ACFoam-II HCFC Free "Green" Polyiso Specification

Similar documents
ACFoam -III Specifications Atlas Roofing

ACFoam Supreme Specifications Atlas Roofing

ACFoam CrossVent RB Specifications Atlas Roofing

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

ATLAS ROOFING PRODUCT GUIDE. Polyiso Roof Insulation, SPECIALTY PRODUCTS

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

A. Thermal Conductivity: Thicknesses indicated are for thermal conductivity (k-value at 75 degrees F) specified for each material.

FASTENING PATTERN GUIDE CONNECTING FUNCTION WITH FACILITY

Firestone Polyiso Boards

Subject: NRCA MRCA Joint Technical Bulletin. Date: January 2008 NOT COMPROMISE.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

SECTION ELASTOMERIC MEMBRANE ROOFING

Tapered Insulation Systems

(Project Location) (your firm's name)

ROOFING INSTALLATION GUIDELINES

COMMERCIAL ROOFING PRODUCTS

C. Applicable building codes should always be checked prior to proposing the application to Mule-Hide or the building owner.

RECOMMENDED DESIGN SPECIFICATION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Short Form Guide Specification. Specifying Extruded Polystyrene Roof Insulation- STYROFOAM DECKMATE Plus Tapered

SECTION ROOF AND DECK INSULATION

SECTION LIGHTWEIGHT INSULATING CONCRETE

POLYISO Polyisocyanurate Roofing Insulation

SECTION PREPARATION FOR RE-ROOFING

Bridgeton Research Center Roof Replacement and Related Work December 4, 2000 DSR # C/D

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

COMMERCIAL BUILDING APPLICATIONS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

COMMERCIAL ROOFING PRODUCTS POLYISO ROOF INSULATION, SPECIALTY PRODUCTS & ACCESSORIES

MASTERFORMAT SPECIFICATION

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Design and Construction Standards SECTION MODIFIED BITUMEN ROOFING SYSTEM

SECTION THERMAL INSULATION

Thermoplastic Single Ply & Multi-Ply Roofing Systems

SECTION STRUCTURAL INSULATED PANELS

NAILABLE INSULATION GUIDE

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

SECTION CONCRETE TILE ROOFING. A. American Society for Testing and Materials (ASTM):

FOAMULAR Commercial Roofing

SPECIFYING EXTRUDED POLYSTYRENE FOR PROTECTED MEMBRANE ROOFING SYSTEM (IRMA)- PMR Short Form Guide Specification

Moisture Sorption of Building Materials

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Thermasheath-XP. Insulation for Exposed Use

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

SECTION CONCRETE TILE ROOFING Carpentry Flashing and Sheet Metal. A. American Society for Testing and Materials (ASTM):

Lightweight Insulating Concrete Roof Decks

Master Specification WALLTITE Eco v.3 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

Section Property Standard Year Wind FM Physical Properties ASTM D

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Master Specification WALLTITE ECO v.2 by BASF Canada Inc. Section SPRAY POLYURETHANE FOAM INSULATION Page 1

OREGON CONVENTION CENTER CHILLER PLANT RE-DESIGN CD SET

PRODUCT CONTROL SECTION

Coal Tar Application and Design Considerations

PRODUCT CONTROL SECTION

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions

IB PVC Single-Ply 50. Technical Data Sheet

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

PRODUCT CONTROL SECTION

ADDENDUM. ADDENDUM NO. 2 October 19, 2017

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION MODIFIED BUILT-UP ASPHALT ROOFING PART 1 GENERAL

SECTION ADHERED SINGLE PLY MEMBRANE ROOFING

Mechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels

PRODUCT CONTROL SECTION

SSL-175. Specifications

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.

ROXUL Roof and Deck Insulation Section Master Guide Specification (MONOBOARD ) Page 1 April 2016

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

"Square" means a standard roofing measurement equal to 100 sq. ft. or 10 ft.-0" x 10 ft.-0".

