FLOTATION CONTROL & OPTIMISATION

Similar documents
MILLING CONTROL & OPTIMISATION

A Holistic Approach to Control and Optimisation of an Industrial Crushing Circuit

SAG Page 2. Page 1

Increasing Grinding Circuit Robustness with Advanced Process Control

SimSci APC. Model Predictive Control to Improve Your Process Economics

FEATURES AND BENEFITS

SAG Mill Control at Northparkes Mines (Not So Hard After All)

MODEL PREDICTIVE CONTROL APPLICATION AT LUMWANA COPPER CONCENTRATOR

Information Technology Solutions Neptune Datasheet

KnowledgeScape! EfficiencyExpert! Increase Profit. Reduce loss.

SAGwise total process control The key to efficient SAG mill operation

Alternatives to Optimize Gas Processing Operations

DeltaV InSight. Introduction. Benefits. Gain new process insight from embedded process learning. Easily identify underperforming control loops

DeltaV InSight. DeltaV InSight. Introduction. DeltaV Product Data Sheet. Gain new process insight from embedded process learning

Research on Optimization of Metallurgical Process Based on Data-Driven

Connoisseur. Software Datasheet MODEL PREDICTIVE CONTROL TO IMPROVE YOUR PROCESS ECONOMICS MAXIMIZE YOUR PROFITS. Summary.

Re-defining Energy Management

EMC FLOTATION TEST PROCEDURE 2 LABORATORY FLOTATION TEST PROCEDURE FOR MF1 AND MF2 TESTS AND REGRINDING OF CLEANER TAILINGS

GE Intelligent Platforms

Best Practices for Controller Tuning

DeltaV InSight. DeltaV InSight. Introduction. DeltaV Product Data Sheet. Gain new process insight from embedded process learning

Process Control and Optimization Theory

ADVANCED CONTROL STRATEGIES FOR POLYOLEFIN GAS PHASE PROCESSES

Daniel A. Silva Minera Los Pelambres, Salamanca, Chile. Matt F. McGarry ANDRITZ AUTOMATION, Bellingham WA, USA

Operational Excellence on the plant floor and in the control room: A disciplined approach to understanding the opportunities to maximise the

Use of automation to improve productivity and quality in long product rolling mills

Stabilisation of the Nickel Sulphide Concentrate Volumetric Flow Rate and Implementation of Mass Pull Control Strategy at Nkomati Mine

Industrial IT : Optimization for the Cement Industry

IntelliSense.io Case Study Thickener Circuit Optimisation

Flotation Process Optimisation through Frequent In-line Grade Measurement as an alternative to Sampling Surveys that deliver outdated results

Process optimization using real time tracking of coarse material in individual cyclone overflow streams

FLSmidth Dorr-Oliver Eimco Flotation Technology. Superior Metallurgy Higher Availability

Dynamic Simulation for APC projects A case study on a Reformate Splitter with side draw. Dr Sebastien OSTA TOTAL Jose Maria FERRER Inprocess

Making APC Perform 2006 ExperTune, Inc. George Buckbee, P.E. ExperTune, Inc.

EMC FLOTATION TEST PROCEDURE 2 LABORATORY FLOTATION TEST PROCEDURE FOR MF1 AND MF2 TESTS AND REGRINDING OF CLEANER TAILINGS

ITACA TM PRODUCTION AND DOSING SYSTEM

Improved flotation performance at Karee Platinum Mine through better level control

MINING CHEMICALS CASE STUDY. Overview This case study outlines a successful commercial implementation of Orfom D8

Interaction Detection Using Oscillation Analysis

Case study of the use of Simatic Batch at Ursus Breweries, Timisoara

An Experimental Liquid Cooling System Dynamic Simulator for the Evaluation of Intelligent Control Techniques

White Paper. Transforming Contact Centres using Simulation-based Scenario Modelling

ICP Expert software. Technical Overview. Introduction

Process assurance and monitoring in GMA welding Heinz Hackl, Wels

Improve Process Performance by Validating Systems and Preparing Operations

The new BioPAT MFCS 4

AN EFFICIENT APPROACH TO COBALT, COPPER AND NICKEL RECOVERY FROM RAFFINATES, EVAPORATION PONDS, AND OTHER LOW GRADE STREAMS

Development of an Innovative Copper Flowsheet at Phu Kham. M F Young and I Crnkovic

