Flare Measurement Advanced Ultrasonics

Similar documents
Mexico Gas Flaring Reduction. EU Flaring Regulatory Measurement Requirements & Best Practice Lynn Hunter

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA

USKON AKIŞKAN KONTROL SİSTEMLERİ SANAYİ VE TİCARET LTD. ŞTİ.

Saudi Aramco Uses Kurz to Help Monitor Flare Emissions

Manual of Petroleum Measurement Standards Chapter 5 Metering

Accutube Averaging Pitot Tubes

True Performance in Flow Measurement. Verabar. Velocity Averaging Flow Sensors

Saudi Aramco Uses Kurz to Help Monitor Flare Emissions

PRODUCT CONFORMITY CERTIFICATE

Author: Donald Pretty, Project Manager, Presenter: John Downs, Environmental Manager, B&W PGG, KVB-Enertec Products January 29, 2015

Scintillation Technology Bests NIST

API Review. Copyright 2007, FMC Technologies Measurement Solutions, Inc. PR0A028I Issue/Rev. 0.0 (7/07) - Slide 1

Fluid Flow Conditioning. August 2015

Volume Flow and Gas Flow Measuring Devices

What ensures measurement to accurate standards?

CALDON LEFM 380Ci Gas Ultrasonic Flowmeter

Problems with Pitots. Issues with flow measurement in stacks.

s the costs of fuels and consumables to rise, the ability to accurately measure the amount used in a process becomes significant

Custody Transfer: Technical principles for measuring system in the O&G market

The Paradigm Case Method of Flowmeter Selection

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

HIGH PERFORMANCE FLOW CONDITIONERS Michael P. Saunders Savant Measurement Corporation USA

Contour K5 Technical Information

MULTIPATH ULTRASONIC FLOW METERS FOR GAS MEASUREMENT Class #

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

ASME PTC Flow Measurement

A SAGE METERING White Paper SAGE METERING 8 Harris Court, Building D1, Monterey, CA Telephone: (831)

EuroFID Total Hydrocarbon Analyzer

SPE MS. Copyright 2015, Society of Petroleum Engineers

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Proven Flow Measurement Solutions for the Oil and Gas Industry

Flare Gas Metering: Minimizing Surprises

DIAL Measurements of Fugitive Emissions from Natural Gas Plants and the Comparison with Emission Factor Estimates

Appendix 1-A Well Testing

HX Performance Testing

On-Line Diagnostics Techniques in the Oil, Gas, and Chemical Industry

In-Line Inspection using Ultrasonic Technology

Ultrasonic Flow Measurement in Gas Storage Operations

Practical experience of using ultrasound flowmeters at the measurement associated petroleum gas

Determination of the Ethylene Oxide Control Efficiency from Catalytic Oxidizers. A Guidance Document

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

Like piezoresistive, piezoelectric,

Title: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation Monitor

Non-Invasive Gas Flow Measurement

40 CFR 98 Subpart W Petroleum and Natural Gas Systems

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Airflow Measurement for HVAC Systems Comparing Technologies June 11, 2003

High Temperature Ultrasonic Scanning

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

GTI METERING RESEARCH FACILITY UPDATE Edgar B. Bowles, Jr. and Marybeth G. Nored GTI Metering Research Facility Program, Southwest Research Institute

Gilflo flowmeters. for steam, liquids and gases

DRAFT Procedures for Quantifying Fugitive VOC Emission Sources at Petroleum Facilities

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

FLUXUS G. Non-Invasive Gas Flow Measurement. External Measurement of Internal Flow. Natural Gas Extraction. Offshore. Gas Transmission.

Clamp on Ultrasonic Flow Measurement Principal Transit Time Doppler What Distinguishes Flexim Technology

Remote Sensing Studies Demonstrate that Refinery Emissions are Underestimated.

