Storm Sewer Design. Bob Pitt University of Alabama and Shirley Clark Penn State Harrisburg

Similar documents
Runoff Calculations. Time of Concentration (T c or t c ) from one location to another within a watershed. Travel

Drainage Analysis. Appendix E

RETENTION BASIN EXAMPLE

FORT COLLINS STORMWATER CRITERIA MANUAL Hydrology Standards (Ch. 5) 1.0 Overview

Basics of Wastewater Collection System

Detention Pond Design Considering Varying Design Storms. Receiving Water Effects of Water Pollutant Discharges

Introduction to Storm Sewer Design

Rational Method Hydrological Calculations with Excel COURSE CONTENT

Learning objectives. Upon successful completion of this lecture, the participants will be able to describe:

Module 10b: Gutter and Inlet Designs and Multiple Design Objectives

INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GASTON GYPSUM POND ALABAMA POWER COMPANY

the 2001 season. Allison brought high winds and street flooding to Houston, after

INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT BARRY ASH POND ALABAMA POWER COMPANY

MODULE 1 RUNOFF HYDROGRAPHS WORKSHEET 1. Precipitation

DRAINAGE CRITERIA MANUAL (V. 1) RUNOFF

CVEN 339 Summer 2009 Final Exam. 120 minutes allowed. 36 Students. No curve applied to grades. Median 70.6 Mean 68.7 Std. Dev High 88 Low 24.

PRELIMINARY MUNICIPAL SERVICING REPORT NORTHWOODS SUBDIVISION. Prepared for: North Grassie Properties Inc.

APPENDIX G HYDRAULIC GRADE LINE

ENGN.4010 ENGINEERING CAPSTONE DESIGN Watershed Analysis. CiA

Extended Detention Basin Design

WASTEWATER & STORM WATER COLLECTION AND REMOVAL

Hydrology Study. For Bella Terrazza Portion of Lot 1, Block 39, Subdivision of S Tract, Rancho El Cajon El Cajon, CA 92021

Hydrology for Drainage Design. Design Considerations Use appropriate design tools for the job at hand:

INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GREENE COUNTY ASH POND ALABMA POWER COMPANY

Run-on and Run-off Control System Plan

HY-12 User Manual. Aquaveo. Contents

Report. Inflow Design Flood Control System Plan St. Clair Power Plant St. Clair, Michigan. DTE Energy Company One Energy Plaza, Detroit, MI

100-yr Design Runoff (cfs) Basin ID 103b A a B B C Totals

HYDROLOGIC-HYDRAULIC STUDY ISABELLA OCEAN RESIDENCES ISLA VERDE, CAROLINA, PR

The Islamic University of Gaza- Civil Engineering Department Sanitary Engineering- ECIV 4325 L5. Storm water Management

Inflow Design Flood Control System Plan

CEE 371 Water and Wastewater Systems

Storm Sewers, Page 2

Learn how to design inlet grates, detention basins, channels, and riprap using the FHWA Hydraulic Toolbox and WMS

Summary of Detention Pond Calculation Canyon Estates American Canyon, California

Storm Sewer Design - Introduction

Table of Contents. Overview... 1

APPENDIX F RATIONAL METHOD

Report. Inflow Design Flood Control System Plan Belle River Power Plant East China, Michigan. DTE Energy Company One Energy Plaza, Detroit, MI

Learning objectives. Upon successful completion of this lecture, the participants will be able to:

CIE4491 Lecture. Quantifying stormwater flow Rational method

Table of Contents. Overview... 1

TECHNICAL MEMORANDUM. SUBJECT: Determination of watershed historic peak flow rates as the basis for detention basin design

10.0 Storm Sewer Systems

Section 600 Runoff Table of Contents

PRELIMINARY DRAINAGE REPORT FOR THE EDI MASTER PLAN

NCEES NCEES-PE. NCEES - PE Civil Engineering.

