THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

Similar documents
POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE

DATA SHEET MS2500_EN-IT_DS006REV14

DATA SHEET MS2500_EN-IT_DS006REV17

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

FLOMID FX Electromagnetic Flowmeter

ALTOFLUX IFS 4000/4005

SENSOR MUT1000EL. Electromagnetic flowmeter. The wafer electromagnetic flowmeter DS120-2-ENG

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

ISI Marked Class-A & Class-B Water Meters as per IS: 779 / 1994 Conforming to ISO 4064 Standard for Cold Water Meters

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

SITRANS P measuring instruments for pressure

Flow Measurement SITRANS F M

Rosemount 405 Compact Primary Element

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

OPTIMASS 7400 Technical Datasheet

Keystone swing type wafer check valve Figure 86

Float Flow Meters series NF

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Battery-Powered Magnetic Flow Meter

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Battery-Powered Magnetic Flow Meter

VESSEL & REACTOR VALVES. VR Series RISING DISC PROCESS VALVES. Sold by: G&W Industrial Sales

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

VARIABLE AREA FLOWMETER EASYFLOW.

Triple offset valve with metallic seat for High performance. Class 300: 6 to 36 (DN 150 to 900) Design in accordance with EN and ASME B16-34

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240

VESSEL & REACTOR VALVES. VD Series DISC VALVES PROCESS VALVES

Thermometer in stainless steel with vertical stem in stainless steel

DeltaMass MT Series Mass Flow & Density Sensor

Immersion Assembly for ph and Redox Sensors DipFit P CPA 140

METAL & DUAL SEATED PISTON VALVES

DMH. Magnetic Inductive Flowmeter. for conductive fluids

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

VLM10 In-line Vortex Mass Flow Meter

Diaphragm seal with flange connection With internal diaphragm Model

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Flanged chemical seals series D

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

Pressure and temperature transmitters ATM/T

CIRRUS MAGNETIC FLOW METER CLA1-MF

OPTIMASS 7400 Technical Datasheet

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Coriolis Mass Flow Meter

Regulating valves REG 6-65, REG-SS 15-40

3.2 HP 114 HIGH PERFORMANCE BUTTERFLY VALVE HP 114 TECHNICAL DATA FEATURES GENERAL APPLICATIONS

Coriolis Mass Flowmeter serving thousands of worldwide applications

Level measurement CleverLevel LBFS Point level detection

PanaFlow MV82. Insertion Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Differential pressure

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

Level measurement CleverLevel LBFS Point level detection

kyfor Your Utility Heating and Cooling

Materials : Carbon steel or Stainless steel MERXTRADE BV.

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

M15 ISO Ball Valve DN¼" to DN2½"

Compact CATALOG. Performance. Safety Relief Valves Series 437 Series 459. The-Safety-Valve.com

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

Rosemount 405 Compact Orifice Primary Element

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Datasheet Rev.1 Feb 2016 Orifice plate multi-holes

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

METAL SEATED BUTTERFLY VALVES

Spare List SPL/266XXX-EN Rev. B. Models 266XXX spare parts list. 2600T Series Pressure Transmitters Engineered solutions for all applications

M7100 Pressure Transducer

Flow Through Toroidal Conductivity Sensor

4-Beam-Turbidity Meter ITM-4

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

3.3 HP 111- E HIGH-PERFORMANCE BUTTERFLY VALVE HP 111- E TECHNICAL DATA

Diaphragm seal with threaded connection Threaded design Model

Thermometer in stainless steel with adjustable stem in stainless steel. Compression fitting for direct mounting or mounting in separate thermowell

EN Size : Ends : Min Temperature : Max Temperature : Materials : Brass body

3.3 HP 111- E HIGH-PERFORMANCE BUTTERFLY VALVE HP 111- E. TECHNICAL DATA

Diaphragm pressure gauge per EN 837-3,

ON-OFF free flow valves Series MVMFL/BW

M21Si ISO and M21Vi ISO Ball Valves DN15 to DN150

M21Si ISO and M21Vi ISO Ball Valves DN15 to DN150

Continuous Level Sensor CONDURIX 31.1

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

KLINGER BALLOSTAR KHA

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume

Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication

CombiTemp TCR6 Standard RTD temperature sensor

Datasheet Rev.4 Jan 2015 Orifice plate - Overview

Electromagnetic Flowmeter

Transcription:

