Subcommittee 3, Connections August 15, 2012

Similar documents
COLD-FORMED STEEL BOLTED CONNECTIONS USING OVERSIZED AND SLOTTED HOLES WITHOUT WASHERS. Ke Xu. Thesis Prepared for the Degree of MASTER OF SCIENCE

IBC 2015 and Cold-Formed Steel Design Standards and Design Aids. Roger LaBoube Wei-Wen Yu Center for Cold-Formed Steel Structures

Testing of Bolted Cold- Formed Steel Connections in Bearing (With and Without Washers) RESEARCH REPORT RP01-4

Cold-formed Steel Bolted Connections Without Washers on Oversized Holes Shear and Bearing Failures in Sheets

(800) (562) A Subsidiary of the International Code Council

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

The following excerpt are pages from the North American Anchor Fastening Technical Guide, 2011.

HFX Adhesive Anchor Adhesive Anchoring Systems

ACCEPTANCE CRITERIA FOR EXPANSION BOLTS IN STRUCTURAL STEEL CONNECTIONS (BLIND-BOLTS) PREFACE

SECTION STRUCTURAL STEEL FRAMING

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

Power-Bolt+ Heavy Duty Sleeve Anchor

American Railway Engineering & Maintenance-of-Way Association Letter Ballot No

The American Institute

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

COLD-FORMED STEEL BOLTED CONNECTIONS WITHOUT WASHERS ON OVERSIZED AND SLOTTED HOLES. Ibraheem Sheerah, B.Sc., M.S. Thesis Prepared for the Degree of

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

AISI S E1 AISI STANDARD. Errata to North American Specification. for the Design of Cold-Formed. Steel Structural Members.

2016 AISC Standards. Specification for Structural Steel Buildings & Code of Standard Practice for Steel Buildings and Bridges.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

ASTM, SAE AND ISO GRADE MARKINGS AND MECHANICAL PROPERTIES FOR STEEL FASTENERS

STRUCTURAL STEEL FRAMING

Strong Bolt 2 Wedge Anchor for Cracked and Uncracked Concrete

Mechanical Requirements for Stainless Steel & Non-Ferrous Fasteners

Hilti, Inc South 122 nd East Avenue Tulsa, OK

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

PIP STE05121 Application of ASCE Anchorage Design for Petrochemical Facilities

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

REPORT HOLDER: MITEK USA, INC. EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: LINDAPTER

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS DIVISION: CONCRETE ANCHORS REPORT HOLDER: DEWALT

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: DEWALT

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

SECTION STRUCTURAL STEEL

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

TESTING APPLICATION STANDARD (TAS) 117(A)-95 TEST PROCEDURE FOR WITHDRAWAL RESISTANCE TESTING OF MECHANICAL FASTENERS USED IN ROOF SYSTEM ASSEMBLIES

DOMESTIC WEDGE ANCHOR

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

Draft. Not yet Approved. American Railway Engineering and Maintenance of Way Association Letter Ballot

SECTION ALTERNATING TREAD STEEL STAIRS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

Z4 PRODUCT CATALOG

Section 906. STRUCTURAL STEEL

The 2013 AISI Cold-Formed Steel Design Manual

*Corrected, April 2001

Proposed Revisions to Part 2, Sections 2.13 to Draft DEVELOPMENT AND SPLICES OF REINFORCEMENT SECTION 2.13 DEVELOPMENT REQUIREMENTS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

1 1 4" FRAMING SYSTEM

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: MMFX TECHNOLOGIES A COMMERCIAL METALS COMPANY

The parts of Report No.ESR-2089 marked by the asterisks are modified by the Los Angeles Building Department from this approval.

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: LNA SOLUTIONS A KEE SAFETY LOGISTIC LTD

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

twenty one steel construction: bolted & welded connections ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2015 lecture

SECTION ALTERNATING TREAD STEEL STAIRS

PROJECT SUBMITTAL. Power-Stud TM. Wedge Expansion Anchor PROJECT SUBMITTAL CONTENTS APPROVALS AND LISTINGS

PROFESSIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA. ~~A~~~!Etr~il'tt

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

ICC-ES Evaluation Report Issued November 1, 2011 This report is subject to renewal November 1, 2012.