Chapter 6. Hydrology. 6.0 Introduction. 6.1 Design Rainfall

WinSLAMM v Program Modifications Final, 3/16/19

BMP Design Aids. w w w. t r a n s p o r t a t i o n. o h i o. g o v. Equations / Programs

DERIVATION AND CALIBRATION OF VOLUME-BASED RUNOFF COEFFICIENTS FOR DENVER AREA, COLORADO

St. Boniface Industrial Park Phase 2 Municipal Servicing Report

6 STOREY CONDOMINIUM 7480 DERRY ROAD WEST, MILTON

PRELIMINARY DRAINAGE STUDY

TECHNICAL BULLETIN. Synthetic Turf Athletic Field Drainage Design Assistance

WinSLAMM v Program Modifications Final, 12/12/17

IBS Site Drainage: Senior Design Project

DIVISION 5 STORM DRAINAGE CRITERIA

Chapter Introduction. 5.2 Computational Standard Methods HYDROLOGY

LAKE COUNTY HYDROLOGY DESIGN STANDARDS

HYDROLOGY STUDY PREPARED FOR: MARKHAM PERRIS LLC 302 WEST FIFTH STREET, SUITE 103 SAN PEDRO, CA (310) FOR THE PROJECT:

Module 3: Rainfall and Hydrology for Construction Site Erosion Control

January 20, Nate Hatleback Project Manager, City of Thornton Development Engineering 9500 Civic Center Drive Thornton, CO (303)

Applying the Water Quality Volume

Facilities Development Manual

HYDROLOGY WORKSHEET 1 PRECIPITATION

SECTION 4 STORM DRAINAGE

INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN 40 C.F.R. PART PLANT YATES ASH POND 3 (AP-3) GEORGIA POWER COMPANY

STORMWATER HYDROLOGY

November 21, City of Thornton 9500 Civic Center Drive Thornton, CO (303) RE: Maverik Thornton, CO - Drainage Report

Introduction to Hydrology, Part 2. Notes, Handouts

Water Resources Management Plan

COON CREEK WATERSHED DISTRICT PERMIT REVIEW. Spring Lake Park Schools Westwood Middle School st Avenue NE, Spring Lake Park, MN 55432

iswm TM Technical Manual Hydrology:

Particulate Transport in Grass Swales

Module 3 and Module 4 Watershed Analysis and RUSLE Calculation. Noboru Togawa. Presented to: Dr. Pitt Construction Site Erosion Control

Use of IDF Curves Design of a roof drainage system

Analysis and Simulation of Drainage Capacity of Urban Pipe Network

Hydrology Study. Ascension Heights Subdivision Ascension Drive at Bel Aire Road San Mateo, California (Unincorporated)

La Riereta Catchment Sant Boi de Llobregat

Sump Pumps Office procedures for the Drainage & Grading section

Table of Contents CHAPTER. Chapter 2 Hydrologic Analysis. 2.1 Estimating Runoff

GIS Enabled Automated Culvert Design

Wastewater Collection System

RE: Final Drainage Letter: Northwest Aurora Alley Improvements 2016

Remediation and Treatment Technology Development and Support for DOE Oak Ridge Office: XPSWMM Model Configuration

Appendix E.2 Preliminary Hydrology Report

APPENDIX K OPERATIONS AND FINAL COVER SURFACE WATER MANAGEMENT SYSTEM DESIGN

INITIAL RUN-ON AND RUN-OFF CONTROL PLAN 40 C.F.R. PART 257

Stormwater Treatment Measure Sizing and Design Considerations SMCWPPP C.3 Workshop June 21, 2017

Inflow Design Flood Control System Plan

Using Sanitary Sewer I/I Field Data to Calibrate a Storm Sewer Model

PRELIMINARY DRAINAGE STUDY REPORT ARBOR VILLAS

Design of Stormwater Wetlands

APPENDIX IV. APPROVED METHODS FOR QUANTIFYING HYDROLOGIC CONDITIONS OF CONCERN (NORTH ORANGE COUNTY)

APPENDIX J-3. Orcem Stormwater Management and Treatment Facilities Design Summary

2. DEFINITIONS. American Association of State Highway and Transportation Officials.

Chapter 25. Techniques Used in an Urban Watershed Planning Study Introduction. K. R. Avery andy. 0. LaBombard

The site slopes generally from the southwest to northeast at approximately 3.7 percent.

