A Mass Transfer Model of Absorption of Carbon Dioxide in a Bubble Column Reactor by Using Magnesium Hydroxide Slurry

Similar documents
Capture of Carbon Dioxide Using Aqueous Ammonia in a Lab-Scale Stirred-Tank Scrubber

Energy Procedia 4 (2011) Energy Procedia 00 (2010) GHGT-10

Flue Gas Desulfurization by Limestone and Hydrated Lime Slurries

Volumetric Mass Transfer Coefficient of SO 2 Gas Absorption into Aqueous Sodium Sulphite Solution in Plate Column

Experimental study on CO 2 absorption into aqueous ammonia-based blended absorbents

Absorption of SO 2 using PVDF hollow fiber membranes with PEG as an additive

Sandhya Eswaran, Song Wu, Robert Nicolo Hitachi Power Systems America, Ltd. 645 Martinsville Road, Basking Ridge, NJ 07920

Effects of Additives on Seawater Flue Gas Desulfurization

Removal of Acid Gases from Biomass-to-Liquid Process Syngas Used as Raw Materials for Fischer-Tropsch Technology

Simulation of CO 2 capture from an aluminium production plant

Stationary source emissions control

JOURNAL OF APPLIED SCIENCE AND AGRICULTURE

CO 2 capture using lime as sorbent in a carbonation/calcination cycle

Capture and Re-Use at a Waste Incinerator

Numerical Simulation of the Flue Gas Desulfurization in the Sieve Tray Tower

Air Pollution Technology Fact Sheet

Gas Holdup and Gas-Liquid Mass Transfer in Three-Phase Circulating Fluidized-Bed Bioreactors

Absorption of Nitric Oxide from Flue Gas using Ammoniacal Cobalt(II) Solutions by Hesheng Yu Supervisor: Dr. Zhongchao Tan

Removal of CO2 and H2S using Aqueous Alkanolamine Solusions

CARBONATION OF WOLLASTONITE USING SUPERCRITICAL CARBON DIOXIDE

Simultaneous Removal of SO 2 and CO 2 From Flue Gases at Large Coal-Fired Stationary Sources

SOLUBILITY OF CARBON DIOXIDE IN AMINE BLEND: EFFECT OF CYCLICS AND AROMATICS

Dual Flow Tray Technology for Wet FGD Performance Upgrades

Energy Procedia 00 (2008) GHGT-9. Comparison of solvents for post-combustion capture of CO 2 by chemical absorption

Kinetics of oxidative and SOx-induced degradation of monoethanolamine under accelerated laboratory conditions

Experimental Study of the Absorption and Regeneration Performance of Several Candidate Solvents for Post- Combustion CO 2 Capture

Treatment Technologies

A novel method for NOx and Hg emission control in power plants using existing wet limestone scrubbers

moleliquid := mole molegasinliq := mole totalmoleliquid := molegasinliq + moleliquid molegasinliq molegasinliq + moleliquid totalmoleliquid

Air Pollution Technology Fact Sheet

Information Centre Nitric Acid Plants. Kittiwake Procal Ltd Page 1 of 6

1) ABSORPTION The removal of one or more selected components from a gas mixture by absorption is probably the most important operation in the control

Available online at Energy Procedia 1 (2009) (2008) GHGT-9

"Post-combustion CO 2 capture by Ca-looping"

Solvents with low critical solution temperature for CO 2 capture

Chapter 7 Mass Transfer

Flue Gas Purification

UNIVERSITY OF CINCINNATI

Effect of Magnesium and Calcium Salts on the Sulfation Capacity of Trona Slurry

Effect of humidification water on semi-dry flue gas desulfurization

Continuous bioremediation of phenol polluted air in an external loop airlift bioreactor with packed bed Hossein Nikakhtari 1 and Gordon A.

Available online at ScienceDirect. Energy Procedia 51 (2014 )

Contents. Preface XI Nomenclature XIII. Part I Basic Concepts and Principles 1

Energy Procedia 4 (2011) Energy Procedia 00 (2010) GHGT-10

Numerical Study on the Effects of Flue-Gas Inlet Type for the Flue-Gas-Desulfurization Wet Scrubber

HYDROGEN R&D AT INEEL

OPTIMIZED DESIGN FOR HEAVY MOUND VENTURI

Hydrodynamic characters of co-current operation for SO 2 absorption in a laboratory packed column

