LARGE-SIZE FACADE ELEMENTS OF TEXTILE REINFORCED CONCRETE

Similar documents
Analysis and experimental studies of building glass facade

Application of Tensioned CFRP Strip Method to an Existing Bridge

Bond efficiency factor at different textile geometries reinforced concrete beams

PRESTRESSED CONCRETE PLATES WITH HIGH STRENGTH FABRIC

Schöck Isokorb Type CM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

SECTION ULTRA HIGH PERFORMANCE CONCRETE (UHPC) PANELS

TECHNOLOGY FOR CONCRETE SHELLS FABRICATION REINFORCED BY GLASS FIBERS

BEARING BEHAVIOR OF IMPREGNATED TEXTILE REINFORCEMENT

PC Beam Shoe. Corbel system to support beams. Technical Manual. Version: DK 4/2012 Design standard: DS EN Eurocodes + NA (Denmark)

Council on Tall Buildings

SECTION ARCHITECTURAL PRECAST CONCRETE. C. Section Joint Sealers: Perimeter joints with sealant and backing.

Masonry and Cold-Formed Steel Requirements

Field and Laboratory Performance of FRP Bridge Panels

NONLINEAR ANALYSIS OF TEXTILE REINFORCED CONCRETE SHELLS USING AN ANISOTROPIC, DAMAGED-BASED MATERIAL MODEL

Schöck Isokorb type KS

CLADDING SYSTEM CLADDING PANELS.

Development of New PSC Box Girder Bridge with Concrete-filled FRP Struts

(1) (1) (1) P, Ali Shams P. Abstract. fine-grained. textile

TECHNICAL MANUAL. PC Beam Shoe. Hidden Beam Shoe for Corbel System

RESTORATION OF THE HISTORICAL CONCRETE-GLASS WINDOWS OF THE TOWN-HALL IN AACHEN

European Technical Assessment. ETA-09/0143 of 8 October English translation prepared by DIBt - Original version in German language.

General Design Approval

Manufacturer of glass reinforced concrete products

Characterization and Testing of Fiber Reinforced Concrete (American Standards)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

INVESTIGATION OF CURING PERIOD OF CEMENTITIOUS ADHESIVE AND PERFORMANCE OF RUST PREVENTION

Staron Exterior Wall Cladding SN

Schöck Isokorb Type CV

BEHAVIOUR AND DESIGN OF ANCHORS FOR LIFTING AND HANDLING IN PRECAST CONCRETE ELEMENTS

Level 6 Graduate Diploma in Engineering Structural analysis

Research on Weight Reduction of PC Composite Members Using Ultra High Strength Fiber Reinforced Cementitious Composites (UFC)

Just Makes Cents... Per Watt. Compliance Report Composition L-Foot Kit State of California September 25th SOLARACK INC.

Façade claddings. Sandwich panel SPA, SPB W, SP2D W

Carbon Fibre Textile

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

RUUKKI FAÇADE SYSTEMS

STRUCTURAL GLASS FACADE ALL GLASS FINS & BEAMS

Structural Design of Pergola with Airfoil Louvers

Presentation in support of

DESIGN & AESTHETICS. The KEIL Anchor Facts. Appearance. Maintenance and Replacement

Basic types of bridge decks

Strength of Non-Prismatic Composite Self-Compacting Concrete Steel Girders

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

16. Design of Pipeline Structures.

RUUKKI FORMA DESIGN INSTRUCTION

ifix INSTALLATION MANUAL PV flat roof installation system Version

Strengthening of concrete members by means of carbon fiber reinforced polymers (CFRP)

Openings in Sandwich Elements

SUPERPLUS M8-M16. The undercut fixing system that does not require a special setting tool. FUNCTION BENEFITS

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

Oriented fibrous structures for concrete reinforcement

Ultra-High Performance Wall System Glass Fiber Reinforced Concrete

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

Design Manual Facade, riveted Panel fixed to T-Sections

Architectural Concrete with UHPC for façades and interior design-recent application in Germany