Preliminary Drainage Analysis

Transcription:

Storm Sewer Design Bob Pitt University of Alabama and Shirley Clark Penn State Harrisburg Major floods are dramatic and water flow routes must be recognized when minor drainage systems fail. These types of events are not directly addressed by typical storm drainage systems (the minor systems). A trailer is trapped under a bridge by floodwaters, Houston, TX. Photo by Mary Grove. 1

Siren lights on this submerged firetruck are still flashing on the East Loop at I-10. Photo by Paul Carrizales. An unidentified man on a jet ski passes submerged trucks on Interstate 10. Photo from Houston Chronicle. 2

Ky Calder takes advantage of a break in the rain Saturday morning to take his kayak for a glide down U.S. 59 near the Hazard street overpass. Dave Rossman special to the Houston Chronicle. Storm Drainage System Design Chin 2006 3

4

Chin 2006 5

Birmingham Intensity - Duration - Frequency (IDF) Curve Basic Application of Rational Formula: Determine 10-yr (10% probability of being exceeded in any one year) flows at inlets to pipes: Pipe AB: inlet tc = 6 min; i = 7.4 in/hr; Q = CiA = (0.3)(7.4 in/hr)(3.1 acres) = 6.9 cfs Pipe BC: inlet tc = 8 min vs. 6 +0.6 min, use 8 min; i = 6.6 in/hr; Q= [(3.1ac)(0.3)+(2.8ac)(0.4)] 6.6 in/hr = 13.5 cfs Pipe CD: inlet tc = 5 min vs. 6 + 0.6 + 0.5 vs. 8 + 0.5, use 8.5 min; i = 6.3 in/hr; Q = [(3.1ac)(0.3)+(2.8ac)(0.4)+(2.1ac)(0.35)] 6.3 in/hr = 17.5 cfs The travel times in the pipes can only be calculated after the pipe sizes are selected and the velocities at the design flows are determined. 6

Pat Avenue storm sewer example. 1000 1001 Pat Avenue is located in Birmingham, AL. It consists of three subcatchments, three junctions (nodes) and two conduits (pipes) in a residential area. The water collected during a rainstorm is discharged to a main sewer trunk. 7

Site Information Area (Acres) Pipe length Slope (ft/ft) Imperv. (%) 1001 1.07-0.084 54 1011 1.09 300 0.093 54 1021 1.43 300 0.072 54 Runoff Coefficients for the Rational Formula for Different Hydrologic Soil Groups (A, B, C, D) and Slope Ranges (from McCuen, Hydrologic Analysis and Design. Prentice-Hall, Inc. 1998) Land Use A B C D Residential Lot, ⅛ acre Residential Lot, ¼ acre Residential Lot, ⅓ acre Residential Lot, ½ acre Residential Lot, 1 acre 0 2% 2 6% 6%+ 0 2% 2 6% 6%+ 0 2% 2 6% 6%+ 0 2% 2 6% 6% + 0.25 a 0.28 0.31 0.27 0.30 0.35 0.30 0.33 0.38 0.33 0.36 0.42 0.33 b 0.37 0.40 0.35 0.39 0.44 0.38 0.42 0.49 0.41 0.45 0.54 0.22 0.26 0.29 0.24 0.29 0.33 0.27 0.31 0.36 0.30 0.34 0.40 0.30 0.34 0.37 0.33 0.37 0.42 0.36 0.40 0.47 0.38 0.42 0.52 0.19 0.23 0.26 0.22 0.26 0.30 0.25 0.29 0.34 0.28 0.32 0.39 0.28 0.32 0.35 0.30 0.35 0.39 0.33 0.38 0.45 0.36 0.40 0.50 0.16 0.20 0.24 0.19 0.23 0.28 0.22 0.27 0.32 0.26 0.30 0.37 0.25 0.29 0.32 0.28 0.32 0.36 0.31 0.35 0.42 0.34 0.38 0.48 0.14 0.19 0.22 0.17 0.21 0.26 0.20 0.25 0.31 0.24 0.29 0.35 0.22 0.26 0.29 0.2 0.28 0.34 0.28 0.32 0.40 0.31 0.35 0.46 Subcatchment Commercial 0.71 0.71 0.72 0.71 0.72 0.72 0.72 0.72 0.72 0.72 0.72 0.72 0.88 0.88 0.89 0.89 0.89 0.89 0.89 0.89 0.90 0.89 0.89 0.90 a Runoff coefficients for storm recurrence intervals less than 25 years. b Runoff coefficients for storm recurrence intervals of 25 years or longer. 8