Fire Sprinkler & pipe supports Cable Trays and Strut Suspended Lighting

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALED CONCRETE ANCHORS

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT

Composite Steel Deck - Slabs

Building Division Informational Handout

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

ESR-3574* Issued December 1, 2013 This report is subject to renewal August 1, 2014.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

Hilti, Inc South 122 nd East Avenue Tulsa, OK

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: SIMPSON STRONG-TIE COMPANY INC. EVALUATION SUBJECT:

LEGACY REPORT DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Hilti, Inc South 122 nd East Avenue Tulsa, OK

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

Transcription:

AISI Coittee on Specifications for the Design of Coittee/Subcoittee Ballot: CS11-345C Subcoittee 3, Connections August 15, 2012 SPECIFICATION E3 ed Connections The following design criteria and the requirements stipulated in Section E3a of Appendices A and B shall apply to bolted connections used for cold-formed steel structural members in which the thickness of the thinnest connected part is 3/16 (4.76 ) or less. For bolted connections in which the thickness of the thinnest connected part is greater than 3/16 (4.76 ), the specifications and standards stipulated in Section E3a of Appendix A or B shall apply. A,B s, nuts, and washers conforming to one of the following ASTM specifications shall be approved for use under this Specification: ASTM A194/A194M, Carbon and Alloy Steel Nuts for s for High-Pressure and High- Temperature Service ASTM A307 (Type A), Carbon Steel s and Studs, 60,000 PSI Tensile Strength ASTM A325, Structural s, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength ASTM A325M, High Strength s for Structural Steel Joints [Metric] ASTM A354 (Grade BD), Quenched and Tempered Alloy Steel s, Studs, and Other Externally Threaded Fasteners (for diameter of bolt smaller than 1/2 ) ASTM A449, Quenched and Tempered Steel s and Studs (for diameter of bolt smaller than 1/2 ) ASTM A490, Heat-Treated Steel Structural s, 150 ksi Minimum Tensile Strength ASTM A490M, High Strength Steel s, Classes 10.9 and 10.9.3, for Structural Steel Joints [Metric] ASTM A563, Carbon and Alloy Steel Nuts ASTM A563M, Carbon and Alloy Steel Nuts [Metric] ASTM F436, Hardened Steel Washers ASTM F436M, Hardened Steel Washers [Metric] ASTM F844, Washers, Steel, Plain (Flat), Unhardened for General Use ASTM F959, Compressible Washer-Type Direct Tension Indicators for Use with Structural Fasteners ASTM F959M, Compressible Washer-Type Direct Tension Indicators for Use with Structural Fasteners [Metric] When other than the above are used, drawings shall indicate clearly the type and size of fasteners to be employed and the nominal strength [resistance] assumed in design. s shall be installed and tightened to achieve satisfactory performance of the connections. The holes for bolts shall not exceed the sizes specified in Table E3a, except that larger holes are permitted to be used in column base details or structural systems connected to concrete walls. When the bolt hole deformation is considered in design in accordance with Eq. E3.3.2-1, the following restrictions shall be applied: (a) Standaroles shall be used in bolted connections, except that oversized and slotted

AISI Coittee on Specifications for the Design of Coittee/Subcoittee Ballot: CS11-345C Subcoittee 3, Connections August 15, 2012 holes shall be permitted to be used as approved by the designer; (b) The length of slotteoles shall be normal to the direction of the shear load; and (c) Washers or backup plates shall be installed over oversized or slotteoles in an outer ply unless suitable performance is demonstrated by tests in accordance with Chapter F. When the bolt hole deformation is not considered in design, oversizeoles and shortslotted holes are permitted. The holes for bolts shall not exceed the sizes specified in Table E3a. Maximum Size of s, in inches d * < 1 / 2 1 / 2 d + 1 / 32 d + 1 / 8 (d + 1 / 32 ) by (d + 1 / 4 ) ( ) by (d + 1 / 4 ) (d + 1 / 32 ) by (2 1 / 2 d) ( ) by (2 1 / 2 d) 9/16 by 7/8 * The alternative short-slotteole is only applicable for d/t=1/2 Maximum Size of s, in millimeters d * < 12.7 12.7 d + 0.8 d + 3.2 (d + 0.8) by (d + 6.4) () by (d + 6.4) * The alternative short-slotteole is only applicable for d/t=12.7 (d + 0.8) by (2 1 / 2 d) () by (2 1 / 2 d) 14.3 by 22.2 Slotted or oversizeoles shall be permitted to be used considered taken as standaroles when the hole occurs within the lap of lapped or nested Z-members, subject to the following restrictions: (1) 1/2 (12.7 )-diameter bolts only with or without washers or backup plates (2) Maximum slot size is 9/16 x 7/8 (14.3 x 22.2 ), slotted vertically (3) Maximum oversize hole is 5/8 (15.9 ) diameter (4) Minimum member thickness is 0.060 (1.52 ) nominal (5) Maximum member yield stress is 60 ksi (410 MPa, and 4220 kg/cm2) (6) Minimum lap length measured from center of frame to end of lap is 1.5 times the member depth.