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

EPA s Proposed GHG Reporting Rule:

WYATT Orifice flow PrOducTs

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Mitigating Emissions and Maintenance Constraints with Flare Consolidation

INTERNATIONAL STANDARD

Improved Flow Monitoring for Process Efficiency Improvements through New Technology Utilizing Non-Invasive Passive Arrays

REAL-TIME CONCENTRATION AND GRAIN SIZE MEASUREMENT OF SUSPENDED SEDIMENT USING MULTI-FREQUENCY BACKSCATTERING TECHNIQUES ABSTRACT

Selecting the correct device for measurement control

measurement sensor and data transmission technology innovation has reduced installation costs, simplified maintenance and enhanced plant performance

San Joaquin Valley Air Pollution Control District. Procedures for Quantifying Fugitive VOC Emissions At Petroleum and SOCMI Facilities

Applying Dynamic Process Simulations Toward Flaring Reduction

Final DRAFT API TECHNICAL REPORT. Carbon Content, Sampling, & Calculation

CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS

COMBIMASS Thermal Gas Flow

Method Implementation Document for BS EN * - Application to manual stack emissions monitoring

Unique Flow Measurement Challenges for Large UV Systems

What information should be submitted to the District regarding Circulation Tanks for Well Stimulation Treatments?

EXPERIMENTS WITH THE THERMODYNAMIC METHOD

HILASE - QUALITY CONTROL INSTRUMENT

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

CUSTODY TRANSFER SYSTEMS FOR NATURAL GAS AND CHALLENGES IN ITS MEASUREMENT AND HANDLING

Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX

Contents. 1 Gas Measurement Fundamentals Head Meters Turbine Meters Other Meters Orifice Meters... 5.

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

What Criteria to Consider in Selecting a Water Cut Monitor known as Basic Sediment and Water Meter (BS&W)

NEW ON-SITE CALIBRATION TECHNIQUE FOR LARGE FLOW METERS USING LASER DOPPLER VELOCIMETRY

Automation and Maintenance Management Systems SMART INSTRUMENTATION FOR THE WATER INDUSTRY

FLUXUS F/G601 and F/G608

INSTALLATION EFFECTS AND DIAGNOSTIC INTERPRETATION USING THE CALDON ULTRASONIC METER

ADVANCED INSIGHT FOR CUSTODY TRANSFER MEASUREMENT

1. Introduction. 2. The motivation of the development 10.8 RIVER FLOW INFORMATION SYSTEM WITH RF CURRENT SENSORS

Improve pipeline safety and optimize its capacity

LNG workshop. Flow Metering. Peter Lucas and Nikola Pelevic

A M E M B E R O F T H E K E N D A L L G R O U P

VLM10 In-line Vortex Mass Flow Meter

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators

HORIBA Portable Emissions Measurement Systems (PEMS)

Erosion Effects in Flowmeters

Flow measurement: some problems to solve and some surprises. Dr Michael Reader-Harris, NEL

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside.

DETECTION AND QUANTIFICATION OF DETRIMENTAL CONDITIONS IN HDPE USING ULTRASONIC PHASED ARRAY

3 Steps to Better Steam Temperature Control Proven Strategies to Minimize Thermal Stress and Tube Leaks

Transcription:

Flare Measurement Advanced Ultrasonics John Chitty Regional Sales Manager SICK MAIHAK, Inc. 15415 International Plaza Drive, Suite 100 Houston, Texas 77032 1.0 Introduction There has been an increased awareness by oil and gas companies in North America toward emissions monitoring and reduction for both environmental and economical reasons. For years, several countries worldwide have had stringent regulations in place. Regulations were implemented in 1993 relating to the measurement of fuel and flare gas for calculation of CO 2 tax in the petroleum activities on the Norwegian continental shelf. Inevitably, oil companies operating in the region had to comply with these regulations. With new government legislation, producers, refineries and chemical companies have been looking for a cost effective solution to reduce emissions and to provide tighter control for both leak detection and mass balance. To tolerate the extreme process conditions often found in a flare line, yet provide accurate measurement to comply with international regulators such as the Energy Resources Conservation Board in Canada, the European Union, or the Texas Commission of Environment Quality, the technology of choice is important. Several metering technologies have been tested with little success. To understand why the results have been dismal, one needs to fully understand the challenges associated with the application. Further investigation towards the effects of sonic noise generated from high gas velocities, elbows, Ts, and pipe segments, has been conducted and the results detailed in this paper. 2.0 Government Legislation In Canada, the Energy Resources Conservation Board (ERCB) (www.eub.ca) Directives 60 states in section 10, Metering Requirements and Guidelines, that meters designed for the expected flow conditions and range must be used to measure the following flare and vent streams; Continuous or routine flare and vent sources at all oil and gas production and processing facilities (including heavy oil and crude bitumen) where annual average total flared and vented volumes per facility exceed 500 m3/day, (exceeding pilot, purge, or dilution gas); If all solution gas is flared or vented from any production facilities, the measured produced gas (less fuel gas use) may be used to report volumes flared or vented. Acid gas flared, either continuously or in emergencies, from gas sweetening systems regardless of volume; and Fuel (dilution or purge) gas added to acid gas to meet minimum acid gas heating value requirements, or Alberta ambient air quality objectives. ERCB Directive 60 references Directive 17. Measurement Requirements for Upstream Oil and Gas Operations and specifies the following uncertainties must be met. Measurement uncertainty for flare gas ± 5 %. Measurement uncertainty for dilution gas ± 3 % Measurement uncertainty for acid gas ± 10 %.Accuracy specifications apply to the overall range- ability of the process conditionsthe European Union has followed suit (www.europa.eu). In reference to the guidelines for the monitoring and reporting of greenhouse gas emissions pursuant to Directive 2003/87/EC of the European Parliament and of the council dated 2006, emissions from flares shall include routine flaring and operation flaring (trips, start-up and shutdown as well as emergency reliefs). This is determined by taking the products of the 1

activity data, emission factor, and oxidation factor and considers both the amount of gas flared and the carbon content of the flared gas. The activity data is divided into three tiers. The amount of flare gas used over the reporting period is derived with maximum uncertainties of +- 17.5%, +- 12.5 %, and +- 7.5% for Tier 1 through to Tier 3 respectively. The selected tier shall reflect for each emission source, the highest level of accuracy that is technically feasible, which will be subject to approval by a competent authority. For the reporting periods 2008-2012 as a minimum tier 2 in Annex XII shall be applied unless technically not feasible. In the United States, the Texas Commission of Environment Quality (TCEQ, www.tceq.state.tx.us) specifies an uncertainty of +- 5% for a flare gas flow meter at 30, 60, and 90% of range under the installed conditions. In California, rule 1118 essentially mirrors Texas with uncertainty requirements of +- 5% at flow rates of 0.3 m/s and higher, and +- 20% at velocities of 0.03 to 0.3 m/s. 3.0 Flare Metering Challenges Flaring systems are used to combust large quantities of waste gas during emergency shutdown (ESD) situations as well as smaller quantities of hydrocarbons that are uneconomical to process. Two of the most important considerations when installing flare meters are flow profile and gas composition. There are other challenges when trying to measure flare gas, including large pipe diameters, high flow velocities over wide measuring ranges, low pressure, dirt, wax, CO 2, H 2 S, and condensate. Flare headers operate at near atmospheric conditions with some upstream relief valves relieving at as low as 5 psi. To ensure adequate flow from all process relief systems, a maximum pressure drop specification is often set to 0.5 psi. There can be great changes in the gas composition going to flare, in terms of molecular weight, which can significantly impact the uncertainty of many flow-metering technologies. Velocities ranging from 0.05 m/s to over 100 m/s in emergency shut down situations have been recorded. To put that in perspective, 100 m/s is equivalent to 360 km/hr. Category 5 hurricanes reach wind speeds of 249 km/hr and have the ability to create mass destruction. Design worst-case events, or greater velocities are infrequent, and it may be required to use additional process data to estimate the flow of such emergencies, such as determining isolated and or de-inventoried units. 4.0 Metering Technologies An evaluation was conducted on some of the more common technologies believed to be suitable for flare measurement. These included Transit time ultrasonic, Insertion turbine, thermal mass, averaging pitot tubes and optical transit time velocimeters. Thermal and insertion turbines are point sensors that must be inserted in the center 3 rd of the pipe, that typically range from 4 to 72 diameters. When subject to high velocities, bending and complete failure has occurred. Both turbines and averaging pitot tubes are limited to approximately 10:1 turndowns. Stacked transmitters will provide higher turndown ratios but still fall short of meeting the requirements. Thermal meters have the ability to reach substantially higher turn down ratios; some up to 1000:1 when flow calibrated on air or natural gas. However, changing gas compositions which are common due to multiple plant processes leading to a common flare header adversely affect the measurement. Each gas has different thermal properties that effect convection heat transfer which is the measurement principle of thermal mass meters. Without self-diagnostics, preventative maintenance programs need to be implemented and the sensors extracted quarterly for inspection. Point sensors are limited in their ability to correct for asymmetry or flow profiles that are not fully developed and as a result, require considerable upstream piping to minimize installation effects. This is generally not an option when working with such large pipe diameters. Optical transit time velocimeters are relatively new when it comes to flare measurement. They rely on particles in a flowing gas stream to pass through two laser beams focused in a pipe by eluminating optics. Laser light is scattered when a particle crosses the first beam. The detecting optics collects scattered light on a photo detector which generates a pulse signal. If the same particle crosses the second beam, the detecting optics collect scattered light on a second photo detector, generating a second pulse. By measuring a time interval between these pulses, a gas velocity is calculated. The measured value is dependent on the purity of the gas moving 2

