Training Certification Categories

Similar documents
PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

Building Permit Application

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

CONSTRUCTION DOCUMENTS NECESSARY FOR PLAN REVIEW

City Of Mendota Construction Procedures

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

Village of Gurnee Construction Documents Submittal Requirements

City of South Pasadena COMMUNITY IMPROVEMENT

1 AND 2 FAMILY DWELLING REQUIREMENTS

IECC Residential Significant Changes Summary. Tier I

City of Rohnert Park Building Department Inspection Descriptions

PERMIT SUBMITTAL GUIDE FOR COMMERCIAL PROJECTS

B. RESIDENTIAL MASTER PLUMBER $ $ $

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

Plan Check & Field Inspection Guide

Uniform Construction Code

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

FRANKLIN VILLAGE APARTMENTS Building I Franklin Street Morristown, NJ Block: 3901 Lots: 4,5,6

INSPECTION REQUIREMENTS Page 1 of 5. JOB SITE ADDRESS posted during entire construction process.

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

2009 IECC Chapter 1 Additions, alterations, renovations or repairs.

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

REScheck Software Version Compliance Certificate

9) Home Inspection: As defined in Section 1-10 of the Act.

TITLE 68: PROFESSIONS AND OCCUPATIONS CHAPTER VIII: DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

Section Standards of Practice. a) The following are terms commonly used in the writing of home inspection reports.

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

SERIES 0 BIDDING REQUIREMENTS AND CONTRACT FORMS

COMMERCIAL ENERGY EFFICIENCY

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

City of Westerville Guide to Commercial Inspections

INTERNATIONAL CODE INTERPRETATIONS

Boulder City NV Prepared by (Print Name) Signature Date

Franklin Hall Renovation TABLE OF Document Indiana University Bloomington

Residential Construction Minimum Required Inspections

Charter Township of Washington

New Jersey Home Inspection - Standards of Practice

IECC 2006 with Hawaii Amendments

Feature Zone IECC 2009 IECC

Hardin County Planning and Development Commission

COMcheck Software Version Envelope Compliance Certificate

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

REQUIREMENTS FOR CONTRACTORS IN THE CITY OF LIBERAL, KANSAS

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

Residential Building Inspections

2014 British Columbia Building Code Changes

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

Oregon Building Officials Association

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Watercrest - Sand Hill - Columbia, SC TABLE OF CONTENTS PROCUREMENT AND CONTRACTING REQUIREMENTS

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

2/23/2009 R15-R20R20

Inspection of New One- and Two- Family Dwellings

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2)

Residential Building Plans

CITY OF RICHMOND HEIGHTS DEPARTMENT OF BUILDING ZONING AND HOUSING STANDARDS AND REGULATIONS

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

City of Omaha Plans and Permits Commercial Alterations and Conversions Building Permit Submittal Checklist

TOWN OF FRANCESTOWN BUILDING/CODE ENFORCEMENT 27 MAIN STREET P.O. BOX 5 FRANCESTOWN, NEW HAMPSHIRE Building Permit Application Guide

Nassau County Building Department

TABLE OF CONTENTS Public Safety Building

City of Guntersville Residential Building Permit

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

CM ASSIGNMENT OF TEMPORARY FACILITIES see included IU Project Site Requirements

2015 Michigan Residential Code Energy Worksheet for Single-family Additions, Alterations, Renovations and Repairs

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

BUILDING CONSTRUCTION

COUNTY OF NEVADA BUILDING DEPARTMENT POLICIES

A.ENVELOPE AIR SEALING

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

Division II Contractors

GENERAL PLAN REVIEW REQUIREMENTS

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

REPORT CHECKLIST SUPPLEMENT

The Homeowner s Building Application Checklist for Constructing a Residential Addition

UCC Permit Application Procedures

Appendix J - Custom Uniformat for EDU Migration

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Plains Township Building Permit Application

Transcription:

Training Certification Categories Residential Residential Building Inspector structures are free from hazardous structural conditions and comply with the UCC. Duties include inspection of footings and foundations, concrete slabs, wood decay and termite protection, floor and ceiling framing, wall framing, roof framing, masonry walls, sheathing, roof covering, interior and exterior wall coverings, means of egress system and safety glazing. Residential Electrical Inspector structures are free from hazardous electrical installations and comply with the UCC. Duties include determining compliance of electrical service, electrical distribution systems, wiring methods, panel boards, control devices, conductors and electrical fixture installation. Residential Mechanical Inspector structures are free from hazardous mechanical installations and comply with the UCC. Duties including determining compliance of mechanical equipment, gas fuel supply systems, venting appliances, air ducts, combustion air and comfort cooling. Residential Plumbing Inspector structures are free from hazardous plumbing installations and comply with the UCC. Duties include determining compliance of water service, building sewer, water distribution, draining, waste and vents and fixtures. Residential Energy Inspector Inspects one-family and two-family dwellings and jurisdictional accessory structures to ensure that energy installations are made in the manner specified in the UCC. Duties include determining compliance of conditioned or unconditioned spaces, R-values for roof/ceiling, floor and wall assemblies and insulation placement, installation of materials for the building envelope and its components, moisture control methods such as caulking, sealing and weather-stripping, duct and dipping insulation and sealing criteria, thermostats for each heating and cooling system, electrical metering, lighting installation and controls and piping insulation, circulation pump controls, heat traps, shower heads and pool cover installations.

