Roof & Gutter Ice/Snow Melting Design Guide

Similar documents
Nuheat WEATHER-READY ROOF & GUTTER DE - ICING SYSTEM. 13mm Self-Regulating Heating Cable. UV Resistant Polyolefin Outer Jacket

SnoTrace TM RGS TM Systems for Roof and Gutter Snow and Ice Melting

ROOF ICE MELT RIM SYSTEM

ASSOCIATED PRODUCTS. Roof Clips (50 ea) Downspout Hanger Bracket ALSO AVAILABLE FOR PIPES

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS

FAIL SAFE TEMPERATURE LIMIT - the cable cannot overheat and melt or damage temperature sensitive roof coatings.

SELF-REGULATING ROOF HEAT CABLE. Installation Guide WS-SRIM V2.0

SpeedTrace Roof & Gutter Pre-Assembled Self-Regulating Heating Cable

AMIGA. Installation Instructions

Installation Instructions Self-Regulating (sr) roof and gutter

SECTION HEAT TRACING FOR PLUMBING PIPING

SECTION HEAT TRACING FOR PLUMBING PIPING

Installation Manual. Self-regulating cable 20W/m (W20SR) TECHNICAL HELPLINE

De-Icing Cable for Roofs and Gutters

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Installation Instructions Mineral Insulated (M.I.)

EDGE-CUTTER. Aesthetically Pleasing Aluminum Channel Flashings Designed for Advance

Snowmelt Cable TECHNICAL HELPLINE

FLAT ROOF HEATING RIBBONS INSTALLATION INSTRUCTIONS

Installation Manual. Snowmelt Cable 25W/m (W25SM) TECHNICAL HELPLINE

Installation Guide Mesh Floor Heating System

HotShingleLOK TM

Installation Guide 3CWC Floor Heating Cable System This guide is valid for all our 3CWC floor heating cable systems.

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM UNDER METAL ROOFING

Accent Floor Heating. Tmat System Installation Manual. Floor heating system

Paladin Pre-Assembled Heating Cable Set for Roof and Gutter Applications

Snow/Ice Melt Heating Cable System Gutters & Roof Drains Installation Manual Nexans TXLP/1 Series Resistance Cables

SECTION SECONDARY UNIT SUBSTATIONS

Eradicating ice dams begins below the roof deck. by Maciek Rupar

Pre-Insulated Tubing Bundles

Outdoor Heating Applications Mats and cables

WarmAll. 119A Sir Wilfrid Laurier Saint-Basile-le-Grand, (Québec), J3N 1M2

Ice and snow melting Pavements, roads and ramps

electric snow melting mats

MESH FLOOR HEATING SYSTEMS INSTALLATION INSTRUCTIONS

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

WARM ALL. Installation Guide Mesh Floor Heating System

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Tepidus Wire Installation instructions for Electric Radiant Floor Heating INDEX

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

A Unique Heating System. ...for over 30 years. Can be operated with solar and wind power! Safe Efficient Maintenance-Free.

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

SECTION ROOF SPECIALTIES

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

UNITED COOPERATIVE SERVICES. SPECIFICATIONS FOR SELF-CONTAINED METER INSTALLATIONS August 2014

Installation Instructions

Installation Instructions Mineral Insulated (M.I.) Snow Melting Cable

SECTION ENCLOSED BUS ASSEMBLIES

Installation Guide. Ice and snow melting. Pavements, roads and ramps. Intelligent solutions with lasting effect. Visit DEVI.com

A Unique Heating System. ...for over 30 years. Can be operated with solar and wind power! Safe Efficient Maintenance-Free.

RaySol System INSTALLATION AND OPERATION MANUAL FOR FLOOR HEATING AND FREEZER FROST HEAVE PREVENTION SYSTEMS

DRAFT 9/13/12. Installation & Operation Instructions for Mineral Insulated Heating Cable Embedded Snow Melting Applications.

