heat Insulation Solar Glass

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

Watering Facilities for Managed Grazing Systems. By Kevin Ogles and Michael Hall USDA/NRCS ENTSC GLCI Grazing Lands Specialists

Flexible Vapor Control Solves Moisture Problems of Building Assemblies - Smart Retarder to Replace the Conventional PE-Film

Cattle Housing and Ventilation

performance. In order to make clear the effects of thermal performance and lifestyle on thermal environment and energy consumption for well-insulated

Transcription:

ISAH-27 Tartu, Estonia 947 AIR QUALITY IN COW HOUSES WITH CURTAIN WALL VENTILATION IN FINNISH CLIMATE Kivinen, T. 1, Mattila, K.M. 2, Teye, F. 2, Heikkinen, J. 3 and Heimonen, I. 3 1 MTT Agrifood Research Finland, Animal Production Research, Vakolantie 55, FI-34 Vihti, Finland, tapani.kivinen@mtt.fi; 2 University of Helsinki, Department of Agrotechnology, Koetilantie 3, FI-14 University of Helsinki, Finland, frederick.kwameteye@helsinki.fi; 3 VTT, Indoor climate and building services, Lämpömiehenkuja 2, FI-244 VTT, Finland, jorma.heikkinen@vtt.fi, ismo.heimonen@vtt.fi ABSTRACT Most Finnish dairy barns old and new ones are ventilated with electric fans. Natural ventilation through wall curtains is a new technology in insulated dairy barns in Finland. The first equipment was assembled in 24 and today it is expected to become a challenging option for dairy farmers. The main object of this research was to find out first how this new technology fits into Finnish climate and secondly what is the of indoor air quality performance. The research had mainly two phases. First a field measurement session was carried out in three selected insulated barns which had been built recently and equipped with curtain walls. The measurements took place between February and March 26, a period for harsh frost. Instrumentation collected data from inside and outside temperature, relative humidity, wind and air velocity. Carbon dioxide and ammonia were recorded inside the barns as well as radiation and heat flow in the floor. Data was collected into computer data loggers. Secondly a year performance model was simulated according to the measured data. The model results reveal that curtain wall technology can be used in Finnish climate and it gives good air quality even in cold winter time air exchange situations. Summertime air quality is superb compare to electric fan solutions. The only negative points are a few frost days and high relative humidity inside the barn during wintertime. CURTAIN WALL TECHNOLOGIES IN MEASURED BARNS The field measurements were done in three cow houses in middle Finland. The oldest barn had been one year in operation and the youngest was brand new. The barns contained 12 14 cubicles. The floor area varied between 96 and 19 m 2. Wall curtains in all cases were hand adjusted by farmers intuition. The farmers made a book keeping about curtain openings so that this data was used in the final calculations. The year simulation was made according to animal heat, humidity, CO 2 production, ammonia production, milk yield and forage intake values. U- values in constructions were considered as they were built. Solar radiation, local long time climatic data were added into the formula.

948 ISAH-27 Tartu, Estonia Figure 1. Ventilation inlet and outlet technologies in measured barns. In all cases walls and roof were insulated, the inlet opening was one meter (when fully open) and outlet openings had several types, chimneys and the whole ridge long greenhouse hatches YEAR SIMULATION FOR VENTILATION AND AIR QUALITY The year simulation was calculated with a computer program created by VTT researchers. The simulation was based partly to the measured data and a long term weather data from Finnish meteorological institute. The simulation numbers were calculated for a barn with 124 cubicles, floor area 1245 m 2 and volume 635 m 3. The simulation barn had 8 milking cows and 3 heifers and dry cows. The total continuous energy produced by the animals was 13 kw. The walls and roof were thermal insulated. The floor had no insulation at all.