Evaporative Gas Cooling and Emissions Control Solutions

OPTIMIZED DESIGN FOR HEAVY MOUND VENTURI

Effect of Moisture Conditioning and Handling on Leaching and Physical Properties of Sodium Bicarbonate Flue Gas Desulfurization Materials

Optimized CO 2 -flue gas separation model for a coal fired power plant

Modeling post-combustion CO 2 capture with amine solvents

Application of Gas Cyclone Liquid Jet Absorption Separator for Flue-Gas Desulfurization

Evaluating the Use of Airlift Pumps for Bioreactor Applications

Absorption of SO 2 in the MgO SO 2 H 2 O and in the Ca 2+ SO 2 H 2 O System

Fluor s Econamine FG Plus SM Technology For CO 2 Capture at Coal-fired Power Plants

A CFD Analysis of the Operating Conditions of a Multitube Pd Membrane for H 2 Purification

Absorption of SO 2 in a three-phase Bubble Column and Foam- Bed Slurry Reactor

Advances in Engineering Research (AER), volume 111 3rd Annual 2017 International Conference on Sustainable Development (ICSD2017)

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

Econamine FG Plus SM Technology for Post- Combustion CO 2 Capture

Available online at ScienceDirect. Energy Procedia 63 (2014 ) GHGT-12

Oxide Growth. 1. Introduction

Measurement and Calculation for CO 2 Solubility and Kinetic Rate in Aqueous Solutions of Two Tertiary Amines

MATHEMATICAL MODELING OF DRYING KINETICS OF CORN IN ELECTRON FIRED FLUIDIZED BED DRYER

Assessment of Solvent Degradation within a Global Process Model of Post-Combustion CO 2 Capture

Design Parameters Affecting the Commercial Post Combustion CO 2 Capture Plants

Dynamic Response of Monoethanolamine (MEA) CO2 Capture Units Robert Brasington and Howard Herzog, Massachusetts Institute of Technology

Cansolv Technologies Inc. Alberta NOx and SOx Control Technologies Symposium April 9, Rick Birnbaum

MSE 352 Engineering Ceramics II

Advanced CO 2 Capture process using MEA scrubbing: Configuration of a Split Flow and Phase Separation Heat Exchanger

Wastewater Pretreatment by Normal Freezing Cool Thermal Storage Process with Convective Heat Transfer Mechanism

CONTROL STRTEGIES FOR FLEXIBLE OPERATION OF POWER PLANT INTEGRATED WITH CO2 CAPTURE PLANT

Omya Water & Energy omya.com. Flue Gas Cleaning. Sustainable and efficient flue gas desulfurization (FGD)

Modelling of CO 2 capture using Aspen Plus for EDF power plant, Krakow, Poland

Available online at ScienceDirect. Energy Procedia 63 (2014 ) GHGT-12

Experimental Observation for Multi Nozzle Liquid Jet Ejector for Chlorine- Aqueous Caustic Soda System at Laboratory Scale

Worldwide Pollution Control Association. August 3-4, 2010

Zhongchao Tan. Air Pollution and Greenhouse Gases. From Basic Concepts to Engineering. Applications for Air Emission Control.

Nathan A. Hatcher and Ralph H. Weiland, Optimized Gas Treating Inc., USA, discuss the fate of ammonia in refinery amine systems.

Mass Transfer Rate Modeling Basics. Nathan A. Hatcher, P.E. AIChE South Texas Section Dinner Pellazio Banquet Hall, Houston TX September 11, 2014

Index for Labs under Chemical Engineering

Available online at Energy Procedia 1 (2009) (2008) GHGT-9

Aspen plus simulation of CO 2 removal from coal and gas fired power plants

Energy Production Systems Engineering

Pilot absorption experiments with carbonic anhydrase enhanced MDEA

Optimization of an Existing 130 Tonne per Day CO 2 Capture Plant from a Flue Gas Slipstream of a Coal Power Plant

Trickle bed reactor diluted with ne particles and coiled tubular ow-type reactor for kinetic measurements without external effects

Study of Calcination-Carbonation of Calcium Carbonate in Different Fluidizing Mediums for Chemical Looping Gasification in Circulating Fluidized Beds

Using Hydrated Lime and Dolomite for Sulfur Dioxide Removal from Flue Gases

Report Requirements (submit electronic and hard copy version) Due Date: 9 AM on May 5, 2014

Available online at Energy Procedia 4 (2011) Energy Procedia 00 (2010) GHGT-10

EEC 503 Term Project No 2

Elizabeth M. Glogowski, John Vericella, and Jennifer A. Lewis University of Illinois UrbanaChampaign, Illinois, USA.