through the pipe. This may also be referred to as the number and consistency of particles in the gas stream. Such particles are referred to as dirt. Fewer detectable particles and or lower velocities result in greater uncertainty limiting low flow capabilities. Tests performed at low to high pressures, versus atmospheric will have an impact on gas density and the number of measurable particles per unit volume. The same tests demonstrated that 40D of straight pipe were required to minimize installation effects and to achieve an average uncertainty of approximately +- 2% without the use of a flow conditioner. The majority of field tests were conducted on smaller pipe diameters ranging from 2 to 16, and it s the authors believe these tests are ongoing. 5.0 Advanced Ultrasonics Ultrasonics have been used successfully in flare measurement applications for years but have been limited to approximately 85 m/s For that reason, the focus of this paper has been to further develop the technology as it pertains to flaring, and ultimately improve on the limitations. There are two primary principles; transit time measurement and Doppler Effect. If a sound wave is reflected from a moving object, a frequency shift occurs. This frequency shift is the Doppler Effect and can also be utilized in flow measurement. However, due to the nonreflective nature of the process conditions at hand, this method is not practical. The transit time gas flow meter is based on the measurement of contra propagating ultrasonic pulses, in which the transit time of the sonic signal is measured along one or more diagonal paths in both the upstream and downstream direction. Single path meters utilize two transducers; both receive and transmit ultrasonic pulses. The flow of gas causes the time for the pulse traveling in the downstream direction to be shorter than for the upstream direction, and this time difference is a measure for the rate of the gas flow as illustrated in Figure 1. Figure 1 Meters designed for flare measurement must operate under atmospheric pressure and require high efficiency transducers to effectively transmit and receive the ultrasonic pulses. In all cases, the processing of the information coming from the transducer set is performed in a dedicated control unit like that shown in Figure 2. Control Unit Ultrasonic Transducers Figure 2 The flow computer controls the transmission and detection of the signals to and from the transducers which perform the critical time measurements. There are multiple outputs configurable for different parameters and interface is selectable between RS232C, RS422, and RS485. Meter sizes range from 4 to 72 and have both low-end measurement requirements for day to day operations as well as high end for emergency shut down (ESD) situations. Plant leak detection and mass balance are often necessary while the overall range is required for emission monitoring to comply with national legislation. Typical uncertainties are ± 2... 5 % of measured value and resolutions ranging from +/- 0,003 m/s at +/- 0.03 m/s up to +/- 0.3 m/s. Reproducibility is generally +/- 1% at 0.15... 30 m/s. Most ultrasonic flow meters are capable of correcting for asymmetry and flow profiles that are not fully developed to some degree. This is accomplished two ways; use the Reynolds number as a measure of the flow profile and adjust the measured axial flow velocity according to a function based on the Reynolds 3