ISAH-27 Tartu, Estonia 949 temperature, C 3 25 2 15 1 5-5 -1-15 Indoor and outdoor temperatures for every hour during a year Indoor TEMP Outdoor TEMP -2-25 -3-35 1.1. 31.1. 1.3. 31.3. 3.4. 3.5. 29.6. 29.7. 28.8. 27.9. 27.1. 26.11. 26.12. months Figure 2. Indoor temperatures according to simulation The inside temperature will be controlled to maintain +4 +6 C level through autumn, winter and spring. For a few days in January February the inside temperature may go slightly under C due to extreme outdoor winter temperatures. The additional heating is needed under 23 C outdoor temperature if the farmer wanted to keep the inside temperature over C. Practically however indoor surfaces, drinking cup or water hoses do not freeze even if the additional heating didn t exist. Summertime indoor temperatures follow outdoor temperatures. Carbon dioxide is a rather good indicator for air quality and air exchange rate. The simulation indicates that CO 2 concentration is very acceptable. The maximum level in Finland is 3 ppm. It seems to exceed the limit only for 3,4% of all 876 hours a year during the coldest periods in wintertime when the ventilation is at its minimum. But in return the level remains mostly at 5 ppm for nearly 6 months a year. CO2 concentration, ppm 4 35 3 25 2 15 1 5 31.12. 19.2. 9.4. 29.5. 18.7. 6.9. 26.1. 15.12. months Figure 3. Carbon dioxide concentration according to simulation

95 ISAH-27 Tartu, Estonia The relative indoor humidity is hard to be controlled if judged according to CIGR recommendation for a dairy barn. Relative humidity occurs in intensively during the winter time, sometimes reaching 1% (dots over 1, in figure 4) and then the air becomes foggy. But the relative humidity exceeds the CIGR s 9-rule also between +5 and + 2 C which are springtime, autumn and summer temperatures as well. At the same time the barn can be too dry. This means that the barn is dependent on outdoor circumstances due to summertime day and night variation of temperature and humidity. But still the high relative humidity can be a threat to constructions especially for timber and steel. It also can cause mildew growth and premature decay on wood surfaces. relative humidity, % 12 11 1 9 8 7 6 5 4 3 2 Indoor humidity ( RH %) related to indoor temperature recommended area by CIGR -1-5 5 1 15 2 25 3 indoor temperature o C Figure 4. Indoor humidity according to simulation Technical assembly and detailing of the curtain makes the system vulnerable for air leakages. These leakages are not harmful. On the contrary they maintain the sufficient level of basic air exchange during the cold winter times when the curtain is closed. This feature practically keeps the minimum ventilation rate in proper level.

air exchange rate, times per hour ISAH-27 Tartu, Estonia 951 Air exchange rate (1/h) for every hour (876) related to outdoor temperature -35-3 -25-2 -15-1 -5 5 1 15 2 25 outdoor temperature, C Figure 5. Air exchange rate 2 18 16 14 12 1 8 6 4 2 Summer maximum Winter minimum The blue dots in figure 5 indicate the air exchange rate (times per hour) related to outdoor temperature. The winter minimum and summer maximum lines are indicate the ventilation rate requirements in Finnish legislation for animal husbandry buildings in agriculture. The winter minimum exchange rate can be achieved even in the coldest periods. When the outdoor temperature reaches C air moves and changes 6 1 times per hour. On a calm summer day air changes approximately 12 times and even 5 1 times on a windy day. The wall curtain system always guarantees minimum exchange and the maximum rate is well beyond requirement. This gives a good air exchange rate and thus appropriate air quality. CONCLUSIONS The curtain wall system appears to be an acceptable and functional ventilation concept for insulated dairy barns in Finnish climate if few inconveniences are accepted. These are slight frost days under zero and high relative humidity. In return the ideal temperature + 5 C can be maintained over 7 months in Finnish climate. Gas emissions are always in control and minimum air exchange is good and maximum exchange very good. The system also consumes very little electric power. If the barn of this size had electric fans the annual energy consumption could otherwise be 16 kwh. The system is also rather silent. These features give a good hygienic production environment for cows in air quality and acoustic environment.