Applying Dynamic Process Simulations Toward Flaring Reduction

ONTIME, for creating and managing timetables

System Integration of Automated Mine Optimization System

Virtual Planning Room - Analytical Mine Planning Work, Based on Tools Integration and a Robust Cloud Information System

The world s finest system for scheduling feedstocks, operations and products in refineries, chemicals and petrochemical plants

AN ADVANCED MODELLING TECHNIQUE FOR SCALE-UP OF BATCH FLOTATION RESULTS TO PLANT METALLURGICAL PERFORMANCE G S DOBBY AND O N SAVASSI - SGS

Energy-Mass-Size balance model for dynamic control of a wet open circuit grinding mill: Part II Simulation tests

PROCESS AND ASSET MONITORING AT A PGM CONCENTRATOR FOR UG2 CONCENTRATE

APPLICATION NOTE AN902

Page 1 of 5. Sonar Technology: More than Just a Flow Meter - Leveraging Dual Measurement Capability for Enhanced Value in Industrial Processes

Dynamic Modeling for Design of Ion Exchange Systems. Khosrow Nikkhah

ABB Cement Fingerprint Holistic Approach for Cement Industries

THE KINCALC FLOTATION KINETICS CALCULATOR AND ORGANISER

PI Alchemy Turning data into Gold

Resource Efficient Mining Processes of Tomorrow

Determining in-depth plant performance

Asset Performance Management for Mining

A Computer Controlled Multi-Analysis Titration System

HC900 Hybrid Controller When you need more than just discrete control

JKSIMFLOAT V6.1 PLUS : IMPROVING FLOTATION CIRCUIT PERFORMANCE BY SIMULATION

Dynamic Load Management Ripple Control The most reliable technology for load management in the electricity industry.

Innovative testing of advanced PLCs of sewage water pumping stations

Flotation cplant: an Optimum Modular Approach

Brief Summary of Last Lecture. Model checking of timed automata: general approach

ENGINEERING SERVICES

ECNG 3032 CONTROL AND INSTRUMENTATION Introduction To Process Control

Prioritizing and Optimizing Problem Loops Using a Loop Monitoring System

An Evolution of Step Testing and its Impact on Model Predictive Control Project Times

GENe DMS. Why choose GENe DMS? GE Energy Digital Energy

1/2 Siemens WT Siemens AG 2011

Totally Integrated Automation Portal

Shift Your Focus from Analysis to Optimization Using Active Model Capture Technology

Shift Your Focus from Analysis to Optimization Using Active Model Capture Technology

Instrumentation & Controls. Siemens Power Plant Automation -- SPPA-T3000. Technical Highlights. The New Benchmark in Control.

49. MASS BALANCING AND DATA RECONCILIATION EXAMPLES

Energy Reduction and Biological Process Performance Improvements with Right-Sized Equipment and Next-Generation Process and Aeration Controls

Comparison between Different Control Approaches of the UOP Fluid Catalytic Cracking Unit

Environmental Discovery System

AUTOMATIC CONTROL OF A HIGH TENSION ROLL SEPARATOR

IPS Inclined plate settlers. Maximum process recovery, minimum plant footprint

12th International Conference on Fluidized Bed Technology

Flexibility! Multi-Carrier-System. Simply more productive!

Innovative Operation Strategies for Improving Energy Saving in a Cooling Tower System

Don t Tune These Four Loops!

Software for heat treatment

Laboratory Flotation Testing An Essential Tool for Ore Characterisation

ADVANCED PROCESS CONTROL

Evaporation and Spray Drying Optimisation

Room automation for laboratories. Safety and a pleasant climate for life sciences and the healthcare sector.

DESIGN AND DEVELOPMENT OF 3 ELEMENT CONTROL OF BOILER

TECHNICAL SPECIFICATION SDI C. Automated Ultrasonic Heavy Duty Cylinder Inspection System

Developing Process Control Standards for Optimal Plant Performance at PanAust Limited

Transcription:

FLOTATION CONTROL & OPTIMISATION A global leader in mineral and metallurgical innovation