Part 4 MECHANICAL PROPERTIES

Sports center (Ciudad Real - Spain) - Arch. Javier Ramírez de Arellano Rayo

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

HARVEY MUDD COLLEGE TEACHING AND LEARNING CENTER SECTION Page 1 of 6 VOIDED CONCRETE SLAB

BIJL COMPOSITE PLANKS FOR NEW CONSTRUCTION AND UPGRADES

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

DOI: /IJMTER DQMWV 51

Armatherm Structural Thermal Bridging Solutions

DIVISION 20 GENERAL SECTIONS FOR PLUMBING, FIRE SUPPRESSION & HVAC SECTION VIBRATION ISOLATORS

STAAD.pro 2007 Design of Wind Turbine Foundations

Stofix Facade. The long-lasting and energy saving solution for renovation and new construction

Phenolic Exterior Wall Cladding

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES

Design and construction of Hechang Bridge, Quanzhou, China

The World s First RPC Road Bridge at Shepherds Gully Creek, NSW

THE PERFORMANCE OF CONCRETE GROUND FLOOR SLAB REINFORCEMENT TO CONTROL SHRINKAGE CRACKING. D H Chisholm 1

Timber-steel-hybrid beams for multi-storey buildings

mortarless Design Manual Part 3 (AS 3600:2009) Section 2 Page: DESIGN OF WALLS FOR AXIAL COMPRESSION USING SIMPLIFIED DESIGN METHOD

Concrete technology for a CONCRETE future. PLANTS & MACHINERY for the production of CONCRETE ELEMENTS

SPECIFICATION SECTION PART 1 GENERAL

Characteristics of KURALON TM (PVA fiber)

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Loading Tests of Thin-Walled Ferro-Cement Panels for Horizontal Slab Structures

STUDY ON THE FLEXURAL BEHAVIOUR OF CFRP-GRID REINFORCED CONCRETE ONE-WAY SLABS

National technical approval

fischer fixing compass Cracked concrete.

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

TECHNICAL MANUAL. HPKM Column Shoe Reliable Bolted Column Connections. Version: PEIKKO GROUP ACI-M 01/2017 Designed according to ACI 318M-11

9. VACUUM TANK 9. VACUUM TANK

EXPERIMENTAL STUDY ON LOAD CAPACITIES OF ISOLATED HEAVY-DUTY SCAFFOLDS USED IN CONSTRUCTION

EXPERIMENTAL STUDY ON CRACK-BRIDGING ABILITY OF ECC FOR REPAIR UNDER TRAIN LOADING

HunterDouglas NBK Ceramic TERRART [Large/Mid/Shingle/Light/Baguette) Terracotta Façade System

Series ESK / ESB. Cabinets in Modular Design. Manufacturing Program: ESK-20 ESK-40 ESK-80 ESB Sandwich construction 20 mm, 40 mm and 80 mm

Compression Test for Precast Encased Composite Columns with Corrugated Steel Tube

Schöck Isokorb Type CEQ

Double-curved Panels produced in a flexible Mould with selfcompacting Fibre Reinforced Concrete

VARIOUS TYPES OF SLABS

CURVED BEAM TEST BEHAVIOR OF 3D WOVEN COMPOSITES

DOUBLE-CURVED TEXTILE REINFORCED CONCRETE PANELS WITH TENSILE STRAIN--HARDENING CHARACTERISTICS

System DFF 21. Highly elastic rail fastening for conventional rail and metro the optimum single support point for slab track

TILT-UP DESIGN SOFTWARE VERIFICATION FOR LIGHTWEIGHT CONCRETE WALL BEHAVIOR DURING LIFTING

CE 479 CURTAIN WALL STRUCTURES. Guest Lecturer: Bruce Kaskel, SE, RA Principal Wiss, Janney, Elstner Associates, Inc.

