catalog Copper Wires

Similar documents
STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

26/35kV Copper XLPE Insulation Electric Cable

40/69 kv to 127/220 kv XLPE

AMWAJ TELECOMMUNICATION FACTORY

PV Solar Wiring Solutions

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

UNITED STATES DEPARTMENT OF AGRICULTURE Rural Electrification Administration BULLETIN 1753F-206(PE-86)

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NEMA Standards Publication No. WC ICEA Publication No. S

Construction guideline

PO Box 1081 Monticello, MN Ph Fax

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Regulatory Compliance/Certifications.

Selection of the Correct Optical Cable Outer Jacket for the Application

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution

STANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS

Engineering Data for Copper and Aluminum Conductor Electrical Cables

*** Supercedes: BECO E and COM , , & ***

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

U.V resistance UL Sunlight Resistance. Flame retardant IEC

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)


BLACK EPR INSULATED MEDIUM VOLTAGE CABLES. Ronald F. Frank, Eng. Consultant

RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015

3 MODIFICATIONS TO EXISTING STANDARDS

NPS/002/023 Technical Specification for 132kV Power Cables.

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

SECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

11-SDMS-01 REV. 03 ( )

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

SERV-RITE Wire and Cable

STANDARD FOR BROADBAND BURIED SERVICE WIRE, FILLED, POLYOLEFIN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS. Published By

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

CABLEMASTER CABLE GUIDE

Cables for Railway Signalling Applications General Requirements

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

15 kv EPR Insulated, Jacketed, URD Cable

Standard of Practice - Campus Electrical Distribution System

EHV XLPE CABLES CDCC LINE

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

SECTION INSULATED WIRE AND CABLE

Cables de Comunicaciones Zaragoza. CW1601 Approval application.

SPECIFICATION FOR FRLS POWER CABLES

Armoured Instrumentation Cables to BS7917

Industry Application Information

SECTION GROUNDING AND BONDING

Technical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

6A V CVQ cable (C rank)

POLYMERIC ARMOR DESIGN OF AN IMPROVED PROTECTION TO MECHANICAL STRESSES AND FLUIDS FOR OIL GAS AND PETROCHEM (OGP) APPLICATIONS

3M Cold Shrink Joint, SC145-II/SS145-II

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557

Technical Specification for Single Core 19/33kV Copper / TR-XLPE Underground Cable

Clark Public Utilities

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

HDPE Conduit Specification 2011

Test Report No.: Page 2 of 35

UNIFIED FACILITIES GUIDE SPECIFICATIONS

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

Termco Heatshrink.

Comparison of BS 5308, PAS 5308 and BS EN

Pair Count Minimum Bend Radius Design Type Maximum Pulling Tension

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

Glossary Of Terms M-1

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

Mar08 Rev A

Purchase Now ANSI/ICEA S

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

Instrumentation Cables

Purchase Now ANSI/ICEA S STANDARD FOR 600 VOLT SINGLE LAYER THERMOSET INSULATED UTILITY UNDERGROUND DISTRIBUTION CABLES

/DB O-002-DF-HY-F02NS/8W002/1X24AWG

WIRING METHODS CHAPTER 38

DUO-THERM 505 Specification Guide

ES2000 TUBING Environmental Sealing, Polyolefin, Semirigid, Adhesive-Lined

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

New Conduit Specification

Transcription:

catalog Copper Wires

ASWire Aerial Service Wire Self Supporting Multi-pair Pair Count 1-18P Multi-pair, self-supporting Aerial Service Wires (ASW) are used for subscriber lines in exchange plant; single-pair is often used for lateral runs from aerial plant. In both single and multi-pair types, the wire core is laid parallel to a solid steel support wire and jacketed in an integral extrusion to form a figure-8 configuration utilizing a 0.109" solid, extrahigh strength steel support member. s:. Solid annealed copper in 19, 22 and 24 : Each conductor is insulated with solid highdensity color coded polyethylene resulting in excellent electrical and mechanical properties. color codes are used for pair identification with color compounds chosen for electrical balance and permanency. Assembly: conductors are carefully twisted into pairs in a manner designed to minimize resistance unbalance. In multi-pair constructions, pair twist lays are varied to minimize crosstalk and meet capacitance unbalance requirements. Twisted pairs are formed into a firm, round core. Outer Jacket: A black, high-molecular weight, polyethylene provides a tough, flexible protective covering that withstands exposure to sunlight, atmospheric temperatures and stresses encountered in standard installations. The steel support wire is jacketed in an integral extrusion with the core. Average Mutual Capacitance @ 1000 Hz nf/mile Wire Average 94 83 ± 7 58 52 ± 4 4SProducts multi-pair ASWire cables are used for subscriber lines in exchange plant. The single-pair is often used for lateral runs from aerial plant. Manufactured to meet requirements for Hard Drawn Copper Wire ASTM B3. DC Unbalance DC Potential Volts 19 mm gigohm/ gigohm/ db/kft db/km ohms/mile ohms/km Avg % pair % 0.90 3.6 11.8 4 28.0 1.1 Cdr 5,000 Sprt. Wire 7,200 22 0.64 5.1 16.7 9 56.4 1.1 4,000 7,200 24 0.50 6.5 21.3 144.0 89.5 1.1 3,000 7,200 Crosstalk Loss Min. FEXT @ 150 khz Min. NEXT @ 722 Khz db/kft db/km 63 58 44 (db) Capacitance Unbalance @1000 Hz Max. Pair-to-Pair Max. Pair-to-Support Wire pf/kft pf/km 80 145 800 2,625