THE REMOVAL OF DISSOLVED AMMONIA FROM WASTEWATER THROUGH A POLYPROPYLENE HOLLOW FIBER MEMBRANE CONTACTOR

Taravosh Jam Design & Engineering Co.

Options for Mitigating Environmental Pollution from Energy Production and Uses

Chilled Ammonia Process Update. Richard Rhudy, EPRI Sean Black, ALSTOM CO 2 Capture Network May 24, 2007 Lyon, France

WHITE PLUME REMOVAL USING FUEL ADDITIVES IN THERMAL POWER PLANTS

Transcription:

A Mass Transfer Model of Absorption of Carbon Dioxide in a Bubble Column Reactor by Using Magnesium Hydroxide Slurry Lei Cheng a, Tongyan Li a, Tim Keener a,*, Joo-Youp Lee b a Environment Engineering Program, School of Energy, Environmental, Biological, and Medical Engineering, The University of Cincinnati, Cincinnati, OH45221, USA b Chemical Engineering Program, School of Energy, Environmental, Biological, and Medical Engineering, The University of Cincinnati, Cincinnati, OH45221, USA Introduction A novel CO 2 scrubbing process, using Mg(OH) 2 slurry as the removal agent, has been proposed and investigated at the University of Cincinnati. The proposed Flue Gas Decarbonation system (FGDC) consists of a bubble column reactor, where the magnesium hydroxide slurry is injected at the top of the reactor to encounter the fine flue gas bubbles which are introduced through a fine fritted glass bubbler at the bottom of the reactor. The FGDC system also has a desorption reactor in order to increase the magnesium utilization, where the rich slurry is regenerated by applying the means of thermal-pressure swing. In the meantime, concentrated CO 2 in the gas stream is collected. The absorption of CO 2 from the flue gas is accomplished at 52 which falls into the typical range of Flue Gas Desulfurization (FGD) outlet temperature. Therefore, the unit may be retrofitted or attached to FGD system without modification of the existing boiler-heat transfer configuration. In addition, compared to the most widely used solvents, such as MEA, ammonia, ionic solution, and PZ-K 2 CO 3 solution, magnesium hydroxide slurry is non-toxic, nonflammable, non-corrosive and odorless milky solution and can be reclaimed (Lani, 1998) from any limestone based FGD sorbents or obtained from commercial sources at a reasonable price. Bubble column is selected as the gas-liquid contacting device for this study due to the simple internal design, good mass transfer performance and great ability of handing solid containing solution or slurry for the magnesium slurry test. The tests using magnesium hydroxide demonstrate comparable CO 2 removal efficiencies to the MEA, NaOH, ammonia, ionic solution these solvents. The purpose of this study is to investigate the chemical reaction mechanisms and the mass transfer phenomena in the absorption process, and to develop a bubble column absorber model to assist in the understanding of the mass transportation of CO 2 removal within a gasliquid-solid system. Model development The whole scrubbing process may be characterized as physical absorption of CO 2 in water coupled with 1). Ionic reactions between dissolved CO 2 and magnesium ions; and 2). Solid dissolution of magnesium particles. Therefore, this paper will first present physical absorption case of CO 2 -H 2 O and then absorption with chemical reactions case of CO 2 -Mg(OH) 2 as following.

Physical absorption of CO 2 -H 2 O Bubble column is preferred to operating under homogeneous conditions which the flow motion falls into the laminar flow regime (Shah et al., 1982; Treybal, 1967). This bubbly flow may give more uniform and smaller bubbles resulting larger surface area and longer retention time. Under such flow regime, liquid phase and bubble phase coexists. Therefore, the system may be described by the two film theory model. The model is based on the main assumptions: the liquid phase is well mixed and the gas phase is in plug flow. Absorption rate,, can be expressed in terms of gas or liquid side mass transfer coefficient based on the film theory: (1) (2) and are CO 2 concentrations at the gas-liquid interface following the Henry s Law. The interfacial compositions cannot be determined. Instead, the bulk driving force which may be characterized as overall mass transfer coefficient can be applied. Therefore, the absorption rate can be written as: The CO 2 partial pressure in the bubble will change with the position in the column. Here, it is assumed that a pseudo-steady state condition exists between the CO 2 partial pressure of the bubble and the CO 2 concentration in the liquid. Therefore, the Equation (4) can be rewrite as: Perform a mass balance on CO 2 in the bubble as it rises up the column in the x direction assuming a pseudo-steady state condition. Letting,,, then: This is the governing equation for bubble column absorption. It expresses the change of concentration of CO 2 in the liquid in terms of the bubble CO 2 partial pressure which is changing with respect to the position in the liquid column, z. Therefore, the average CO 2 concentration in the bubble can be found by integrate Equation (7) between the limits of z=0, p A =p 0 and z=1: (3) (4) (5) (6) (7)