Conergy SolarFamulus II

Transcription:

1st International Conference Textile Reinforced Concrete (ICTRC) 309 LARGE-SIZE FACADE ELEMENTS OF TEXTILE REINFORCED CONCRETE E. Engberts, Fydro B.V., the Netherlands ABSTRACT: This contribution describes an example for fair-faced concrete elements. However, applications of textile reinforced concrete in building industry are seldom up to now. In Germany one needs approval (single case or general) for using TRC in structural buildings. 1 INTRODUCTION In architecture, the renaissance of fair-faced concrete construction and the demand for light and filigree but nevertheless sustainable structures presently leads to an increased demand for thin-walled façade elements of textile reinforced concrete. Construction and building are described at the example of the object House Rheinlanddamm Dortmund which was erected in 2002/2003, see Fig. 1 and 2. 2 OBJECT The object House Rheinlanddamm is an office building with 6 complete stories and a building height of about 21 m which was erected applying a conventional steel reinforced concrete construction method. According to the design of the architecture firm, the building should get a rear-ventilated façade of large-size, textile reinforced glass fiber concrete elements. The company Fydro B.V. from the Netherlands was ordered to manufacture these elements with a size of up to 7 m². 3 FACADE ELEMENTS For the production of the textile reinforced façade elements, the purely mineral concrete matrix, developed by the manufacturer and used standardizedly, was applied which ensures an approved high durability of the textile reinforced concrete. In order to yield the necessary bearing strength, the 25 mm thick façade elements were reinforced with alkali-resistant (AR) glass fiber fabrics and with continuous AR endless rovings on both sides. Additionally, AR short fibers were introduced to increase the crack prevention. Due to the partly very large dimensions of the slabs of up to 2,100 x 3,500 mm a machine-production on a continuously operating equipment was no longer possible. Instead, the elements had to be manufactured in formworks as a single-part production. Nevertheless, to render the production widely efficient, the matrix was modified in that it practically featured the flowability of a selfcompacting concrete (SCC). To yield the finely structured surface stipulated by the architect, the production of the elements was made on an especially developed fleece inserted into the

310 ENGBERTS: Large-Size Façade Elements of Textile Reinforced Concrete formwork which, on the one hand, created the micro surface structure and by which, on the other hand, simultaneously a curing of the concrete was made. The color, a warm grey, defined by the architect, was tuned adding iron oxide pigments. For this purpose, numerous pre-tests had to be conducted in the laboratory. 4 FIXING AND CONSTRUCTION For the invisible fixing of the façade elements undercut anchors FZP 11 x 21 M6 of the Fischer company were used. Due to the necessary high precision the undercut bores and the insertion of the anchors were made in the production plant. Position and number of the anchors were adapted to the results of the static calculation. Owing to the thickness of the slabs and the resulting possible anchoring depth, the number of anchors depending on the respective high position of the element and its positioning in a normal-, edge- or corner area could be limited to an average of 4 to 5 pcs./m², thus reducing the assembly costs to a minimum. The assembly of the façade elements was made on a standardized aluminum substructure of U-brackets and extruded U-profiles and T-shaped suspension girders. The fixing of the U-brackets at the load carrying structure was made with MKT-anchors M10 as fixed point and with Fischer SXS 10 x 60 as moving point. The U-profiles slotted at the front and inserted into the brackets were fixed with stainless steel bolts. The façade elements with the factory mounted T-profiles were fitted into the U-profiles. To yield a restraint-free bearing, all bores in the T-profiles were made as slotted holes. 5 ASSEMBLY The 3,000 m² large façade was assembled in 2002/2003. Altogether more than 1,200 elements with dimensions ranging from 850 x 3,500 to 2,100 x 3,500 mm were assembled. Special hoisting devices had to be employed due to the slab thickness of 25 mm and a grammage of 50 kg/m², respectively, so that, on the one hand, the elements and the load bearing structure were not unduly stressed under assembly and, on the other hand, a problem-free fitting of the elements into the substructure was ensured, see Fig. 3 and 4. 6 STATICS AND MATERIAL CHARACTERISTICS As up to the present date, there are no standardized design procedures for glass fiber concretes and textile reinforced concretes, the static calculation of the elements was made applying the Finite Element Method on the basis of the previously determined material characteristics. In the calculation the following material properties of the textile reinforced concrete were taken as a basis: Proportional limit (LOP): > 7,5 MPa Flexural strength (MOR): > 12,0 MPa Young s modulus: 20.000 MPa Thermal dilatation: 1,5 x 10-5