BSWire Buried Service Wire Multi-pair Pair Count 1-6P 4SProducts BSWire is filled, double-jacketed wire designed for direct burial applications and available in 2, 3, and 6 pair sizes. The primary application of a Buried Service Wire is service entrances and distribution circuits. It is filled with PIB base jelly compound, which is chemically and electrically compatible with all other materials in the wire. The compound completely coats each insulated conductor and fills the air space between conductors. s: Solid annealed copper in 19, 22 and 24. : Each conductor is insulated with solid high-density polyethylene in distinctive colors. Surface Marked Jacket Black Polyethylene Core Assembly: conductor dimensions are tightly controlled to limit resistance unbalance of twisted pairs. Pair twist lays are varied to minimize crosstalk and meet capacitance unbalance limits. The wire core is completely filled with PIB base jelly such as BP Naptel 867, filling the air spaces between insulated conductors. Inner Jacket: A black, linear low-density polyethylene inner jacket provides additional mechanical and moisture protection. Shield: A smooth, copolymer-coated, 8 mil aluminum tape is applied longitudinally over the inner jacket and is bonded to the outer jacket. The space under the tape is flooded to eliminate all air space. Outer Jacket: A black, linear low-density polyethylene outer jacket provides a tough, flexible, protective covering that withstands exposure to sunlight, atmospheric temperatures, ground chemicals and stresses expected in standard installation. Average Mutual Capacitance @ 1000 Hz nf/mile Wire Average 94 83 ± 7 58 52 ± 4 Manufactured to meet requirements of ANSI/ICEA S-86-634-1996. DC Unbalance DC Potential Volts mm gigohm/ gigohm/ db/kft db/km ohms/mile ohms/km pair % Cdr Sprt. Wire 19 0.90 3.2 10.0 4 28.0 7,000 20,000 22 0.64 4.6 15.1 9 56.4 5,000 20,000 24 0.50 5.8 19.0 144.0 89.5 4,000 20,000 Crosstalk Loss Min. FEXT @ 150 khz Min. NEXT @ 722 Khz db/kft db/km 63 58 44 (db) Capacitance Unbalance @1000 Hz Max. Pair-to-Pair Max. Pair-to-Ground pf/kft pf/km 80 145 800 2,625

BSWire -n Buried Service Wire Multi-pair - Non Armored Pair Count 2-6P 4SProducts BSWire is filled, double-jacketed wire designed for direct burial applications and available in 2, 3, and 6 pair sizes. The primary application of a Buried Service Wire is service entrances and distribution circuits. It is filled with PIB base jelly compound, which is chemically and electrically compatible with all other materials in the wire. The compound completely coats each insulated conductor and fills the air space between conductors. s: Solid annealed copper in 19, 22 and 24. : Each conductor is insulated with solid high-density polyethylene in distinctive colors. Core Assembly: conductor dimensions are tightly controlled to limit resistance unbalance of twisted pairs. Pair twist lays are varied to minimize crosstalk and meet capacitance unbalance limits. The wire core is completely filled with PIB base jelly such as BP Naptel 867, filling the air spaces between insulated conductors. Inner Jacket: A black, linear low-density polyethylene inner jacket provides additional mechanical and moisture protection. Shield: A smooth, copolymer-coated, 8 mil aluminum tape is applied longitudinally over the inner jacket and is bonded to the outer jacket. The space under the tape is flooded to eliminate all air space. Outer Jacket: A black, linear low-density polyethylene outer jacket provides a tough, flexible, protective covering that withstands exposure to sunlight, atmospheric temperatures, ground chemicals and stresses expected in standard installation. Mutual Capacitance @ 1000 Hz nf/mile Wire Average 94 83 ± 7 58 52 ± 4 DC Unbalance DC Potential Volts mm gigohm/ gigohm/ db/kft db/km ohms/mile ohms/km pair % Cdr 22 0.64 4.6 15.1 9 56.4 5,000 24 0.50 5.8 19.0 144.0 89.5 4,000 Crosstalk Loss Min. FEXT @ 150 khz Min. NEXT @ 722 Khz db/kft db/km 63 58 44 (db) Capacitance Unbalance @1000 Hz Max. Pair-to-Pair Max. Pair-to-Ground pf/kft pf/km 80 145 800 2,625

