PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Similar documents
QuantStudio 3 and QuantStudio 5 Real-Time PCR Systems. Connect to your data anytime, anywhere

qpcr for who you are Applied Biosystems QuantStudio real-time PCR and digital PCR systems

Same TaqMan Assay quality, new format

HID Real-Time PCR Analysis Software v1.3

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Innovative. Intelligent. Intuitive.

DEVELOP YOUR LAB, YOUR WAY. The FLOW Solution: Expand your potential today

PRODUCT BROCHURE PCR Systems. Veriti Thermal Cycler The Power of MORE

HID Real-Time PCR Analysis Software v1.1

StepOne and StepOnePlus Real-Time PCR Systems

PERFORMANCE MADE EASY REAL-TIME PCR

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

QuantStudio Dx Real-Time PCR Instrument

Protocol for Creating Custom RT and Preamplification Pools using TaqMan MicroRNA Assays

Touchscreen (standalone capabilities, PIN-protected user accounts, and dye calibration/rnasep functionality)

TaqMan Protein Assays

TaqPath ProAmp Master Mixes

For outstanding performance in real-time PCR

ReadMe Software v2.0.1 For Applied Biosystems 7500 and 7500 Fast Real-Time PCR Systems

cobas s 201 system for NAT Donor Screening One Vision. Many Possibilities.

StepOne and StepOnePlus Real-Time PCR Systems

quantitate host cell DNA with high sensitivity and throughput resdnaseq Host Cell DNA Quantitation Systems: CHO, E.

Fully Automated Library Quantification for Illumina Sequencing on the NGS STAR

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

Applied Biosystems TaqMan Array Microfluidic Cards

StepOne and StepOnePlus Real-Time PCR Systems. Remarkably Simple Systems. Simply Remarkable Results.

AccuSEQ v2.1 Real-Time PCR Detection and Analysis Software

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

Single-Cell. Defy the Law of Averages

Exicycler 96. Real-Time Quantitative Thermal Block Ver. 1. 2(EN)

DEFY THE LAW OF AVERAGES. Single-Cell Targeted Gene Expression Analysis

LightCycler 480 Instrument Quick Guide

Applied Biosystems 7500 Fast Real-Time PCR System

MYGO PRO vs LIGHTCYCLER NANO

High-throughput profiling, confirmation, and screening in a mid-density format. The QuantStudio 12K Flex Real-Time PCR System

FluentControl TM TAKE CONTROL OF TECAN S MOST POWERFUL LIQUID HANDLING WORKSTATIONS

BR-9516B. SNP genotyping analysis for medium to ultra-high throughput. GENOMELAB TM SNPSTREAM GENOTYPING SERIES

ENVAIR lab Real-Time PCR

APPLICATION NOTE. The QuantStudio 12K Flex Real-Time PCR System

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

Fluent for Genomic Workflows INCREASED PRODUCTIVITY POWERED BY TECAN S AUTOMATION WORKSTATION

TaqMan Protein Assays Probe Development

AccuSEQ Real-Time PCR Detection Software

MAGPIX. Multiplexed Genomic, and Proteomic Biomarker Analysis

Simple, Complete Workflows for Gene Expression Analysis without RNA Purification

Use the AccuSEQ Software v2.0 Mycoplasma SEQ module

Rapid, Accurate and Flexible DNA Quantitation Using the QuantiFluor dsdna System on the MANTIS Liquid Handler

AriaMx REAL-TIME PCR SYSTEM

Real-Time PCR. Real-Time PCR meets Automation qtower 3 auto

Impact of Standardizing on Traceable QC for Volume Transfers Artel

GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS. Genomics Solutions Portfolio

Detection of FactorV Leiden (R506Q)

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS. Genomics Solutions Portfolio

AriaMx. Real-Time PCR System

NovoCyte Flow Cytometer

SPEED AGILITY PRECISION. BETTER SYSTEMS. BRILLIANT RESULTS. Agilent Real-Time PCR Solutions

Redefining Automation

User Bulletin. ABI PRISM 7000 Sequence Detection System DRAFT. SUBJECT: Software Upgrade from Version 1.0 to 1.1. Version 1.

Reliable. answers, significant savings. Applied Biosystems QuantStudio 5 Real-Time PCR System for Human Identification

Fluent Laboratory Automation Workstation for cell-based assays THE SIMPLE WAY TO TAKE THE COMPLEXITY OUT OF CELL BIOLOGY RESEARCH

Completing the performance picture.

BR-16994A BIOMEK 4000 LABORATORY AUTOMATION WORKSTATION INTUITIVE SOFTWARE. MAXIMUM VERSATILITY.