Bluethermal Underfloor Heating Mat

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

TECHNICAL SPECIFICATIONS

RESIDENTIAL QUICK REFERENCE

Installers Guide. Item

SERGE BARIL HEAT TRACING SYSTEMS MINERAL INSULATED SNOW MELTING CABLE INSTALLATION AND OPERATING INSTRUCTIONS

Building Permit Application

Installation Instructions Snow Melt Mats

SECTION ENCLOSED BUS ASSEMBLIES

Nuheat. WEATHER-READY MINERAL INSULATED SNOW MELT CABLE Mineral Insulated (MI) Snow Melt Cable Installation Guide

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013

Metal Retrofit Systems from Royalty Roofing

Installing the Sno-free Panel Eave System for New Roofs

Nuheat Mat Installation Manual Nuheat Electric Floor Heating System

MI Heating Cable System INSTALLATION AND OPERATION MANUAL FOR SURFACE SNOW MELTING

A. Section includes busway and fittings including plug-in units.

Heating cables in concrete Concrete > 3 cm

This specification describes the minimum requirements for industrial thermal insulation.

TYPICAL ROOF CONDITION LAYOUT

Proven effective year after year.

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

Western States 7/8 Corrugated

Utilities Industry. General Information. Products and Services APPLICATIONS

SECTION PART 1 GENERAL

QuickNet-RK QUICKNET AND CERAPRO HEATING CABLE REPAIR KIT INSTALLATION INSTRUCTIONS

CI/SfB (57.7) 2nd Edition. the warmth beneath your feet FREE NEXT DAY DELIVERY /0811

Table of contents. 03 Overview. 04 The Advantages. 06 The Products. 08 Series SN for new gutter application. 12 Series TP for existing gutters

Undertile Heating Mat Installation Manual

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

Specification Lightning Protection Systems

SECTION GROUNDING AND BONDING

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

4 POINT INSPECTION REPORT

Reflections After The Thaw Maine Water Utilities

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

Sheet Metal Flashing and Trim

Metal Roofing. The Devil is in the Details SSRLU3B. I LU/HSW Hour

GENERAL NOTES PEDERNALES ELECTRIC COOPERATIVE, INC. RESIDENTIAL AND COMMERCIAL AMP METER LOOP SPECIFICATIONS

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

SECTION GROUNDING AND BONDING

Plumbing Pipe Insulation Specification Submitted by: Armacell LLC. Plumbing Pipe Insulation Specification Armacell LLC 1

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Installation Instructions MINERAL INSULATED (M.I.)

Transcription:

Roof & Gutter Ice/Snow Melting Design Guide Page 1 of 10

Roof & Gutter Ice/Snow Melting Design Guide CONTENTS Application Overview Page 2 STEP 1 Layout Page 4 STEP 2 Calculating Amount of Cable Page 5 STEP 3 Electrical Requirements Page 6 STEP 4 Installation Page 7 STEP 5 Components Page 9 STEP 6 Controls Page 10 Page 2 of 10

APPLICATION OVERVIEW Drexan HeatTracer MultiTrace Products are ideal for maintaining gutters, downspouts and roofs free of snow and ice buildup on industrial, commercial and domestic structures. MultiTrace is capable of providing de-icing in ordinary locations as well as where excessive moisture is of concern. MultiTrace is designed to self-regulate its heat output by tailoring its current flow to ambient conditions in the most extreme climatic temperatures. MultiTrace can be cut to length in the field, which allows for quick and easy installations as well as simple additions or modifications to an existing installation. HEATING CABLE CONSTRUCTION Bus wires Polyolefin inner jacket Polyurethane inner jacket surrounding heating element APPLICATION Tinned copper braid Polyolefin outer jacket AREA CLASSIFICATION TRACED SURFACE TYPE SUPPLY VOLTAGE MT-5-1 MT-5-2 TEMPERATURE RATING MAXIMUM MAINTAIN OR CONTINUOUS EXPOSURE TEMPERATURE (POWER ON) MAXIMUM INTERMITTENT EXPOSURE TEMPERATURE, 1000 HRS (POWER-ON) TEMPERATURE ID NUMBER (T-RATING) MINIMUM INSTALLATION TEMPERATURE APPROVALS 0518 II 2G Ex e IIC T6 Gb Sira 12ATEX3095X Ordinary locations Metal, Plastic, Asphalt, and Wood 100-130 VAC 208-277 VAC 150 F/65 C 185 F/85 C T6: 185 F/85 C. Temperature ID numbers are consistent with all North American electrical codes -40 F/-40 C Class I, Div. 1/2, Groups A, B, C, D Class II, Div. 1/2, Groups E, F, G Class III 231572 G-General Use Ordinary Locations FOR HEATTRACER TECHNICAL ASSISTANCE CALL 1-800-663-6873 (NORTH AMERICA ONLY) OR +1.780.413.1774 Page 3 of 10