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site: www.isomag.eu

INDEX TECHNICAL DATA... 3 OVERALL FEATURES... 3 STANDARD FEATURES... 3 OPTIONAL FEATURES... 3 OVERALL DIMENSIONS... 4 GAS/NPT WITHOUT LINING... 4 GAS/NPT WITH LINING... 5 FLANGED WITHOUT LINING... 6 FLANGED WITH PTFE LINING... 7 SANITARY CLAMP... 8 SANITARY DIN/SMS... 9 INSTALLATION RECOMMENDATIONS... 10 SENSOR GROUNDING... 11 SEPARATE VERSION... 12 PRESSURE LOSS CALCULATION (CONES 8 ANGLES)... 13 HOW TO ORDER... 14 The Manufacturer Guarantee Only English Text Page 2 of 14 MS501_EN_DS022REV04_IS

T E C H N I C A L D A T A OVERALL FEATURES Nominal diameter 3 20 Minimum conductivity 5 S/cm Humidity Range 0 100% (IP 67) Accuracy See relevant converter data sheet CE Certification Yes Body material AISI 304 Nominal pressure 1600 kpa Process connections STANDARD FEATURES Threaded UNI 338 Threaded NTP Flanged UNI 2278 Flanged ANSI 150 Sanitary DIN 11851 Clamp ISO 2852 Clamp BS 4825 SMS Version protection rating Compact IP67 Connections material AISI 316 Lining material PTFE Gasket material FPM Liquid temperature -20 C 100 C comp. (130 C only with ML4F-1) -20 C 130 C separate Vacuum resistance 20 Kpa absolute at 100 C Electrodes material AISI 316L Hastelloy C Platinum rhodium Titanium Tantalum OPTIONAL FEATURES (CHECK FOR MORE DETAILS HOW TO ORDER ON LAST PAGE) Body material Stainless steel 316 Gasket material EPDM Nominal pressure 4000kPa Process connection Others on request Connections material AISI 304 with lining in PTFE Other on request Electrodes material Others On request Version protection rating Separate (max 20m) IP 68 Separate (max 500m) with pre-amp IP 67 (IP 68 optional) The Manufacturer Guarantee Only English Text Page 3 of 14 MS501_EN_DS022REV04_IS

25 (1") 76 (3") 170 (6.7") O V E R A L L D I M E N S I O N S GAS/NPT WITHOUT LINING 80 (3.15") 128 (5.04) 70 (2.76") GAS/NPT (STAINLESS STEEL WITHOUT LINING) DIMENSIONS mm (inches) FITTINGS 1/4" 3/8" 1/2" 3/4" 1" The Manufacturer Guarantee Only English Text Page 4 of 14 MS501_EN_DS022REV04_IS

25 (1") 76 (3") 170 (6.7") GAS/NPT WITH LINING 80 (3.15") 128 (5.04) 70 (2.76") GAS/NPT (STAINLESS STEEL LINING) DIMENSIONS mm (inches) FITTINGS 1/2" 1/2" 3/4" 1" 1"1/4 The Manufacturer Guarantee Only English Text Page 5 of 14 MS501_EN_DS022REV04_IS

25 (1") D H FLANGED WITHOUT LINING 80 (3.15") 200 (7.87) 70 (2.76") FLANGE UNI (STAINLESS STEEL WITHOUT LINING) DIMENSIONS mm (inches) D 90 (3.54) 90 (3.54) 90 (3.54) 95 (3.74) 105 (4.13) H 183 (7.20) 183 (7.20) 183 (7.20) 186 (7.30) 191 (7.5) FITTINGS 10 10 10 15 20 FLANGE ANSI (STAINLESS STEEL WITHOUT LINING) DIMENSIONS mm (inches) 98.4 D 88.9 (3.5) 88.9 (3.5) 88.9 (3.5) 88.9 (3.5) (3.87) 183 183 H 183 (7.20) 183 (7.20) 188 (7.37) (7.20) (7.20) FITTINGS 1/2" 1/2" 1/2" 1/2" 3/4" The Manufacturer Guarantee Only English Text Page 6 of 14 MS501_EN_DS022REV04_IS

