Precision Measurement of Small Gap within Closed Components by Industrial Computed Tomography

Similar documents
Business Quantitative Analysis [QU1] Examination Blueprint

Fatigue Behavior of 2198-T8 Aluminum-lithium Alloy with Riveted Lap Joints

Finite element modeling of impact strength of laser welds for automotive applications

Ring width detection for industrial purposes - use of CT and discrete scanning technology on fresh roundwood

A Modified Approach for Drawing Force Estimation of Bi-metallic Composite Pipe Forming M. Zheng1,a, J. Yu2,b

YXLON CT Compact. Fan-beam computed tomography (CT) inspection system for high-density medium and large-sized parts

Distinguish between different types of numerical data and different data collection processes.

Mobile Computed Tomography

Application of linear frequency modulated excitation on ultrasonic testing for austenitic stainless steel welds

Computed Tomography for Deepwater Pipelines Integrity

STRENGTH CONSEQUENCE MINIMIZATION OF DIGGING OFF BURIED GAS PIPELINE AT ISOLATION COAT RENOVATION REALIZED DURING OPERATION

EXPERIMENTAL AND NUMERICAL INVESTIGATIONS OF CONCRETE BEHAVIOUR AT MESO-LEVEL DURING QUASI-STATIC SPLITTING TENSION

ScienceDirect. Characterisation of ALUHAB aluminium foams with micro-ct

Effects of electrode immersion depth and remelting rate on electroslag remelting process

SAMPLING AND RISK ASSESMENT METHOD FOR METALLURGICAL INSPECTION OF PIPES AND TANKS

Design and Analysis of Multilayer High Pressure Vessels and Piping Tarun Mandalapu 1 Ravi Krishnamoorthy. S 2

Multiple Choice Questions Sampling Distributions

Description of concrete fracture at meso-level using Finite Element Method based on X-ray micro-ct images

Numerical Modeling of Cross - Wedge Rolling of Hollowed Shafts

Deformation Capacity and Performance-Based Seismic Design for Reinforced Concrete Shear Walls

2017 ACR Computed Tomography Quality Control Manual FAQS

Finite Element Analysis of the O-ring Squeezed into the Sealing Clearance Based on ABAQUS

The porosity test research of graphite material based on micron scale x-ray tomography

Mechanical Behavior and Characterization of Stern-shaft Mechanical Sealing Device. Yongjin Lu a *, Rui Lin

Microstructure characterization of high-strength Al-alloys by high resolution X-ray computed tomography

SteadyStateThermalAnalysisofShellandTubeTypeHeatExchangertoDemonstratetheHeatTransferCapabilitiesofVariousThermalMaterialsusingAnsys

Analysis of plastic penetration in process of groove ball-section ring rolling

LOAD BEARING ROLLER ASSEMBLIES Engineering Data Installation Notes

NUMERICAL SIMULATION AND EXPERIMENTAL RESEARCH ON CRACK MAGNETIC FLUX LEAKAGE FIELD

Development of a New Type of Earthquake Energy-absorption Device

Betatron radiography and tomography of steel castings with large thickness

Method of Optimal Scheduling of Cascade Reservoirs based on Improved Chaotic Ant Colony Algorithm

3D Computed Tomography (CT) A Powerful Tool for defects characterization in Aerospace Composite liners

RFS-CT HISTWIN High-Strength Steel Tower for Wind Turbine

Optimization Design of Arm Frame of Folding Arm Type Tower Crane Based on ANSYS Ge-ning XU, Wen-ju LIU * and Yan-fei TAO

THE SPRINGBACK ANALYSE ON SHEET ALUMINUM V BENDING USING AN SYSTEMIC ANALYSIS ON BENDING OPERATION

Forecasting the Quantity Trend of Human Resources with Higher Education in China Based on Correlation Regression Analysis

Alternating Current Potential Drop for Measuring the Case Depth of Hardened Steel

National standard of the People's Republic of China. GB/T Replace: GB/T Steel Forgings - Method for Ultrasonic Examination

BORAL CONTROL BLADE THERMAL-MECHANICAL ANALYSIS

Tex-739-I, Sampling and Testing Epoxy Coated Reinforcing Steel

Optimal Economic Life Interval Evaluation Method of Transformers

DNA genetic artificial fish swarm constant modulus blind equalization algorithm and its application in medical image processing

GUIDE TUBE INSPECTION. M.Montero, M.Grataloup, P.Blachon, CEGELEC, France

FAILURE INVESTIGATION OF REINFORCED CONCRETE CANTILEVER RETAINING WALLS

Practice Problems Set # 3 MECH 321 Winter 2018

Special Reinforced Concrete Structural Walls

MANUFACTURING SCIENCE-I Time: 1 hour (EME-402) Max. marks:30

Stability of a Mechanically Stabilized Earth Wall

Physicists Quality Control for MR Equipment

Wavelength-dispersive X-ray fluorescence spectrometer

Physical structure of matter. Monochromatization of molybdenum X-rays X-ray Physics. What you need:

THEORY QUESTIONS [60% of paper for weld fatigue]

7th task: Pad footing

The Impact of Rumor Transmission on Product Pricing in BBV Weighted Networks

CFD SIMULATION AND EXPERIMENTAL VALIDATION OF FLUID FLOW IN LIQUID DISTRIBUTORS

Study of Thickness Effect on Fracture Toughness of High Grade Pipeline Steel

RESULTS OF EXPERIMENTAL MEASUREMENTS AND CALCULATIONS OF PRESSURE LOSSES IN HD-PE PIPES. Pavel Mosler, Jan Melichar

Design of a new concentrated photovoltaic system under UAE conditions

Study of water falling film over horizontal drop shaped and inverted drop shaped tubes

Optimization of Low-Dose CT Protocol in Pediatric Nuclear Medicine Imaging

Experimental research on reduced beam section to concrete-filled steel tubular column joints with RC slab

Selecting a Sample Size

Revision 1 of EN Changes and news Klaus Berner 25. Oct. 2013


Finite element analysis of double layer metal bellows flexible hose for chemical pipeline Weijie Du, He-hui Wang 1,b), Shidong Wen 1,c) 1

How to calculate anchorage and lap lengths to Eurocode 2

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

A Project Cost Forecasting Method Based on Grey System Theory

Thermodynamics and Microstructure: Recent Examples for Coupling of Thermodynamic and Mobility Data to the Software MICRESS

M. H. Lai a, J. C. M. Ho b,*

Theoretical Modeling of Protective Oxide Layer Growth in Non-isothermal Lead-Alloys Coolant Systems: Quarterly Progress Report (01/01/05-03/31/05)

ELASTIC AND ELASTO-PLASTIC BUCKLING ANALYSIS OF PERFORATED STEEL PLATES

A new Glass GEM with a single sided guard-ring structure

ULTIMATE EARTHQUAKE RESISTANT CAPACITY OF CFT-FRAME

Fundamentals of X-ray diffraction and scattering

Lesson 1 X-rays & Diffraction

Clovis Community College Class Assessment

Study of Thin-Walled Box Beams Crushing Behavior Using LS-DYNA

Fundamental Course in Mechanical Processing of Materials. Exercises

STRUCTURE OPTIMIZATION OF WHEEL ON FATIGUE FAILURE

GUIDE TUBE INSPECTION. Faouzi KHAMASSI; Marcel TORTOLANO

Performance estimation of a remote field eddy current method for the inspection of water distribution pipes

Belleville Spring. The relation between the load F and the axial deflection y of each disc. Maximum stress induced at the inner edge

Wedge Wire Screens TALLERES NÚÑEZ. Screening Media

This experiment is included in the upgrade packages: XRC 4.0 X-ray characteristics and XRS 4.0 X-ray structural analysis.

Automated ultrasonic tube-to-tube sheet weld scanning

STRUCTURAL ANALYSIS. PSDS s.r.o. IČ: TRABANTSKÁ 673/18, PRAHA 9. for building permit. March 2012 NUMBER OF PAGES 15

DESIGN CURVES FOR STIFFENED PLATES WITH THE UNLOADED EDGES FREE FROM STRESSES USED IN STEEL BOX GIRDER BRIDGES

Research on Stabilization of Blade Vibration of Wind Turbine Based on Intelligent Control Theory

Stiffened flanges used in steel box girder bridges

Increased plastic strains in containment steel liners due to concrete cracking and discontinuities in the containment structure

Finite Element Analysis and Design Optimization of an Electrostatic Precipitator s Main Bearing Structure

Suppose we wanted to use a sample of 25 students to estimate the average GPA of all students. Now suppose we choose our sample by random sampling and

Model for Tangential Tensioning Stress in the Edge of Circular Saw Blades Tensioned by Multi-Spot Pressure

Fatigue Crack Initiation and Propagation in Thick Multilayer Metallic Laminates

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

A Flexible Synchronous Powder Feeder for Electromagnetism Compress Digital Manufacturing of FGM Metal Component

375 Seosuk-dong, Dong-Gu, Gwangju, , Korea Phone: , Fax:

Performance and characterisation of CsI:Tl thin films for X ray imaging application

Transcription:

ECNDT 006 - Poster 4 Precision Measurement of Small Gap within Closed Components by Industrial Computed Tomography Lingxia SUN, Ju LI, Yunchang YE, Aidong ZHANG, China Academy of Engineering Physics, Mianyang, Sichuan,China Abstract. The signal of small gap less than 0.5mm in closed components, which can be observed clearly on industrial computed tomography (ICT) image, can t be distinguished because of the limitation of resolution. In this paper, zone edge integration and its corresponding mathematic model have been established. The relative expression between the gap width and its specific integration value has been achieved by experimental results. The precise measuring method for small gaps, from 0.0mm to 0.5mm, of Beryllium, Aluminium and Steel has been established and the Beryllium, Aluminium and Steel corresponding measuring results have been given out. When the credibility probability is 95%, the measuring uncertainty is better than ±0.005mm. Introduction There are many standard methods to measure the width of regular small gap. But the X-ray tomography is superior for measuring the inner structure, assembly and geometric dimensions of the closed components. The common method for CT measurement is to make out the CT value curve through the measurement direction, to determine the measurement result with the full width at half maximum (FWHM) []. Figure shows how to measure the dimension of one round hole of the standard sample. The principle is to determine the eigenedge by the maximum CT grads within a certain region. For bigger gaps, the best measuring uncertainty can be up to half of the pixel size []. Beginning Point Ending Point Fig. Small Hole Diameter Measurement The minimum of the industrial computed tomography measurement is determined by the system spacial resolution. When the resolution is 3 lp/mm, the precisely measurable

minimum is 0.33mm, according to the definition. In the practical applications, there are many gap dimensions less than 0.mm. So it s not competent for small gap measurements with the common ICT method, owing to the theoretical confines of measuring scale and uncertainty. Figure gives out the CT tomogram and the measuring curve of the 0.5mm gap, achieved by the layered cross-section scanning method [3]. It shows the diversification eigenvalve of the gap density equals to the noise value, and the precise measurement can t be done. But the features of the gap are visible, even the 0.0mm gap can be easily found in the tomogram. It can be explained by the statistic theory: the CT values of the less features distribute in definite area, and it presents the probability denseness to be discerned. In the paper, a method called zone edge integration has been put forward, based on theoretical inference and experimental confirmation. The method can be used in the accurate measurement for Beryllium, Aluminium and Steel from 0.0mm to 0.5mm. Fig. Gap Measurement of Aluminium Component Mathematic Model for Zone Edge Integration The CT reconstruction submit to the linearity translation invariant theorem. The detectors have definite solid angle, so if the absorb coefficients are uniform and not consider the noise interference, the following expression can be proved: Ti μisi () Where T i stands for the CT value of a pixel, μ i stands for the absorb coefficient of the pixel, S i stands for the corresponding object area of the pixel. For the continuous and invariable space, the expression above can be simplified into: Ti S i () For the integral domain determined by gap features, the specific integration value S (non-dimension) and the CT value submit to the following expression: S T ( x, y) dxdy (3) If the scanning mode has been determined, the CT value is only related to the gap width. For the average value x within a certain length, there is: x x T y ( x) dx (4) x0 For the discrete circumstances, the proportion constant has been introduced, then the value is: x = A n i= 0 T yi + B (5)

In the formula, A and B are related to the detected material and the scanning mode, which are determined by experiments. The integrating range can be determined by distinguishing the effective signal from the random noise. In a certain area, there is: m T = T i (6) m i= m ( Ti T ) i= σ (7) = m WhereT σ stands for the signal noise ratio (SNR) in a certain area, and 3σ is the determinant value of the integrated edge. According to above mathematic model, the special software for measuring the small gap has been developed. 3 Experimental Method and Equipment In the experiment samples are made of Beryllium, Aluminium (LY) and Steel (00Cr7Ni4Mo) respectively, and each contains two rings whose gap can be adjusted by the special tools to imitate the inner gap of the component between 0.0mm to 0.5mm.The measured gap value is defined the nominal value. After the gaps scanned by the CT system, and the images got processed by special software, a serial of specific integration value S of the gaps can be achieved. The X-ray tube voltage is continuous and adjustable from 0 kev to 40 kev. The size of the focus is 0.8mm. The CT system has been equipped with five scanning modes, the field are Ø300 mm, Ø00 mm, Ø00 mm, Ø50 mm, Ø5 mm respectively. The best spacial revolution is 3 lp/mm, and the measuring uncertainty is ±0.05mm. In the experiment the voltage is 350 kev, the scan field is Ø5 mm, and the slice thickness is 0.5 mm. 4 Results 4. Experimental Data Processing The linear regression equation about the integration value and the nominal value can be determined by least square fit. The result is: x ˆ = A S + B (8) The values of A and B can be got by the following formula: S x n S x A = (9) S n S B = x A S (0) The linearly dependent coefficient can be got by the following formula: ( S S )( x x) r = () ( S S ) ( x x) 3