AISI Coittee on Specifications for the Design of Coittee/Subcoittee Ballot: CS11-345C Subcoittee 3, Connections August 15, 2012 E3.1 Minimum Spacing The distance between the centers of fasteners shall not be less than 3d. In addition, the minimum distance between centers of bolt holes shall provide clearance for bolt heads, nuts, washers and the wrench. For oversized and slotteoles, the clear distance between the edges of two adjacent holes shall not be less than 2d. E3.2 Minimum Edge and End Distances The distance from the center of a fastener to the edge or end of any part shall not be less than 1.5d. For oversized and slotteoles, the distance between the edge of the hole and the edge or end of the member shall not be less than d. E3.3 Bearing The available bearing strength [factored resistance] of bolted connections shall be determined in accordance with Sections E3.3.1 and E3.3.2. For conditions not shown, the available bearing strength [factored resistance] of bolted connections shall be determined by tests. B E3.3.1 Bearing Strength [Resistance] Without Consideration of Deformation When deformation around the bolt holes is not a design consideration, the nominal bearing strength [resistance], P n, of the connected sheet for each loaded bolt shall be determined in accordance with Eq. E3.3.1-1. The safety factor and resistance factors given in this section shall be used to determine the allowable strength or design strength [factored resistance] in accordance with the applicable design method in Section A4, A5, or A6. P n = C m f d t F u (Eq. E3.3.1-1) = 2.50 (ASD) = 0.60 (LRFD) = 0.50 (LSD) where C = Bearing factor, determined in accordance with Table E3.3.1-1 m f = Modification factor for type of bearing connection, which shall be determined according to Table E3.3.1-2 d = bolt diameter t = Uncoated sheet thickness F u = Tensile strength of sheet as defined in Section A2.1 or A2.2

Table E3.3.1-1 Bearing Factor, C AISI Coittee on Specifications for the Design of Coittee/Subcoittee Ballot: CS11-345C Connections with Connections with or s s Subcoittee 3, Connections August 15, 2012 Thickness of Connected Part, t, () Ratio of Fastener Diameter to Member Thickness, d/t C Ratio of Fastener Diameter to Member Thickness, d/t C d/t 10 3.0 d/t < 7 3.0 0.024 t < 0.1875 10 d/t 22 4-0.1(d/t) 7 d/t 18 1+14/(d/t) (0.61 t < 4.76) d/t > 22 1.8 d/t > 18 1.8 : or short-slotteoles within the lap of lapped or nested Z-members as restricteddefined byin Section E3 shall be is permitted to be considered as standaroles. Table E3.3.1-2 Modification Factor, m f, for Type of Bearing Connection Type of Bearing Connection m f s wwith Washers Under under Both Head and Nut 1.00 s wwithout Washers under Both both Head and Nut, or With with Only only One Washer or s Parallel to the Applied Load without Washers under both Head and Nut, or with only One Washer s Perpendicular to the Applied Load Wwithout Washers Uunder Bboth Head and Nut, or Wwith Oonly One Washer Inside Sheet of Double Shear Connection Uusing s wwith or Without without Washers Inside Sheet of Double Shear Connection Uusing or Short- Slotted s Parallel to the Applied Load Wwith or without Washers 0.75 0.70 0.55 1.33 1.10 Inside Sheet of Double Shear Connection Uusing s 0.90 Perpendicular to the Applied Load with or without Washers : or short-slotteoles within the lap of lapped or nested Z-members as defined in Section E3 shall be is permitted to be considered as standaroles. E3.3.2 Bearing Strength [Resistance] With Consideration of Deformation When deformation around a bolt hole is a design consideration, the nominal bearing strength [resistance], P n, shall be calculated in accordance with Eq. E3.3.2-1. The safety factor and resistance factors given in this section shall be used to determine the available strength [factored resistance] in accordance with the applicable design method in Section A4, A5, or A6. In addition, the available strength shall not exceed the available strength obtained in accordance with Section E3.3.1.

