ENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1

Similar documents
ENGINEERING SPECIFICATION PULTRUDED FIBERGLASS GRATING SAFE-T-SPAN HIGH LOAD CAPACITY (47% OPEN AREA) VINYL ESTER. January 24,

ENGINEERING SPECIFICATION

ENGINEERING SPECIFICATION FIBERGRATE 1 INCH DEEP MICRO-MESH MOLDED GRATING SECTION 06610

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING

ENGINEERING SPECIFICATION FIBERGRATE 62% OPEN AREA/ADA COMPLIANT MOLDED GRATING. January 5,

ENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610

ENGINEERING SPECIFICATION PULTRUDED DYNADECK INTERLOCKING FLOORING

ENGINEERING SPECIFICATION PULTRUDED HIGH LOAD CAPACITY (HI) SAFE-T-SPAN FIBERGLASS GRATING. January 24,

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. March 16,

ENGINEERING SPECIFICATION NON-MAGNETIC RAISED FLOOR SYSTEM FOR MRI ROOM APPLICATIONS

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

SECTION FRP GRATING, HANDRAIL, AND SUPPORTS

GLASSFIBER REINFORCED PLASTICS (GRP) MOULDED AND PULTRUDED GRATING

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS GUARDRAIL AND HANDRAIL. January 24,

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS GUARDRAIL AND HANDRAIL. January 24,

Re-Grate Pultruded Grating

PRODUCT SPECIFICATIONS PULTRUDED GRATING AND TREADS SECTION PART 1 GENERAL

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Pultruded Grating/Treads and Fabrications REVISED

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Molded Grating and Treads Products and Fabrications REVISED 11.

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Architectural Decking panels and Fabrications REVISED 11.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Pultruded Grating. ADDED SAFETY - durable grit surface, permanently bonded, and baked to the grating surface, for a safe, slip-resistant walkway.

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Hollow Core Building Panels Products and Fabrications REVISED 11.

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

Dynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.

PULTRUDED FIBERGLASS GRATING

FRP Floor Panels Standard Specification

PROForms. Specifications SECTION FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS

Dynarail Safety Ladders & Cages

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED

SECTION ARCHITECTURAL FIBERGLASS

SECTION ARCHITECTURAL FIBERGLASS

SECTION FIBERGLASS REINFORCED PLASTIC (FRP) DOORS AND FIBERGLASS RESIN TRANSFER MOLDED DOOR FRAMES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

EXCLUSIVELY MOLDED FIBERGLASS GRATING

GRATING PRODUCTS. PROGrid and PROGrate

FRP REBAR: MDOT APPROVED

SECTION 16 FIBERGLASS FLOORING AND DECKING SYSTEMS

Premium Fiberglass Products. QUALITY SPEED RELIABILITY Molded - Pultruded - Treads - Structurals - Ladders - Handrails

FIBERGLASS REINFORCED PLASTIC (FRP) LAUNDER COVERS

Installation Instructions

Decorative Fiberglass Reinforced Wall Panels

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

SECTION ALUMINUM HANDRAIL SYSTEMS

Installation Instructions

Phenolic Exterior Wall Cladding

Powell. Sodium Hypochlorite Fiberglass Reinforced Plastic (FRP) Storage Tanks

CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE

SECTION FIBERGLASS WEIRS AND BAFFLES

FRP Baffle Wall Standard Specification-Section 11350

EUROGRATE FIBERGLASS PULTRUDED GRATINGS

FRP Classic TM Cast Stone Fiberglass Fabrications Architectural Specification

Tel: Fax:

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

MODEL CP 12 HURRICANE SINGLE FBC +/- 70 psf CERTIFIED DOOR (Not for HVHZ) MANUFACTURED IN THE UNITED STATES OF AMERICA

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

FIBERGLASS GRATING. and PULTRUDED GRATING

SECTION 415 REINFORCING FOR CONCRETE

Thickness Mesh Size Panel Size Color Resin Type

SECTION PRECAST CONCRETE COVER SYSTEM

WEIR PLATES & SCUM BAFFLES

PRODUCT SPECIFICATIONS

Dynaform Fiberglass Structural Shapes

Product Specifications

FIBERGLASS WET WELLS

Guidelines for the Engineer & Designer

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION STRUCTURE MOUNT RAILING SYSTEM

SECTION PRE-ENGINEERED METAL BUILDING

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

Dynarail Guardrail, Handrail & Ladder

PHENOLIC FIRE INTEGRITY COMPOSITE GRATING U.S. COAST GUARD APPROVED

Pedestals for Molded Grating

First Class Building Products, Inc.