DL-200. Specifications

Bid Opportunity Wilkes Reservoir North Cell Rehabilitation

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Closed-Cell Spray Foam Insulation. Performance in Residential and Commercial Buildings During Adverse Weather

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Moisture Sorption of Building Materials

Lamit Industries Nailbase Panels General Recommendations

PRODUCT CONTROL SECTION

Section 7 Waterproofing Roofing Standards

PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

ROCKWOOL Roof and Deck Insulation Section Master Guide Specification Page 1 Jan 2017

WARREN WWTF IMPROVEMENTS ADDENDUM NO. 6

PRODUCT CONTROL SECTION

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

G October 2018

SECTION CONCRETE ROOF TILE

1.1 SECTION INCLUDES Verify Scope, including identification of plies and type of coating.

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017

STUDY GUIDE. For the REGISTERED ROOF OBSERVER (RRO ) EXAM. Prepared By RRO Examination Development Task Force

Dated 3/28/14 SECTION SINGLE PLY ROOFING

Transcription:

ACFoam-II HCFC Free "Green" Polyiso Specification To help owners and specifiers, the following specification strategies are offered as they relate to product performance when including HCFC FREE Green Polyiso. First, it is recommended to adopt CSI s (The Construction Specification Institute www.csinet.org) Manual of Practice with Master Format and Page Format, which includes a 3 PART format, to generate industry accepted and proven specification formatting. Division 7 Thermal and Moisture Protection Section 07220 Roof and Deck Insulation PART 1 GENERAL 1.1 SECTION INCLUDES A. HCFC FREE Green Polyiso Rigid board type roof insulation(s) for thermal protection as part of roofing assemblies. B. Recover board HCFC FREE Green Polyiso roof insulation. C. Roofing crickets. 1.2 RELATED SECTIONS A. Section 05300 - Metal Deck. B. Section 06100 - Rough Carpentry: Wood roof blocking and nailers. 1.3 REFERENCES Specifier Note: (finish article heading number in sequential order) A. ASTM C 1289 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Insulation Board. B. ASTM D 312 - Standard Specification for Asphalt Used in Roofing. C. ASTM E 108 - Standard Test Methods for Fire Tests of Roof Coverings. D. ASTM E 119 - Standard Test Methods for Fire Tests of Building Constructions and Materials. E. FM 4450 - Approval Standard - Class I Insulated Steel Roof Decks. F. FM 4470 - Approval Standard - Class I Roof Covers. G. FS HH-I-1972/1 - Insulation Board, Thermal, Polyurethane or Polyisocyanurate, Faced with Aluminum Foil on Both Sides of the Foam. H. FS HH-I-1972/2 - Insulation Board, Thermal, Polyurethane or Polyisocyanurate, Faced with Asphalt/Organic Felt, Asphalt/Asbestos Felt, or Asphalt/Glass Fiber Felt on Both Sides of the Foam. I. FS HH-I-1972/3 - Insulation Board, Thermal, Polyurethane or Polyisocyanurate, Faced with Perlite Insulation Board on One Side and Asphalt/Organic Felt or Asphalt/Glass Fiber Felt on the Other. Specifiers Note: The above mentioned FS references are no longer applicable but may still be in some house

master specs it is recommended to remove these J. LTTR Long Term Thermal Resistance, using techniques from CAN/ULC S770 based on ASTM C1303 K. UL 263 - Fire Tests of Building Construction and Materials. L. UL 790 - Tests for Fire Resistance of Roof Covering Materials. M. UL 1256 - Fire Test of Roof Deck Constructions. N. ASTM E 2114-01 Standard Terminology for Sustainability Relative to the Performance of Buildings O. ASTM 2129 01 Standard Practice for Data Collection for Sustainability Assessment of Building Product 1.4 DEFINITIONS Specifier Note: Define unusual terms not explained in the Contract Documents but are used in unique ways not included in standard references. This article is rarely used BUT these are new terms as of 2002/2003 A. HCFC FREE Green Polyiso Roof Board Insulation is defined as environmentally friendly, with Zero Global Warming, Zero Ozone Depletion (ODP) as in compliance with the US EPA requirements of January 1, 2003 requirement to eliminate production of HCFC 141b. B. LTTR (Long Term Thermal Resistance) is defined as using techniques from ASTM C1303, CAN/ULC S770 predicting a foam s R-Value that has been shown to be equivalent to the average performance of a permeably faced foam insulation product over 15 years. In Canada this method is used as the Design R- Value. This applies to ALL foam insulation products with blowing agents other than air, such as Polyiso, Green Polyiso, extruded polystyrene and polyurethane. The new method is based on consensus standards in the US and Canada. PIMA has reported this method as providing a better understanding of the thermal performance of foam. 1.5 SUBMITTALS A. Submit under provisions of Section 01300 and 01600. B. Product Data: 1. Manufacturer s HCFC FREE Green Polyiso specifications 2. Installation instructions for HCFC FREE Green Polyiso insulation board and fasteners 3. Product Data as per ASTM 2129 01 Standard for Data Collection for Sustainability Assessment of Building Products C. Samples: 1. Submit 6 by 6 inch (152 by 152 mm) samples of each board type required. 2. Submit samples of each fastener type required. D. Shop Drawings: Roof plan showing layout of boards, and fastening patterns, and ventilation and roof edge details. E. Certificates: System Manufacturer s or insulation manufacturer s certification that HCFC FREE Green Polyiso materials meet Zero ODP (Ozone Depletion Potential) and Zero GWP (Global Warming Potential)