25 (1") D H FLANGED WITH PTFE LINING 80 (3.15") 200 (7.87) 70 (2.76") UNI FLANGE (PTFE LINING) DIMENSIONS mm (inches) D 90 (3.54) 90 (3.54) 90 (3.54) 95 (3.74) 105 (4.13) H 183 (7.20) 183 (7.20) 183 (7.20) 186 (7.30) 191 (7.5) FITTINGS 10 10 10 15 20 ANSI FLANGE (PTFE LINING) DIMENSIONS mm (inches) D 88.9 (3.5) 88.9 (3.5) 88.9 (3.5) 88.9 (3.5) 98.4 (3.87) H 183 (7.20) 183 (7.20) 183 (7.20) 183 (7.20) 188 (7.37) FITTINGS 1/2" 1/2" 1/2" 1/2" 3/4" The Manufacturer Guarantee Only English Text Page 7 of 14 MS501_EN_DS022REV04_IS

25 (1") I F 76 (3") 170 (6.7") SANITARY CLAMP 80 (3.15") 128 (5.04") 70 (2.76") CLAMP ISO 2852 DIMENSIONS mm (inches) I 12.7(0.5) 12.7(0.5) 12.7(0.5) 17.2(0.68) 21.3 (0.84) F 34 (1.34) 34 (1.34) 34 (1.34) 34 (1.34) 34 (1.34) CLAMP BS 4825 DIMENSIONS mm (inches) I 9.5 (0.37) 9.5 (0.37) 9.5 (0.37) 15.85 (0.62) 22.2 (0.87) F 25.4 (1) 25.4 (1) 25.4 (1) 25.4 (1) 50.5 (1.99) The Manufacturer Guarantee Only English Text Page 8 of 14 MS501_EN_DS022REV04_IS

25 (1") 76 (3") 170 (6.7") SANITARY DIN/SMS 80 (3.15") 128 (5.04") 70 (2.76") DIN 11851 DIMENSIONS FITTINGS 10 10 10 15 20 SMS DIMENSIONS 10 (3/8) 15 (1/2") 20 (3/4") FITTINGS 25 25 25 The Manufacturer Guarantee Only English Text Page 9 of 14 MS501_EN_DS022REV04_IS

I N S T A L L A T I O N R E C O M M E N D A T I O N S In vertical installations an ascending flow is preferable. For vertical installations with descending flow direction contact the manufacturer For installations in long pipe lines, please use anti vibration joints ANTIVIBRATION LONG PIPING Avoid a partially empty pipe, during operation the pipe must be either completely full of liquid or completely empty Install the sensor away from bends and hydraulic accessoriesds and hydraulic accessories 3 X 2 X Avoid positioning flange and counter flanges by tigthening the nuts. PIPE CONNECTION NUT NUT PIPE CONNECTION SENSOR'S FITTING SENSOR'S FITTING The Manufacturer Guarantee Only English Text Page 10 of 14 MS501_EN_DS022REV04_IS

S E N S O R G R O U N D I N G METALLIC PIPE THREADED SENSOR FLANGED SENSOR INSULATED PIPE SEALING GASKET METALLIC RING If the sensor has to be installed in a pipe made of an insulating material, the following are necessary: - Inserting two metallic rings between the sensor flanges and the pipe line counter flanges or: - Using a sensor with the additional grounding electrode PIPE WITH CATHODIC PROTECTION SEALING GASKET If the sensor has to be installed in the pipe with a cathodic protection, the following are necessary: - using insulating bushes to isolate the bolts METALLIC RING - Metallic grounding rings should be provided to ground the liquid using insulating gaskets between the rings INSULATING BUSH The Manufacturer Guarantee Only English Text Page 11 of 14 MS501_EN_DS022REV04_IS

CONDUCTIVITY (µs/cm) S E P A R A T E V E R S I O N 200 150 100 ML110 ML210/ML211/ML212 50 5 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 CABLES LENGHT (m) Notes: It is recommended to install the connection cables away from, or protect against sources of electromagnetic noise. The minimum conductivity of the liquid medium to ensure correct functionality of the empty pipe detection is 20 µs/cm The Manufacturer Guarantee Only English Text Page 12 of 14 MS501_EN_DS022REV04_IS

