Multi-layer Insulation Blanket for Walls

Similar documents
Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for

Multi-layer Insulation Blanket for use in Walls

Multi-layer Insulation Blanket for Floors

Multi-layer Insulation Blanket for Floors

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.



Multifoil-Insulation.com. The Highest Performing Certificated MultiFoil on the Market Thermally the best performing multi-foil on the market by far.

2 in 1 Breathable Multi-layer Insulation Blanket. Thermal insulation in a 40mm thin, flexible, multi-layer breathable membrane

BDA Agrément BAW /01/C

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

Concrete Soffit Direct Fix

An introduction to Part L U-values

The brighter way to insulate

Floors Walls Roofs. Jabfill Premium. APPLICATION: Full-fill Cavity Wall Insulation PRODUCTS: Vencel Resil Limited

Installation instructions Thin, flexible multi-foil insulation

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

CERTIFICATE No VTT-C Date of issue

Superior Performance PIR Insulation. XO/FB Insulaton for Steel & Timber Frame. Walls 12/4956

PRODUCT GUIDE. One of the most comprehensive selections of Insulation Products on the market

Product & Installation Guide for New Build & Refurbishment Projects. exceeding the performance criteria of all current Building Regulations

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

June Residential New Build Timber Frame Walls

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

LABC REGISTERED THERMAL SYSTEMS TO PART L

Certificate No: EW560

The Celotex Handy Guide

LABC RegisteRed thermal systems to PARt L 2006 And 2010 multi-foil insulation And BReAtheR membranes

TRISO-SUPER 10 DATA SHEET

Typical detail: New roof with breathable underlay

Thermal Laminate Board.

A4/8 PS AW2002 Issue 6 Sept Permishield

A4/8 PS AW2324D Issue 10 May Permishield

K12 Framing Board. Insulation

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

The Ufoil Range of Insulation

Jabfill High Performance (HP)

Wall lining Inner leaf blockwork. K106 Cavity Board. Flexible sealant STANDARD DETAILS FOR 115 MM INSULATION BOARD IN A 125 MM CAVITY

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

A4/6 PS AW1551 Issue 4 Nov Permishield

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

PIR Insulation XT/TF. Insulation for Timber Framed Walls. Walls 08/ /0183

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES

URSA MINERAL WOOL URSA Cavity Batts

Light steel frame walls

TECHNICAL. Cavity Wall Partial - Fill Insulation. Stylite.

PIR Insulation XT/TL-MF. Insulation for Drylining Walls (Mechanically Fixed) Walls 04/ /0183

Building Regulations for the Conservation of Fuel and Power

A Handbook of thermal bridging details incorporating aircrete blocks

Loft Conversions - Attic Walls

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. Date of update May 30, 2018 Valid until May 29, 2023 HYBRIS

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for

PRODUCT & INSTALLATION GUIDE

BBA Information Bulletin No 3

CALL TO TALK TO THE SAS TEAM

Limiting (average) Limiting (individual) Extensions (Wall>0.70, Roof>0.25) Extensions (Wall<0.70, Roof<0.25)

URSA TF Roll URSA GLASSWOOL.

Brick Veneer Walls. Insulation

A Handbook of thermal bridging details incorporating aircrete blocks

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

June Non - Residential Refurbishment Internal lining walls

Garage Conversion - Between and Under Joist Applications

URSA Cavity Batts URSA GLASSWOOL.

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Best Prac ce Guide No. 2. (Version 1 April 2015) Design and Installa on guidelines for par al fill cavity wall boards

The Celotex Handy Guide

Superior Performance Phenolic Insulation SR/TB. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls AS LOW AS

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6

Hello Future DUAL TESTING. DUAL PERFORMANCE. HYBRID.

GypLyner IWL Independent wall lining system

PIR Insulation. XT/PR Insulation for Pitched Roofs. Roofs 08/ /0183

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

Why party wall insulation is required

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

June Residential New Build Render and cladding walls

CONCRETE BLOCKS Lignacite

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

June Non - Residential Refurbishment 5.5 Basements

Double Brick Cavity Walls

Boost' R Hybrid Roof GENERAL INSTALLATION GUIDELINES GENERAL INFORMATION TOOLS / ACCESSORIES PRECAUTIONS -1- VIEW ACTIS HYBRID VIDEOS ON

PIR Insulation XT/TL. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls 04/ /0183

Hello Future HYBRID SOLUTIONS AND SYSTEMS. NHBC acceptance

URSA MINERAL WOOL URSA Timber Frame Roll & URSA Timber Frame Slab

EZWall TM REAL BRICK CLADDING SYSTEM. E uroform Products Ltd. Solutions for the building industry