DCWire -10 Aerial Drop Wire Copper Single-pair s: Two round hard drawn wire copper conductors in diameter of 0.8, 0.9 and mm ASTM B3. : s are laid in a parallel resistant, all-weather black polyethylene compound that serves as both insulation and jacket. One raised ridge tracer on one edge of the jacket provides conductor polarity identification. 4SProducts DCWire -10 cables are used for extending an open wire line and/or distribution cable pair from a pole and/or cable terminal to a building. Manufactured to meet requirements for Hard Drawn Copper Wire ASTM B3. DC DB/kft db/km ohms/km 18 100 30 4 13.1 23.39 3 minutes- no Volts AC 4,000 0.12 3.0 2.5 6.3 0.13 3.3 1,6 500 29.5 39.0

DSWire -10 Aerial Drop Wire Copper Clad Steel Single-pair s: Two round 18.0 solid 30% conductivity extra high strength copper/steel wires serve dually as conductors and strength members. Optimized tensile breaking strength and elongation assure superior toughness against ice loading and impact from falling ice-coated tree limbs and other mechanical shocks. : s are laid in a parallel resistant, all-weather black polyvinyl chloride compound that serves as both insulation and jacket. One raised ridge tracer on one edge of the jacket provides conductor polarity identification. 4SProducts DSWire -10 cables are designed for extending an open wire line or distribution cable pair from a pole and/or cable terminal to a building. Manufactured to meet requirements of ASTM B-227; BS- 6004. DC DB/kft db/km ohms/kft ohms/km 18 100 30 4 13.1 24.5 80.4 3 seconds - no Volts DC in Dry Water 12,100 7,050 0.12 3.0 0.25 6.3 0.13 3.3 1000 305 29 43.2

DSWire -12 Aerial Drop Wire Copper Clad Steel Single-pair s: Two round 18.0 solid 30% conductivity extra high strength copper/steel wires serve dually as conductors and strength members. Optimized tensile breaking strength and elongation assure superior toughness against ice loading and impact from falling ice-coated tree limbs and other mechanical shocks. : s are laid in a parallel resistant, all-weather black polyvinyl chloride compound that serves as both insulation and jacket. One raised ridge tracer on one edge of the jacket provides conductor polarity identification. 4SProducts DSWire -12 cables are designed for extending an open wire line or distribution cable pair from a pole and/or cable terminal to a building. Manufactured to meet requirements of REA PE-7; ASTM B-227; BS-6004. DC DB/kft db/km ohms/kft ohms/km 18 100 30 4 13.1 24.5 80.4 3 seconds - no Volts DC in Dry Water 12,100 7,050 0.13 3.4 0.28 7.1 0.15 3.7 1000 305 29 43.2

DSWire -14 Aerial Drop Wire Copper Clad Steel Single-pair s: Two round 18.0 solid 30% conductivity extra high strength copper/steel wires serve dually as conductors and strength members. Optimized tensile breaking strength and elongation assure superior toughness against ice loading and impact from falling ice-coated tree limbs and other mechanical shocks. : s are laid in a parallel resistant, all-weather black polyvinyl chloride compound that serves as both insulation and jacket. One raised ridge tracer on one edge of the jacket provides conductor polarity identification. 4SProducts DSWire -14 cables are designed for extending an open wire line or distribution cable pair from a pole and/or cable terminal to a building. Manufactured to meet requirements of REA PE-7; ASTM B-227; BS-6004. DC DB/kft db/km ohms/kft ohms/km 18 100 30 4 13.1 24.5 80.4 3 seconds - no Volts DC in Dry Water 12,100 7,050 0.15 3.8 0.31 7.8 0.16 4.0 1000 305 29.5 43.9

DSWire -15 Aerial Drop Wire Copper Clad Steel Single-pair s: Two round 18.0 solid 30% conductivity extra high strength copper/steel wires serve dually as conductors and strength members. Optimized tensile breaking strength and elongation assure superior toughness against ice loading and impact from falling ice-coated tree limbs and other mechanical shocks. : s are laid in a parallel resistant, all-weather black polyvinyl chloride compound that serves as both insulation and jacket. One raised ridge tracer on one edge of the jacket provides conductor polarity identification. 4SProducts DSWire -15 cables are designed for extending an open wire line or distribution cable pair from a pole and/or cable terminal to a building. Manufactured to meet requirements of REA PE-7; ASTM B-227; BS-6004 and ANSI/ICEA S-89-648-1993. DC DB/kft db/km ohms/kft ohms/km 18 100 30 4 13.1 24.5 80.4 3 seconds - no Volts DC in Dry Water 12,100 7,050 0.15 3.9 0.31 7.8 0.16 4.0 1000 305 3 46.0