Example of Rational Method Calculation for Area 1001 Drainage Area (assume: 10-year storm because street is a minor urban street and not a collector street) Drainage Area: 1.07 acres Watershed Slope: 0.084 Hydrologic Soil Group C (assume/look up) Land Use Description: ½ acre lots Time of Concentration: 10 minutes Using T c = 10 minutes, i = 6.4 in/hr for 10-year storm Using ½-acre lot size, 6+% slope, C soil, C = 0.32 Peak Discharge = Q p = CiA Q p = (0.32)(6.4 in/hr)(1.07 acres) = 2.19 cfs Detailed Site Information Subcatchm ent Area (Acres) Slope (ft/ft) Rational C Inlet Tc (min) Travel time in pipe (min) Total Tc (min) Intensity (in/hr) Total Q at bottom of area (cfs) 1001 1.07 0.084 0.32 10.0-10.0 6.4 2.19 1011 1.09 0.093 0.32 10.0 0.5 10.5 6.2 4.29 1021 1.43 0.072 0.32 10.0 0.5 11.0 6.1 7.25 Tc gets larger and intensity gets smaller as the total drainage area increases 9

Conduit Information Conduit Shape Slope Length Manning s n 1000 Circular 0.073 300 0.013 1001 Circular 0.053 300 0.013 Manning s Equation Diameter of a Pipe Flowing Full Using Manning s Equation for Flow These equations are for US Customary units! Use cfs for Q, and ft for D. Without the 1.49 in the denominator of the last expression, SI units can be used: m 3 /sec for Q and m for D. 1.49 2 D Q D n 4 4 nq 1.49S 1/ 2 4nQ 1.49 S 1/ 2 4nQ 1/ 1.49 S 5 / 3 4 nq 1/ 1.49 S 5 / 3 4 nq 1/ 1.49 S 2 D D 4 4 2 2 2 D D 4 D 4 D 2 3 / 8 8 / 3 2 / 3 8 / 3 D 2 / 3 2 / 3 S 2 / 3 1/ 2 10

Storm Sewer Calculations Conduit Shape Slope Length Manning s n Total Q at end of pipe (cfs) 1000 Circular 0.073 300 0.013 2.19 1001 Circular 0.053 300 0.013 4.29 Conduit Q (cfs) Calculated D Actual D Regulated D Q full (cfs) 1000 2.19 0.573 0.667 1.5 28.4 1001 4.29 0.792 0.833 1.5 24.2 At outlet 7.25 0.958 1 1.5 24.2 Sewers Flowing Partly Full From: Metcalf and Eddy, Inc. and George Tchobanoglous. Wastewater Engineering: Collection and Pumping of Wastewater. McGraw-Hill, Inc. 1981. 11

Storm Sewer Calculations Conduit Q (cfs) Min. required pipe size Q full (cfs) Q/Q full d/d 1000 2.19 1.5 28.4 0.077 0.19 1001 4.29 1.5 24.2 0.18 0.29 At outlet 7.25 1.5 24.2 0.30 0.38 Conduit V/V full V full (ft/sec) V at peak flow (ft/sec) Travel time in pipe (min) 1000 0.59 16.1 9.5 0.5 1001 0.76 13.7 10.4 0.5 At outlet 0.90 13.7 12.3 - Pipe Sizes Minimum size 12-18 inches In many locations, the minimum size of a storm sewer pipe is regulated 12