Substitute the average bubble CO 2 concentration into the Equation (5), integrated with respect to the time: (9) (8) Where: ( ) Then, solve for overall mass transfer coefficient as: This equation revealed that the overall mass transfer rate is depend on the hydrodynamic parameters, equilibrium constant, CO 2 partial pressure in the gas phase and the temperature. In addition, it is necessary to calculate the total dissolved carbon and ph when system reaches the equilibrium. These numbers provide the quality assurance when we perform the experiment data analysis. Absorption with reaction of CO 2 -Mg(OH) 2 system The major reactions in the system are: gas absorption and diffusion, ionic ions reactions at liquid phase, solid dissolution and diffusion. It is assumed that the reaction between dissolved CO 2 and the magnesium ions is instantaneous with respect to the mass transfer. Therefore, the chemical reaction is viewed as an enhancement factor for the process; while the gas side mass transfer and the dissolution of solid magnesium hydroxide particles are viewed as rate limiting steps. According to the film theory, in order to make CO 2 gas reacts with the magnesium hydroxide slurry, the CO 2 in the gas phase needs to be dissolved and disassociated to form carbonate ions and transferred into the liquid phase; on the other hand, the magnesium hydroxide solid particles need to be dissolved and disassociated as magnesium and hydroxyl ions and transferred into the liquid phase. The reaction will occur at a plane in the liquid at a position close to the gas/liquid interface as these ions reach the reaction zone. The rate will be determined by the mass transfer rate of diffusion of CO 2 and magnesium ions. The rate of CO 2 absorption in the liquid may be expressed as: (10) (11) (12)

(13) The interfacial concentrations are assumed to be at equilibrium and may be related through Henry s Law. The mass transfer of CO 2 and magnesium ions within the film may be explained by the diffusion, therefore, the transfer coefficient for CO 2 (A) and magnesium ions (B) in the liquid are related by: Where and are the liquid diffusivities of dissolved CO 2 and magnesium ions, respectively. Also, the dissolution rate may be explained by the diffusivity of magnesium ions in the solution and the film thickness around the solid particle: Equations listed above can be solved to obtain a rate expression for Mg(OH) 2 slurry scrubbing CO 2 : (14) (15) (16) (17) Letting φ, the equation becomes (18) φ Whereφis the chemical enhancement factor; and the unit is mol/cm 2 -atm-sec: is the overall mass transfer coefficient, and (19) φ This is the definition term of the overall mass transfer coefficient. It clearly revealed that physical absorption and diffusion are rate limiting steps; but chemical reactions serve as rate enhancement factor. In order to quantify this coefficient, the rate expression may need to be rewritten as:

(20) Repeat the steps from Equation (7) to (10) to solve for the overall mass transfer coefficient, : (21) This equation allows us to calculate the overall mass transfer coefficient once the amount of carbon removal with respect to time is known. Experimental The absorption experimental setup consists of six major sections: (1) simulated flue gas generation; (2) flow control; (3) bubble column reactor; (4) gas sampling and analysis; (5) ph, temperature measurement; (6) data acquisition. The experimental setup is shown schematically in Figure 1. A 130 cm tall, diameter of 10 cm column made of plastic glass with a heating jacket and thermo insulation was used as the main body of the bubble column reactor. 3 sampling ports are respectively located near the top, middle and bottom of the reactor to obtain complete temperature and ph profile of the reactor. Fritted glass size C (porosity 25-50 micron, ACE glass Inc.) was installed at the bottom of the reactor as the gas bubbler. The column was sat on the magnetic stirrer plate which allows magnetic mixing to be applied to the fluid inside the column. The simulated flue gas is produced by mixing pure CO 2 gas with pure N 2 gas (high purity >99%, Wright Brothers Inc.). Both gas streams are controlled by mass flow controllers (Thermal gas mass flow controller, Cole Parmer Inc.) in order to have desirable CO 2 concentration. The mixed gas stream is heated and maintained at 52 which is close to the typical temperature at FGD outlet. The gas sampling system consists of an in-line flue gas conditioning unit (IMR 400 flue-gas conditioning system, Environmental Equipment Inc.) where the particles in the sample are removed by the filter, and water vapor is removed by passing through the nafion dryer. The pretreated gas sample is then analyzed for CO 2 concentration by an infrared CO 2 gas analyzer (Model ZRH infrared analyzer, California Analytical Instruments Inc.) The CO 2 gas analyzer is periodically calibrated by using pure N 2 (high purity >99%, Wright Brothers Inc), 5% CO 2 and 16% CO 2 (certified grade, CO 2 in N 2, Purity Plus Gas Inc) standard gases. Magnesium hydroxide solution is prepared by dissolving magnesium hydroxide powder (industry grade, 81% purity, Garrison Minerals LLC.) into deionized water. Table 1. Experiment conditions.