FIBERGLASS DECKING SYSTEMS

Dynaform Structural Shapes

SECTION STONE WALL FACINGS

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

Dynaform Structural Shapes

SEISMIC RESTRAINT SYSTEM

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Fiberstrut Parts Catalogue

Ultra Aluminum Fence, Rail & Gate Specifications

SAMPLE SPECIFICATIONS FOR PREFABRICATED FRP LIFT STATIONS

SECTION 1043 FENCE MATERIAL

SECTION DETECTABLE GUIDE TACTILES

SECTION ENTRANCE FLOOR GRILLES SPECIFICATIONS

TAMDID PIPES GRP MANHOLE BROCHURE

Expansion Joint Covers (079513)

MODEL CP 10 MOLDED LITE HURRICANE DOOR MANUFACTURED IN THE UNITED STATES OF AMERICA

Expansion Joint Covers

Special Provision No. 999S02 March 2018 REQUIREMENTS FOR GLASS FIBRE REINFORCED POLYMER (GFRP) REINFORCING BAR

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Special Provision No. 999S02 June 2017 CONSTRUCTION SPECIFICATION FOR GLASS FIBRE REINFORCED POLYMER (GFRP) REINFORCING BAR TABLE OF CONTENTS

SECTION FLAT WALK-ON TYPE ALGAE CONTROL/LAUNDER COVERS

January 1, 2012 AVAILABILITY LIST

Transcription:

ENGINEERING SPECIFICATION PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC 1

PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED PEDESTRIAN GRATING A. The CONTRACTOR shall furnish, fabricate (where necessary), and install all fiberglass reinforced plastic (FRP) items, with all appurtenances, accessories and incidentals necessary to produce a complete, operable and serviceable installation as shown on the Contract Drawings and as specified herein, and in accordance with the requirements of the Contract Documents. 1.2 REFERENCES A. The publications listed below (latest revision applicable) form a part of this specification to the extent referenced herein. The publications are referred to within the text by the designation only. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) Test Methods: ASTM D 635 Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position ASTM D 732 Shear Strength of Plastics by Punch Tool ASTM E 84 Surface Burning Characteristics of Building Materials 1.3 CONTRACTOR SUBMITTALS A. The CONTRACTOR shall furnish shop drawings of all fabricated gratings and accessories in accordance with the provisions of this Section. B. The CONTRACTOR shall furnish manufacturer's shop drawings clearly showing material sizes, types, styles, part or catalog numbers, complete details for the fabrication of and erection of components including, but not limited to, location, lengths, type and sizes of fasteners, clip angles, member sizes, and connection details. 2

C. The CONTRACTOR shall submit the manufacturer s published literature including structural design data, structural properties data, grating load/deflection tables, corrosion resistance tables, certificates of compliance, test reports as applicable, concrete anchor systems and their allowable load tables, and design calculations for systems not sized or designed in the contract documents. D. The CONTRACTOR may be requested to submit sample pieces of each item specified herein for acceptance by the ENGINEER as to quality and color. Sample pieces shall be manufactured by the method to be used in the WORK. 1.4 QUALITY ASSURANCE A. All items to be provided under this Section shall be furnished only by manufacturers having a minimum of ten (10) years experience in the design and manufacture of similar products and systems. Additionally, if requested, a record of at least five (5) previous, separate, similar successful installations in the last five (5) years shall be provided. B. Manufacturer shall offer a 3 year limited warranty on all FRP products against defects in materials and workmanship. C. Manufacturer shall be certified to the ISO 9001-2000 standard. D. Manufacturer shall provide proof of certification from at least two other quality assurance programs for it s facilities or products (UL, DNV, ABS, USCG, AARR). 1.5 PRODUCT DELIVERY AND STORAGE A. Delivery of Materials: Manufactured materials shall be delivered in original, unbroken pallets, packages, containers, or bundles bearing the label of the manufacturer. Adhesives, resins and their catalysts and hardeners shall be crated or boxed separately and noted as such to facilitate their movement to a dry indoor storage facility. B. Storage of Products: All materials shall be carefully handled to prevent them from abrasion, cracking, chipping, twisting, other deformations, and other types of damage. Store items in an enclosed area and free from contact with soil and water. Store adhesives, resins and their catalysts and hardeners in dry indoor storage facilities between 70 and 85 degrees Fahrenheit (21 to 29 degrees Celsius) until they are required. PART 2 - PRODUCTS 3