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

GypLyner UNIVERSAL Metal framed wall lining system

HP Partial Fill. Robust, long-lasting protection

Transcription:

Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification Thermally tested in accordance with EN 16012 High thermal resistance of up to 3.00m²K/W Class 1 Surface spread of flame Ideal for New build & Refurbishment Effective solar overheating barrier Lightweight, flexible & 40mm thin Fast and simple installation Vapour control layer External application www.ecohomeinsulation.com Thermally the best performing multifoil on the market by far. RD850111 194186

Insulation for use in Walls Benefits General Meets requirements of L1A, L1B 2010 Fully certificated Thermally tested in accordance with EN 16012 High thermal resistance of up to 3.00m²K/W Class 1 Surface spread of flame Ideal for New build & Refurbishment Effective solar overheating barrier Lightweight, thin & flexible Fast and simple installation Vapour control layer is a very flexible, easy to fit, multilayer insulation thermally tested in accordance with EN 16012 achieving a high thermal resistance of up to 3.00m²K/W for accompanied by a 25mm air cavity either side of the material. How does Work? Due to the special composition of multilayers of insulation, effectively deals with all forms of energy transfer (i.e. conduction, convection and radiation). works most effectively by reflecting infrared radiation. This means that not only is effective in winter by reflecting heat back into the building and cold out, but also in summer is a very effective solar over heating barrier reducing the need for artificial cooling systems, preventing uncomfortable heat build up in the building. Installation of for Timber Frame and Masonry Wall Applications and additional insulation products should be in accordance with the Certificate, YBS fixing instructions and current good building practice. When the is cut to fit around openings, care should be taken to minimise gaps. can be cut easily using sharp scissors or a knife. The surfaces of the masonry wall should be sound and free from loose material; large projections should be removed and holes filled and levelled. A survey of the wall may be required to establish the extent of any packing that may be required to ensure a uniform plane for the materials to be fixed. Bearing surfaces for timber battens should comply with BS 8212 : 1995. The depth of timber battens will determine the air space achieved on either side of the, YBS recommend 25mm battens. All joints and perforations in the products must be securely sealed with YBS Foil Tape Services may be accommodated within the void created by the dry lining system. RD850111 194186 1

Timber Frame & Dormer Cheeks Installation of for Timber Frame wall applications and additional insulation products should be in accordance with the certificate, YBS fixing instructions and current good building practice. is applied directly from the roll either vertically or horizontally depending on the wall height, pulled tight and stapled onto the timber studs at minimum 300mm centres. UValue Combined Method (W/m 2 K) 0.24 BreatherFoil FR Sheathing Board Stud 102.50 50.00 4.00 12.00 89.00 0.770 0.060 0.133 0.665 0.125 0.092 should be overlapped at each joint by approx. 50mm and stapled onto the battens, the joins should be sealed using 75mm YBS Foil Tape. 14.00 12.50 0.190 0.066 Perpendicular counter battens, recommended 25mm by 38mm are fixed to the wall. Battens must always be placed at the top and bottom of the wall and around the perimeter of doors and windows. The plasterboard is fixed over the materials and onto the battens in the usual manner. BreatherFoil FR 0.120 Sheathing Board Stud UValue table Description 25mm Batten 38mm Batten and YBS BreatherFoil FR 0.25 W/m 2 k 0.24 W/m 2 k, YBS BreatherFoil FR and 50mm Glasswool 0.040 0.21 W/m 2 k 0.20 W/m 2 k, YBS BreatherFoil FR and 100mm Glasswool 0.040 0.17 W/m 2 k 0.16 W/m 2 k, YBS BreatherFoil FR and 25mm PIR 0.022 0.21 W/m 2 k 0.20 W/m 2 k, YBS BreatherFoil FR and 50mm PIR 0.022 0.18 W/m 2 k 0.17 W/m 2 k, YBS BreatherFoil FR and 100mm PIR 0.022 0.14 W/m 2 k 0.14 W/m 2 k, YBS BreatherFoil FR and 140mm PIR 0.022 0.13 W/m 2 k 0.12 W/m 2 k, YBS BreatherFoil and 0.17 W/m 2 k 0.17 W/m 2 k, Standard Breather Membrane 0.30 W/m 2 k 0.28 W/m 2 k, Standard Breather Membrane and 50mm Glasswool 0.040 0.24 W/m 2 k 0.22 W/m 2 k, Standard Breather Membrane and 100mm Glasswool 0.040 0.19 W/m 2 k 0.18 W/m 2 k, Standard Breather Membrane and 25mm PIR 0.022 0.25 W/m 2 k 0.23 W/m 2 k, Standard Breather Membrane and 50mm PIR 0.022 0.21 W/m 2 k 0.20 W/m 2 k, Standard Breather Membrane and 100mm PIR 0.022 0.16 W/m 2 k 0.15 W/m 2 k, Standard Breather Membrane and 140mm PIR 0.022 0.14 W/m 2 k 0.13 W/m 2 k, Standard Breather Membrane and 0.19 W/m 2 k 0.18 W/m 2 k 2