FLOATSTAR OVERVIEW Flotation is a complex process that is affected by a multitude of factors. These factors may be inherent in the circuit design, or in how the flotation plant is operated. The FloatStar suite of control modules utilises advanced process control to overcome design-related limitations and maximise circuit performance during operation. As far as possible, Mintek s control modules are designed to be implemented with little or no additional instrumentation. Mintek s modular approach ensures the design of a customised solution, specific to the objectives of each plant. Furthermore, this approach allows for phased implementations which are useful both in assessing the benefit of the system, and in allowing plant personnel to be introduced gradually to any changes in operation (Change-Management). The diagram below illustrates Mintek s bottom-up approach to flotation stabilisation and optimisation: Management Information System FloatStar Flow Optimiser FloatStar Grade-Recovery Optimiser FloatStar Reagent Optimiser Optimisation FloatStar Level Stabiliser FloatStar ph Controller Stabilisation FloatStar Level Fault Detector FloatStar Performance Monitor FloatStar Dynamic Simulator Simulators Process Monitoring Plant Control Plant Instrumentation Plant

STABILISATION Level Stabiliser The FloatStar Level Stabiliser has been implemented on flotation circuits around the world. It has repeatedly been proven efficient in rejection of disturbances, and in rapid tracking of setpoints. The main difficulty in controlling flotation levels is that they form part of a highly interconnected system. The control actions of one bank will therefore influence other banks and, unless handled correctly, disturbances will propagate through the circuit. This means that good level stabilisation control cannot be achieved by using controllers that only act locally. The top two figures on the right show how a disturbance will propagate through the circuit. Bank 1 Bank 2 Bank 3 The FloatStar Level Stabiliser solves this problem, and is designed to provide the following benefits: Fast setpoint tracking by: Considering all levels simultaneously to eliminate interaction. Rejecting disturbances quickly and efficiently throughout the entire circuit. Level Bank 1 Bank 2 Reduced startup time: Typically a reduction from over 3 hours to under 1 hour in the time taken to stabilise the final tails grade. Improved overall recovery: On numerous plants, processing a wide range of mineral types, the FloatStar Level Stabiliser has consistently increased recovery by between.5% and 1.3%. On most minerals processing plants, the payback period is in the order of 1 to 3 months. Bank 3 Time Disturbance is Propagated Case study Performance testing, with a benefit analysis, has been performed on concentrator plants of several different mineral types. On-Off tests during normal operation, as well as benefit achieved during startups were assessed. Comparison of controller performance The graph on the right shows a comparison of normal PID control to FloatStar Level Stabilisation. Worth noting is how, under PID control, the disturbances from the first banks are magnified further downstream. The control has visibly improved while the FloatStar Level Stabiliser was in operation. The general deviation from setpoint has decreased markedly, and changes to setpoint are tracked rapidly and without producing downstream disturbances. The table below shows the Integral of Absolute Error (IAE) controller performance measure. The deviation from setpoint under FloatStar Level Stabiliser control is considerably lower than under normal plant PID control. Level (% - values shifted for clarity) 7 6 5 4 3 2 1 Plant PID Control FloatStar Level Stabiliser 5:3: 6:2: 7:1: 8:: 8:5: Time (hours) IAE Rougher1 Rougher2 Rougher3 Rougher4 Rougher5 Rougher6 Rougher7 Rougher8 Rougher9 IAE OFF 13.42 14.84 25.59 56.13 93.76 129.64 139.89 195.76 116.64 IAE ON 9. 7.58 8.38 1.32 6.29 6.6 8.1 8.63 8.34