SpectraMax Paradigm Microplate Reader

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

A Bibby Scientific Company. Alpha Cycler. Endpoint PCR range and Alpha Track Reporting. Speed. Confidence. Value. Sensitivity. Performance.

resdnaseq Quantitative DNA Kits

Perform an HRM Methylation Study

SUBJECT: System Software Patch Provides Support for Fast SYBR Green Master Mix and RNA-to-C T

Dynex DS2 2-Plate ELISA Processing System. Compact Easy to Use Innovative A Perfect Combination.

The first and only fully-integrated microarray instrument for hands-free array processing

Instrument specifications Technology Software Host interfaces Printer interfaces Data Station Physical dimensions Weight Certifications

Alpha Cyclers. Endpoint PCR range and Alpha Track Reporting. Speed. Confidence. Value. Sensitivity. Performance.

ARM-D Kits Data Acquisition and Analysis Guide. Real-Time PCR Platform: Applied Biosystems QuantStudio 7 Flex Real-Time PCR System

Access. Access Laboratory Workstation BROCHURE READY-TO-GO ROBOTIC SYSTEMS FOR ECHO LIQUID HANDLERS. Version 2.1 MAY 2017 LABCYTE INC.

Redefining Automation

Surely Better Target Enrichment from Sample to Sequencer

TAKE YOUR NEXT STEP WITH CONFIDENCE

Guide to running KASP genotyping on the ABI 7500 instrument

Quantitative PCR Systems

Multiplex RT for TaqMan Array Human MicroRNA Panel

HiSeqTM 2000 Sequencing System

Automation of Lexogen s QuantSeq 3 mrna-seq Library Prep Kits on the Biomek FX p NGS Workstation

SEQUENCING FROM SAMPLE TO SEQUENCE READY

Applied Biosystem Prism 6700 Automated Nucleic Acid Workstation

SCIEX OS Software One Touch Productivity

Changing the world of laboratory developed testing

3 r. ProbeSure Genotyping Master Mix User Guide. Cbioscience. Page 1 ProbeSure User Guide v1.4

QuantiNova proven compatibility with various real-time cyclers in gene expression analysis

Embrace the Future of Electrophoresis

CELL HEALTH. reliable cell viability data. instant time savings. PrestoBlue Cell Viability Reagent

High-Throughput Glycan Screening to Remove Biopharmaceutical Development Bottlenecks

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Simplify your pathogen testing. Amplify your confidence.

Dynex DSX 4-Plate ELISA Processing System. Modular Flexible Reliable A Perfect Combination.

SmartSystem. Specifications. sensitive real-time PCR system in the world. Physical dimensions. Optics. Power requirements

Thermo Scientific ARM Automation Platform

solid S Y S T E M s e q u e n c i n g See the Difference Discover the Quality Genome

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

TaqMan Residual DNA Detection Kit Chinese Hamster Ovary v2 Protocol

Transcription:

PCR SYSTEMS a new era in high-productivity qpcr Applied Biosystems ViiA 7 Real-Time PCR System

a new era in high-productivity qpcr The ViiA 7 Real-Time PCR System delivers the proven reliability, sensitivity, and accuracy you expect from Applied Biosystems, with new features designed for high-productivity qpcr. Building on the gold-standard design elements of six generations of real-time PCR systems, the ViiA 7 Real-Time PCR System makes it easier to get the high-quality results you need. Accomplish more, faster. Run hundreds of qpcr reactions simultaneously on the ViiA 7 System with TaqMan Array Micro Fluidic Cards. The fully integrated workflow speeds your time-to-results. Skip the learning curve. The ViiA 7 System s intuitive software, easy touch screen setup, automation integration, and effortless block exchange are designed to let you get started right away. Get results you can trust: well to well, run to run, and instrument to instrument. Enhanced fluorescence detection with the OptiFlex System offers six excitation and six emission filters for more multiplexing flexibility, and higher resolution for more accurate data. Get the flexibility you need. Easily interchangeable thermal cycling block formats let you select the format that s right for your project. You can choose from standard or Fast 96- and 384-well formats, as well as a novel 384-well TaqMan Array block.

ViiA 7 [vee-uh sev-uhn] high-productivity qpcr instrument 1. A new, 7th-generation real-time PCR system that paves the way for high-productivity qpcr through flexibility, performance, integrated TaqMan Assay content, and the most advanced set of features available.

productivity. integration. performance. The ViiA 7 Real-Time PCR System combines all of the qpcr features you want in a single high-performance instrument, so that you can optimize your research productivity. With a simplified workflow, intuitive software, touch screen interface, and one-button protocols for error minimization, the ViiA 7 System offers exceptional reproducibility with minimal well-to-well and instrument-to-instrument variation. Full compatibility with any standard or fast-cycling 384- or 96-well plates and TaqMan Array Micro Fluidic Cards and Reagents makes highproductivity real-time PCR accessible to labs of any size. Front access allows easy block change. TaqMan Array Micro Fluidic Card. Streamlines reaction setup, does not require liquidhandling robotics, and provides standardization when screening selected panels of genes.