Wall A spider clip is fitted on to the wall tie against the inner leaf and this creates the minimum cavity between the product and the blockwork. The initial run of is positioned over the wall ties, ensuring that it is kept taut but with sufficient drop to below floor insulation. can be cut with a sharp blade to fit onto wall ties. The top edge of the material should be a minimum of 75mm over the top row of the wall ties giving a weathered lap joint. When a full run is in position, the retaining clip is fixed to the wall tie to keep the central to the cavity. The second leaf is built up to the topmost line of the wall ties, (or two courses below) and the second run of installed ensuring a minimum lap of 75mm. Vertical joints in the should always be on a line of wall ties, ensuring a 100mm lap (ie 50mm either side of the wall tie) and sealed using YBS Foil Tape At internal and external corners a recommended air space of 25mm must be maintained. UValue Combined Method (W/m 2 K) 0.24 Thermal Block Plaster Dabs Thermal Block s Plaster Dabs 102.50 50.00 40.00 20.00 100.00 15.00 12.50 0.770 0.110 0.190 0.040 0.133 0.909 0.170 0.066 UValue table Description 100mm 110mm and 100mm Dense Block 1.130 0.31 W/m 2 k 0.29 W/m 2 k and 100mm Medium Block 0.500 0.30 W/m 2 k 0.28 W/m 2 k and 100mm Lightweight Block 0.250 0.29 W/m 2 k 0.27 W/m 2 k and 100mm Thermal Block 1.110 0.26 W/m 2 k 0.24 W/m 2 k and 100mm Thermal Block 0.110 Thin Mortar 0.25 W/m 2 k 0.24 W/m 2 k and 140mm Dense Block 1.130 0.31 W/m 2 k 0.29 W/m 2 k and 140mm Medium Block 0.500 0.29 W/m 2 k 0.27 W/m 2 k and 140mm Lightweight Block 0.250 0.25 W/m 2 k 0.26 W/m 2 k and 140mm Thermal Block 1.110 0.24 W/m 2 k 0.23 W/m 2 k and 140mm Thermal Block 0.110 Thin Mortar 0.23 W/m 2 k 0.22 W/m 2 k 3

Dry Lining Vertical counter battens, minimum 25mm by 38mm battens are fixed to the wall at 400mm centres. Battens must always be placed at the top and bottom of the wall and around the perimeter of doors and windows. is applied directly from the roll either vertically or horizontally depending on the wall height, pulled tight and stapled onto the battens at minimum 300mm centres. UValue Combined Method (W/m 2 K) 0.28 Block 100.00 50.00 100.00 14.00 0.770 1.130 0.040 0.292 0.180 0.89 should be overlapped at each joint by approx. 50mm and stapled onto the battens, the joins should be sealed using 75mm YBS Foil Tape. Insulated 30.00 0.560 Counter battens are fixed to the wall battens through the material at 600mm centres. The plasterboard is fixed over the and onto the battens in the usual manner. Insulated s UValue table Description 25mm Batten 38mm Batten and Solid Wall 0.34 W/m 2 k 0.29 W/m 2 k, Solid Wall and 30mm Insulated EPS 0.29 W/m 2 k 0.26 W/m 2 k, Solid Wall and 40mm Insulated EPS 0.27 W/m 2 k 0.24 W/m 2 k, Solid Wall and 0.22 W/m 2 k 0.19 W/m 2 k and Wall uninsulated 0.33 W/m 2 k 0.28 W/m 2 k, Wall uninsulated & 30mm Ins. EPS 0.28 W/m 2 k 0.25 W/m 2 k, Wall uninsulated & 40mm Ins. EPS 0.26 W/m 2 k 0.23 W/m 2 k, Wall uninsulated & 0.22 W/m 2 k 0.18 W/m 2 k and Wall Insulated 0.25 W/m 2 k 0.22 W/m 2 k, Wall Insulated & 30mm Ins. EPS 0.23 W/m 2 k 0.21 W/m 2 k, Wall Insulated & 40mm Ins. EPS 0.22 W/m 2 k 0.20 W/m 2 k, Wall Insulated & 0.18 W/m 2 k 0.16 W/m 2 k 4