STEP 1 LAYOUT The area required to be heat traced will be determined by the size and shape of the structure. For example an entrance with an overhang may be susceptible to drifting snow accumulation and require the total area to be heat-traced. Typically the problem areas of a roof are: Roof overhangs without gutters Roof overhangs with gutters & downspouts Gutters & downspouts only Roof valleys & gutters Drains and scuppers on flat roofs Page 4 of 10

STEP 2 CALCULATING AMOUNT OF CABLE In instances where extremely cold temperatures and or severe winds are present it is recommended that the gutter and downspouts include 2 runs of MultiTrace. Installing 2 runs of MultiTrace (down and back) in the downspout eliminates the need for a T- Splice and one end seal. Roof: To establish the amount of cable required to trace the roof refer to Fig.1-1 The amount of snowfall will determine the pitch (spacing) of the cable. For heavy snowfall 12, medium 18 and light 24. Below is the multiplying factor in feet to determine the length of cable required to heat trace a roof up from the edge. Multiply the factor below by the length of edge in feet. Example: Roof edge = 100', spacing pitch = 18", up the roof 12". 100 x 2.5 = 250 feet cable. Note: does not include length required for the roof edge or gutter. Roof Spacing Pitch (inches) 6 12 18 24 Tracing Height 6 1.1 1.4 1.8 2.2 Inches up from 12 2.1 2.2 2.5 2.8 roof edge 18 3.1 3.2 3.4 3.6 Fig. 1-1 24 4.1 4.1 4.3 4.5 30 5.1 5.1 5.2 5.4 36 6.1 6.1 6.2 6.3 42 7.1 7.1 7.2 7.3 48 8.1 8.1 8.2 8.3 Gutter: To calculate the length of MultiTrace required to trace a gutter (2 runs) 100 ft. long and two 15 ft.-long downspouts. 100 + (2x15) = 130 x 2 runs = 260 ft. Note: allow 4 extra cable for terminations and allow sufficient cable to reach your power connection point. Page 5 of 10

STEP 3 ELECTRICAL REQUIREMENTS Try to design the MultiTrace heat-tracing system using a worst-case start-up temperature of 0 F / - 18 C. If longer circuits are required you may want to choose a higher start up temperature to increase the maximum circuit length allowed for the appropriate breaker size. However, keep in mind that if the heating system starts up at a temperature lower than that designed for, you may experience breaker tripping. Tip: selecting a higher voltage allows you to reduce the breaker-size required and in turn allows you to use longer circuit lengths. MAXIMUM CIRCUIT LENGTH IN FEET (METERS) START-UP AMBIENT TEMPERATURE CIRCUIT BREAKER SIZE F C 15A 20A 30A 40A MT-5 @ 120V 32 0 100 (30) 135 (41) 200 (61) - 20-7 95 (29) 125 (38) 185 (56) 200 (61) 0-18 80 (24) 100 (30) 155 (47) 200 (61) MT-5-2 @ 208V 32 0 190 (58) 250 (76) 380 (116) - 20-7 180 (55) 235 (72) 355 (108) 380 (116) 0-18 145 (44) 195 (59) 290 (88) 380 (116) MT-5-2 @ 240V 32 0 200 (61) 265 (81) 400 (122) - 20-7 190 (58) 250 (76) 370 (113) 400 (122) 0-18 155 (47) 205 (62) 305 (93) 400 (122) MT-5-2 @ 277V 32 0 215 (66) 290 (88) 415 (126) - 20-7 200 (61) 265 (81) 400 (122) 415 (126) 0-18 165 (50) 225 (69) 330 (101) 415 (126) WATTAGE OUTPUT: 12 Watts/ft. (39 Watt/m) in ice/snow GROUND-FAULT PROTECTION: Global Electrical Codes require ground-fault protection of components and each heating cable branch circuit to reduce the danger of fire caused by continuous electrical arcing resulting from improper installation or damage to the heating cable. Conventional circuit protection may not be suitable for preventing electrical arcing. Following are some of the ground-fault breakers that satisfy this equipment protection requirement: Square D Type QOB-EPD or QO-EPD and Cutler Hammer (Westinghouse) Type QBGFEP. COMPONENTS: Drexan offers a full range of components for power connections, splices, and end seals. These components must be used in order to ensure proper functioning of the product and compliance with warranty, code and certification requirements. FOR HEATTRACER TECHNICAL ASSISTANCE CALL 1-800-663-6873 (NORTH AMERICA ONLY) OR +1.780.413.1774 Page 6 of 10