Productivity High-performance features for maximum productivity Ideal for performing medium- to highthroughput real-time PCR, the ViiA 7 System enhances your lab s productivity. Quick block changes: Front access makes it easy to change thermal cycling block formats without having to move attached peripherals such as robots or computers. Easy touch screen interface: Instrument touch screen provides one-touch protocols for fast and easy assay setup for a broad range of applications. Automation compatibility: Integrated with the Applied Biosystems Twister II Robot, the ViiA 7 System will allow you to maximize productivity for auto mated environments. Peace of mind: Data recovery capability for 100+ runs. Integration Fully compatible with TaqMan Array Micro Fluidic Cards Applied Biosystems TaqMan Assays are the gold standard in qpcr analysis, providing high sensitivity, high specificity, and a broad dynamic range. TaqMan Array ready: Hundreds of customizable and predefined TaqMan Array Micro Fluidic Cards are available, containing preloaded TaqMan Gene Expression or MicroRNA Assays in an easy-to-use format. You can analyze 1 8 samples in parallel using your choice of 12 384 TaqMan Assays. 384-well throughput without robotics: With TaqMan Array Micro Fluidic Cards, there s no need for liquid-handling robotics or complex pipetting to load; simply add your sample and master mix and run on the ViiA 7 System. Compatible with the full range of TaqMan Assays: The ViiA 7 System is optimized to enable clear, clean data for all TaqMan Assays, including MicroRNA Assays, Protein Assays, Long Non-coding RNA Assays, and Pri-miRNA Assays. Performance New OptiFlex System for unsurpassed accuracy The ViiA 7 System features the new OptiFlex System, which provides enhanced fluorescence detection enabling accurate and sensitive data analysis. Better accuracy: High-resolution detection system for more accurate reads with TaqMan Array Micro Fluidic Cards, 384-well plates, and 96-well plates. Maximum multiplexing: Six decoupled excitation and emission filter channels for the greatest number of dye combinations and maximum multiplexing capabilities. Flexible data collection: Multiple ramp method detection formats provide more flexibility for collecting data during a ramp stage. Precise quantification: Detect changes as small as 1.5-fold in target quantities in singleplex reactions. 10 1 ΔRn 0.1 0.01 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Cycle Real-time reproducibility. This plot shows results from amplification of 18S target DNA in 10-fold dilutions starting at 25,000 copies, using the 384-well block. The data show highly reproducible results over 9 logs of input template amount, illustrating the broad linear dynamic range of the system. The ViiA 7 System is fully integrated with the Applied Biosystems Twister II Robot to enable high-productivity qpcr in automated environments.

ViiA 7 Software Intuitive, easy-to-use software for maximum productivity Intuitive interface and innovative design User-friendly: Easily identifiable icons guide you through the workflow seamlessly to set up runs and analyze experiments. The graphical interface makes it easy to edit the PCR thermal cycling conditions. The ViiA 7 remembers your favorites: With the new ReadiApp feature, you can quickly select default protocols for standard applications. Convenient walk-away operation Enjoy the freedom of operating the ViiA 7 System from any networked computer. Full remote control of up to four instruments: With the ViiA 7 Software Instrument Console, you can review run statistics and remotely control up to four instruments or experiments in real time from your desktop computer. You can also receive email notifications to keep you informed of run and instrument status when you are not in the lab. Status monitoring of up to 15 instruments: Up to 15 instruments can be networked for monitoring basic instrument status, so that you always know which instruments are in use and which are available for the next experiment. Expandable software architecture Optional add-ons are available to upgrade features to existing software. 21 CFR Part 11 compliance: The optional SAE module assists with Security, Auditing, and Electronic signature of records for full data traceability. Enhanced high-resolution melt (HRM): Using the built-in MeltDoctor protocols and calibrations, you can spend less time optimizing the run and more time customizing your results. Define the number of variants you want to see by quickly changing analysis settings. Improved data analysis The ViiA 7 Software offers innovative approaches to analyze your data. Easy management of large data sets: The embedded gene expression (RQ) study application is designed to analyze 100+ runs, while heat maps and scatter plots provide quick checks on data quality. Real-time control for genotyping cluster analysis: In genotyping experiments, you can optimize your genotyping run times using a real-time PCR progress monitor to determine the ideal cycle for cluster analysis. Fully compatible with high-throughput environments High-throughput experiment setup: Create multiple experiment files simultaneously with the push of a single button. You can import your plate setup files from other Applied Biosystems real-time systems to facilitate easy experiment setup. Easy, automated data export: Set up experiment templates with predefined export preferences and have the ViiA 7 Software autoexport to your desired file directory. Open API: Open application program interfaces (API) allow integration with third-party systems such as LIMS (laboratory integration management systems) or custom automated platforms.