specification requirements. F. Thermal Warranty: Submit sample warranty indicating conditions and limitations. 1.6 QUALITY ASSURANCE A. HCFC FREE Green Polyiso Manufacturer Qualifications: 1. Show evidence of ability to manufacturer products specified with sufficient manufacturing facilities. a. List dates of HCFC FREE Green Polyiso plant conversion and/or full production operation b. List HCFC chemistry alternative/replacement. 2. Provide past project HCFC FREE Green Polyiso installation performance histories Specifier Note: A recommended option in evidence of ability to manufacture HCFC FREE Green products includes request for 5 years of past project installation performance history and a billion sq. ft. of installed product. B. Regulatory Requirements: *** VERIFY WITH APPLICABLE GOVERNING AGENCIES THE SPECIFIC STANDARDS TO BE COMPLIED WITH AND RETAIN, DELETE OR ADD ADDITIONAL REQUIREMENTS BELOW. *** 1. American Society for Testing and Materials (ASTM). 2. Federal Specifications (FS). Specifiers Note: The above mentioned FS references are no longer applicable but may still be in some house master specs it is recommended to remove these 3. Factory Mutual (FM). 4. Underwriters Laboratories Inc. (UL) Classification. 5. Metro-Dade County, Florida Product Control. 6. California State Insulation Quality Standards and Title 25 Foam Flammability Criteria. 7. IBC, BOCA, ICBO and SBCCI Sections on Foam Insulation. 8. Canadian Compliance: CAN/ULC, CGSB. 1.7 DELIVERY, STORAGE AND HANDLING A. Comply with general requirements specified in Section 01650. B. Deliver insulation in packages labeled with material name, thermal value and product code. C. When stored outdoors, stack insulation on pallets above ground or roof deck and cover with tarpaulin or other suitable waterproof coverings. Slit or remove manufacturer s packaging before covering with waterproof covering. 1.8 PROJECT CONDITIONS

A. Comply with insurance underwriter s requirements applicable for products of this Section. B. Do not install insulation on roof deck when water of any type is present. Do not apply roofing materials when substrate is damp or wet. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturers: Atlas Roofing Corporation, Atlas Roofing Corporation, 2000 RiverEdge Parkway, Suite 800, Atlanta, GA 30328 Ph. (770) 933-4478 Fax (770) 952-3170 B. Local Representative(s): Atlas Roofing Corporation,. *** INSERT NAME, ADDRESS AND PHONE NUMBER. *** C. Requests for substitutions will be considered in accordance with provisions of Section 01600. D. Substitutions: Not permitted. E. Provide all HCFC FREE Green Polyiso roof board insulation from a single manufacturer. 2.2 MATERIALS A. HCFC FREE Green Polyiso Roof Board Insulation: Provide products that comply with the following: 1. ASTM standards specified. 2. Factory Mutual (FM) approvals specified. 3. Underwriters Laboratories Inc. (UL) classifications specified. 4. Metro-Dade County, Florida Product Control. 5. California State Insulation Quality Standards and Title 25 Foam Flammability Criteria. 6. BOCA National Building Code Sections on Foam Insulation 7. ICBO Uniform Building Code Sections on Foam Insulation. 8. SBCCI Standard Building Code Sections on Foam Insulation. 9. Canadian Compliance: CAN/ULC, CGSB, and CCMC. 10. Montreal Protocol requirements to eliminate HCFC 141b from production by January 1, 2003 B. ACFoam-II: Closed-cell HCFC FREE Green polyisocyanurate foam core manufactured using [HCFC] [ACUltra Hydrocarbon] blowing agent and integrally laminated to heavy non- asphaltic fiber-reinforced felt facers; FM [1-60] [1-90] wind uplift classification; compressive strength - [20 psi] [25 psi]. * Federal Specification HH-I-1972/GEN and HH-I-1972/2, Class 1. This federal specification has been