Parameter Value Inlet gas temperature ~52 Liquid temperature 25 to 54 Gas flow rate 0.5 L/min Inlet CO 2 concentration ~12 % vol. Mg(OH) 2 concentration 0.01 to 1 M Liquid volume 2.1 L Mixing rate 1200 RPM Porosity of gas bubbler 25-50 micron to vent Flue gas conditioning unit NDIR CO2 analyzer Computer with data acquisition ph meter Mass flow control Temperature measurement Gas cylinder CO2 N2 Bubble column reactor with heating jacket Magnetic stirrer Figure 1. Schematic of the experimental setup. Results and discussion CO 2 -H 2 O system 25, 39, 47 and 54 temperatures have been tested for pure water absorption. The average overall mass transfer coefficient is found from 2.75E-7 to 4.1E-7 mol/cm 3 -atm-sec. As showed in Figure 2, it was found that the overall mass transfer rate decreases as the temperature increases. This is because that as temperature increases, both diffusivities of CO 2 in air and in water increase leading the individual mass transfer coefficient on gas (k g ) and liquid side (k L ) to increase; however, the physical absorption governing factor-henry s constant decreases as temperature increases. The change of Henry s constant is greater than the change of individual mass transfer rates; therefore, the overall mass transfer rate is calculated to follow the same trend as Henry s constant. (22) Where: ;

If we assume that gas film thickness equals liquid film thickness and they do not change with respect to the temperature. It is found that 0.024 cm is the film thickness. The increase of temperature also decreased the water absorption capacity on CO 2. It is found that the dissolved carbon concentration at equilibrium decreased from 0.004 mol/l to 0.002 mol/l when temperature increased from 25 to 54. Figure 3 shows that our model can adequately predict the total carbon concentration in the liquid for CO 2 -water absorption process in the bubble column. 4.4E-007 4E-007 KGa, mol/cm 3 -atm-sec 3.6E-007 3.2E-007 2.8E-007 2.4E-007 20 30 40 50 60 Temperature, C Figure 2 (left graph). Overall mass transfer rate at different temperatures for water absorption. Figure 3 (right graph). Comparison of measured value and predicted value of total carbon concentration in the liquid. CO 2 -Mg(OH) 2 system Figure 4 shows the relationship of overall mass transfer rate and the concentration of Mg(OH) 2 solutions under the temperature of 25 and 52. It is found that higher the concentration of magnesium solutions and higher the temperature, higher the overall mass transfer coefficient. But 0.1M solution only has slightly higher mass transfer rate than 0.05 M solution at both tested temperatures.