AISI Coittee on Specifications for the Design of Coittee/Subcoittee Ballot: CS11-345C Subcoittee 3, Connections August 15, 2012 P n = (4.64 t + 1.53)dtF u = 2.22 (ASD) = 0.65 (LRFD) = 0.55 (LSD) where = Coefficient for conversion of units = 1 for US customary units (with t in inches) = 0.0394 for SI units (with t in ) = 0.394 for MKS units (with t in cm) See Section E3.3.1 for definitions of other variables. (Eq. E3.3.2-1) E3.4 Shear and Tension in s See Section E3.4 of Appendix A or B for provisions provided in this section. A,B

AISI Coittee on Specifications for the Design of Coittee/Subcoittee Ballot: CS11-345C Subcoittee 3, Connections August 15, 2012 Specification Appendix A: E3a ed Connections In addition to the design criteria given in Section E3 of the Specification, the following design requirements shall also be followed for bolted connections used for cold-formed steel structural members, in which the thickness of the thinnest connected part is 3/16 (4.76 ) or less. ed connections in which the thickness of the thinnest connected part is greater than 3/16 (4.76 ) shall be in accordance with ANSI/AISC-360. The holes for bolts shall not exceed the sizes specified in Table E3a, except that larger holes are permitted to be used in column base details or structural systems connected to concrete walls. When the bolt hole deformation is considered in design in accordance with Eq. E3.3.2-1, the following restrictions shall be applied: (d) Standaroles shall be used in bolted connections, except that oversized and slotted holes shall be permitted to be used as approved by the designer.; (e) The length of slotteoles shall be normal to the direction of the shear load; and. (f) Washers or backup plates shall be installed over oversized or slotteoles in an outer ply unless suitable performance is demonstrated by tests in accordance with Chapter F. When the bolt hole deformation is not considered in design, oversizeoles and shortslotted holes are permitted. The holes for bolts shall not exceed the sizes specified in Table E3a. Maximum Size of s, in inches d * < 1 / 2 1 / 2 d + 1 / 32 d + 1 / 8 (d + 1 / 32 ) by (d + 1 / 4 ) ( ) by (d + 1 / 4 ) (d + 1 / 32 ) by (2 1 / 2 d) ( ) by (2 1 / 2 d) 9/16 by 7/8 * The alternative short-slotteole is only applicable for d/t=1/2

AISI Coittee on Specifications for the Design of Coittee/Subcoittee Ballot: CS11-345C Subcoittee 3, Connections August 15, 2012 Maximum Size of s, in millimeters d * < 12.7 12.7 d + 0.8 d + 3.2 (d + 0.8) by (d + 6.4) () by (d + 6.4) * The alternative short-slotteole is only applicable for d/t=12.7 (d + 0.8) by (2 1 / 2 d) () by (2 1 / 2 d) 14.3 by 22.2 Specification Appendix B E3a ed Connections In addition to the design criteria given in Section E3 of the Specification, the following design requirements shall be followed for bolted connections used for cold-formed steel structural members in which the thickness of the thinnest connected part is 4.76 or less, there are no gaps between connected parts, and fasteners are installed with sufficient tightness to achieve satisfactory performance of the connection under anticipated service conditions. ed connections in which the thickness of the thinnest connected part is greater than 4.76 shall be in accordance with CSA S16. Unless otherwise specified, circular holesthe standarole diameter for bolts shall not be greater than the nominal bolt diameter, d, plus 1 for bolt sizes up to 13 and plus 2 for bolt sizes over 13.