2.2 Homozygous Allele 1/Allele 1 Heterozygous Allele 1/Allele 2 Homozygous Allele 2/Allele 2 Undetermined 1.7 Allele 2 1.2 0.7 0.2 0.3 0.8 1.3 Allele 1 1.8 2.3 Allelic discrimination plot with traces using real-time PCR data. Cluster plot of 94 gdna samples and 2 no-template controls (NTCs) genotyped using TaqMan SNP Genotyping Assay C_245448_10 with both PCR and allelic discrimination performed on the Applied Biosystems ViiA 7 Real-Time PCR System. The novel use of real-time PCR data to plot SNP cluster progress aids in calling ambiguous samples and reducing run times by displaying the optimal number of cycles necessary for maximum cluster separation. Additional analysis plots are available for quality control. For example, heat maps are available to assess the correlation between samples in gene expression experiments. With the ViiA 7 System, up to four instruments can be remotely controlled and precisely monitored in real time. You can even review detailed run statistics and other vital information remotely and receive status notifications by email. Up to 15 instruments can be networked to provide basic instrument status information from any networked computer. Intuitive interface and innovative design. Thanks to an intuitive interface and innovative design, with ViiA 7 Software you can start a run in less than five clicks with the QuickStart feature, access optimized application protocols using the ReadiApp feature, and create studies directly from the software home screen.

the complete qpcr solution to advance your research Our mission is to continually support your path to discovery. The ViiA 7 Real- Time PCR System embodies our commitment to providing everything you need for easier, more productive qpcr experiments as part of a complete solution from sample to results. With full integration, everything works together instruments, software, chemistries, and ready-to-use assays to enable the consistent, reliable results you need to advance your research.

In addition to instrumentation, software, and consumables, the ViiA 7 System includes: Professional installation Worldwide application and technical support For more information about the ViiA 7 Real-Time PCR System or any of our qpcr products, contact your Applied Biosystems representative or visit www.appliedbiosystems.com/viia7

Specifications Block change design Temperature uniformity Run time Demonstrated sensitivity Dynamic range Supported applications Resolution Supported blocks and volume Excitation/detection wavelengths Block change from front of instrument in less than 1 min; no secondary tools required ±0.5 C, within 30 sec of reaching temperature set point ~35 min for 384-well, ~30 min for 0.2 ml 96-well and 0.1 ml Fast 96-well (using Applied Biosystems Fast Master Mix) Down to 1 copy Up to 9 logs of linear dynamic range Standard curve, Comparative C t, Genotyping, Presence/Absence, HRM, Melt curve Detect changes as little as 1.5-fold in target quantities in singleplex reaction 96-well standard (10 100 µl reactions) 96-well Fast (10 30 µl reactions) 384-well (5 20 µl reactions) TaqMan Array Micro Fluidic Cards (~1 µl reactions) 6 excitation (450 670 nm) 6 emission (500 720 nm) 21 CFR p11 enablement Security and auditing features for instrument data Power Automation Remote monitoring Remote notification Data export format Dimension (W x D x H) Weight 100 240 V, ~50/60 Hz Includes plate-loading arm w/ barcode (sales, service, and support provided by Life Technologies) Ability to monitor 15 instruments at a time; optional Smart Monitoring Service for remote instrument diagnostic monitoring by Life Technologies Emails user when run is started, stopped, or aborted Fully configurable by user 53.3 cm (21 in) x 63.5 cm (25 in) x 64.5 cm (25.4 in) 66.9 kg (148 lb) Ordering information Instrument systems P/N Applied Biosystems ViiA 7 Real-Time PCR System with 384-Well Block 4453536 Applied Biosystems ViiA 7 Real-Time PCR System with TaqMan Array Block 4453537 Applied Biosystems ViiA 7 Real-Time PCR System with 96-Well Fast Block 4453535 Applied Biosystems ViiA 7 Real-Time PCR System with 96-Well Block 4453534 Accessories ViiA 7 System Automation Accessory Robot (100 240 V) 4453551 384-Well Block Upgrade Kit 4453545 TaqMan Array Upgrade Kit 4453546 96-Well Fast Block Upgrade Kit 4453544 96-Well Block Upgrade Kit 4453543 Services 1-Year Extended Warranty, ViiA 7 System ZG61SCVIIA7 Software add-ons ViiA 7 Software HRM Module 4453724 ViiA 7 Software 21 CFR Part 11 Module 4453723 Life Technologies offers a breadth of products DNA RNA protein cell culture instruments For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. 2011 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. TaqMan is a registered trademark of Roche Molecular Systems, Inc. CO16738 0211 Headquarters 5791 Van Allen Way Carlsbad, CA 92008 USA Phone +1.760.603.7200 Toll Free in the USA 800.955.6288 www.lifetechnologies.com