2.1 MANUFACTURER A. Pultruded grating shall be Safe-T-Span as manufactured by: 2.2 GENERAL Fibergrate Composite Structures Inc. 5151 Belt Line Road, Suite 700 Dallas, Texas 75254-7028 USA (800) 527-4043 (972) 250-1530 Fax a. All FRP items furnished under this Section shall be composed of fiberglass reinforcement and resin in qualities, quantities, properties, arrangements and dimensions as necessary to meet the design requirements and dimensions as specified in the Contract Documents. b. Fiberglass reinforcement shall be a combination of continuous roving, continuous strand mat, and surfacing veil in sufficient quantities as needed by the application and/or physical properties required. c. Resins shall be {VINYL ESTER or ISOPHTHALIC - choose one} with chemical formulations as necessary to provide the corrosion resistance, strength and other physical properties as required. B. All finished surfaces of FRP items and fabrications shall be smooth, resin-rich, free of voids and without dry spots, cracks, crazes or unreinforced areas. All glass fibers shall be well covered with resin to protect against their exposure due to wear or weathering. C. All pultruded structural shapes shall be further protected from ultraviolet (UV) light with 1) integral UV inhibitors in the resin and 2) a synthetic surfacing veil to help produce a resin rich surface. D. All FRP products shall have a tested flame spread rating of 15 or less per ASTM E-84 Tunnel Test. Gratings shall also have a tested burn time of less than 30 seconds and an extent of burn rate of less than or equal to 10 millimeters per ASTM D635. E. All grating clips shall be manufactured of Type 316SS (stainless steel). 2.3 PULTRUDED GRATING A. Manufacture: Grating components shall be high strength and high stiffness pultruded elements having a maximum of 70% and a minimum of 60% glass content (by weight) of continuous roving and continuous strand mat fiberglass reinforcements. 4

The finished surface of the product shall be provided with a surfacing veil to provide a resin rich surface which improves corrosion resistance and resistance to ultraviolet degradation. Bearing bars shall be interlocked and epoxied in place with a two piece cross rod system to provide a mechanical and chemical lock. Cross rods should be below the walking surface of the grating. Gratings with cross rods that are flush with the walking surface are excluded. B. Non-slip surfacing: Grating shall be provided with a silica sand grit bonded and baked to the top surface of the finished grating product. C. Fire rating: Grating shall be fire retardant with a tested flame spread rating of 25 or less when tested in accordance with ASTM E 84. Manufacturer may be required to provide certification of ASTM E84 test on grating panels from an independent testing laboratory. Test data shall be from full scale testing of actual production grating, of the same type and material supplied on the project. Test data performed only on the base resin shall not be acceptable. D. Resin system: The resin system used in the manufacture of the grating shall be {VEFR, VINYL ESTER or ISOFR, ISOPHTHALIC - choose one}. Manufacturer may be required to submit corrosion data from tests performed on actual grating products in standard chemical environments. Corrosion resistance data of the base resin from the manufacturer is not a true indicator of grating corrosion resistance and shall not be accepted. E. Color: Light Gray F. Depth: 1" deep load bars with a tolerance of plus or minus 1/32". G. Mesh Configuration: 1.7" load bar spacing; 12" tie bar spacing on centers. Grating shall be SAFE-T-SPAN T1210V or T1210I as manufactured by Fibergrate Composite Structures Incorporated H. Load/Deflection: Grating shall meet manufacturers published safe recommended loadings with deflection not to exceed the following: Uniform distributed load over a 42" span: 50 pounds per square foot, with a maximum deflection of 0.11". I. Substitutions: Other products of equal strength, stiffness, corrosion resistance and overall quality may be submitted with the proper supporting data to the engineer for approval. 2.4 GRATING FABRICATION 5

A. Measurements: Grating supplied shall meet the minimum dimensional requirements as shown or specified. The Contractor shall provide and/or verify measurements in field for work fabricated to fit field conditions as required by grating manufacturer to complete the work. Determine correct size and locations of required holes or cutouts from field dimensions before grating fabrication. B. Layout: Each grating section shall be readily removable, except where indicated on drawings. Manufacturer to provide openings and holes where located on the contract drawings. Grating supports shall be provided at openings in the grating by contractor where necessary to meet load/deflection requirements specified herein. Grating openings which fit around protrusions (pipes, cables, machinery, etc.) shall be discontinuous at approximately the centerline of opening so each section of grating is readily removable. C. Sealing: All shop fabricated grating cuts shall be coated with vinyl ester resin to provide maximum corrosion resistance. All field fabricated grating cuts shall be coated similarly by the contractor in accordance with the manufacturer's instructions. D. Hardware: Type 316 stainless steel hold-down clips shall be provided and spaced at a maximum of four feet apart with a minimum of four per piece of grating, or as recommended by the manufacturer. PART 3 - EXECUTION 3.1 INSPECTION A. Shop inspection is authorized as required by the Owner and shall be at Owner's expense. The fabricator shall give ample notice to Contractor prior to the beginning of any fabrication work so that inspection may be provided. B. The grating shall be as free, as commercially possible, from visual defects such as foreign inclusions, delamination, blisters, resin burns, air bubbles and pits. 3.2 INSTALLATION A. Contractor shall install gratings in accordance with manufacturers assembly drawings. Lock grating panels securely in place with hold-down fasteners as specified herein. Field cut and drill fiberglass reinforced plastic products with carbide or diamond tipped bits and blades. Seal cut or drilled surfaces in accordance with manufacturer's instructions. Follow manufacturer's instructions when cutting or drilling fiberglass products or using resin products; provide adequate ventilation. 6