number estimated. The second method is to measure the entire cross sectional area of the pipe, which will average out the error. Combining the two methods reduces the number of upstream pipe diameter requirements. Volumetric flow Q OS, through the representative cross sectional area A and the mean gas velocity across the cross-section v A is defined in equation 1. The control unit determines the representative mean value of the flow velocity on a sound path v (path velocity) between the two transmitter/receiver units. Since the mean values of the path and surface velocity are not identical, a functional, systematic correlation between the calculated path velocity and mean surface velocity similar to the point based flow measurement can be corrected by using equation 2. With an unimpeded, axial symmetric flow profile, the value for K can be 0.9 to 1.0. When this is not the case, a second-degree calibration function can be implemented to map the correlation between the mean path and surface velocity as shown in equation 3. If the flow in a round pipeline is unimpeded and axial symmetric, Cv1 is equal to the correction factor k. Q OS = v A A Equation 1 V A = K v Equation 2 V A = Cv2 v2 + Cv1 v + Cv0 Equation 3 Base design conditions for flowing velocities in gas distribution and transmission pipelines are generally limited to 21m/s in accordance to API Report 14E due to internal erosion and vibration components. Velocities at this rate can be measured using frequencies ranging from 135 210 KHz. To overcome pulsation effects, and/or control valve noise, one should consider using at least 210 KHz or 340 KHz transducers, combined with higher sampling rates. These frequencies are substantially greater then the noise generated, and the high sampling rates will capture the data throughout the pulsation cycle. When measuring extreme velocities in a flare line, transducers with frequencies such as 42 KHz to 135 KHz should be considered. Just as low frequency base will travel further then high frequency treble from an amplifier, the same is true in ultrasonic flow meters. However, the challenge to measure velocities greater than 85 m/s still existed. Several have attempted to alter the transducer angle in combination with implementing a slight transducer offset as shown in Figure 3. In theory, this would create what is referred to as a ray rescue angle that would help reduce blow away effects from high velocity gases. Although somewhat effective, one needs to consider % CO2 and pipe diameter. CO2 attenuates an ultrasonic signal due to fewer molecules. Increased pipe diameters cause further dissipation of the same signal due to an increased time of flight. An offset has the ability to also adversely affect the signal strength and become more of a detriment then an improvement. Figure 3 Other designs utilize a continuous sine wave signal in combination with a variable frequency signal, also known as a Chirp signal. This signal is given a unique recognizable form characterized by the pulse duration and the varying signal frequency. At higher velocities the instrument uses only these Chirp signals. Advanced processing capabilities by itself are not enough, primarily at the high end of the velocity spectrum. Extensive research at an ambient pressure calibration facility in Germany shown in Figure 4 has revealed 3 primary sources that make it difficult to effectively measure the velocities in question. Those are; external noise sources caused from the plant or personnel, noise that occurs at the edge of the transducer face from the flowing gas, and signal drift caused from swirling gas that stimulates the vibrating membrane of the transducer face as shown in figure 5. These swirls can destroy the ultrasonic wave form which will change the direction of the signal and cause drift. It was determined that by embedding the ultrasonic transducer inside a flow optimized profile shape, the noise and signal drift would be minimized. 4

Figure 4 Figure 5 The profile shape referenced closely resembles the Joukowski airfoil as shown in figure 6. Many years ago, the Russian mathematician Joukowski developed a mapping function that converts a circular into a family of airfoil shapes. Conformal mapping is a mathematical technique used to convert (or map) one mathematical problem and solution into another. It involves the study of complex variables. The mapping function also converts the entire flow field around the cylinder into the flow field around the airfoil. We know the velocity and pressures in the plane containing the cylinder. The mapping function gives us the velocity and pressures around the airfoil. Knowing the pressure around the airfoil, we can then compute the lift. Process simulation shown in figures 7 through 9 proved that with this design, process gas represented by velocity vectors did not shear away from the surface of the probe. The red line on each figure demonstrates the point on the sensor face that the velocity is measured. There is a slight pressure drop created, as the process velocity increases over the raised section. At each point, there is no effect of flow breaking away from the transducer surface which was caused by the sharp edges of the previous design. Furthermore, the swirl caused by the same sharp edges that stimulated the transducer membrane was practically eliminated. Signal noise was reduced by nearly 50% and signal drift was reduced by 30%. Figure 10 shows the results of the wave forms for both standard transducers as well as the new high speed transducer at 94 m/s. SNR is 19 db, and the error percentage was 62% at atmospheric pressure. Error is defined as the number of pulses per sample effectively being received. With advanced microprocessors, a typical sample rate may be 75 times per second. With a 62% error rate, 38% of the samples were being received, well beyond an alarm threshold that would be set from the factory at 10% before the measurement is degraded. The physical characteristics combined with special optimized signal algorithms including cross correlation make it possible to now effectively measure velocities accurately at normal operating conditions, as well as those experienced in emergency shut down situations. 5