STEP 4 INSTALLATION The effectiveness of heat tracing a roof or gutter is determined not only by the design and layout but also by the quality of installation workmanship. It is important that the MultiTrace be in contact with the roof and gutter to ensure proper melting. Do not install MultiTrace under the roofing materials. To prevent damage to the cable where snow might slide from the roof, it may be necessary to install a snow fence near the edge of the roof. Downspouts to underground sewers should be traced down below the frost line. Roof drains should be heat-traced 12 down into the heated portion of the building. Heat-tracing the roof itself is not always necessary. If ice-damming on the roof is not experienced then heat-tracing the gutters and downspouts should be sufficient. If gutters are not present then MultiTrace installed on the roof must have drip loops extending past the roof edge. Roof clips may be secured to surfaces by way of adhesive (not supplied by Drexan) to avoid the use of nails or screws. Junction boxes whenever possible should be located under a roof overhang or a similar area to avoid direct exposure to weather and should include drip loops where the cable enters the box. On a larger installation using multiple circuits try to locate all the junction boxes in one area to reduce power feed conduits. A complete Bill of Materials should include MultiTrace cable, power termination, end seal, roof clips, downspout hangers and control as required. Page 7 of 10

Typical installations below show the proper methods of installing MultiTrace. Asphalt Roof Metal Roof Heat-tracing a valley, roof edge and gutter. Heat-tracing a roof edge and gutter. Installation without gutters Roof clips may be fastened by way of adhesive (not supplied by Drexan) Page 8 of 10

STEP 5 CABLE COMPONENTS A typical heat tracing system will include cable, cable components and controls as required. HeatShrink Components HS-PC Power Connection (Junction box not included) HS-TSPLICE Splice Kit HS-ESK End Seal Kit HS-JB Junction Box PowerPod Components PP-PC-HL (Hazardous) & PP-PC-OL (Ordinary) PowerPod Power Connection and Splice Kit allow a power supply to one heating cable (power to heater) or a splice between two heating cables (heater to heater). PP-RE-L PowerPod Re-enterable End Seal is an above thermal insulation end seal designed for repeated use and entry should cable modification be required in the field. Cable Fastening Accessories Roof Clip, RC50 Downspout Cable Support, MT-CS Aluminum Foil Tape, TAPE-AL Page 9 of 10

STEP 6 CONTROLS Snow/Ice Melting Controls For most heating cable systems a contractor will be required because the load will exceed the amperage rating of the control unit. To determine the optimum control method, you should consider that when the cables are energized (ambient method) and there is no snow/ice present, power will be consumed unnecessarily. On the other hand if you rely on manual control and someone neglects to turn on the system when necessary, the inevitable snow/ice will form thereby defeating the original purpose of the installation. There are three recommended methods of heat tracing control for roof and gutter. Manual Control: MultiTrace is switched manually. This method requires supervision to work effectively. Ambient Control: using an ambient thermostat ensures that when the temperature is below freezing the MultiTrace becomes energized. With this method you must recognize that even when no snow/ice is present the cables may become energized and power consumed. Automatic Control: this method ensures that MultiTrace is energized only when a combination of moisture and low temperature are present, thereby keeping the roof and gutters free of snow/ice. When either the precipitation ceases or the temperature rises above freezing the MultiTrace is turned off thus conserving energy. Gutter Sensing Page 10 of 10