The Table shows the values of A, B, r got by experiments. The regression coefficients of the three materials are all close to.0. It indicates the significant linear dependence relation between the specific integration value S and the gap width. It can also testify the established mathematic model is correct. Table. Linear Regressive Parameters of Three Materials Material A B γ Aluminium.9477 0-5 0.00539 0.9973 Steel 6.996 0-6 0.00467 0.9977 Beryllium.945 0-5 0.00083 0.9989 The gap width value got by zone edge integration can be determined after putting the values of A, B, S of Beryllium, Aluminium and Steel into the formula (8). Calculate the differences between the gap width values and the nominal values and list the results into Table. The maximal differences between the calculated values and nominal values of Beryllium, Aluminium and Steel are 5.3μm.4μm3.9μm respectively. The results satisfy the testing requests of normal components. Table. Differences between Nominal Value and Gap Value Achieved by Zone Edge Integration mm No. Aluminium Steel Beryllium 0.005 0.0006 0.0005-0.005-0.004-0.008 3-0.007 0.00-0.0005 4 0.0004-0.0008-0.0004 5 0.0008 0.003 0.007 6 0.0004-0.005 0.003 7-0.000 0.00 0.0034 8 0.0030-0.0003-0.000 9 0.0005-0.00-0.0039 0 0.0053-0.00 Figure 3 shows the CT image and its measuring result of small gap. Figure 3(a) is the tomogram of Aluminium component with 0.05mm gap. The measuring value is 0.3mm according to FWHM method (Fig.3(b)) and 0.05mm according to zone edge integration method (Fig.3(c)). The Gap (b) Measuring Curve along a Straight Line (a) Tomogram of the Gap (c) Measurement of Specific Integration Value(S) Fig.3 Tomogram and the Measuring Result of Small Gap for Aluminium Component 4

4. The Uncertainties of Repeated Measurements Make the experimental parameters invariable, and repeat scanning 7 times for the same layer of Beryllium sample. So do the Aluminium and Steel samples. According to the statistic theory, the centre limiting law can t be applied when the number of sampling is small. So it can only apply the t distribution method to estimate the uncertainties of repeated measurements. If the confidence is 0.95, then α =0.05α / = 0.05. When the number of repeated measurements is 7, the freeness is n-=6, and t 0.05 =.447. So when the fiducial probability is 95%, the expectable uncertainty of measurement is: Δx = ±.447 σ n The uncertainties of measurements of small gaps for Beryllium, Aluminium and Steel samples are: Δx Al = ±.447 0.009=±0.0046 mm Δx Be = ±.447 0.006=±0.0039 mm Δx Fe = ±.447 0.008=±0.0044 mm 5 Discussion Figure 4 shows the regression lines of Beryllium, Aluminium and Steel samples. It shows the slopes of different material regression lines differ much, and the more the density, the smaller the slope value. 0. Nominal Value,mm 0.5 0. Be Δ Al Fe 0.05 0 0 000 4000 6000 8000 0000 000 4000 Specific Integration Value (S) Fig.4 Regression Lines of Nominal Values and Specific Integration Values There is a interested regulation that the regression coefficient A times the density of corresponding material is approximately equal to a constant. The data is showed in Table 3 (the material density ρ not measured on the experiment). Table 3. Relation between Regression Coefficient A and Material Density Material A ρ ( g/cm 3 ) A ρ Aluminium.9477 0-5.78 5.4 0-5 Steel 6.996 0-6 7.8 5.4 0-5 Beryllium.945 0-5.84 5.4 0-5 5

The regulation is important to measure some special materials. The linear coefficient A can be calculated by its density. Just one standard sample be required to determine the coefficient B before measuring the small gap by zone edge integration. To modify the material density on slope value by the rule in the measuring software, and to re-determine the linear modified parameters of Beryllium, Aluminium and Steel (see Table 4), it has been found that there is little difference among the slopes of different materials. The corresponding regressive lines have been showed in figure 5. 0. Nominal Value,mm 0.5 0. 0.05 Be Δ Al Fe 0 0 500 000 500 000 500 3000 3500 Specific Integration Value (S) Fig.5 Regression Lines of Beryllium, Aluminium and Steel after Density Modified 6 Conclusion X-ray computed tomography is a developing technique. Even though the existing hardware conditions can t be bettered, the measurement range and the uncertainty of measurement can be promoted by improving the arithmetic and optimizing programming. The small gap measuring method based on the zone edge integration, can better the measurable sizes of Beryllium, Aluminium and Steel from 0.33mm to 0.0mm and better the uncertainty of measurement from ±0.05mm to ±0.005mm. The result that the regression coefficient of the linear equation times the density of corresponding material is approximately equal to a constant, is significantly meaningful for measuring the small gaps in other materials. References [] P.J.NI, X.D.LI. Industrial computed tomgography technique.ndt,996(5),4 [] W. XIAN, S.G.LI. Industrial Computed Tomgography Technique.NDT,996(),57 [3] L.X.SUN, K.T.WEI, Y.C.YE. The research of CT testing on beryllium welding quality. Nuclear Technique,00(),55 6