Benefit during startup The plant used for this case study processed two different mineral types. Measurements were taken regularly while the plant was starting up, once under PLC PID control and once under FloatStar Level Stabiliser control. The graph on the right shows a comparison of the tailings grade measurements during the startup procedure. It is clear that the startup under FloatStar Level Stabiliser control stabilises more rapidly, and with lower tailings grades, than that using PID control. Mineral 2 (ppm) 25 2 15 1 5 Tailings Grade Time Period Considered 1.6 hrs 1.4 1.2 1.8.6.4.2 Mineral 1 (ppm) The table below shows the quantitative economic evaluation of the savings achieved by using the FloatStar Level Stabiliser for circuit startup. A total savings of US$75 was achieved on each startup by using the FloatStar system. 2 4 6 8 1 12 14 Time (minutes) Mineral 1 FloatStar Mineral 1 PID Mineral 2 Floatstar Mineral 2 PID Mass flow of tailings stream: 1975 tons/hr Time period of benefit/loss calculation: 1.6 hrs Cost of mineral 1: US$ 35/oz Mineral 1 lost by PID control compared to FloatStar control:.2ppm Mass of mineral 1 lost 527g (18.6oz) Cost of mineral 1 lost US$ 65 Cost of mineral 2: US$ 1528/ton Mineral 2 lost by PID control compared to FloatStar control 25 ppm Mass of mineral 2 lost:.66 tons Cost of mineral 2 lost: US$ 1 Savings by using FloatStar Level Stabiliser during startup: US$ 75 OPTIMISATION Flow Optimiser With the FloatStar Level Stabiliser providing circuit stability and rapid setpoint tracking, it then becomes possible to consider flotation optimisation. The FloatStar Flow Optimiser controls circulating loads and mass pull in the flotation circuit. It is well known that circuit performance (grade and recovery) is strongly affected by these parameters. By stabilising circulating load and mass pull, it is possible to ensure consistent circuit performance. The Flow Optimiser uses multivariable control techniques to continually optimise the numerous variables that affect circuit flows. Typically these are the level and air setpoints in different sections of the plant. Depending on the circuit configuration and available instrumentation, the FloatStar Flow Optimiser can be used to control any of the following parameters: Controller Mass Pull Control Residence Time Controller Required Equipment Flowmeter on Concentrate Line Densitometer on Concentrate Line None Mass pull rates. Residence times. Internal flowrates. Flow Controller Flowmeter

Mass Pull Control In order to obtain a constant mass pull from a flotation train, all of the banks that produce concentrate need to be set at the correct level and air setpoints, as these affect the mass pull achieved. The FloatStar Flow Optimiser makes use of multivariable techniques to achieve the desired mass pull rates from these banks, in the manner depicted by the image right: AIR AIR By automatically adjusting the level and air setpoints on the final stages, the mass pull can be accurately controlled and maintained throughout changing ore conditions and circuit upsets, thereby ensuring tonnage targets. Sump Mass Pull Setpoint F D Controlled Variable: Mass Pull Pump Concentrate Measured Values: Density & Flowrate of Concentrate Manipulated Variables: Level and Air Setpoints Residence Time/Re-Circulating Load Controller The mechanics of flotation shows that there is a direct impact on recovery as the residence time changes. AIR AIR AIR AIR It is possible with the FloatStar Flow Optimiser to control the inferred flow, and hence the residence time of a bank, to setpoint. The residence time (and re-circulating load in the case of a closed circuit) can be stabilised ensuring maximum efficiency of key flotation banks thereby improving overall circuit performance. Controller Load SP / τ SP Residence time Controlled Variable: Measured Values: Manipulate d Variables: Residence Time None - Values Inferred Air and Level Setpoints of Banks Supplying Concentrate Case Study of implemented Residence Time controller Consider the flotation circuit shown in the figure right which is currently employed by one of our clients. The aim is to control the residence time of PC6 by adjusting the setpoints of the banks supplying concentrate. The multivariable algorithm of the optimiser determines changes to the air and level setpoints. PR1 PR2 PC1 PR3 PC2 PR4 PC3 SR1 PC4 SR2 PC5 SR3 Circuit Configuration PC6 PR: Rougher SR: Secondary Rougher PC: Cleaner

A special estimating filter based on available plant measurements is used to infer the flowrate through PC6 and hence estimate the residence time. With this estimation the optimising algorithm is able to adjust the level and aeration PID setpoints of the Roughers and 8 Cleaners. Froth Depth (mm) 7 6 5 4 3 2 1 Control of Concentrate Flow. Manipulation of Rougher Level-Setpoints. FloatStar Level Stabiliser Time (hours) Control of Concentrate Flow. Manipulation of Aeration Rate Setpoints. FloatStar Level Stabiliser FloatStar Flow Optimiser 4.5 4 3.5 3 FloatStar 2.5 Flow Optimiser 2 PR 1 1.5 PR 2 1 PR 3 PR 4.5 SR 1 SR 2 1 2 3 4 5 6SR 7 38 9 12 13 14 15 16 17 18 19 2 21 22 23 24 25 PC 6 Time (hours) PC 7 PC 8 PC 9 PC 1 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 PR: Rougher SR: Secondary Rougher PC: Cleaner The graph right shows the inferred cleaner tailings flow over a 25-hour period, which is directly related to the residence time in the bank. Under normal PID control, it can be seen that there is virtually no control of the residence time. However, when the Flow Optimiser is switched on, the tailings flow is rapidly and tightly controlled to setpoint. In this case, the Flow Optimiser manipulated both the aeration rates and level setpoints of relevant Rougher and Cleaner banks. PID FloatStar Flow Optimiser Standard Deviation of Flow Error from Setpoint 4.2 2.2 1.44 Inferred Flow (%) 3 25 2 15 1 5 PID FloatStar Level Stabiliser only FloatStar Flow Optimiser with Level Stabiliser 1 3 4 6 7 8 111 14 17 19 22 25 Flow Controller Time (hours) Another example of effective circuit optimisation is the control of a tailings flowrate in the cleaning stages. The level and air setpoints of the banks supplying concentrate are manipulated in order to obtain the desired tailings flowrate. Controlled Variable: Measured Values: Manipulated Variables: Tailings Flowrate Flow Rate, or Inferred Flow Rate Air & Level Setpoints of Banks Supplying Concentrate Additional features and benefits: The relative mass pull contributions from the different banks can be specified. Operation of the circuit is steered away from bottlenecks (e.g. valves saturating). Built-in safety loops prevent limits from being violated. The FloatStar Flow Optimiser has been successfully implemented on numerous flotation circuits with varying configurations and degrees of instrumentation and automation. The fast level setpoint tracking that can be achieved by the FloatStar Level Stabiliser further enhances the performance of the optimisation strategy.