Dwarf Wall Installation of for dwarf wall applications with additional insulation products should be in accordance with the certificate, YBS fixing instructions and current good building practice. is applied directly from the roll either vertically or horizontally depending on the wall height, pulled tight and stapled onto the timber studs at minimum 300mm centres. UValue Combined Method (W/m 2 K) 0.19 Loft Void PIR (Between Studs) Stud cavity 50.00 35.00 14.00 0.22 0.040 0.500 2.174 should be overlapped at each joint by approx. 50mm and stapled onto the battens, the joins should be sealed using 75mm YBS Foil Tape. 12.50 0.190 0.066 Perpendicular counter battens, recommended 25mm by 38mm are fixed to the wall. Battens must always be placed at the top and bottom of the wall and around the perimeter of doors and windows. The plasterboard is fixed over the products and onto the battens in the usual manner. Loft Void PIR Stud s UValue table Description 25mm Batten 38mm Batten and 50mm Glasswool 0.040 0.24 W/m 2 k 0.22 W/m 2 k and 100mm Glasswool 0.040 0.19 W/m 2 k 0.18 W/m 2 k and 25mm PIR 0.022 0.25 W/m 2 k 0.23 W/m 2 k and 50mm PIR 0.022 0.21 W/m 2 k 0.19 W/m 2 k and 75mm PIR 0.022 0.18 W/m 2 k 0.17 W/m 2 k and 100mm PIR 0.022 0.16 W/m 2 k 0.15 W/m 2 k Two Layer 0.21 W/m 2 k 0.19 W/m 2 k 5

External Wall Insulation UValue Combined Method (W/m 2 K) 0.30 All timber exposed to the outer cavity, except naturally durable species should be treated. Render 19.00 0.390 is applied directly from the roll either vertically or horizontally depending on the wall height, pulled tight and stapled onto the timber battens at minimum 300 mm centres. Render Board Batten (Ventilated ) 22.00 14.00 should be overlapped at each joint by approximately 50 mm and stapled onto the battens, the joins should be sealed using 75mm YBS Foil Tape. Vertical battens, recommended 25 mm by 38 mm are fixed to the vertical battens; battens should always be placed at the top and bottom of the wall and around the perimeter of doors and windows. Brickwork Drylining plaster dabs 225.00 15.00 12.50 0.560 0.190 0.402 0.170 0.066 The carrier board is fixed over the product and onto the battens, the external rendered finishing should comply with BS EN 13914119. Decorative Render Render Board (Ventilated ) Brickwork businessgreen leaders awards 2012 winner Multilayer Insulation Blanket for Floors WWF Green GameChangers Innovation of the Year Knowsley Housing Trust B Y A architects UValue table Solid Wall 25mm Batten 38mm Batten and Cladding 0.30 W/m 2 k 0.26 W/m 2 k and Render Board (Ventilated ) 0.33 W/m 2 k 0.30 W/m 2 k Wall 25mm Batten 38mm Batten and Cladding 0.30 W/m 2 k 0.27 W/m 2 k and Render Board (Ventilated ) 0.33 W/m 2 k 0.31 W/m 2 k 6

RD850111 194186 CAD Drawings Can now be downloaded from www.ybsinsulation.com Foil taped joins should be overlapped at each joint by approx. 50mm and stapled onto the battens, the joints should be sealed using YBS 75mm Foil Tape. Vapour control layer When all joints are sealed using foil tape also works as a vapour control layer. knife available YBS Foil joining tape available Technical Properties Product Description 19 Components 40mm approx. Weight 800g/m 2 Mechanical Properties Value Reference Standard Core Thermal m 2 K/W BS EN 16012 Thermal 13mm 0.490m 2 K/W BS EN 16012 Thermal 20mm 0.790m 2 K/W BS EN 16012 Flammability Class E BS EN 135011 Water vapour resistance 1569MNs/g BS EN 12572 Emission coefficients of surfaces 0.02 EN 16012 Tensile strength 142KPA BS EN 1608 Packaging 15m 2 7.5m 2 Width 1.5m 1.5m Length 10m 5m Weight 12.5Kg 6.25Kg EcoHomeInsulation.com UK & European online supplier www.ecohomeinsulation.com UK Ordering: 0844 991 9949 European Ordering: 0044 1143230474 Yorkshire Building Services (Whitwell) Ltd. YBS V3 03/2013