1st International Conference Textile Reinforced Concrete (ICTRC) 311 From these test values, permissible design values were determined and defined for the decisive calculation values under consideration of the usual safety standards. The load bearing capacity of the undercut anchor, which is the decisive characteristic for the dimensioning, was restricted to about 0.52 kn because of the test results. By means of the permissive values, first the necessary standardized verifications of the flexural stresses and the anchoring strengths depending on the stiffness ratio between substructure and glass fiber concrete elements was made. The permissive deflections of the slabs were here limited to L/300 in the middle of the field and to L/200 at the cantilevers. In a complementary calculation, the failure case was simulated removing the most heavily loaded anchor from the calculation model in order to be able to prove that the calculatively remaining anchors are capable to absorb the arising forces and to conduct them into the substructure. Fig. 5 exemplarily demonstrate the bending moments mr and ms as well as the deformations for a slab with the dimensions length x width = 3,490 x 1,040 mm and a fixing by means of 8 anchors. 7 APPROVAL IN INDIVIDUAL CASE Due to the existing situation regarding the building laws and the still missing material and design standards for textile reinforced concrete an Approval in Individual Case according to the federal building regulations of North Rhine-Westphalia (LBO-NRW) was necessary. The basis for the grant of the Approval in Individual Case were the results of extensive tests of the construction, conducted by the Materials Testing Institute University of Stuttgart (MPA Stuttgart, Otto-Graf-Institute (FMPA)). Within the framework of these investigations the material characteristics as well as the total structure consisting of façade elements and the substructure were tested in a 1:1-test up to failure (Fig. 6). As expected the total structure failed in all building member tests due to exceeding the maximum anchor force, whereas the anchors always failed in the places expected. With reference to the calculative wind suction loads to be taken into account, safety distances of 6 compared to the failure load resulted from the building member tests. 8 OUTLOOK The completed project House Rheinlanddamm Dortmund showed that façades can be realized with large-size textile reinforced glass fiber concrete elements. In the meantime, the company Fydro B.V. has realized further projects in Mettmann and Arnheim, see Fig. 7 to 11. Still this year, façades of textile reinforced concrete will be erected in Frankfurt, Hamburg und Heidelberg where each façade is produced object-related and thus represents a unicum.

312 ENGBERTS: Large-Size Façade Elements of Textile Reinforced Concrete Fig. 1 Façade House Rheinlanddamm Fig. 2 Façade House Rheinlanddamm

1st International Conference Textile Reinforced Concrete (ICTRC) 313 Fig. 3 Façade House Rheinlanddamm Fig. 4 Façade of House Rheinlanddamm

314 ENGBERTS: Large-Size Façade Elements of Textile Reinforced Concrete Bending moment mr as a result of wind suction Bending moment ms as a result of wind suction Deformation of the elements as a result of wind suction Fig. 5 Results of a Finite Element calculation

1st International Conference Textile Reinforced Concrete (ICTRC) 315 Fig. 6 Façade element mounted into a façade testing facility

316 ENGBERTS: Large-Size Façade Elements of Textile Reinforced Concrete Fig. 7 Parking garage in Arnheim

1st International Conference Textile Reinforced Concrete (ICTRC) 317 Fig. 8 Parking garage in Arnheim Fig. 9 Parking garage in Arnheim

318 ENGBERTS: Large-Size Façade Elements of Textile Reinforced Concrete Fig. 10 Vocational College Mettmann Fig. 11 Vocational College Mettmann