Grade-Recovery Optimiser With the increase in availability of online grade analysis, it is now possible to manipulate the flotation circuit operating conditions to optimise plant performance. Developed as a result of these advancements, the FloatStar Grade-Recovery Optimiser provides continuous, online optimisation of circuit operation throughout fluctuating plant conditions. Typically, flotation circuits aim to produce a concentrate grade of a specified quality, while recovering as much of the valuable mineral as possible. The behaviour of the circuit (ultimately the final grade and recovery) will be influenced by, amongst others, the: Level setpoints. Aeration rates. Bank residence times. Reagent addition. Choosing the correct values for these variables will ensure that the best recovery will be obtained for a specified grade. Grade and Recovery (%) 1 3 25 9 8 7 6 5 4 3 Recovery has dropped below the minimum 2 Concentrate grade is 1 sacrificed 1 2 3 4 5 6 7 8 9 1 Time (hours) Rougher 1+2 On-Off Data In most cases, the Grade-Recovery Optimiser is configured to prioritise recovery while attempting to ensure a consistent product grade. In the simulated scenario (top graph on the right), at one point the recovery has dropped below the minimum. The Grade-Recovery Optimiser then adjusts the circuit operation to increase the recovery. As a consequence, the concentrate grade decreases. The graph on the right (actual plant data) illustrates the following benefits of the Grade-Recovery Optimiser: Grade (%) 2 15 1 5 6 7 8 9 1 Recovery (%) Reduction in the variation of the grade (y-axis). Increased recovery (x-axis). Off On Since it is in touch with the entire circuit, it is able to constantly and consistently optimise the full spectrum of variables to ensure peak circuit performance at all times. LIC LIC LIC LIC Gt Gf LIC LIC LIC LIC Gt Gc The figure to the right shows how the Grade-Recovery Optimiser would be installed on the Rougher section of a typical circuit. Grade Recovery Optimiser Case study The graph on the right shows the typical effect of the optimiser on the level setpoints of the circuit. The levels being manipulated are the three lines of four rougher banks each. These banks were self-aspirating, and hence the aeration rate was not available for manipulation. The objectives of the optimiser on this section of the circuit were as follows: Control Rougher concentrate grade to setpoint. Maximise Rougher recovery. Level (% - value shifted for clarity) Recovery Minimum Recovery 1 16 9 14 8 12 1 8 7 6 5 4 6 3 4 2 2 1 Grade Grade SV 2 4 6 8 1 12 Time (hours) Grade and Recovery (%)