cancelled. * ASTM C 1289, Type II, Class 1. * Metro-Dade County, Florida Product Control No. 00-0208.04. * NYC MEA #107-01-M. * California State Insulation Quality Standards and Title 25 Foam Flammability Criteria (License #TC 1231). * IBC, BOCA, ICBO and SBCCI Sections on Foam Insulation. * CCMC No. 12464-L. * Meets CAN/CGSB-51.26-M86. * Meets CAN/ULC-S704. FM Standard 4450/4470 Approval ACFoam-II is approved for Class 1 insulated steel, wood, concrete and gypsum roof deck construction for both 1-60 and 1-90 Windstorm Classifications (may be mopped or mechanically fastened to concrete roof deck). Refer to FM Approval Guide for details on specific systems. UL Standard 1256 Classification Insulated metal deck construction assemblies - Construction #120 and #123. UL Standard 790 (ASTM E 108) Classification Class A with most roof membrane systems. See UL Roofing Materials & Systems Directory. UL Standard 263 Fire Resistance Classification (ASTM E 119) Some classifications for fire resistance are P225, P230, P259, P508, P510, P514, P519, P701, P710, P713, P717, P718, P719, P720, P722, P723, P724, P725, P727, P728, P729, P730, P732, P801, P814, P815, P818, P819, and P828. See UL Fire Resistance Directory for updated listings. UL Standard 1897 Uplift Resistance 120 PSF, 150 PSF, 165 PSF, 245 PSF. UL Certified for Canada UL of Canada Insulated Roof Deck Assemblies - Construction #C34. Meets CAN/ULC-S126-M86, CAN/ULC-S101-M89, CAN/ULC-S107-M87 *** INSERT REQUIRED "R" VALUE BELOW. *** C. LTTR - Insulation "R" Value:* Long-term thermal resistance values of the foam were determined in accordance with CAN/ULC-S770. All test samples were third-party selected and tested by an accredited materials testing laboratory. D. Related Materials: 1. Fasteners: Factory Mutual approved. 2. Base Ply: As recommended by membrane manufacturer. 3. Fasteners: For Nail Base and Vented-R: Atlas Nail Base Fasteners. 4. Asphalt Bitumen: Comply with ASTM D 312, Type III (steep) or Type IV. USE ONLY ON APPROVED BOARD INSULATION TYPES. a. Provide with labels indicating flash point, softening point, finished blowing temperature, and equiviscous temperature.

PART 3 - EXECUTION 3.1 EXAMINATION A. Examine roof deck for suitability to receive insulation. Verify that substrate is dry, clean and free of foreign material that will damage insulation or impede installation. B. Verify that roof drains, scuppers, roof curbs, nailers, equipment supports, vents and other roof accessories are secured properly and installed in conformance with Contract Drawings and submittals. C. Verify that deck is structurally sound to support installers, materials and equipment without damaging or deforming work. 1. Start of installation indicates installer accepts conditions of existing deck surfaces. 3.2 APPLICATION / INSTALLATION *** VERIFY NEED FOR A VAPOR RETARDER WITH DESIGNER IN ACCORDANCE WITH CURRENT VAPOR RETARDER THEORY AND ENGINEERING FORMULAS. WHEN REQUIRED, INSERT INSTALLATION REQUIREMENTS OF VAPOR RETARDER MANUFACTURER. *** A. Install specified insulation using approved [mechanical fasteners] [hot asphalt] [adhesives] in accordance with manufacturer s latest written instructions and as required by governing codes and Owner s insurance carrier. B. Install with end joints staggered to avoid having insulation joints coinciding with joints in deck. In multilayer installations, stagger joints in top and bottom layers. *** NOTE TO SPECIFIER: ATLAS SUPPORTS NRCA AND OTHER INDUSTRY AUTHORITIES IN RECOMMENDING MULTI-LAYER INSULATION APPLICATIONS. (SEE TECHNICAL BULLETIN #00-01) *** 3.3 CLEANING / PROTECTION A. Remove trash and construction debris from insulation surface prior to application of roofing membrane. B. Do not leave installed insulation exposed to weather. Cover and waterproof with completed roof system immediately after installation. 1. Temporarily seal exposed insulation edges at the end of each day. 2. Remove and replace installed insulation that has become wet or damaged with new insulation. C. Protect installed insulation and roof cover from traffic by use of protective covering materials during and after installation