Overall mass transfer coefficient, mole/cm 3 -atm-second 9.0x10-7 8.0x10-7 7.0x10-7 6.0x10-7 5.0x10-7 4.0x10-7 3.0x10-7 2.0x10-7 25 52 0 0.00 0.02 0.04 0.06 0.08 0.10 Mg(OH) 2 concentration, mole/l Total dissolved carbon C AT, mole/l 0.18 measured 0.1M predicted 0.1M 0.16 measured 0.05M predicted 0.05M 0.14 measured 0.025M 0.12 predicted 0.025M measured 0.01M 0.10 predicted 0.01M 0.08 0.06 0.04 0.02 0.00 0 10 20 30 40 50 Time, min Figure 4 (left graph). Overall mass transfer coefficient comparison at temperatures of 25 and 52. Figure 5 (right graph). Comparison of measured and predicted values of total dissolved carbon. Figure 5 shows that the predicted and measured values of total dissolved carbon in the liquid for CO 2 -Mg(OH) 2 batch mode operations are close to each other. In addition, a serial of continuous tests for each concentration are conducted. It is confirmed that the model can accurately predict the concentration of dissolved carbon with respect to the time. Therefore, the overall mass transfer coefficient found from batch tests can be used for designing the continuous system in the future. Table 2 summaries the literature findings on mass transfer coefficients. It is revealed that our system has comparable mass transfer rate as MEA and NaOH s. Table 2. Comparison of mass transfer coefficients. Scrubbing agent Contacting device Experiment conditions MEA-MDEA(Sema et al., 2012) MEA(Kuntz and Aroonwilas, 2009) MEA(Luo et al., 2011) MEA(Chen, 2012; Chen et al., 2008) NaOH(Chen et al., 2008) NH 3 (Chen, 2012) Structured DX packed column Spray tower and packed tower String of discs contactor Bubble column Packed column Bubble column T=25-60 ; C MDEA/MEA = 1.95/1.16, 2.1/0.8, 2.3/0.5 M T=25 ; C MEA =3-7 M; P CO2 =0.05-0.15 atm T=50 ; C MEA = 5 M T=25-45 ; P CO2 =0.1-0.3 atm; C MEA = 4 M P CO2 =0.1-0.3 atm; C NaOH = 2 M T=25-60 ; P CO2 =0.15-0.6 atm; C NH3 = 7.7 M Mass transfer coefficient, gmol/cm 3 -atm-second 2.8E-6 to 2.5E-5 2.2E-6 to1.25e-4; 2E-6 to 4.2E-6 8.3E-7 6.6E-7 to 9.1E-6 5.4E-7 to 7.7E-6 4.9E-7 to 2.1E-5

Mg(OH) 2 This work Bubble column T=25 and 52 ; P CO2 =0.12 atm; C Mg(OH)2 =0.01-0.1 M 3.4E-7 to 7.7E-7 Conclusions A bubble column reactor model, based on the assumptions of 1). Liquid is well mixed and under laminar flow region; 2). Gas is plug flow, was developed for CO 2 removal data analysis. The model incorporated physical absorption between CO 2 and water, dissolution of Mg(OH) 2 solid particles, diffusion within the gas and liquid phases, and chemical reactions of the ions. The film theory was used to understand the transport phenomenon. It is found that 0.024 cm is the film thickness which explains the change of the overall mass transfer rates caused by the change of temperatures. The overall mass transfer coefficient, a key designing parameter, is found to be a function of the hydrodynamic parameters, Henry s constant, CO 2 partial pressure in the gas phase, diffusivities, solid dissolution constant and temperature. The overall mass transfer coefficients found from this study are comparable to the other widely studied scrubbing chemicals, such as MEA and ammonia solutions. Acknowledgements The authors would like to acknowledge the financial support for this study under project number: DE-FE0001834 from the U.S. Department of Energy. Also, Lei Cheng would like to express his appreciation to the University of Cincinnati for a UGS tuition scholarship during this work. References Chen, P.-C. (2012). Absorption of Carbon Dioxide in a Bubble-Column Scrubber, Greenhouse Gases - Capturing, Utilization and Reduction. (InTech). Chen, P.-C., Shi, W., Du, R., and Chen, V. (2008). Scrubbing of CO2 Greenhouse Gases, Accompanied by Precipitation in a Continuous Bubble-Column Scrubber. Ind Eng Chem Res 47, 6336-6343. Kuntz, J., and Aroonwilas, A. (2009). Mass-transfer efficiency of a spray column for CO2 capture by MEA. Energy Procedia 1, 205-209. Lani, B. (1998). Advanced ThioClear process testing. Final report. In Other Information: PBD: [1998], pp. Medium: ED; Size: 215 p. Luo, X., Hartono, A., Hillestad, M., and Svendsen, H.F. (2011). The study of numerical methods and validation of a heat and mass transfer model in CO2 -MEA system. Energy Procedia 4, 1435-1442. Sema, T., Naami, A., Fu, K., Edali, M., Liu, H., Shi, H., Liang, Z., Idem, R., and Tontiwachwuthikul, P. (2012). Comprehensive mass transfer and reaction kinetics studies of CO2 absorption into aqueous solutions of blended MDEA MEA. Chemical Engineering Journal 209, 501-512. Shah, Y.T., Kelkar, B.G., Godbole, S.P., and Deckwer, W.D. (1982). Design parameters estimations for bubble column reactors. AIChE Journal 28, 353-379. Treybal, R.E. (1967). Mass-transfer operations, 2d edn (New York,, McGraw-Hill).