Velocities Minimum velocity of 2.0 ft/sec (0.6 m/sec) with flow at ½ full or full depth Maximum average velocities of 10-12 ft/sec (2.5-3.0 m/sec) at design depth of flow Minimum and maximum velocities may be specified in state and local standards Slopes Sewers with flat slopes may be required to avoid excessive excavation where surface slopes are flat or the changes in elevation are small. In such cases, the sewer sizes and slopes should be designed so that the velocity of flow will increase progressively, or at least will be steady throughout the length of the sewer. 13

Getting Started with Storm and Sanitary Drainage Analysis using SWMM5 (Beta-E 01/23/04) The model can be downloaded by going to the EPA web site: http://www.epa.gov/ednnrmrl/swmm/ PAT Avenue subcatchments, joints and conduits (in this example, another link, 1003, was created to allow all subwatershed flows to be combined before the outfall junction, now 103). 14

Pat Avenue Subcatchment information: Subcatch ment Area (Acres) Width Slope (ft/ft) Percentage imperviousness n Manning impervious n Manning pervious 1001 1.067 98.3 0.084 54 0.040 0.410 1011 1.087 74.5 0.093 54 0.040 0.410 1021 1.431 109.0 0.072 54 0.040 0.410 Subcatchment Horton maximum infiltration rate (in/hr) Horton minimum infiltration rate (in/hr) Horton decay coefficient (1/sec) Horton recovery coefficient (fraction) Max. volume (inches) 1001 1 0.1 0.002 0.001 0 1011 1 0.1 0.002 0.001 0 1021 1 0.1 0.002 0.001 0 Pat Avenue Junction Information: Junction Invert Elevation Maximum Depth Initial Depth Surcharge Depth Ponded Area (ft²) 100 791 10 0 0 0 101 769 10 0 0 0 102 753 10 0 0 0 103 (Outfall) 745 n/a 0 0 0 15

Pat Avenue Conduit Information: Conduit Shape Diameter Length n Manning Inlet invert height offset 1000 Circular 1 300 0.013 0.5 1001 Circular 1 300 0.013 0.5 1003 Circular 1 100 0.013 0.5 Conduit Outlet invert height offset Initial flow (cfs) Entry loss coefficient Exit loss coefficient Average loss coefficient 1000 0.5 0 0 0 0 1001 0.5 0 0 0 0 1003 0.5 0 0 0 0 300 ft 801 ft 300 ft 779 ft 763 ft 10 ft D = 1ft n = 0.013 10 ft D = 1ft n = 0.013 outfall 16

17

18

19

20

21

22

Hello World Pat Avenue Sanitary Drainage Design Example Junction (Node) Area Served (ac) # Apt. Buildings Population (32 people / building) Water Use (150 gal / day) Daily Wastewater Flow (90% of water used) Sewage (cfs) 200 0.98 3 96 14400 12960 0.020 201 1.63 5 160 24000 21600 0.033 202 2.18 6 192 28800 25920 0.040 203 2.00 4 128 19200 17280 0.027 23

Junction Invert Elevation Maximum Depth Initial Depth Surcharge Depth Ponded Area (ft²) 200 807 13 0 0 0 201 788 13 0 0 0 202 766 13 0 0 0 203 (Outfall) 750 n/a 0 0 0 Conduit Shape Diameter Length n Manning Inlet invert height offset 2000 Circular 1 200 0.013 0.5 2001 Circular 1 300 0.013 0.5 2002 Circular 1 300 0.013 0.5 Conduit Outlet invert height offset Initial flow (cfs) Entry loss coefficient Exit loss coefficient Average loss coefficient 2000 0.5 0 0 0 0 2001 0.5 0 0 0 0 2002 0.5 0 0 0 0 24

25

Surcharged 1 ft. pipes Adequate capacity after enlarging pipes 2001 and 2002 to 1.5 ft in diameter 26