Administrative Building Code Official (Code Administrator) Manages, supervises and administers building code enforcement activities. The Department, municipality or a third-party agency that operates an enforcement program under the act will employ at least one person certified or registered as a building code official. Duties include management of building code enforcement activities, supervision of building inspectors or plans examiners, issuing building permits, occupancy permits, notice of violations and orders to vacate, and initiation of prosecutions. Department of Labor & Industry Elevator Inspector Inspects electric and hydraulic elevators, conveying systems and other lifting devices to ensure that these installations are free from conditions that would present a life safety or fire hazard to persons using the installations. Duties include determining compliance with the UCC regarding door closers, interlocks, car safeties, over-speed governors, safety tests, reshackling, ropes, fireman's recall, brakes and other related elevator equipment and the investigation of accidents. Passenger Ropeway Inspector Inspects passenger ropeways to ensure that the installation is free from conditions that would present a life safety or fire hazard to a person using the installation. Duties include investigation of accidents and determining compliances of power units, auxiliary power units, carriers, cabins, cars, location, vertical and horizontal clearances, haul rope sleeves, guides, haul rope condition and splice, structures and foundations, capacity, speed, acceleration/deceleration, loading and unloading areas, required stopping devices, brakes and rollback devices, tension systems, manual and automatic control devices, haul rope grips, operation and maintenance of equipment, electrical components, emergency shut down circuits, bypass circuits, speed regulating devices, and other related ropeway equipment with the UCC. Commercial* Commercial Building Inspector Ensures that buildings and structures are constructed in accordance with the UCC. Duties include inspection of construction site and building location, footings and foundations, wood and steel framing and connections, masonry construction, precast and cast-in-place concrete, exterior weather boarding, fire-stopping and draft-stopping, building components related to life safety and fire protection systems and building components related to size, installation and workmanship. May also perform residential building inspector duties.

Commercial Building Plans Examiner UCC. Duties include determining the degree of compliance necessary for new construction projects, alterations or repairs, proper use group/type of construction classification, determining height and area requirements, minimum means of egress requirements, minimum light and ventilation requirements, minimum design structural loads, adequacy of soils investigations, adequacy of footing and foundation designs, minimum fire-resistance requirements, adequacy of barrier-free designs, minimum energy conservation requirements and adequacy of fire-protection systems. Commercial Electrical Inspector Ensures that electrical installations are made in accordance with the UCC regardless of the size or components used in the installation. Duties include determining compliance of raceways (installations, size), cables, panel boards and boxes, conductors, control devices, motors and generators, electrical equipment and special occupancies. May also perform residential electrical inspector duties. Commercial Electrical Plans Examiner UCC. Duties include determining proper number of services, proper location of services, adequacy of emergency systems, proper service size, proper over-current protection, special use applications and proper conductor size and application. Commercial Mechanical Inspector Ensures that mechanical installations are made in the manner specified in the UCC. Duties include determining compliance of fuel piping systems, heating, cooling and ventilation, fuel-fired equipment venting, steam and hot water heating systems and piping and energy conservation. May also perform residential mechanical duties. Commercial Mechanical Plans Examiner UCC. Duties include determining compliance of fuel piping systems, fuel-burning appliances, mechanical refrigeration systems, incinerators, energy conservation equipment and controls, boilers and pressure vessels, venting systems, hydronic and steam-piping systems and ventilation air systems. Commercial Plumbing Inspector Ensures that plumbing installations are made in accordance with the UCC. Duties include determining compliance of underground piping installation, rough-in inspections, drain-waste-venting (DWV) systems, pressure testing, water distribution systems, observation and elimination of cross connections, system pumps, tanks and pressure vessels and fixtures, traps and valves and their connections. May also perform residential plumbing inspector duties.

Commercial Plumbing Plans Examiner UCC. Duties include determining that water service, building sewer/storm sewer and other underground piping are properly sized and located, determining that proper drainage fixture units, fixture locations and clearances are used, determining the adequacy of drain-waste-venting (DWV) riser diagrams and water distribution systems and determining the proper number of fixtures and proper materials as proposed. Commercial Energy Inspector Ensures that the building envelope, mechanical systems, electrical power and lighting systems and building service systems and equipment comply with the approved construction documents and the UCC. Duties include verifying that building envelope and components meet minimum requirements for installation of materials and that building envelope penetrations are caulked, sealed and weatherstripped, determining compliance of moisture control methods, installation of and types of mechanical equipment and efficiencies, heating, ventilation and air conditioning (HVAC) equipment, ducts and piping, insulation and sealing, lighting installation and lighting controls for building interiors and exteriors, permanently wired poly-phase motors and their efficiencies, piping insulation, circulation pump controls, heat traps, point-of-use controls and pool cover installations. May also perform residential energy inspector duties. Commercial Energy Plans Examiner Ensures that the design criteria specified for a building are correct and in accordance with the UCC and that alterations, additions and change of use or occupancy are in compliance with the UCC. Duties include determining compliance of the design conditions specified, conditioned or unconditioned spaces, R values for roof/ceiling, floor and wall assemblies and insulation placement, insulation of materials for the building envelope and its components, moisture control methods such as caulking, sealing and weather-stripping, duct and dipping insulation and sealing criteria, thermostats for each heating and cooling system, electrical metering, lighting installation and controls, piping insulation, circulation pump controls, heat raps, shower heads and pool cover installations. Commercial Fire Inspector Conducts basic fire prevention inspections and has a general knowledge of applicable codes and standards. Duties include field inspections, preparation of correspondence and inspection reports, handling complaints, and maintaining files related to inspections that were conducted. Commercial Accessibility Inspector/Plans Examiner Ensures that buildings and structures are constructed in accordance with the accessibility provisions of the UCC and that construction documents submitted as part of a permit application comply with the accessibility provisions of the UCC. Duties include inspection of building sites and all interior building components to verify compliance with the accessibility standards or review of construction documents to verify that the design of building sites and all interior components comply with the accessibility standards.

*Certification Reciprocity: Persons who obtain commercial inspection certifications may perform the same services in the residential sector. For example, a certified Commercial Plumbing Inspector may also perform residential plumbing inspections.