Figure 6 Figure 7 Figure 8 Figure 9 6.0 Conclusion While ultrasonic meters can effectively measure extremely low and high velocities, it is important the user understand what takes place in the pipe at such velocities and what they can realistically expect from their metering system. In one example, 3 meters, all on substantially smaller line sizes, measured an estimated total accumulated gas volume of 2.4 E3M3 per day, prior to the gas flowing into a 30 low pressure line. At atmospheric pressure and temperatures ranging from 0 to 35 degrees C, the calculated velocities through a 30 line fall below 0.1 m/s. The specified uncertainty of one manufacturer s ultrasonic meter at velocities less then 1.95 m/s without installation effects is +- 0.02 m/s. Velocities of 0.1 m/s equates to an uncertainty of +- 20% in laboratory conditions. It is not practical to install flow conditioners upstream in flare meter applications, nor would they be very effective at such low rates. Therefore, an unimpeded, axial-symmetrical flow profile cannot be guaranteed and will add to the overall uncertainty of the meter. It is also important to note certified calibration facilities including CEESI, TransCanada Calibrations and SWRi cannot guarantee reproducibility at velocities below approximately 0.3 m/s due to these same uncertainties. In such cases, it may be more practical to rely on accurate metering from each of the lines leading into the flare header for velocities below 0.5 m/s to comply with government regulations. At extreme velocities, beyond 100 m/s, process noise may drown out the ultrasonic signal making it unrecognizable. In either case, the user should consult with the manufacturer. Ultrasonic flow meters designed for flare gas measurement have been in use since 1987. They are unaffected by changing gas composition. There are no mechanical moving parts and self- diagnostics eliminate preventative maintenance programs. When required, the sensors may be extracted from the flare line without shutting down the process for cleaning or calibration checks. They have proven to be a cost effective solution to reduce emissions and to provide tighter control for both leak detection and mass balance. They provide turn down ratios 6

up to 3000:1, and non- intrusive but wetted sensor designs are not subject to bending or failure and create no pressure drop. They meet or exceed government legislation, and eliminate risk of non-compliance. Based on empirical data, ultrasonic time of flight meters were specified in NORSOK STANDARD I-104, Section 7.1.3. Standard Sensor New high speed sensor Figure 10 7.0 References 1. SICK Maihak GMbH Nimburger Str. 11, 79276 Reute, Germany 2. Alberta Energy and Utilities Directive 17: Measurement Requirements for Upstream Oil and Gas operations February 1, 2005. 3. Alberta Energy and Utilities Directive 60: Upstream Petroleum Industry Flaring, Incinerating and Venting, November 16, 2006. 4. Mylvaganam, K.S. Ultrasonic gas flow meters Novel techniques of transducer orientation and signal processing make high-range ability possible. Measurement & Control, Dec. 1989, pp. 122-127. 5. Norsok Standard. Fiscal Measurement Systems for Hydrocarbon Gas. 1-104. Rev. 2, June 1998. Norwegian Technology Standards Institution 6. Norwegian Petroleum Directorate. Regulations to measurement of fuel and flare gas for calculation of CO2 tax in the petroleum activities, August 1993. ISBN 82-7257-395-4 7. Texas Commission on Environmental Quality Draft Flare Waste Gas Flow Rate and Composition Measurement Methodologies Evaluation Document Shell Global Solutions. 8. Flare Metering With Optics 25 th International North Sea Work Shop. October, 2007. 7