P R E S S U R E L O S S C A L C U L A T I O N ( C O N E S 8 A N G L E S ) d D 8 8 Where: p 0.10 0.20 d D 2 1 2 d D 4 2 u 2 p = Pressure loss in [Pa] = Fluid density [kg/m 3 ] typical value d = sensor diameter [m] 1000[ kg/ m D = pipe diameter (greater than sensor diameter) [m] u = Mean flow velocity in sensor diameter [m/s] 3 ] Calculation examples p [mbar] u d/d 1 [m/s] 2 [m/s] 3 [m/s] 4 [m/s] 5 [m/s] 6 [m/s] 7 [m/s] 8 [m/s] 0.5 1.1 4.3 9.6 17.0 26.6 38.3 52.1 68.0 0.6 0.9 3.6 8.2 14.6 22.7 32.7 44.6 58.2 0.7 0.8 3.0 6.8 12.2 19.0 27.4 37.2 48.6 0.8 0.6 2.5 5.7 10.1 15.7 22.7 30.9 40.3 0.9 0.5 2.1 4.8 8.6 13.4 19.3 26.3 34.3 Note : 3 1000[ kg/ m ] as goodness approximation of water density in common use. Inner diameter of sensor is used for d, express in meters. Indeed pressure loss equation is dimensionally correct in [Pa]. The equation results in table are show in [mbar]. The Manufacturer Guarantee Only English Text Page 13 of 14 MS501_EN_DS022REV04_IS

H O W T O O R D E R CODE Nominal Diameter / Lining / Maximum temperature / Measuring range EXAMPLE T03 3 ( 1/8 "), PTFE lining, measuring range 0.. 10,4 / 0...259 l/h T06 6 ( 1/4 "), PTFE lining, measuring range 0...41,4/0...1036 l/h T03 T10 10 (3/8 "), PTFE lining, measuring range 0..115.2/0...2880 l/h T15 15 (1/2 "), PTFE lining, measuring range 0.. 259.2/0...6480 l/h T20 20 (3/4 "), PTFE lining, measuring range 0.. 460.8/0...11520 l/h Gasket material ( internal tightness ) 1 O-Ring : FKM 2 O-Ring : Epdm 1 4 O-Ring : FFKM 9 Gasket material: to be specified Nominal Pressure A Nominal pressure: PN16 A B Nominal pressure: PN40 Z Nominal pressure: others on request Process connection type 1 Male threated UNI338 ( FOR THE DIMENSIONS CONSULT THE OVERALL DIMENSIONS DRAWING) 2 Male threated NPT( FOR THE DIMENSIONS CONSULT THE OVERALL DIMENSION DRAWING) 3 Clamp connection, ISO2852 4 DIN11851-852 sanitary connection 5 SMS connection (only for 10,15,20) 1 6 UNI2278 flange connection ( FOR THE DIMENSIONS CONSULT THE OVERALL DIMENSION DRAWING) 7 ANSI 150 flange connection( FOR THE DIMENSIONS CONSULT THE OVERALL DIMENSION DRAWING) 8 Clamp connection, BS 4825 9 JIS flanges ( 10 k ) 0 Connection: other Connection material A Connection material: AISI316 A C Connection material: AISI304, PTFE internal lining (only connection 1-2-6-7) 9 Connection material: to be specified Number and electrodes material 1 n. 2 measure electrodes in AISI316 4 n. 4 (2 measure + 2 for ground) electrodes in Hastelloy C 5 n. 4 (2 measure + 2 for ground) electrodes in Titanium 1 6 n. 4 (2 measure + 2 for ground) electrodes in Tantalum 7 n. 4 (2 measure +21 for ground) electrodes in Platinum 0 Electrode material: to be specified Execution / Protection rate A Compact execution, IP67 protection rate Separate execution maximum length 10 m (20m, see note 1), remember to added the cables, protection rate IP68 (standing B immersion with 1,5 m of head water) C Separate execution (in Carbon Steel), with preamplifier (maximum length 500 m.), remember to added,protection rate IP67 D Separate execution (in AISI304), with preamplifier (maximum length 500 m.), remember to added, protection rate IP67 Execution with length and position of the neck of the Sensor to define according draw. G006 (valid for A-B-C-D versions, add E the relative COST) A F Execution separate with N 2 connectors IP 68 suitable for fast cable connections ( max 20 m-add THE COST ) G Execution separate with N 1 connectors IP 68 suitable for fast cable connections ( max 20 m-add THE COST ) Execution separate with N 1 connectors IP 68 suitable for fast cable connections TO PRAMPLIFIRE IN CARBON STEEL H VERSION (DEFINE THE CABLE LENGHT MAX 500 m-add THE COST ) Execution separate with N 1 connectors IP 68 suitable for fast cable connections TO PRAMPLIFIRE IN AISI 304 I VERSION (DEFINE THE CABLE LENGHT MAX 500 m-add THE COST ) M Compact execution, IP67 protection rate, with the possibility to turn the converter of 90 MS501-T03-1A1A1A (Complete code example for order) The manufacturer reserves the right to make design improvements without notice. Production / stock 35044 Montagnana PD Via Piemonte, n 2