A benefit analysis was conducted on a copper plant using the Grade-Recovery Optimiser. On and Off data were collected over several months, and the difference in performance was assessed. Statistical techniques were used to verify the results. The values were found to be valid with a 95% statistical confidence. The table below shows the results of this analysis: Normal PID Control (mean) Grade-Recovery Optimiser (mean) Difference Recovery 86.36% 88.35% 1.99% improvement Feed Grade 1.632% 1.634% Statistically equal Concentrate Grade 37.51% 37.32% Statistically equal Tailings Grade.226%.197%.29% decrease Reagent Optimiser Reagents play an important role in froth flotation. They strongly affect the performance of the circuit and contribute considerably to the circuit operating costs. The selection of the reagent suite is a complex task, with multiple, often counterintuitive, rules and calculations. The Reagent Optimiser aims to automate this process, to provide consistent round the clock adjustments to the reagent suite tailored to the plant operating conditions. Reagent The figure on the right is a graphical representation of a fuzzy logic calculation that forms part of the Reagent Optimiser. In this case, the plant concentrate and tailings grade readings are used to make decisions regarding adjustments to one of the plant reagents. Tailings Grade Concentrate Grade Features: Incorporates fuzzy logic. Uses plant feedback. Nonlinear, multi-input, multi-output controller. Functions cooperatively with operators and metallurgists. Customisable for additional calculations and logic. Detection of, and reaction to, invalid grade measurements. Automatic adjustment to feed tonnage changes. Plant-specific switch-on logic. Complements the FloatStar Grade-Recovery Optimiser. Benefits: Consistent changes to reagents. Efficient usage of reagents through continuous analysis of circuit requirements, thus decreasing reagent usage. Maximises recovery by preventing unnecessary losses due to reagent under-dosing. The Reagent Optimiser can be combined as a comprehensive solution with the Flow and/or Grade-Recovery Optimisers to ensure optimal plant performance.

PROCESS MONITORING Performance Monitor Controllers must not only perform well in the conditions under which they were installed and tuned, but must also be robust through fluctuating plant conditions. The FloatStar Performance Monitor keeps track of controller performance at all times, and produces useful diagnostic information to analyse when and why controllers are not performing at their peak. Both plant personnel and control engineers will find this information useful in ensuring that their controllers are always performing well. Currently the Performance Monitor: Provides a comparison of the performance of the flotation circuit when the controller is on and off. Compares the current performance to a defined Optimal Performance. Can be configured to reject specific invalid operational periods (e.g. very low flows, saturated actuators). Determines periods of poor performance. Provides diagnostic information for determining faults. Level Fault Detector The FloatStar Level Fault Detector is an online module that detects level-related faults in sumps and flotation banks. It provides useful feedback regarding flotation and general level-instrument performance. The Level Fault Detector has several fault-detection routines, and a general statistics and performance-monitoring package. The fault detection routines include a frozen signal detector, a signal-spike detector and an overflow detector. The statistics module provides information on a moving window of data, including minimum value, maximum value, average, standard deviation and instrument resolution. A graphical interface also forms part of the fault detector package. This interface has been designed to give the users intuitive feedback regarding faults on the plant, without overloading them with too much information or alarms. Measurement Examples of Spikes Time Example of Frozen Signals The figures on the right are examples of spiking and frozen signals. Measurement Time

ADDITIONAL STABILISATION ph Control The control of ph is required in a vast number of areas in the mining industry. A key area is in flotation reagent control systems. There are a number of difficulties in controlling ph: Setpoint Non-linearity of the ph curve; Silting up of the base (typically CaOH) feed -valve. Compensating for changing feed conditions. The FloatStar ph controller is designed to handle all of these control difficulties and consists of: CaOH ph Controller ph F Feed An advanced multi-variable algorithm, including feedforward and feedback compensation. Non-linear compensation. Fault detection algorithms. Mixing Tank The above techniques have been combined into a ph controller that is simple to set up, and provides robust control in an industrial environment. SIMULATORS Dynamic Flotation Simulator The FloatStar Dynamic Simulator is a tool for modelling flotation circuits. It incorporates a mechanistic model that takes into account the dynamics of both true flotation and particle entrainment. Actual Plant The simulator has two modes of operation: True dynamic mode and steady-state mode. In dynamic mode the simulator mimics an actual plant, with dynamic responses to changes in plant operating conditions. The steady-state mode is more useful for testing different plant designs and configurations. Simulator The dynamic mode allows the user to: Change flowrates, valve positions and other dynamic plant properties during run-time. Predict the process response due to changes in head grade, flowrates, level setpoints and air setpoints. Prototype control and optimiser systems for an actual plant. Train operators using SCADA-like frontends. In the steady-state mode the user can: Change steady-state variables such as flotation bank areas and circulating loads. Trial different plant designs. Optimise steady-state variables such as residence times.

Website: www.mintek.co.za/floatstar.html Contact Details: e-mail: floatstar@mintek.co.za Tel: + 27 ()11 79 4379